RESUMEN
AIMS: Simulator training has been recently introduced in electrophysiology (EP) programmes in order to improve catheter manipulation skills without complication risks. The aim of this study is to survey the current use of EP simulators and the perceived need for these tools in clinical training and practice. METHODS AND RESULTS: A 20-item online questionnaire developed by the Scientific Initiatives Committee of the European Heart Rhythm Association (EHRA) in collaboration with EHRA Digital Committee was disseminated through the EHRA Scientific Research Network members, national EP groups, and social media platforms. Seventy-four respondents from 22 countries (73% males; 50% under 40 years old) completed the survey. Despite being perceived as useful among EP professionals (81%), EP simulators are rarely a part of the institutional cardiology training programme (20%) and only 18% of the respondents have an EP simulator at their institution. When available, simulators are mainly used in EP to train transseptal puncture, ablation, and mapping, followed by device implantation (cardiac resynchronization therapy [CRT], leadless, and conduction system pacing [CSP]). Almost all respondents (96%) believe that simulator programmes should be a part of the routine institutional EP training, hopefully developed by EHRA, in order to improve the efficacy and safety of EP procedures and in particular CSP 58%, CRT 42%, leadless pacing 38%, or complex arrhythmia ablations (VT 58%, PVI 45%, and PVC 42%). CONCLUSION: This current EHRA survey identified a perceived need but a lack of institutional simulator programme access for electrophysiologists who could benefit from it in order to speed up the learning curve process and reduce complications of complex EP procedures.
Asunto(s)
Terapia de Resincronización Cardíaca , Médicos , Masculino , Humanos , Adulto , Femenino , Encuestas y Cuestionarios , Terapia de Resincronización Cardíaca/métodos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Electrofisiología Cardíaca , Trastorno del Sistema de Conducción Cardíaco/terapia , Europa (Continente)RESUMEN
AIMS: Although guidelines for the management of atrial fibrillation (AF) are regularly published, many controversial issues remain, limiting their implementation. We aim to describe current clinical practice among European Heart Rhythm Association (EHRA) community according to last guidelines. METHODS AND RESULTS: A 30 multiple-choice questionnaire covering the most controversial topics related to AF management was distributed through the EHRA Research Network, National Societies, and social media between January and February 2023. One hundred and eighty-one physicians responded the survey, 61% from university hospitals. Atrial fibrillation screening in high-risk patients is regularly performed by 57%. Only 42% has access to at least one programme aiming at diagnosing/managing comorbidities and lifestyle modifications, with marked heterogeneity between countries. Direct oral anticoagulants are the preferred antithrombotic (97%). Rhythm control is the preferred strategy in most AF phenotypes: symptomatic vs. asymptomatic paroxysmal AF (97% vs. 77%), low vs. high risk for recurrence persistent AF (90% vs. 72%), and permanent AF (20%). I-C drugs and amiodarone are preferred while dronedarone and sotalol barely used. Ablation is the first-line therapy for symptomatic paroxysmal AF (69%) and persistent AF with markers of atrial disease (57%) and is performed independently of symptoms by 15%. In persistent AF, 68% performs only pulmonary vein isolation and 32% also additional lesions. CONCLUSION: There is marked heterogeneity in AF management and limited accordance to last guidelines in the EHRA community. Most of the discrepancies are related to the main controversial issues, such as those related to AF screening, management of comorbidities, pharmacological treatment, and ablation strategy.
Asunto(s)
Fibrilación Atrial , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/terapia , Comorbilidad , Encuestas y Cuestionarios , Sotalol , Anticoagulantes/uso terapéutico , Resultado del TratamientoRESUMEN
AIMS: Arrhythmia-induced cardiomyopathy (AiCM) represents a subtype of acute heart failure (HF) in the context of sustained arrhythmia. Clear definitions and management recommendations for AiCM are lacking. The European Heart Rhythm Association Scientific Initiatives Committee (EHRA SIC) conducted a survey to explore the current definitions and management of patients with AiCM among European and non-European electrophysiologists. METHODS AND RESULTS: A 25-item online questionnaire was developed and distributed among EP specialists on the EHRA SIC website and on social media between 4 September and 5 October 2023. Of the 206 respondents, 16% were female and 61% were between 30 and 49 years old. Most of the respondents were EP specialists (81%) working at university hospitals (47%). While most participants (67%) agreed that AiCM should be defined as a left ventricular ejection fraction (LVEF) impairment after new onset of an arrhythmia, only 35% identified a specific LVEF drop to diagnose AiCM with a wide range of values (5-20% LVEF drop). Most respondents considered all available therapies: catheter ablation (93%), electrical cardioversion (83%), antiarrhythmic drugs (76%), and adjuvant HF treatment (76%). A total of 83% of respondents indicated that adjuvant HF treatment should be started at first HF diagnosis prior to antiarrhythmic treatment, and 84% agreed it should be stopped within six months after LVEF normalization. Responses for the optimal time point for the first LVEF reassessment during follow-up varied markedly (1 day-6 months after antiarrhythmic treatment). CONCLUSION: This EHRA Survey reveals varying practices regarding AiCM among physicians, highlighting a lack of consensus and heterogenous care of these patients.
Asunto(s)
Arritmias Cardíacas , Cardiomiopatías , Humanos , Arritmias Cardíacas/terapia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatología , Femenino , Masculino , Cardiomiopatías/terapia , Cardiomiopatías/diagnóstico , Cardiomiopatías/fisiopatología , Persona de Mediana Edad , Adulto , Europa (Continente) , Encuestas y Cuestionarios , Volumen Sistólico , Encuestas de Atención de la Salud , Antiarrítmicos/uso terapéutico , Pautas de la Práctica en Medicina/estadística & datos numéricos , Función Ventricular Izquierda , Ablación por Catéter , CardiólogosRESUMEN
AIMS: Pericardial tamponade (PT) is the most frequent severe complication during electrophysiology (EP) procedures and requires immediate, co-ordinated, and effective treatment. However, multiple aspects of PT treatment are either not standardized or are under ongoing debate. METHODS AND RESULTS: An online questionnaire consisting of 26 multiple-choice questions was sent out to the European Heart Rhythm (EHRA) Research Network and also distributed via social media outputs. The EHRA survey was conducted between May and June 2023. A total of 213 replies were received from European (87%) and non-European countries. Ninety per cent of all participants perform interventions in dedicated EP labs equipped with different ablation platforms. In case of PT, most participants use X-ray as the main imaging modality guiding pericardial puncture, predominantly aiming for an anterior puncture site. Sheaths of different sizes are introduced into the pericardial space (84.3%), followed by a pigtail catheter. Application of protamine is an established but variable step in the majority (84.6%). Novel oral anticoagulants (NOAC) antidotes are not used by 73.3% of participants, while 15.2% routinely apply them. Re-transfusion of aspirated blood is performed by 72.1% [before protamine administration (18.2%), after protamine administration (13.5%), if pericardial effusion cannot be controlled (40.4%)]. A total of 72.4% re-transfuse without blood filter systems. A decision for surgical intervention is mostly taken if bleeding continues despite all interventional measures. CONCLUSION: The current survey demonstrates that the management of PT is heterogeneous among centres. The findings of this survey may help to guide operators in their treatment and decisions in the setting of PT.
Asunto(s)
Anticoagulantes , Taponamiento Cardíaco , Humanos , Anticoagulantes/uso terapéutico , Taponamiento Cardíaco/diagnóstico por imagen , Taponamiento Cardíaco/etiología , Taponamiento Cardíaco/prevención & control , Encuestas y Cuestionarios , Protaminas , ElectrofisiologíaRESUMEN
AIMS: Patients with atrial fibrillation who despite taking oral anti-coagulant therapy (OAT) suffer a stroke or systemic embolism (SSE) without vascular cause or who develop left atrial appendage (LAA) thrombus (LAAT) should be considered as having malignant LAA. The optimal treatment strategy to reduce SSE risk in such patients is unknown. The aim of the study is to investigate the diagnostic and therapeutic pathways for malignant LAA practiced in European cardiac centres. METHODS AND RESULTS: An 18-item online questionnaire on malignant LAA was disseminated by the European Heart Rhythm Association (EHRA) Scientific Initiatives Committee. A total of 196 physicians participated in the survey. There seems to be high confidence in transoesophageal echocardiography (TEE) imaging, considering LAAT diagnosis. Switching to another direct oral anti-coagulant (DOAC) is the preferred initial step for the treatment of malignant LAA followed by a switch to vitamin K antagonist (VKA), low-molecular-weight heparin, or continued/optimized DOAC dosage, whereas LAA closure is the last option. Left atrial appendage closure is a viable option in patients with embolic stroke despite OAT and no evidence of thrombus at TEE (empty LAA) after comprehensive diagnostic measures to exclude other sources of embolism. CONCLUSION: This EHRA survey provides a snapshot of the contemporary management of patients diagnosed with malignant LAA. Currently, the majority of patients are treated on an outpatient basis with either shifting from VKA to DOAC or from one DOAC to another. Left atrial appendage closure in this population seems to be reserved for patients with higher bleeding risk or complications of malignant LAA, such as stroke.
Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Embolia , Cardiopatías , Accidente Cerebrovascular , Trombosis , Humanos , Apéndice Atrial/diagnóstico por imagen , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/tratamiento farmacológico , Accidente Cerebrovascular/prevención & control , Accidente Cerebrovascular/complicaciones , Anticoagulantes/uso terapéutico , Ecocardiografía Transesofágica , Trombosis/epidemiología , Fibrinolíticos/uso terapéutico , Encuestas y Cuestionarios , Resultado del TratamientoRESUMEN
AIMS: Electrophysiology (EP) is a growing field in cardiology, with an increasing involvement of young people. Nevertheless, concerns about radiation exposure and its impact on reproduction and pregnancy may discourage the choice of an EP career. The study is aimed at investigating the level of awareness and main sources of concern about the effects of radiation on reproductive potential and pregnancy, exploring the safety measures adopted in different EP labs, and verifying the adherence to the current guidelines. METHODS AND RESULTS: An online survey was conducted using the European Heart Rhythm Association (EHRA) infrastructure from April to June 2022. A total of 252 EP personnel (42% women) participated, from 50 countries and different professional roles. Most participants expressed concerns regarding the effects of radiation on reproductive capacity (67.1%) and offspring diseases (68.2%). Only 37.9% of participants were aware of the EHRA 2017 consensus document about occupational radiation exposure. Most participants (80.9%) considered that occupational radiation during pregnancy is not safe. EP female staff were not allowed to work in the EP lab during pregnancy in 48.1% of cases. Zero-fluoroscopy was the preferred choice to continue working in the EP lab during pregnancy. CONCLUSION: EP staff, including both men and women, have concerns about the effects of radiation on reproductive capacity. Despite the recommendations issued by international bodies, implementation of the policies regarding pregnancy and occupational radiation exposure is heterogeneous. Zero-fluoroscopy is the preferred approach to ensure safety during pregnancy in the EP lab.
Asunto(s)
Exposición Profesional , Exposición a la Radiación , Traumatismos por Radiación , Masculino , Embarazo , Femenino , Humanos , Adolescente , Exposición a la Radiación/efectos adversos , Exposición a la Radiación/prevención & control , Encuestas y Cuestionarios , Reproducción , Electrofisiología Cardíaca , Exposición Profesional/efectos adversos , Exposición Profesional/prevención & control , Dosis de RadiaciónRESUMEN
BACKGROUND: The traditional technique for subcutaneous implantable cardioverter defibrillator (S-ICD) implantation involves three incisions and a subcutaneous (SC) pocket. An intermuscular (IM) 2-incision technique has been recently adopted. AIMS: We assessed acute defibrillation efficacy (DE) of S-ICD (DE ≤65 J) according to the implantation technique. METHODS: We analyzed consecutive patients who underwent S-ICD implantation and DE testing at 53 Italian centers. Regression analysis was used to determine the association between DFT and implantation technique. RESULTS: A total of 805 patients were enrolled. Four groups were assessed: IM + 2 incisions (n = 546), SC + 2 incisions (n = 133), SC + 3 incisions (n = 111), and IM + 3 incisions (n = 15). DE was ≤65 J in 782 (97.1%) patients. Patients with DE ≤65 J showed a trend towards lower body mass index (25.1 vs. 26.5; p = .12), were less frequently on antiarrhythmic drugs (13% vs. 26%; p = .06) and more commonly underwent implantation with the 2-incision technique (85% vs. 70%; p = .04). The IM + 2-incision technique showed the lowest defibrillation failure rate (2.2%) and shock impedance (66 Ohm, interquartile range: 57-77). On multivariate analysis, the 2-incision technique was associated with a lower incidence of shock failure (hazard ratio: 0.305; 95% confidence interval: 0.102-0.907; p = .033). Shock impedance was lower with the IM than with the SC approach (66 vs. 70 Ohm p = .002) and with the 2-incision than the 3-incision technique (67 vs. 72 Ohm; p = .006). CONCLUSIONS: In a large population of S-ICD patients, we observed a high defibrillation success rate. The IM + 2-incision technique provides lower shock impedance and a higher likelihood of successful defibrillation.
Asunto(s)
Desfibriladores Implantables , Índice de Masa Corporal , Cardioversión Eléctrica/efectos adversos , Impedancia Eléctrica , Humanos , Implantación de Prótesis/efectos adversos , Tejido Subcutáneo , Resultado del TratamientoRESUMEN
BACKGROUND: Time-to-isolation (TTI) guided second-generation cryoballoon (CB2) ablation has been shown to be effective for pulmonary vein isolation (PVI). OBJECTIVE: The objective of this paper is to compare the safety and clinical outcome of CB2 PVI using the TTI guided 4 minutes vs 3 minutes freeze protocol. METHODS: This was a propensity-matched study based on an institutional database. Symptomatic atrial fibrillation (AF) patients who underwent CB2 PVI and systematic follow-up were consecutively included. RESULTS: A total of 573 patients were identified, of them 214 (107 matched-pairs) symptomatic AF (paroxysmal AF: 61%, persistent AF: 39%) patients (age: 67.7 ± 11.2 years) were analyzed. The baseline characteristics were comparable between the two groups. Procedural time was significantly longer in the 4 minutes group compared to 3 minutes group (67.2 ± 21.8 vs 55.9 ± 16.9 minutes, P < .0001). During a mean follow-up of 2 years, the 4 minutes group was associated with a significantly higher rate of freedom from arrhythmia recurrence compared with the 3 minutes group (66.4% vs 56.1%, P = .009), which was mainly driven by patients with persistent AF. The multivariate regression showed that the 4 minutes freeze was the independent predictor of freedom from arrhythmia recurrence. During the repeat procedure, the 4 minutes group was associated with a significantly higher rate of durable PVI. There was no difference regarding procedural adverse events between the two groups. CONCLUSION: As compared with the 3 minutes freeze, the TTI guided 4 minutes freeze is associated with a significantly higher rate of arrhythmia-free and durable PVI without compromising the safety profile, patients with persistent AF may benefit from the TTI guided 4 minutes freeze more pronouncedly.
Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Criocirugía/efectos adversos , Humanos , Venas Pulmonares/cirugía , Recurrencia , Factores de Tiempo , Resultado del TratamientoRESUMEN
INTRODUCTION: Pulmonary vein isolation (PVI) is the cornerstone ablation strategy for treatment of atrial fibrillation (AF). Ablation outside the PVs is sometimes needed particularly in persistent or longstanding AF. This study reported left atrial appendage isolation (LAAI) using cryoballoon (CB) focusing on technical data and short-term clinical follow-up. METHODS AND RESULTS: Patients with recurrent persistent AF after multiple AF procedures were enrolled. LAAI was performed using the second generation CB guided by compound motor action potential (CMAP) and 240 seconds plus bonus freeze (ICE-B) protocol. Ten patients were included, median age was 69.5 (56-73) years, CHA2 DS 2 -VASc score was 3 (1.8-4), LA diameter was 44 (38.8-46.5) mm. All patients had a mean of three AF procedures before the LAAI procedure. All patients were under successful CMAP guidance. During the CB LAAI procedure, the median time to LAA isolation was 100 (76-270) seconds, minimal freeze temperature was -50 (-57 to -47)°C. A "pull-down (or pull-away)" CB maneuver was performed in all patients. Median fluoroscopic time was 4.8 (3.4-6.8) minutes and acute LAAI success rate was 100%. No phrenic nerve injury or other major complications were observed. At 6-week follow-up, remapping of the LAA showed durable isolation of all PVs (100%), all patients were scheduled for LAA occlusion. Six-month follow-up showed that 80% of patients were free from AF/AT recurrence. CONCLUSION: CMAP plus ICE-B guided LAAI using cryo-technology appears feasible and safe, results in durable LAAI, and shows promising clinical results in patients with recurrent persistent AF.
Asunto(s)
Apéndice Atrial/cirugía , Fibrilación Atrial/cirugía , Criocirugía/métodos , Diafragma/inervación , Potenciales Evocados Motores , Monitorización Neurofisiológica Intraoperatoria/métodos , Potenciales de Acción , Anciano , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Criocirugía/efectos adversos , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Recurrencia , Factores de Tiempo , Resultado del TratamientoRESUMEN
BACKGROUND: Radiofrequency high-power ablation appears to be a novel concept for atrial fibrillation (AF). The ablation index (AI) value has been associated with durability of pulmonary vein isolation (PVI). OBJECTIVES: This study aimed to report the procedural data and initial results of a combined ablation technique using AI-guided high-power (AI-HP; 50 W) ablation for PVI. METHODS: Symptomatic AF patients were consecutively enrolled and underwent wide-area contiguous circumferential PVI. Contact-force catheters were used, ablation power was set to 50 W targeting AI values (550 anterior and 400 posterior). Esophageal temperature was monitored during procedure, all patients underwent postablation esophageal endoscopy. RESULTS: PVI was achieved in all (n = 50, mean age: 68 ± 9 years, female: 60%) patients, rate of first-round PVI was 92%. A total of N = 2105 AI-guided ablation lesions were analyzed. Comparing left anterior wall vs left posterior wall and right anterior wall vs right posterior wall, mean ablation time (s) per lesion was 20.5 ± 8 vs 8.6 ± 3 and 12.2 ± 4 vs 9.3 ± 3; mean contact force (g): 17.1 ± 12 vs 25.4 ± 14 and 33.7 ± 13 vs 21.0 ± 11; mean AI: 547 ± 48 vs 445 ± 55 and 555 ± 56 vs 440 ± 47 (all P < .0001). Procedure and fluoroscopy time (minute) were 55.6 ± 6.6 and 6 ± 1.7, respectively. Only one (2%) patient had a minimal esophageal lesion. During In-hospital and 1-month follow-up no major complications such as death, stroke, tamponade, or atriaesophageal fistula (AE) occurred. Preliminary 6-month follow-up showed 48 of 50 (96%) patients were free from clinical AF/atrial tachycardia recurrence. CONCLUSION: AI-HP (50 W) ablation appears to be a feasible, safe, fast, and effective ablation technique for PVI.
Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter , Venas Pulmonares/cirugía , Potenciales de Acción , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Estudios de Factibilidad , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Venas Pulmonares/fisiopatología , Recurrencia , Factores de Tiempo , Resultado del TratamientoRESUMEN
BACKGROUND: It remains unclear whether left atrial low-voltage area (LALVA) affects atrial tachyarrhythmia recurrence after laser balloon pulmonary vein isolation (PVI) for atrial fibrillation (AF). We prospectively evaluated the outcome of laser balloon PVI in patients with and without LALVA (≤ 0.5 mV) together with surface/intracardiac electrophysiological criteria. METHODS: One hundred consecutive paroxysmal/persistent AF patients underwent laser balloon PVI. The relative extent of LALVA (extent of LALVA/left atrial surface area × 100 [%]: rLALVA), total p-wave duration in lead II (PWD), and time interval from the beginning of p-wave to the local activation in left atrial appendage (TTLAA) were assessed. Patients were divided into patients with LALVA (group A: 23 patients) and those without LALVA (group B: 77 patients). The primary endpoint was freedom from atrial tachyarrhythmia after the blanking periods. RESULTS: Complete PVI was achieved in 99/100 (99%) patients. PWD and TTLAA were longer in group A (both, P < 0.001). During 12 months' follow-up, survival free from atrial tachyarrhythmia recurrence was lower in group A (12/23 [52%] patients vs 67/77 [87%] patients, P < 0.001). Multivariate analysis identified rLALVA as the only independent predictor of atrial tachyarrhythmia recurrence. rLALVA correlated with PWD and TTLAA (r = 0.41, P < 0.001 and r = 0.60, P < 0.001, respectively). Receiver operating characteristic curve for rLALVA revealed PWD of 122 ms and TTLAA of 92 ms as the optimal cut-off value. CONCLUSION: LALVA was associated with poorer outcome after laser balloon PVI. Patients may be identified by longer PWD and TTLAA.
Asunto(s)
Fibrilación Atrial/cirugía , Terapia por Láser/métodos , Venas Pulmonares/cirugía , Anciano , Fibrilación Atrial/fisiopatología , Electrocardiografía , Femenino , Atrios Cardíacos , Sistema de Conducción Cardíaco/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Recurrencia , Resultado del TratamientoRESUMEN
BACKGROUND: The procedural data of pulmonary vein (PV) isolation (PVI) for patients with atrial fibrillation using the second-generation laser balloon (LB2), which became available recently, remains unclear and were evaluated. METHODS: Thirty consecutive patients (116 PVs) underwent PVI using LB2 (LB2 group) and were matched to 30 patients (116 PVs) treated with the first-generation laser balloon (LB1 group). The left atrial isolated surface area (ISA) (ratio of the total isolated antral surface area excluding PV to the total isolated antral surface area including the posterior wall) was also measured after LB2 PVI. RESULTS: PVI was achieved in 103/116 (89%) PVs and 108/116 (93%) PVs in the LB2 and LB1 groups, respectively, after the initial circular ablation (P = 0.360) and in 115/116 (99%) PVs and 116/116 (100%) PVs in the LB2 and LB1 groups, respectively, at the end of the procedure (P = 1.000). PV occlusion grade, categorized by the degree of PV occlusion, was significantly better in the LB2 group than in the LB1 group (P < 0.001). Zero rotational maneuver was applicable in 23/116 (20%) PVs and 8/116 (7%) in the LB2 and LB1 groups, respectively (P = 0.007). There was no significant difference in the procedural time, fluoroscopic time, or complications. The mean ISA after LB2 PVI was 53 ± 14%. The application number was the only independent predictor of successful PVI after initial circular LB2 ablation (adjusted odds ratio 0.860; 95% confidence interval 0.764-0.968; P = 0.013). CONCLUSION: LB2 displays favorable PV occlusion characteristics and enables more zero rotational maneuvers.
Asunto(s)
Fibrilación Atrial/cirugía , Oclusión con Balón/métodos , Terapia por Láser/métodos , Venas Pulmonares/cirugía , Anciano , Electrocardiografía , Femenino , Humanos , MasculinoRESUMEN
BACKGROUND: The left atrial appendage (LAA) has been identified as a potential source of atrial fibrillation (AF) and has been described as the "fifth" pulmonary vein (PV). We report our initial experience in LAA isolation (LAAI) using the cryoballoon (CB) and data on durability of CB-LAAI. METHODS: Patients treated with a CB-LAAI were retrospectively identified. Six weeks after electrical LAAI, patients were scheduled for staged percutaneous LAA closure. During the second procedure, a subset of patients underwent invasive remapping of the LAA. RESULTS: A total of 32 patients (21 males, 68 ± 10 years old) were treated with CB-LAAI. Acute LAAI was achieved in 29 of 32 (91%) patients: single-shot LAAI was observed in 18 of 32 (56%) patients. Acute procedural sustained LAAI was related with a significantly shorter time to LAAI (sustained LAAI: 84 ± 50 s vs nonsustained LAAI: 166 ± 76 s, P = 0.004). Mean procedure and fluoroscopy time were 61 ± 29 and 8 ± 6 min, respectively. One left-sided phrenic nerve palsy occurred. In 25 of 32 (78%) patients, a second procedure for percutaneous LAA closure device implantation was performed. In 22 patients, persistency of LAAI was tested: durable LAAI was documented in 16/22 patients (73%). CONCLUSION: In the present report, CB LAA isolation followed by staged LAA closure appeared to be safe and feasible but more data are required. Time to LAAI played a role in predicting acute sustained LAAI rate. CB LAA ablation leads to 73% of durable LAA isolation.
Asunto(s)
Apéndice Atrial/cirugía , Fibrilación Atrial/cirugía , Criocirugía/métodos , Anciano , Mapeo Epicárdico , Femenino , Humanos , Masculino , Estudios RetrospectivosRESUMEN
Atrial fibrillation (AF) affects 1-2% of the population, and its prevalence is estimated to double in the next 50 years as the population ages. AF results in impaired patients' life quality, deteriorated cardiac function, and even increased mortality. Antiarrhythmic drugs frequently fail to restore sinus rhythm. Catheter ablation is a valuable treatment approach for AF, even as a first-line therapy strategy in selected patients. Effective electrical pulmonary vein isolation (PVI) is the cornerstone of all AF ablation strategies. Use of radiofrequency (RF) catheter in combination of a three-dimensional electroanatomical mapping system is the most established ablation approach. However, catheter ablation of AF is challenging even sometimes for experienced operators. To facilitate catheter ablation of AF without compromising the durability of the pulmonary vein isolation, "single shot" ablation devices have been developed; of them, cryoballoon ablation, is by far the most widely investigated. In this report, we review the current knowledge of AF and discuss the recent evidence in catheter ablation of AF, particularly cryoballoon ablation. Moreover, we review relevant data from the literature as well as our own experience and summarize the key procedural practical techniques in PVI using cryoballoon technology, aiming to shorten the learning curve of the ablation technique and to contribute further to reduction of the disease burden.
Asunto(s)
Fibrilación Atrial/cirugía , Criocirugía , Venas Pulmonares/cirugía , Potenciales de Acción , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/mortalidad , Fibrilación Atrial/fisiopatología , Catéteres Cardíacos , Criocirugía/efectos adversos , Criocirugía/instrumentación , Criocirugía/mortalidad , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Diseño de Equipo , Frecuencia Cardíaca , Humanos , Flebografía , Complicaciones Posoperatorias/etiología , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/fisiopatología , Factores de Riesgo , Resultado del TratamientoRESUMEN
BACKGROUND: The LAmbre™ occluder is a novel device for percutaneous left atrial appendage closure (LAAC). The presented study aimed to report the initial experience in implantation of the novel LAmbre for LAAC in patients with nonvalvular AF. METHODS: We conducted a prospective, observational, cohort registry study to evaluate the feasibility of percutaneous LAAC using the LAmbre system. RESULTS: Thirty patients (15 female, mean age 77.6 ± 8.9 years) who had high risks of stroke and contraindications for oral anticoagulation were prospectively enrolled in this registry study. The mean CHA2DS2-VaSc was 3.9 ± 1.5, and the mean HAS-BLED score was 4.1 ± 1.0. Twenty (66.7%) patients had chicken-wing LAA morphology. The implant success rate was 100%. The mean fluoroscopic time and procedure time were 3.5 ± 1.9 and 29.0 ± 10.1 minutes, respectively. No significant procedure-related complications were observed during in-hospital and acute clinical follow-up. CONCLUSION: In this preliminary study, the LAmbre occluder showed an excellent implant success rate, favorable implant property, and very low incidence of complications. Larger sample, randomized studies are further warranted.
Asunto(s)
Apéndice Atrial/fisiopatología , Fibrilación Atrial/terapia , Cateterismo Cardíaco/instrumentación , Potenciales de Acción , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Cateterismo Cardíaco/efectos adversos , Angiografía Coronaria , Ecocardiografía Transesofágica , Diseño de Equipo , Estudios de Factibilidad , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Datos Preliminares , Estudios Prospectivos , Sistema de Registros , Factores de Tiempo , Resultado del TratamientoRESUMEN
Aims: The long-term outcomes of left atrial appendage electrical isolation (LAAEI) in patients with non-paroxysmal atrial fibrillation (AF) have corroborated the significant role of the LAA in this arrhythmia. We sought to investigate the incremental benefit of LAAEI in patients undergoing catheter ablation for persistent AF or long-standing persistent AF (LSPAF). Methods and results: A systematic review of Medline, Cochrane, and Embase for all the clinical studies in which assessment LAAEI in non-paroxysmal AF patients was performed. The benefit of LAAEI in patients with AF was analysed from seven studies that enrolled a total of 930 patients [mean age 63 ± 5 years; male: 69%]. All studies included patients with either persistent AF or LSPAF or the combination of them. The overall freedom from all-arrhythmia recurrence at 12 months of follow-up off antiarrhythmic medications in patients who underwent LAAEI was 75.5% vs. 43.9% in those in whom only standard ablation was performed [56% relative reduction and 31.6% absolute reduction; risk ratio (RR) 0.44, 95% confidence interval (95% CI) 0.31-0.64; P < 0.0001]. The rate of ischaemic stroke in the LAAEI group was 0.4% and in the control group 2.1% at 12 months follow-up (RR 0.40, 95% CI 0.12-1.30; P = 0.13). Acute complications rates were identical between groups [LAAEI 5.5%, control 5.5% (RR 0.99, 95% CI 0.46-2.16; P = 0.99)]. Conclusion: Left atrial appendage electrical isolation in addition to standard ablation appears to have a substantial incremental benefit to achieve freedom from ALL atrial arrhythmias in patients with persistent AF and LSPAF without increasing acute procedural complications and without raising the risk of ischaemic stroke.
Asunto(s)
Apéndice Atrial/cirugía , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Potenciales de Acción , Anciano , Apéndice Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/fisiopatología , Isquemia Encefálica/epidemiología , Isquemia Encefálica/prevención & control , Ablación por Catéter/efectos adversos , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Supervivencia sin Progresión , Recurrencia , Factores de Riesgo , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/prevención & control , Factores de Tiempo , Resultado del TratamientoRESUMEN
BACKGROUND: The incidence of pulmonary vein stenosis (PVS) after AF ablation following contemporary procedures remains unclear. We compared the incidence of PVS/narrowing (PVS/N) after PV isolation (PVI) for (1) 3-D mapping-guided wide-area encircling irrigated radiofrequency current (RFC) ablation; (2) first-third-generation big cryoballoon (CB1-3) ablation; and (3) laser balloon (LB) ablation.MethodsâandâResults:All patients undergoing a second procedure between January 2012 and November 2016 were subgrouped according to index ablation (PVI): RFC; CB; or LB. PVS/N was classified using PV diameter ratio (second/index procedure) on selective PV angiogram performed before ablation: mild, 25-49%; moderate, 50-74%; or severe, ≥75%. A total of 344 patients (1,362 PV) were analyzed (RFC, n=211; 840 PV; CB1, n=21; 82 PV; CB2,3, n=64; 250 PV; LB, n=48; 190 PV). In the LB group, 45 patients (94%) were treated with dose ≥8.5 W. Second procedures were performed on average 14.9±14.1 months after the index procedure. Mild PVS/N was observed in 18.4%, 9.5% and 3.6% of PV in the LB, RFC and CB groups, respectively (P<0.01). Moderate PVS was recognized in 2 PV (0.1%; RFC, LB). Severe PVS was never observed, and no PV intervention/surgery was required. CONCLUSIONS: The risk for significant PVS is low after RFC/CB. The incidence of mild PVS/N was highest after standard-dose LB ablation and lowest after high-dose CB ablation.
Asunto(s)
Técnicas de Ablación/normas , Fibrilación Atrial/terapia , Ablación por Catéter/métodos , Estenosis de Vena Pulmonar/etiología , Técnicas de Ablación/efectos adversos , Anciano , Angioplastia de Balón , Angioplastia de Balón Asistida por Láser , Fibrilación Atrial/complicaciones , Embolectomía con Balón , Ablación por Catéter/efectos adversos , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Venas Pulmonares/cirugía , Ablación por Radiofrecuencia , Riesgo , Resultado del TratamientoRESUMEN
INTRODUCTION: The ablation strategy for atrial fibrillation (AF) despite pulmonary vein isolation (PVI) is controversial. Left atrial appendage isolation (LAAI) may contribute to improve outcome. We describe an ablation approach ("Maze-like"-LAAI) that (1) modifies the underlying LA substrate by linear ablation (2) eliminates the LAA as a putative AF trigger site and (3) incorporates an unambiguous procedural endpoint. The role of LAA closure (LAAC) after LAAI was investigated. METHODS: Patients with atrial tachyarrhythmias nonresponsive to PVI underwent a LAAI ablation procedure. LAAI was achieved by combining (a) an anterior line, (b) a LA roof line and (c) a mitral isthmus line. Patients continued oral anticoagulation (OAC) therapy or underwent LAAC ≥6 weeks after LAAI. RESULTS: Maze-like LAAI was attempted in our center in 107 of 3,611 AF ablation procedures (2.9%) and achieved in 88 of 107 patients (82%). In 8 of 107 (7%) patients cardiac tamponade occurred, all managed conservatively. During follow-up sinus rhythm was established in 65% at 1 year. After LAAI, 45 patients remained on OAC and 40 underwent LAAC. In both groups 1 patient experienced a bleeding complication. Thromboembolism exclusively occurred in the OAC group in 3 (7%) patients. CONCLUSION: LAA isolation by Maze-like substrate modification may be considered a viable option for PVI non-responders. It offers a reproducible approach with an unambiguous procedural endpoint and leads to a favorable clinical outcome. However, extensive LA ablation increased the risk of tamponade. Consecutive LAA occlusion may offer a nonpharmacologic strategy to overcome the high thromboembolic risk associated with absent mechanical LAA contraction.
Asunto(s)
Apéndice Atrial/cirugía , Fibrilación Atrial/cirugía , Mapeo del Potencial de Superficie Corporal/métodos , Ablación por Catéter/normas , Catéteres , Guías de Práctica Clínica como Asunto , Venas Pulmonares/cirugía , Anciano , Apéndice Atrial/diagnóstico por imagen , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ablación por Catéter/instrumentación , Ecocardiografía Transesofágica , Electrocardiografía Ambulatoria , Diseño de Equipo , Femenino , Estudios de Seguimiento , Humanos , Imagenología Tridimensional , Masculino , Reproducibilidad de los Resultados , Estudios Retrospectivos , Resultado del TratamientoRESUMEN
BACKGROUND: Clinical outcome after pulmonary vein isolation (PVI) may be linked to both durability of PVI and the antral lesion size. Data on balloon-guided technologies are scarce. We investigated the size of the isolated surface area (ISA) acutely after PVI achieved by cryoballoon (CB) or laser balloon (LB), both using voltage mapping.MethodsâandâResults:In 40 patients (73% male, mean age 66±9 years), a bipolar voltage map before and after PVI in sinus rhythm was acquired to delineate the isolated antral surface area (IASA, contiguous area of low voltage <0.5 mV) and the ISA (relative size of the low-voltage area in relation to the whole antral surface area including the posterior wall). IASA (CB: 57±14 cm2vs. LB: 42±15 cm2; P=0.002) as well as ISA (65±8% vs. 54±10%; P=0.001) were significantly larger in the CB than in the LB group. No periprocedural complications occurred. During a mean follow-up of 326±142 days, 4/20 and 5/20 patients experienced an AF/AT recurrence in the CB and LB groups, respectively. No differences in clinical outcome were observed between patients with a large (≥55%) or small (<55%) ISA. CONCLUSIONS: Balloon-guided PVI is associated with antral lesion formation. CB-guided PVI is associated with the largest ISA as compared with LB procedures. ISA size did not correlate with clinical outcome after a single procedure in the present study population.
Asunto(s)
Angioplastia de Balón/métodos , Criocirugía/métodos , Venas Pulmonares/cirugía , Anciano , Angioplastia de Balón/efectos adversos , Angioplastia de Balón/normas , Fibrilación Atrial , Criocirugía/efectos adversos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Venas Pulmonares/patologíaRESUMEN
INTRODUCTION: QRS duration and morphology are currently recognized as recommended criteria for the selection of CRT candidates. It has recently been shown that patients with left bundle branch block (LBBB) derive substantial clinical benefit from CRT. The aim of this study is to investigate the prognostic impact of QRS axis deviation (AD) in HF patients with LBBB undergoing CRT. METHODS AND RESULTS: We retrospectively evaluated 707 HF patients with LBBB who underwent CRT at five centers. Baseline QRS axis was defined as normal (NA: -30° to 90°), right axis deviation (RAD: 90° to 180°) and left axis deviation (LAD: <-30°). The primary endpoint was a composite of all cause death/HF hospitalization. The risk of endpoint by AD was evaluated with both Kaplan-Meier and Cox proportional hazard analysis. Among 707 patients (73% M, median age: 71 [62,77] years), 323 (46%) had NA, 359 (51%) LAD, and 25 (3.5%) RAD. Baseline clinical characteristics were similar between the three groups. Over a mean follow-up of 32 ± 25 months, 141 deaths occurred (21%) and 36% (n = 255) met with the composite endpoint. A significantly higher proportion of RAD patients (52%) reached the endpoint (LAD 40%, NA 30%). KM analysis showed that RAD and LAD patients had worse event free survival and in multivariate analysis both LAD (HR: 1.40; 95% CI: 1.05-1.86; P = 0.021) and RAD (HR: 2.49; 95% CI: 1.31-4.74; P = 0.005) were independently associated with worse clinical outcome. CONCLUSIONS: Right or left axis deviation in the presence of LBBB in HF patients undergoing CRT are independent predictors of poor prognosis.