RESUMEN
BACKGROUND: Percutaneous coronary intervention (PCI) is frequently performed to reduce the symptoms of stable angina. Whether PCI relieves angina more than a placebo procedure in patients who are not receiving antianginal medication remains unknown. METHODS: We conducted a double-blind, randomized, placebo-controlled trial of PCI in patients with stable angina. Patients stopped all antianginal medications and underwent a 2-week symptom assessment phase before randomization. Patients were then randomly assigned in a 1:1 ratio to undergo PCI or a placebo procedure and were followed for 12 weeks. The primary end point was the angina symptom score, which was calculated daily on the basis of the number of angina episodes that occurred on a given day, the number of antianginal medications prescribed on that day, and clinical events, including the occurrence of unblinding owing to unacceptable angina or acute coronary syndrome or death. Scores range from 0 to 79, with higher scores indicating worse health status with respect to angina. RESULTS: A total of 301 patients underwent randomization: 151 to the PCI group and 150 to the placebo group. The mean (±SD) age was 64±9 years, and 79% were men. Ischemia was present in one cardiac territory in 242 patients (80%), in two territories in 52 patients (17%), and in three territories in 7 patients (2%). In the target vessels, the median fractional flow reserve was 0.63 (interquartile range, 0.49 to 0.75), and the median instantaneous wave-free ratio was 0.78 (interquartile range, 0.55 to 0.87). At the 12-week follow-up, the mean angina symptom score was 2.9 in the PCI group and 5.6 in the placebo group (odds ratio, 2.21; 95% confidence interval, 1.41 to 3.47; P<0.001). One patient in the placebo group had unacceptable angina leading to unblinding. Acute coronary syndromes occurred in 4 patients in the PCI group and in 6 patients in the placebo group. CONCLUSIONS: Among patients with stable angina who were receiving little or no antianginal medication and had objective evidence of ischemia, PCI resulted in a lower angina symptom score than a placebo procedure, indicating a better health status with respect to angina. (Funded by the National Institute for Health and Care Research Imperial Biomedical Research Centre and others; ORBITA-2 ClinicalTrials.gov number, NCT03742050.).
Asunto(s)
Angina Estable , Intervención Coronaria Percutánea , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Síndrome Coronario Agudo , Angina Estable/tratamiento farmacológico , Angina Estable/cirugía , Fármacos Cardiovasculares/uso terapéutico , Reserva del Flujo Fraccional Miocárdico , Estado de Salud , Intervención Coronaria Percutánea/métodos , Resultado del Tratamiento , Método Doble Ciego , Isquemia MiocárdicaRESUMEN
BACKGROUND: The Placebo-controlled Trial of Percutaneous Coronary Intervention for the Relief of Stable Angina (ORBITA-2) provided evidence for the role of percutaneous coronary intervention (PCI) for angina relief in stable coronary artery disease (CAD). Fractional flow reserve (FFR) and instantaneous wave-free ratio (iFR) are often used to guide PCI, however their ability to predict placebo-controlled angina improvement is unknown. METHODS: Participants with angina, ischemia, and stable CAD were enrolled and antianginal medications were stopped. Participants reported angina episodes daily for 2 weeks using the ORBITA-app. At the research angiogram, FFR and iFR were measured. After sedation and auditory isolation, participants were randomized to PCI or placebo, before entering a 12-week blinded follow-up phase with daily angina reporting. The ability of FFR and iFR, analyzed as continuous variables, to predict the placebo-controlled effect of PCI, was tested using Bayesian proportional odds modelling. RESULTS: Invasive physiology data were available in 279 patients (140 PCI and 139 placebo). The median (IQR) age was 65 years (59.0 to 70.5) and 223 (79.9%) were male. Median FFR was 0.60 (0.46 to 0.73) and median iFR was 0.76 (0.50 to 0.86). The lower the FFR or iFR, the greater the placebo-controlled improvement with PCI across all endpoints. There was strong evidence that a patient with an FFR at the lower quartile would have a greater placebo-controlled improvement in angina symptom score with PCI than a patient at the upper quartile (FFR 0.46 vs. 0.73: OR 2.01, 95% CrI 1.79 to 2.26, Pr(Interaction)>99.9%). Similarly, there was strong evidence that a patient with an iFR at the lower quartile would have a greater placebo controlled improvement in angina symptom score with PCI than a patient with an iFR at the upper quartile (iFR 0.50 vs. 0.86: OR 2.13, 95% CrI 1.87 to 2.45, Pr(Interaction) >99.9%). The relationship between benefit and physiology was seen in both Rose angina and Rose nonangina. CONCLUSIONS: Physiological stenosis severity, as measured by FFR and iFR, predicts placebo-controlled angina relief from PCI. Invasive coronary physiology can be used to target PCI to those patients who are most likely to experience benefit.
RESUMEN
BACKGROUND: The coronary sinus reducer (CSR) is proposed to reduce angina in patients with stable coronary artery disease by improving myocardial perfusion. We aimed to measure its efficacy, compared with placebo, on myocardial ischaemia reduction and symptom improvement. METHODS: ORBITA-COSMIC was a double-blind, randomised, placebo-controlled trial conducted at six UK hospitals. Patients aged 18 years or older with angina, stable coronary artery disease, ischaemia, and no further options for treatment were eligible. All patients completed a quantitative adenosine-stress perfusion cardiac magnetic resonance scan, symptom and quality-of-life questionnaires, and a treadmill exercise test before entering a 2-week symptom assessment phase, in which patients reported their angina symptoms using a smartphone application (ORBITA-app). Patients were randomly assigned (1:1) to receive either CSR or placebo. Both participants and investigators were masked to study assignment. After the CSR implantation or placebo procedure, patients entered a 6-month blinded follow-up phase in which they reported their daily symptoms in the ORBITA-app. At 6 months, all assessments were repeated. The primary outcome was myocardial blood flow in segments designated ischaemic at enrolment during the adenosine-stress perfusion cardiac magnetic resonance scan. The primary symptom outcome was the number of daily angina episodes. Analysis was done by intention-to-treat and followed Bayesian methodology. The study is registered with ClinicalTrials.gov, NCT04892537, and completed. FINDINGS: Between May 26, 2021, and June 28, 2023, 61 patients were enrolled, of whom 51 (44 [86%] male; seven [14%] female) were randomly assigned to either the CSR groupâ(n=25) or the placebo group (n=26). Of these, 50 patients were included in the intention-to-treat analysis (24 in the CSR group and 26 in the placebo group). 454 (57%) of 800 imaged cardiac segments were ischaemic at enrolment, with a median stress myocardial blood flow of 1·08 mL/min per g (IQR 0·77-1·41). Myocardial blood flow in ischaemic segments did not improve with CSR compared with placebo (difference 0·06 mL/min per g [95% CrI -0·09 to 0·20]; Pr(Benefit)=78·8%). The number of daily angina episodes was reduced with CSR compared with placebo (OR 1·40 [95% CrI 1·08 to 1·83]; Pr(Benefit)=99·4%). There were two CSR embolisation events in the CSR group, and no acute coronary syndrome events or deaths in either group. INTERPRETATION: ORBITA-COSMIC found no evidence that the CSR improved transmural myocardial perfusion, but the CSR did improve angina compared with placebo. These findings provide evidence for the use of CSR as a further antianginal option for patients with stable coronary artery disease. FUNDING: Medical Research Council, Imperial College Healthcare Charity, National Institute for Health and Care Research Imperial Biomedical Research Centre, St Mary's Coronary Flow Trust, British Heart Foundation.
Asunto(s)
Angina Estable , Enfermedad de la Arteria Coronaria , Seno Coronario , Intervención Coronaria Percutánea , Humanos , Masculino , Femenino , Enfermedad de la Arteria Coronaria/terapia , Angina Estable/tratamiento farmacológico , Seno Coronario/diagnóstico por imagen , Teorema de Bayes , Resultado del Tratamiento , Intervención Coronaria Percutánea/efectos adversos , Método Doble Ciego , Isquemia , AdenosinaRESUMEN
BACKGROUND: While it is broadly accepted that ageing is associated with impairment of coronary microvascular function, little is known about the underlying mechanisms. AIMS: We investigated age-related changes in coronary microvascular structure in patients with stable angina without epicardial coronary stenoses. METHODS: In an analysis of the IDEAL registry, a total of 165 vessels without coronary stenosis were interrogated with combined pressure/Doppler guidewires. We calculated diastolic microvascular conductance (DMVC) and backward expansion wave (BEW), and compared them between age tertiles. We calculated the prevalence of CMD, defined by reduced coronary flow reserve (CFR), and the prevalence of low BEW and low DMVC in each group. RESULTS: The three study groups were defined as having 37-53, 54-66, and 67-77 years of age, respectively. Oldest (3rd tertile) patients showed lower hyperemic flow velocity (46.7 ± 14.4 vs. 45.1 ± 12.4 vs. 38.4 ± 11.5 cm s-1, p = 0.019), lower DMVC (1.90 ± 0.71 vs. 1.44 ± 0.56 vs. 1.37 ± 0.67 cm s-1 mmHg-1, p < 0.001) and lower BEW intensity (5.9 [2.9-8.4] vs. 4.8 [2.9-6.8] vs. 4.4 [3.4-6.3] × 106 W m-2 s-1, p = 0.094). Older age was independently associated with lower BEW intensity (B: -0.10, 95% confidence interval [CI]: -0.17 to -0.09, p = 0.021) and DMVC (B: -0.25 95% CI: -0.45 to -0.09, p = 0.027). In patients with CFR < 2.5, the prevalence of BEW intensity and DMVC below the 25th percentile increased with age (25.0% vs. 52.0% vs. 72.7%, p = 0.010). CONCLUSIONS: Ageing is independently associated with structural microcirculatory remodeling that is reflected in BEW intensity and DMVC measurements, and with an increased prevalence of structural CMD. These results are important to understand non-obstructive mechanisms of myocardial ischemia in the elderly.
RESUMEN
AIMS: This meta-analysis aims to quantify the association of reduced coronary flow with all-cause mortality and major adverse cardiovascular events (MACE) across a broad range of patient groups and pathologies. METHODS AND RESULTS: We systematically identified all studies between 1 January 2000 and 1 August 2020, where coronary flow was measured and clinical outcomes were reported. The endpoints were all-cause mortality and MACE. Estimates of effect were calculated from published hazard ratios (HRs) using a random-effects model. Seventy-nine studies with a total of 59 740 subjects were included. Abnormal coronary flow reserve (CFR) was associated with a higher incidence of all-cause mortality [HR: 3.78, 95% confidence interval (CI): 2.39-5.97] and a higher incidence of MACE (HR 3.42, 95% CI: 2.92-3.99). Each 0.1 unit reduction in CFR was associated with a proportional increase in mortality (per 0.1 CFR unit HR: 1.16, 95% CI: 1.04-1.29) and MACE (per 0.1 CFR unit HR: 1.08, 95% CI: 1.04-1.11). In patients with isolated coronary microvascular dysfunction, an abnormal CFR was associated with a higher incidence of mortality (HR: 5.44, 95% CI: 3.78-7.83) and MACE (HR: 3.56, 95% CI: 2.14-5.90). Abnormal CFR was also associated with a higher incidence of MACE in patients with acute coronary syndromes (HR: 3.76, 95% CI: 2.35-6.00), heart failure (HR: 6.38, 95% CI: 1.95-20.90), heart transplant (HR: 3.32, 95% CI: 2.34-4.71), and diabetes mellitus (HR: 7.47, 95% CI: 3.37-16.55). CONCLUSION: Reduced coronary flow is strongly associated with increased risk of all-cause mortality and MACE across a wide range of pathological processes. This finding supports recent recommendations that coronary flow should be measured more routinely in clinical practice, to target aggressive vascular risk modification for individuals at higher risk.
Asunto(s)
Síndrome Coronario Agudo , Sistema Cardiovascular , Enfermedad de la Arteria Coronaria , Reserva del Flujo Fraccional Miocárdico , Isquemia Miocárdica , Humanos , Pronóstico , Modelos de Riesgos ProporcionalesRESUMEN
AIMS: Oxygen-pulse morphology and gas exchange analysis measured during cardiopulmonary exercise testing (CPET) has been associated with myocardial ischaemia. The aim of this analysis was to examine the relationship between CPET parameters, myocardial ischaemia and anginal symptoms in patients with chronic coronary syndrome and to determine the ability of these parameters to predict the placebo-controlled response to percutaneous coronary intervention (PCI). METHODS AND RESULTS: Patients with severe single-vessel coronary artery disease (CAD) were randomized 1:1 to PCI or placebo in the ORBITA trial. Subjects underwent pre-randomization treadmill CPET, dobutamine stress echocardiography (DSE) and symptom assessment. These assessments were repeated at the end of a 6-week blinded follow-up period.A total of 195 patients with CPET data were randomized (102 PCI, 93 placebo). Patients in whom an oxygen-pulse plateau was observed during CPET had higher (more ischaemic) DSE score [+0.82 segments; 95% confidence interval (CI): 0.40 to 1.25, P = 0.0068] and lower fractional flow reserve (-0.07; 95% CI: -0.12 to -0.02, P = 0.011) compared with those without. At lower (more abnormal) oxygen-pulse slopes, there was a larger improvement of the placebo-controlled effect of PCI on DSE score [oxygen-pulse plateau presence (Pinteraction = 0.026) and oxygen-pulse gradient (Pinteraction = 0.023)] and Seattle angina physical-limitation score [oxygen-pulse plateau presence (Pinteraction = 0.037)]. Impaired peak VO2, VE/VCO2 slope, peak oxygen-pulse, and oxygen uptake efficacy slope was significantly associated with higher symptom burden but did not relate to severity of ischaemia or predict response to PCI. CONCLUSION: Although selected CPET parameters relate to severity of angina symptoms and quality of life, only an oxygen-pulse plateau detects the severity of myocardial ischaemia and predicts the placebo-controlled efficacy of PCI in patients with single-vessel CAD.
Asunto(s)
Angina Estable , Enfermedad de la Arteria Coronaria , Reserva del Flujo Fraccional Miocárdico , Intervención Coronaria Percutánea , Angina Estable/diagnóstico , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/terapia , Prueba de Esfuerzo/métodos , Humanos , Oxígeno , Consumo de Oxígeno/fisiología , Calidad de VidaRESUMEN
BACKGROUND: The pressure-derived parameters fractional flow reserve (FFR) and the emerging instantaneous wave-free ratio (iFR) are the most widely applied invasive coronary physiology indices to guide revascularisation. However, approximately 15-20% of intermediate stenoses show discordant FFR and iFR, and therapeutical consensus is lacking. AIMS: We sought to associate hyperaemic stenosis resistance index, coronary flow reserve (CFR) and coronary flow capacity (CFC) to FFR/iFR discordance. METHODS: We assessed pressure and flow measurements of 647 intermediate lesions (593 patients) of two multi-centre international studies. RESULTS: FFR and iFR were discordant in 15% of all lesions (97 out of 647). FFR+/iFR- lesions had similar hyperaemic average peak velocity (hAPV), CFR and CFC as FFR-/iFR- lesions, whereas FFR-/iFR+ lesions had similar hAPV, CFR and CFC as FFR+/iFR+ lesions (pâ¯> 0.05 for all). FFR+/iFR- lesions were associated with lower baseline stenosis resistance, but not hyperaemic stenosis resistance, compared with FFR-/iFR+ lesions (pâ¯< 0.001). CONCLUSIONS: Discordance with FFR+/iFR- is characterised by maximal flow values, CFR, and CFC patterns similar to FFR-/iFR- concordance that justifies conservative therapy. Discordance with FFR-/iFR+ on the other hand, is characterised by low flow values, CFR, and CFC patterns similar to iFR+/FFR+ concordance that may benefit from percutaneous coronary intervention.
RESUMEN
The COVID-19 pandemic has altered our approach to inpatient echocardiography delivery. There is now a greater focus to address key clinical questions likely to make an immediate impact in management, particularly during the period of widespread infection. Handheld echocardiography (HHE) can be used as a first-line assessment tool, limiting scanning time and exposure to high viral load. This article describes a potential role for HHE during a pandemic. We propose a protocol with a reporting template for a focused core dataset necessary in delivering an acute echocardiography service in the setting of a highly contagious disease, minimising risk to the operator. We cover the scenarios typically encountered in the acute cardiology setting and how an expert trained echocardiography team can identify such pathologies using a limited imaging format and include cardiac presentations encountered in those patients acutely unwell with COVID-19.
Asunto(s)
COVID-19 , Cardiología , Ecocardiografía , Humanos , Pandemias , SARS-CoV-2RESUMEN
BACKGROUND: Dobutamine stress echocardiography is widely used to test for ischemia in patients with stable coronary artery disease. In this analysis, we studied the ability of the prerandomization stress echocardiography score to predict the placebo-controlled efficacy of percutaneous coronary intervention (PCI) within the ORBITA trial (Objective Randomised Blinded Investigation With Optimal Medical Therapy of Angioplasty in Stable Angina). METHODS: One hundred eighty-three patients underwent dobutamine stress echocardiography before randomization. The stress echocardiography score is broadly the number of segments abnormal at peak stress, with akinetic segments counting double and dyskinetic segments counting triple. The ability of prerandomization stress echocardiography to predict the placebo-controlled effect of PCI on response variables was tested by using regression modeling. RESULTS: At prerandomization, the stress echocardiography score was 1.56±1.77 in the PCI arm (n=98) and 1.61±1.73 in the placebo arm (n=85). There was a detectable interaction between prerandomization stress echocardiography score and the effect of PCI on angina frequency score with a larger placebo-controlled effect in patients with the highest stress echocardiography score (Pinteraction=0.031). With our sample size, we were unable to detect an interaction between stress echocardiography score and any other patient-reported response variables: freedom from angina (Pinteraction=0.116), physical limitation (Pinteraction=0.461), quality of life (Pinteraction=0.689), EuroQOL 5 quality-of-life score (Pinteraction=0.789), or between stress echocardiography score and physician-assessed Canadian Cardiovascular Society angina class (Pinteraction=0.693), and treadmill exercise time (Pinteraction=0.426). CONCLUSIONS: The degree of ischemia assessed by dobutamine stress echocardiography predicts the placebo-controlled efficacy of PCI on patient-reported angina frequency. The greater the downstream stress echocardiography abnormality caused by a stenosis, the greater the reduction in symptoms from PCI. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT02062593.
Asunto(s)
Enfermedad de la Arteria Coronaria/tratamiento farmacológico , Dobutamina/farmacología , Ecocardiografía de Estrés/efectos de los fármacos , Isquemia/tratamiento farmacológico , Anciano , Angina Estable/diagnóstico , Angina Estable/tratamiento farmacológico , Enfermedad de la Arteria Coronaria/diagnóstico , Dobutamina/administración & dosificación , Tolerancia al Ejercicio/efectos de los fármacos , Femenino , Humanos , Isquemia/etiología , Isquemia/fisiopatología , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Calidad de VidaRESUMEN
BACKGROUND: Coronary revascularization guided by fractional flow reserve (FFR) is associated with better patient outcomes after the procedure than revascularization guided by angiography alone. It is unknown whether the instantaneous wave-free ratio (iFR), an alternative measure that does not require the administration of adenosine, will offer benefits similar to those of FFR. METHODS: We randomly assigned 2492 patients with coronary artery disease, in a 1:1 ratio, to undergo either iFR-guided or FFR-guided coronary revascularization. The primary end point was the 1-year risk of major adverse cardiac events, which were a composite of death from any cause, nonfatal myocardial infarction, or unplanned revascularization. The trial was designed to show the noninferiority of iFR to FFR, with a margin of 3.4 percentage points for the difference in risk. RESULTS: At 1 year, the primary end point had occurred in 78 of 1148 patients (6.8%) in the iFR group and in 83 of 1182 patients (7.0%) in the FFR group (difference in risk, -0.2 percentage points; 95% confidence interval [CI], -2.3 to 1.8; P<0.001 for noninferiority; hazard ratio, 0.95; 95% CI, 0.68 to 1.33; P=0.78). The risk of each component of the primary end point and of death from cardiovascular or noncardiovascular causes did not differ significantly between the groups. The number of patients who had adverse procedural symptoms and clinical signs was significantly lower in the iFR group than in the FFR group (39 patients [3.1%] vs. 385 patients [30.8%], P<0.001), and the median procedural time was significantly shorter (40.5 minutes vs. 45.0 minutes, P=0.001). CONCLUSIONS: Coronary revascularization guided by iFR was noninferior to revascularization guided by FFR with respect to the risk of major adverse cardiac events at 1 year. The rate of adverse procedural signs and symptoms was lower and the procedural time was shorter with iFR than with FFR. (Funded by Philips Volcano; DEFINE-FLAIR ClinicalTrials.gov number, NCT02053038 .).
Asunto(s)
Síndrome Coronario Agudo/fisiopatología , Estenosis Coronaria/fisiopatología , Estenosis Coronaria/terapia , Reserva del Flujo Fraccional Miocárdico , Intervención Coronaria Percutánea/métodos , Síndrome Coronario Agudo/diagnóstico por imagen , Anciano , Angina de Pecho/diagnóstico por imagen , Angina de Pecho/fisiopatología , Enfermedades Cardiovasculares/mortalidad , Angiografía Coronaria , Estenosis Coronaria/diagnóstico por imagen , Femenino , Estudios de Seguimiento , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Infarto del Miocardio/epidemiología , Retratamiento , Índice de Severidad de la EnfermedadRESUMEN
BACKGROUND: There are no data on how fractional flow reserve (FFR) and instantaneous wave-free ratio (iFR) are associated with the placebo-controlled efficacy of percutaneous coronary intervention (PCI) in stable single-vessel coronary artery disease. METHODS: We report the association between prerandomization invasive physiology within ORBITA (Objective Randomised Blinded Investigation With Optimal Medical Therapy of Angioplasty in Stable Angina), a placebo-controlled trial of patients who have stable angina with angiographically severe single-vessel coronary disease clinically eligible for PCI. Patients underwent prerandomization research FFR and iFR assessment. The operator was blinded to these values. Assessment of response variables, treadmill exercise time, stress echocardiography score, symptom frequency, and angina severity were performed at prerandomization and blinded follow-up. Effects were calculated by analysis of covariance. The ability of FFR and iFR to predict placebo-controlled changes in response variables was tested by using regression modeling. RESULTS: Invasive physiology data were available in 196 patients (103 PCI and 93 placebo). At prerandomization, the majority had Canadian Cardiovascular Society class II or III symptoms (150/196, 76.5%). Mean FFR and iFR were 0.69±0.16 and 0.76±0.22, respectively; 97% had ≥1 positive ischemia tests. The estimated effect of PCI on between-arm prerandomization-adjusted total exercise time was 20.7 s (95% confidence interval [CI], -4.0 to 45.5; P=0.100) with no interaction of FFR ( Pinteraction=0.318) or iFR ( Pinteraction=0.523). PCI improved stress echocardiography score more than placebo (1.07 segment units; 95% CI, 0.70-1.44; P<0.00001). The placebo-controlled effect of PCI on stress echocardiography score increased progressively with decreasing FFR ( Pinteraction<0.00001) and decreasing iFR ( Pinteraction<0.00001). PCI did not improve angina frequency score significantly more than placebo (odds ratio, 1.64; 95% CI, 0.96-2.80; P=0.072) with no detectable evidence of interaction with FFR ( Pinteraction=0.849) or iFR ( Pinteraction=0.783). However, PCI resulted in more patient-reported freedom from angina than placebo (49.5% versus 31.5%; odds ratio, 2.47; 95% CI, 1.30-4.72; P=0.006) but neither FFR ( Pinteraction=0.693) nor iFR ( Pinteraction=0.761) modified this effect. CONCLUSIONS: In patients with stable angina and severe single-vessel disease, the blinded effect of PCI was more clearly seen by stress echocardiography score and freedom from angina than change in treadmill exercise time. Moreover, the lower the FFR or iFR, the greater the magnitude of stress echocardiographic improvement caused by PCI. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov . Unique identifier: NCT02062593.
Asunto(s)
Angina Estable/terapia , Cateterismo Cardíaco , Enfermedad de la Arteria Coronaria/terapia , Estenosis Coronaria/terapia , Reserva del Flujo Fraccional Miocárdico , Intervención Coronaria Percutánea , Agonistas de Receptores Adrenérgicos beta 1/administración & dosificación , Anciano , Angina Estable/diagnóstico , Angina Estable/fisiopatología , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/fisiopatología , Estenosis Coronaria/diagnóstico , Estenosis Coronaria/fisiopatología , Dobutamina/administración & dosificación , Ecocardiografía de Estrés/métodos , Prueba de Esfuerzo , Tolerancia al Ejercicio , Femenino , Estado de Salud , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Valor Predictivo de las Pruebas , Supervivencia sin Progresión , Calidad de Vida , Recuperación de la Función , Índice de Severidad de la Enfermedad , Factores de Tiempo , Reino UnidoRESUMEN
BACKGROUND: Symptomatic relief is the primary goal of percutaneous coronary intervention (PCI) in stable angina and is commonly observed clinically. However, there is no evidence from blinded, placebo-controlled randomised trials to show its efficacy. METHODS: ORBITA is a blinded, multicentre randomised trial of PCI versus a placebo procedure for angina relief that was done at five study sites in the UK. We enrolled patients with severe (≥70%) single-vessel stenoses. After enrolment, patients received 6 weeks of medication optimisation. Patients then had pre-randomisation assessments with cardiopulmonary exercise testing, symptom questionnaires, and dobutamine stress echocardiography. Patients were randomised 1:1 to undergo PCI or a placebo procedure by use of an automated online randomisation tool. After 6 weeks of follow-up, the assessments done before randomisation were repeated at the final assessment. The primary endpoint was difference in exercise time increment between groups. All analyses were based on the intention-to-treat principle and the study population contained all participants who underwent randomisation. This study is registered with ClinicalTrials.gov, number NCT02062593. FINDINGS: ORBITA enrolled 230 patients with ischaemic symptoms. After the medication optimisation phase and between Jan 6, 2014, and Aug 11, 2017, 200 patients underwent randomisation, with 105 patients assigned PCI and 95 assigned the placebo procedure. Lesions had mean area stenosis of 84·4% (SD 10·2), fractional flow reserve of 0·69 (0·16), and instantaneous wave-free ratio of 0·76 (0·22). There was no significant difference in the primary endpoint of exercise time increment between groups (PCI minus placebo 16·6 s, 95% CI -8·9 to 42·0, p=0·200). There were no deaths. Serious adverse events included four pressure-wire related complications in the placebo group, which required PCI, and five major bleeding events, including two in the PCI group and three in the placebo group. INTERPRETATION: In patients with medically treated angina and severe coronary stenosis, PCI did not increase exercise time by more than the effect of a placebo procedure. The efficacy of invasive procedures can be assessed with a placebo control, as is standard for pharmacotherapy. FUNDING: NIHR Imperial Biomedical Research Centre, Foundation for Circulatory Health, Imperial College Healthcare Charity, Philips Volcano, NIHR Barts Biomedical Research Centre.
Asunto(s)
Angina Estable/cirugía , Estenosis Coronaria/cirugía , Intervención Coronaria Percutánea , Anciano , Angina Estable/complicaciones , Angina Estable/diagnóstico por imagen , Angiografía Coronaria , Estenosis Coronaria/complicaciones , Estenosis Coronaria/diagnóstico por imagen , Método Doble Ciego , Tolerancia al Ejercicio , Femenino , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento , Reino UnidoRESUMEN
Aims: Guidelines recommend the use of fractional flow reserve (FFR) to guide percutaneous coronary intervention. For this purpose, physiological lesion assessment without adenosine may have a similar diagnostic accuracy as FFR. We aimed to investigate the performances of FFR, resting instantaneous wave-free ratio (iFR), and resting Pd/Pa compared with [15O]H2O positron emission tomography (PET) perfusion imaging. Methods and results: [15O]H2O PET and intracoronary pressure measurements were evaluated in 320 coronary arteries (of which 136 coronary stenoses) in 129 stable patients. The primary analysis consisting of the area-under-the-receiver-operating-characteristic curve for impaired PET hyperaemic myocardial blood flow (MBF) <2.3 mLâ min-1â g-1 in coronary stenoses was 0.78 [95% confidence interval (CI): 0.70-0.85] for FFR, 0.74 (95% CI: 0.66-0.81) for iFR, and 0.75 (95% CI: 0.67-0.82) for Pd/Pa. No significant differences between area-under-the-receiver-operating-characteristic curve were observed for any two indices compared. In a secondary analysis, the diagnostic accuracy compared with impaired PET hyperaemic MBF in coronary stenoses was 72% (95% CI: 64-79%, κ: 0.44) for FFR ≤0.80, 72% (95% CI: 64-80%, κ: 0.44) for iFR ≤0.89, and 70% (95% CI: 62-78%, κ: 0.40) for Pd/Pa ≤0.92. Other secondary analyses included a comparison of physiological indices with PET hyperaemic MBF in all vessels and all of the aforementioned analyses using PET myocardial perfusion reserve as comparator. Statistical testing for the secondary analyses showed results that were consistent with the results of the primary analysis. Conclusion: Fractional flow reserve, iFR, and Pd/Pa showed a similar performance when compared with PET imaging. Our results support the validity of invasive physiological lesion assessment under resting conditions by iFR or Pd/Pa. Trial registration: Sub-study of the PACIFIC trial with clinicaltrials.gov identifier: NCT01521468.
Asunto(s)
Presión Arterial/fisiología , Estenosis Coronaria/fisiopatología , Vasos Coronarios/fisiopatología , Reserva del Flujo Fraccional Miocárdico/fisiología , Tomografía de Emisión de Positrones/métodos , Cateterismo Cardíaco , Angiografía Coronaria , Estenosis Coronaria/diagnóstico , Vasos Coronarios/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Curva ROC , Reproducibilidad de los Resultados , Índice de Severidad de la EnfermedadRESUMEN
Aims: The efficacy of patent foramen ovale (PFO) closure for cryptogenic stroke has been controversial. We undertook a meta-analysis of randomized controlled trials (RCTs) comparing device closure with medical therapy to prevent recurrent stroke for patients with PFO. Methods and results: We systematically identified all RCTs comparing device closure to medical therapy for cryptogenic stroke in patients with PFO. The primary efficacy endpoint was recurrent stroke, analysed on an intention-to-treat basis. The primary safety endpoint was new onset atrial fibrillation (AF). Five studies (3440 patients) were included. In all, 1829 patients were randomized to device closure and 1611 to medical therapy. Across all patients, PFO closure was superior to medical therapy for prevention of stroke [hazard ratio (HR) 0.32, 95% confidence interval (95% CI) 0.13-0.82; P = 0.018, I2 = 73.4%]. The risk of AF was significantly increased with device closure [risk ratio (RR) 4.68, 95% CI 2.19-10.00, P<0.001, heterogeneity I2 = 27.5%)]. In patients with large shunts, PFO closure was associated with a significant reduction in stroke (HR 0.33, 95% CI 0.16-0.72; P = 0.005), whilst there was no significant reduction in stroke in patients with a small shunt (HR 0.90, 95% CI 0.50-1.60; P = 0.712). There was no effect from the presence or absence of an atrial septal aneurysm on outcomes (P = 0.994). Conclusion: In selected patients with cryptogenic stroke, PFO closure is superior to medical therapy for the prevention of further stroke: this is particularly true for patients with moderate-to-large shunts. Guidelines should be updated to reflect this.
Asunto(s)
Foramen Oval Permeable/tratamiento farmacológico , Foramen Oval Permeable/cirugía , Dispositivo Oclusor Septal , Accidente Cerebrovascular/prevención & control , Foramen Oval Permeable/complicaciones , Humanos , Ensayos Clínicos Controlados Aleatorios como Asunto , Recurrencia , Accidente Cerebrovascular/etiología , Resultado del TratamientoRESUMEN
BACKGROUND: Our understanding of human coronary physiological behaviour is derived from animal models. We sought to describe physiological behaviour across a large collection of invasive pressure and flow velocity measurements, to provide a better understanding of the relationships between these physiological parameters and to evaluate the rationale for resting stenosis assessment. METHODS AND RESULTS: Five hundred and sixty-seven simultaneous intracoronary pressure and flow velocity assessments from 301 patients were analysed for coronary flow velocity, trans-stenotic pressure gradient (TG), and microvascular resistance (MVR). Measurements were made during baseline and hyperaemic conditions. The whole cardiac cycle and the diastolic wave-free period were assessed. Stenoses were assessed according to fractional flow reserve (FFR) and quantitative coronary angiography DS%. With progressive worsening of stenoses, from unobstructed angiographic normal vessels to those with FFR ≤ 0.50, hyperaemic flow falls significantly from 45 to 19 cm/s, Ptrend < 0.001 in a curvilinear pattern. Resting flow was unaffected by stenosis severity and was consistent across all strata of stenosis (Ptrend > 0.05 for all). Trans-stenotic pressure gradient rose with stenosis severity for both rest and hyperaemic measures (Ptrend < 0.001 for both). Microvascular resistance declines with stenosis severity under resting conditions (Ptrend < 0.001), but was unchanged at hyperaemia (2.3 ± 1.1 mmHg/cm/s; Ptrend = 0.19). CONCLUSIONS: With progressive stenosis severity, TG rises. However, while hyperaemic flow falls significantly, resting coronary flow is maintained by compensatory reduction of MVR, demonstrating coronary auto-regulation. These data support the translation of coronary physiological concepts derived from animals to patients with coronary artery disease and furthermore, suggest that resting pressure indices can be used to detect the haemodynamic significance of coronary artery stenoses.
Asunto(s)
Constricción Patológica , Velocidad del Flujo Sanguíneo , Angiografía Coronaria , Circulación Coronaria , Estenosis Coronaria , Vasos Coronarios , Reserva del Flujo Fraccional Miocárdico , HumanosRESUMEN
Wave intensity analysis (WIA) has found particular applicability in the coronary circulation where it can quantify traveling waves that accelerate and decelerate blood flow. The most important wave for the regulation of flow is the backward-traveling decompression wave (BDW). Coronary WIA has hitherto always been calculated from invasive measures of pressure and flow. However, recently it has become feasible to obtain estimates of these waveforms noninvasively. In this study we set out to assess the agreement between invasive and noninvasive coronary WIA at rest and measure the effect of exercise. Twenty-two patients (mean age 60) with unobstructed coronaries underwent invasive WIA in the left anterior descending artery (LAD). Immediately afterwards, noninvasive LAD flow and pressure were recorded and WIA calculated from pulsed-wave Doppler coronary flow velocity and central blood pressure waveforms measured using a cuff-based technique. Nine of these patients underwent noninvasive coronary WIA assessment during exercise. A pattern of six waves were observed in both modalities. The BDW was similar between invasive and noninvasive measures [peak: 14.9 ± 7.8 vs. -13.8 ± 7.1 × 10(4) W·m(-2)·s(-2), concordance correlation coefficient (CCC): 0.73, P < 0.01; cumulative: -64.4 ± 32.8 vs. -59.4 ± 34.2 × 10(2) W·m(-2)·s(-1), CCC: 0.66, P < 0.01], but smaller waves were underestimated noninvasively. Increased left ventricular mass correlated with a decreased noninvasive BDW fraction (r = -0.48, P = 0.02). Exercise increased the BDW: at maximum exercise peak BDW was -47.0 ± 29.5 × 10(4) W·m(-2)·s(-2) (P < 0.01 vs. rest) and cumulative BDW -19.2 ± 12.6 × 10(3) W·m(-2)·s(-1) (P < 0.01 vs. rest). The BDW can be measured noninvasively with acceptable reliably potentially simplifying assessments and increasing the applicability of coronary WIA.
Asunto(s)
Determinación de la Presión Sanguínea , Circulación Coronaria , Vasos Coronarios/fisiología , Ecocardiografía Doppler en Color , Ecocardiografía Doppler de Pulso , Ejercicio Físico/fisiología , Anciano , Presión Arterial , Velocidad del Flujo Sanguíneo , Determinación de la Presión Sanguínea/instrumentación , Arteria Braquial/fisiología , Cateterismo Cardíaco , Vasos Coronarios/diagnóstico por imagen , Prueba de Esfuerzo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Esfigmomanometros , Factores de TiempoRESUMEN
Pressure-wire technology, most typically fractional flow reserve (FFR), has provided interventional cardiologists with a means of determining the physiological importance of a stenosis during angiography. There has been renewed interest in coronary physiology in the light of guideline recognition, ongoing clinical research and new technologies changing the paradigm of how assessment is performed in the catheter laboratory. We reflect on FFR, with regards the potential effects of changing hemodynamics on FFR and the latest evidence with regards to outcomes. We also review the instantaneous wave-free ratio (iFR), a new pressure-only index, measured at rest, that is under active evaluation in several international randomized controlled trials. We review the accumulated evidence and discuss the important physiological concepts between pressure and flow that underlie the approach to using resting indices. Finally we investigate future developments, including physiological mapping with iFR-Pullback and the potential to predict the hemodynamic effect of stenting.
Asunto(s)
Reserva del Flujo Fraccional Miocárdico , Isquemia Miocárdica/fisiopatología , Adenosina/farmacología , Cateterismo Cardíaco/métodos , Angiografía Coronaria/métodos , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/fisiopatología , Estenosis Coronaria/cirugía , Vasos Coronarios/fisiopatología , Reserva del Flujo Fraccional Miocárdico/fisiología , Hemodinámica/efectos de los fármacos , Humanos , Hiperemia/inducido químicamente , Hiperemia/fisiopatología , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/cirugía , Revascularización Miocárdica/métodos , Stents , Vasodilatadores/farmacologíaRESUMEN
BACKGROUND: In chronic ischemic heart disease, focal stenosis, diffuse atherosclerotic narrowings, and microcirculatory dysfunction (MCD) contribute to limit myocardial flow. The prevalence of these ischemic heart disease levels in fractional flow reserve (FFR) interrogated vessels remains largely unknown. METHODS AND RESULTS: Using intracoronary measurements, 91 coronaries (78 patients) with intermediate stenoses were classified in 4 FFR and coronary flow reserve (CFR) agreement groups, using FFR>0.80 and CFR<2 as cutoffs. Index of microcirculatory resistance (IMR) and atherosclerotic burden (Gensini score) were also assessed. MCD was assumed when IMR≥29.1 (75(th) percentile). Fifty-four (59.3%) vessels had normal FFR, from which only 20 (37%) presented both normal CFR and IMR. Among vessels with FFR>0.80, most (63%) presented disturbed hemodynamics: abnormal CFR in 28 (52%) and MCD in 18 (33%). Vessels with FFR>0.80 presented higher IMR [adjusted mean 27.6 (95% confidence interval, 23.4-31.8)] than those with FFR≤0.80 [17.3 (95% confidence interval, 13.0-21.7), p=0.001]. Atherosclerotic burden was inversely correlated with CFR (r=-0.207, P=0.055), and in vessels with FFR>0.80 and CFR<2 (n=28, 39%), IMR had a wide dispersion (7-72.7 U), suggesting a combination of diffuse atherosclerotic narrowings and MCD. Vessels with FFR≤0.80 and normal CFR presented the lowest IMR, suggesting a preserved microcirculation. CONCLUSIONS: A substantial number of coronary arteries with stenoses showing an FFR>0.80 present disturbed hemodynamics. Integration of FFR, CFR, and IMR supports the existence of differentiated patterns of ischemic heart disease that combine focal and diffuse coronary narrowings with variable degrees of MCD.
Asunto(s)
Estenosis Coronaria/fisiopatología , Vasos Coronarios/fisiopatología , Reserva del Flujo Fraccional Miocárdico/fisiología , Hemodinámica/fisiología , Microcirculación/fisiología , Isquemia Miocárdica/fisiopatología , Pericardio/fisiopatología , Anciano , Velocidad del Flujo Sanguíneo/fisiología , Constricción Patológica/fisiopatología , Enfermedad de la Arteria Coronaria/epidemiología , Enfermedad de la Arteria Coronaria/fisiopatología , Circulación Coronaria/fisiología , Estenosis Coronaria/clasificación , Femenino , Humanos , Masculino , Persona de Mediana Edad , Isquemia Miocárdica/clasificación , Prevalencia , Estudios ProspectivosRESUMEN
OBJECTIVES: To evaluate the first experience of real-time instantaneous wave-free ratio (iFR) measurement by clinicians. BACKGROUND: The iFR is a new vasodilator-free index of coronary stenosis severity, calculated as a trans-lesion pressure ratio during a specific period of baseline diastole, when distal resistance is lowest and stable. Because all previous studies have calculated iFR offline, the feasibility of real-time iFR measurement has never been assessed. METHODS: Three hundred ninety-two stenoses with angiographically intermediate stenoses were included in this multicenter international analysis. Instantaneous wave-free ratio and fractional flow reserve (FFR) were performed in real time on commercially available consoles. The classification agreement of coronary stenoses between iFR and FFR was calculated. RESULTS: Instantaneous wave-free ratio and FFR maintain a close level of diagnostic agreement when both are measured by clinicians in real time (for a clinical 0.80 FFR cutoff: area under the receiver operating characteristic curve [ROC(AUC)] 0.87, classification match 80%, and optimal iFR cutoff 0.90; for a ischemic 0.75 FFR cutoff: iFR ROC(AUC) 0.90, classification match 88%, and optimal iFR cutoff 0.85; if the FFR 0.75-0.80 gray zone is accounted for: ROC(AUC) 0.93, classification match 92%). When iFR and FFR are evaluated together in a hybrid decision-making strategy, 61% of the population is spared from vasodilator while maintaining a 94% overall agreement with FFR lesion classification. CONCLUSION: When measured in real time, iFR maintains the close relationship to FFR reported in offline studies. These findings confirm the feasibility and reliability of real-time iFR calculation by clinicians.