Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Eur Heart J ; 2024 May 31.
Artículo en Inglés | MEDLINE | ID: mdl-38820201

RESUMEN

BACKGROUND AND AIMS: Surgical explantation of transcatheter heart valves (THVs) is rapidly increasing, but there are limited data on patients with THV-associated infective endocarditis (IE). This study aims to assess the outcomes of patients undergoing THV explant for IE. METHODS: All patients who underwent THV explant between 2011 and 2022 from 44 sites in the EXPLANT-TAVR registry were identified. Patients with IE as the reason for THV explant were compared to those with other mechanisms of bioprosthetic valve dysfunction (BVD). RESULTS: A total of 372 patients from the EXPLANT-TAVR registry were included. Among them, 184 (49.5%) patients underwent THV explant due to IE and 188 (50.5%) patients due to BVD. At the index transcatheter aortic valve replacement, patients undergoing THV explant for IE were older (74.3 ± 8.6 vs. 71 ± 10.6 years) and had a lower Society of Thoracic Surgeons risk score [2.6% (1.8-5.0) vs. 3.3% (2.1-5.6), P = .029] compared to patients with BVD. Compared to BVD, IE patients had longer intensive care unit and hospital stays (P < .05) and higher stroke rates at 30 days (8.6% vs. 2.9%, P = .032) and 1 year (16.2% vs. 5.2%, P = .010). Adjusted in-hospital, 30-day, and 1-year mortality was 12.1%, 16.1%, and 33.8%, respectively, for the entire cohort, with no significant differences between groups. Although mortality was numerically higher in IE patients 3 years postsurgery (29.6% for BVD vs. 43.9% for IE), Kaplan-Meier analysis showed no significant differences between groups (P = .16). CONCLUSIONS: In the EXPLANT-TAVR registry, patients undergoing THV explant for IE had higher 30-day and 1-year stroke rates and longer intensive care unit and hospital stays. Moreover, patients undergoing THV explant for IE had a higher 3-year mortality rate, which did not reach statistical significance given the relatively small sample size of this unique cohort and the reduced number of events.

2.
N Engl J Med ; 380(18): 1706-1715, 2019 05 02.
Artículo en Inglés | MEDLINE | ID: mdl-30883053

RESUMEN

BACKGROUND: Transcatheter aortic-valve replacement (TAVR) is an alternative to surgery in patients with severe aortic stenosis who are at increased risk for death from surgery; less is known about TAVR in low-risk patients. METHODS: We performed a randomized noninferiority trial in which TAVR with a self-expanding supraannular bioprosthesis was compared with surgical aortic-valve replacement in patients who had severe aortic stenosis and were at low surgical risk. When 850 patients had reached 12-month follow-up, we analyzed data regarding the primary end point, a composite of death or disabling stroke at 24 months, using Bayesian methods. RESULTS: Of the 1468 patients who underwent randomization, an attempted TAVR or surgical procedure was performed in 1403. The patients' mean age was 74 years. The 24-month estimated incidence of the primary end point was 5.3% in the TAVR group and 6.7% in the surgery group (difference, -1.4 percentage points; 95% Bayesian credible interval for difference, -4.9 to 2.1; posterior probability of noninferiority >0.999). At 30 days, patients who had undergone TAVR, as compared with surgery, had a lower incidence of disabling stroke (0.5% vs. 1.7%), bleeding complications (2.4% vs. 7.5%), acute kidney injury (0.9% vs. 2.8%), and atrial fibrillation (7.7% vs. 35.4%) and a higher incidence of moderate or severe aortic regurgitation (3.5% vs. 0.5%) and pacemaker implantation (17.4% vs. 6.1%). At 12 months, patients in the TAVR group had lower aortic-valve gradients than those in the surgery group (8.6 mm Hg vs. 11.2 mm Hg) and larger effective orifice areas (2.3 cm2 vs. 2.0 cm2). CONCLUSIONS: In patients with severe aortic stenosis who were at low surgical risk, TAVR with a self-expanding supraannular bioprosthesis was noninferior to surgery with respect to the composite end point of death or disabling stroke at 24 months. (Funded by Medtronic; ClinicalTrials.gov number, NCT02701283.).


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas/métodos , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Accidente Cerebrovascular/etiología , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Insuficiencia de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/mortalidad , Fibrilación Atrial/etiología , Teorema de Bayes , Ecocardiografía , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Estimación de Kaplan-Meier , Tiempo de Internación , Masculino , Complicaciones Posoperatorias/epidemiología , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
3.
Catheter Cardiovasc Interv ; 98(3): 483-491, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-32915510

RESUMEN

OBJECTIVES: We sought to evaluate the severity and patterns of calcifications in the left main coronary artery (LMCA) and proximal segments of left anterior descending coronary artery (LAD) and left circumflex artery (LCX) using optical coherence tomography (OCT) in patients with and without prior coronary artery bypass grafting (CABG). BACKGROUND: CABG may accelerate upstream calcium development. METHODS: OCT images (n = 76) of the LMCA bifurcation from either the LAD or LCX in 76 patients with at least one patent left coronary graft, on average 7.0 ± 5.6 years post-CABG, were compared with 148 OCT images in propensity-score-matched non-CABG controls. RESULTS: Minimum lumen areas in the LMCA, LAD, and LCX in post-CABG patients were smaller than non-CABG controls. Maximum calcium arc and thickness as well as calcium length were greater in the LMCA and LCX, but not in the LAD in post-CABG patients versus non-CABG controls. Calcium located at the carina of a bifurcation, calcified nodules (CN), thin intimal calcium, and lobulated calcium were more prevalent in post-CABG patients. After adjusting for multiple covariates, prior CABG was an independent predictor of calcification at the carina of a bifurcation (odds ratio [OR] 5.77 [95% confidence interval, CI: 1.5-21.6]), thin intimal calcium (4.7 [1.5-14.4]), and the presence of a CN (15.60 [3.2-76.2]). CONCLUSIONS: Prior CABG is associated with greater amount of calcium in the LMCA and the proximal LCX, as well as higher prevalence of atypical calcium patterns, including CN, thin or lobulated calcium, and calcifications located at the carina of a bifurcation, compared with non-CABG controls.


Asunto(s)
Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Angiografía Coronaria , Puente de Arteria Coronaria/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/cirugía , Humanos , Tomografía de Coherencia Óptica , Resultado del Tratamiento
4.
Catheter Cardiovasc Interv ; 98(4): E637-E646, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34004077

RESUMEN

OBJECTIVES: We report the 30-day outcomes from the roll-in cohort of the CLASP IID trial, representing the first procedures performed by each site. BACKGROUND: The currently enrolling CLASP IID/IIF pivotal trial is a multicenter, prospective, randomized trial assessing the safety and effectiveness of the PASCAL transcatheter valve repair system in patients with clinically significant MR. The trial allows for up to three roll-in patients per site. METHODS: Eligibility criteria were: DMR ≥3+, prohibitive surgical risk, and deemed suitable for transcatheter repair by the local heart team. Trial oversight included a central screening committee and echocardiographic core laboratory. The primary safety endpoint was a 30-day composite MAE: cardiovascular mortality, stroke, myocardial infarction (MI), new need for renal replacement therapy, severe bleeding, and non-elective mitral valve re-intervention, adjudicated by an independent clinical events committee. Thirty-day echocardiographic, functional, and quality of life outcomes were assessed. RESULTS: A total of 45 roll-in patients with mean age of 83 years and 69% in NYHA class III/IV were treated. Successful implantation was achieved in 100%. The 30-day composite MAE rate was 8.9% including one cardiovascular death (2.2%) due to severe bleeding from a hemorrhagic stroke, one MI, and no need for re-intervention. MR≤1+ was achieved in 73% and ≤2+ in 98% of patients. 89% of patients were in NYHA class I/II (p < .001) with improvements in 6MWD (30 m; p = .054) and KCCQ (17 points; p < .001). CONCLUSIONS: Early results representing sites with first experience with the PASCAL repair system showed favorable 30-day outcomes in patients with DMR≥3+ at prohibitive surgical risk.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Anciano de 80 o más Años , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Estudios Prospectivos , Calidad de Vida , Resultado del Tratamiento
5.
Cardiology ; 146(4): 489-500, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33752215

RESUMEN

INTRODUCTION: The changes and the prognostic implications of left atrial (LA) volumes (LAV), LA function, and vascular load in patients undergoing transcatheter aortic valve implantation (TAVI) for severe aortic stenosis (AS) are less known. METHODS: We enrolled 150 symptomatic patients (mean age 82 ± 8 years, 58% female, and pre-TAVI aortic valve area 0.40 ± 0.19 cm/m2) with severe AS who underwent 2D transthoracic echocardiography and 2D speckle tracking echocardiography at average 21 ± 35 days before and 171 ± 217 days after TAVI. The end point was a composite of new onset of atrial fibrillation, hospitalization for heart failure and all-cause death (major adverse cardiac events [MACE]). RESULTS: After TAVI, indexed maximal LA volume and minimum volume of the LA decreased by 2.1 ± 10 mL/m2 and 1.6 ± 7 mL/m2 (p = 0.032 and p = 0.011, respectively), LA function index increased by 6.8 ± 11 units (p < 0.001), and LA stiffness decreased by 0.38 ± 2.0 (p = 0.05). No other changes in the LA phasic volumes, emptying fractions, and vascular load were noted. Post-TAVI, both left atrial and ventricular global peak longitudinal strain improved by about 6% (p = 0.01 and 0.02, respectively). MACE was reached by 37 (25%) patients after a median follow-up period of 172 days (interquartile range, 20-727). In multivariable models, MACE was associated with both pre- and post-TAVI LA global peak longitudinal strain (hazard ratio [HR] 0.75, CI 0.59-0.97; and HR 0.77, CI 0.60-1.00, per 5 percentage point units, respectively), pre-TAVI LV global endocardial longitudinal strain (HR 1.37, CI 1.02-1.83 per 5 percentage point units), and with most of the LA phasic volumes. CONCLUSION: Within 6 months after TAVI, there is reverse LA remodeling and an improvement in LA reservoir function. Pre- and post-TAVI indices of LA function and volume remain independently associated with MACE. Larger studies enrolling a greater diversity of patients may provide sufficient evidence for the utilization of these imaging biomarkers in clinical practice.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Función del Atrio Izquierdo , Femenino , Atrios Cardíacos/diagnóstico por imagen , Humanos , Masculino , Pronóstico , Resultado del Tratamiento , Función Ventricular Izquierda
6.
N Engl J Med ; 370(19): 1790-8, 2014 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-24678937

RESUMEN

BACKGROUND: We compared transcatheter aortic-valve replacement (TAVR), using a self-expanding transcatheter aortic-valve bioprosthesis, with surgical aortic-valve replacement in patients with severe aortic stenosis and an increased risk of death during surgery. METHODS: We recruited patients with severe aortic stenosis who were at increased surgical risk as determined by the heart team at each study center. Risk assessment included the Society of Thoracic Surgeons Predictor Risk of Mortality estimate and consideration of other key risk factors. Eligible patients were randomly assigned in a 1:1 ratio to TAVR with the self-expanding transcatheter valve (TAVR group) or to surgical aortic-valve replacement (surgical group). The primary end point was the rate of death from any cause at 1 year, evaluated with the use of both noninferiority and superiority testing. RESULTS: A total of 795 patients underwent randomization at 45 centers in the United States. In the as-treated analysis, the rate of death from any cause at 1 year was significantly lower in the TAVR group than in the surgical group (14.2% vs. 19.1%), with an absolute reduction in risk of 4.9 percentage points (upper boundary of the 95% confidence interval, -0.4; P<0.001 for noninferiority; P = 0.04 for superiority). The results were similar in the intention-to-treat analysis. In a hierarchical testing procedure, TAVR was noninferior with respect to echocardiographic indexes of valve stenosis, functional status, and quality of life. Exploratory analyses suggested a reduction in the rate of major adverse cardiovascular and cerebrovascular events and no increase in the risk of stroke. CONCLUSIONS: In patients with severe aortic stenosis who are at increased surgical risk, TAVR with a self-expanding transcatheter aortic-valve bioprosthesis was associated with a significantly higher rate of survival at 1 year than surgical aortic-valve replacement. (Funded by Medtronic; U.S. CoreValve High Risk Study ClinicalTrials.gov number, NCT01240902.).


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Bioprótesis , Cateterismo Cardíaco , Prótesis Valvulares Cardíacas , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/terapia , Cateterismo Cardíaco/efectos adversos , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Complicaciones Posoperatorias , Diseño de Prótesis , Factores de Riesgo , Tasa de Supervivencia
7.
Am J Cardiol ; 218: 102-112, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38432332

RESUMEN

There are various devices under clinical investigation for transcatheter mitral valve intervention and transcatheter tricuspid valve intervention (TTVI); however, the exclusion rates remain high. We aimed to investigate the exclusion rates for transcatheter mitral valve repair (TMVr), transcatheter mitral valve replacement (TMVR), transcatheter tricuspid valve repair (TTVr), and transcatheter tricuspid valve replacement (TTVR). There were 129 patients who were referred to St. Francis Hospital & Heart Center valve clinic and completed screening between January 2021 and July 2022. The causes for exclusion were classified into 4 categories: patient withdrawal, anatomic unsuitability, clinical criteria, and medical futility. In 129 patients, the exclusion rates for TMVr, TMVR, TTVr, and TTVR were 81%, 85%, 91%, and 87%, respectively. Patient withdrawal and medical futility were leading etiologies for exclusion, followed by anatomic unsuitability. TMVr had the highest rate of patient withdrawal (64%) and the lowest anatomic unsuitability (5%) because of short posterior leaflet length. Replacement interventions have a higher anatomic unsuitability (33%) than repair interventions (17%) (p = 0.04). Most exclusions of anatomic unsuitability were because of mitral stenosis or small annulus size for TMVR and large annulus size for TTVR. A total of 50% of exclusions from TTVr were because of the presence of pacemaker/defibrillator leads. In patients excluded from their respective trials, patients being referred for TMVr had the highest recurrent hospitalization and repair group had a higher mortality (p <0.01 and p = 0.01, respectively). In conclusion, the exclusion rates for transcatheter mitral valve intervention and TTVI trials remain high because of various reasons, limiting patient enrollment and treatment. This supports the need for further device improvement or exploring alternative means of therapy.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Válvula Tricúspide/cirugía , Cateterismo Cardíaco , Resultado del Tratamiento , Insuficiencia de la Válvula Mitral/cirugía , Hospitales
8.
Artículo en Inglés | MEDLINE | ID: mdl-38599918

RESUMEN

BACKGROUND: The next generation supra-annular, self-expanding Evolut FX transcatheter aortic valve (TAV) system was designed to improve catheter deliverability, provide stable and symmetric valve deployment, and assess commissural alignment during the procedure. The impact of these modifications has not been clinically evaluated. METHODS: Procedural information was collected by survey in 2 Stages: Stage I comprised 23 centers with extensive experience with Evolut TAV systems, and Stage II comprised an additional 46 centers with a broad range of balloon- and self-expanding system experience. Operators were to compare the experience with the Evolut FX to the predicate Evolut PRO+ system. RESULTS: There were 285 cases during Stage I from June 24 to August 12, 2022, and 254 cases during Stage II from August 15 to September 11, 2022. Overall, the cusp overlap technique was used in 88.6 %, and commissural alignment was achieved in 96.1 % of these cases. Compared to implanter's previous experience with the Evolut PRO+ system, less resistance was noted with the Evolut FX system: in 83.0 % of cases during vascular insertion, in 84.7 % of cases while tracking through the vasculature, in 84.4 % of cases while traversing over the arch, and 76.1 % of cases in advancing across the valve. Better symmetry of valve depth was observed in 423 of 525 cases (80.6 %). CONCLUSION: Evolut FX system design modifications translated into improvements in catheter deliverability, deployment symmetry and stability, and commissural alignment as assessed by experienced self-expanding and balloon expandable operators.

9.
J Cardiovasc Magn Reson ; 15: 99, 2013 Oct 29.
Artículo en Inglés | MEDLINE | ID: mdl-24168103

RESUMEN

BACKGROUND: Left atrial volume (LAV) and emptying fraction (LAEF) are phasic during cardiac cycle. Their relationships to left ventricular end diastolic pressure (LVEDP) have not been fully defined. METHODS: Forty one patients undergoing clinically indicated left heart catheterization were recruited for same day cardiovascular magnetic resonance (CMR). LAV and LAEF were assessed in cine images using biplane area and length method. Three phasic LAV was assessed at LV end systole (LAV(max)), LV end diastole (LAV(min)) and late LV diastole prior to LA contraction (LAV(ac)). LAEF was assessed as global LAEF (LAEF(Total)), passive (LAEF(Passive)) and active LAEF (LAEF(Contractile)). The relationships of phasic LAV and LAEF to LVEDP were assessed using Receiver operating characteristic comparing areas under the curves (AUC). RESULTS: The mean age of the patients was 59 years. A history of heart failure was present in 16 (39%) with NYHA functional class III or IV in 8 (20%) patients. Average LV ejection fraction was 49 ± 16% ranging from 10% to 74% and LVEDP by catheterization 14 ± 8 mmHg ranging from 4 mmHg to 32 mmHg. LAV(min) had the strongest association with LVEDP elevation (>12 mmHg) (AUC 0.765, p = 0.002), as compared to LAV(max) (AUC 0.677, p = 0.074) and LAV(ac) (AUC 0.735, p = 0.008). Among three phasic LAEF assessed, LAEF(Total) had the closest association with LVEDP elevation (AUC 0.780, p = 0.001), followed by LAEF(Contractile) (AUC 0.698, p = 0.022) and LAEF(Passive) (AUC 0.656, p = 0.077). CONCLUSIONS: Increased LAV(min) and decreased LAEF(Total) have the best performance in identifying elevated LVEDP among three phasic LAV and LAEF analyzed. Future studies should further characterize LA phasic indices in clinical outcomes.


Asunto(s)
Función del Atrio Izquierdo , Cardiopatías/diagnóstico , Imagen por Resonancia Cinemagnética , Función Ventricular Izquierda , Presión Ventricular , Adulto , Anciano , Área Bajo la Curva , Cateterismo Cardíaco , Femenino , Cardiopatías/fisiopatología , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Curva ROC , Volumen Sistólico , Factores de Tiempo
10.
JAMA Cardiol ; 8(2): 111-119, 2023 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-36515976

RESUMEN

Importance: The frequency and clinical importance of structural valve deterioration (SVD) in patients undergoing self-expanding transcatheter aortic valve implantation (TAVI) or surgery is poorly understood. Objective: To evaluate the 5-year incidence, clinical outcomes, and predictors of hemodynamic SVD in patients undergoing self-expanding TAVI or surgery. Design, Setting, and Participants: This post hoc analysis pooled data from the CoreValve US High Risk Pivotal (n = 615) and SURTAVI (n = 1484) randomized clinical trials (RCTs); it was supplemented by the CoreValve Extreme Risk Pivotal trial (n = 485) and CoreValve Continued Access Study (n = 2178). Patients with severe aortic valve stenosis deemed to be at intermediate or increased risk of 30-day surgical mortality were included. Data were collected from December 2010 to June 2016, and data were analyzed from December 2021 to October 2022. Interventions: Patients were randomized to self-expanding TAVI or surgery in the RCTs or underwent self-expanding TAVI for clinical indications in the nonrandomized studies. Main Outcomes and Measures: The primary end point was the incidence of SVD through 5 years (from the RCTs). Factors associated with SVD and its association with clinical outcomes were evaluated for the pooled RCT and non-RCT population. SVD was defined as (1) an increase in mean gradient of 10 mm Hg or greater from discharge or at 30 days to last echocardiography with a final mean gradient of 20 mm Hg or greater or (2) new-onset moderate or severe intraprosthetic aortic regurgitation or an increase of 1 grade or more. Results: Of 4762 included patients, 2605 (54.7%) were male, and the mean (SD) age was 82.1 (7.4) years. A total of 2099 RCT patients, including 1128 who received TAVI and 971 who received surgery, and 2663 non-RCT patients who received TAVI were included. The cumulative incidence of SVD treating death as a competing risk was lower in patients undergoing TAVI than surgery (TAVI, 2.20%; surgery, 4.38%; hazard ratio [HR], 0.46; 95% CI, 0.27-0.78; P = .004). This lower risk was most pronounced in patients with smaller annuli (23 mm diameter or smaller; TAVI, 1.32%; surgery, 5.84%; HR, 0.21; 95% CI, 0.06-0.73; P = .02). SVD was associated with increased 5-year all-cause mortality (HR, 2.03; 95% CI, 1.46-2.82; P < .001), cardiovascular mortality (HR, 1.86; 95% CI, 1.20-2.90; P = .006), and valve disease or worsening heart failure hospitalizations (HR, 2.17; 95% CI, 1.23-3.84; P = .008). Predictors of SVD were developed from multivariate analysis. Conclusions and Relevance: This study found a lower rate of SVD in patients undergoing self-expanding TAVI vs surgery at 5 years. Doppler echocardiography was a valuable tool to detect SVD, which was associated with worse clinical outcomes. Trial Registration: ClinicalTrials.gov Identifiers: NCT01240902, NCT01586910, and NCT01531374.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Masculino , Humanos , Anciano de 80 o más Años , Femenino , Válvula Aórtica/cirugía , Resultado del Tratamiento , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
11.
JACC Cardiovasc Interv ; 16(8): 927-941, 2023 04 24.
Artículo en Inglés | MEDLINE | ID: mdl-37100556

RESUMEN

BACKGROUND: Valve reintervention after transcatheter aortic valve replacement (TAVR) failure has not been studied in detail. OBJECTIVES: The authors sought to determine outcomes of TAVR surgical explantation (TAVR-explant) vs redo-TAVR because they are largely unknown. METHODS: From May 2009 to February 2022, 396 patients in the international EXPLANTORREDO-TAVR registry underwent TAVR-explant (181, 46.4%) or redo-TAVR (215, 54.3%) for transcatheter heart valve (THV) failure during a separate admission from the initial TAVR. Outcomes were reported at 30 days and 1 year. RESULTS: The incidence of reintervention after THV failure was 0.59% with increasing volume during the study period. Median time from index-TAVR to reintervention was shorter in TAVR-explant vs redo-TAVR (17.6 months [IQR: 5.0-40.7 months] vs 45.7 months [IQR: 10.6-75.6 months]; P < 0.001], respectively. TAVR-explant had more prosthesis-patient mismatch (17.1% vs 0.5%; P < 0.001) as the indication for reintervention, whereas redo-TAVR had more structural valve degeneration (63.7% vs 51.9%; P = 0.023), with a similar incidence of ≥moderate paravalvular leak between groups (28.7% vs 32.8% in redo-TAVR; P = 0.44). There was a similar proportion of balloon-expandable THV failures (39.8% TAVR-explant vs 40.5% redo-TAVR; P = 0.92). Median follow-up was 11.3 (IQR: 1.6-27.1 months) after reintervention. Compared with redo-TAVR, TAVR-explant had higher mortality at 30 days (13.6% vs 3.4%; P < 0.001) and 1 year (32.4% vs 15.4%; P = 0.001), with similar stroke rates between groups. On landmark analysis, mortality was similar between groups after 30 days (P = 0.91). CONCLUSIONS: In this first report of the EXPLANTORREDO-TAVR global registry, TAVR-explant had a shorter median time to reintervention, with less structural valve degeneration, more prosthesis-patient mismatch, and similar paravalvular leak rates compared with redo-TAVR. TAVR-explant had higher mortality at 30 days and 1 year, but similar rates on landmark analysis after 30 days.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Factores de Riesgo , Sistema de Registros , Diseño de Prótesis
12.
Cardiovasc Revasc Med ; 37: 135-144, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34187754

RESUMEN

Intravascular lithotripsy (IVL) is a new technique for treatment of severely calcified lesions that uses acoustic shockwaves in a balloon-based system to induce fracture in calcific plaque, facilitating luminal gain and vessel expansion. In this review, we provide a concise summary of the available data and clinical experience of IVL in various peripheral vascular beds, including facilitating vascular access for large-bore devices. We discuss the physics and mode of action of IVL in modifying calcified plaques, include several illustrative examples of utility of IVL in peripheral interventions, and discuss the future directions for adoption of the technique in peripheral interventions.


Asunto(s)
Litotricia , Calcificación Vascular , Acústica , Arterias , Humanos , Resultado del Tratamiento , Calcificación Vascular/diagnóstico por imagen , Calcificación Vascular/terapia
13.
Circ Cardiovasc Interv ; 14(6): e010258, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-34092091

RESUMEN

BACKGROUND: Older adults with comorbidities who are at extreme risk for surgical aortic valve replacement may be appropriate candidates for transcatheter aortic valve replacement (TAVR). We present the 5-year clinical, echocardiographic, and health status outcomes of such patients treated with CoreValve self-expanding supra-annular TAVR. METHODS: The CoreValve US Extreme Risk Pivotal Trial was a prospective, nonrandomized, single-arm clinical trial of TAVR at 41 sites in the United States. The primary outcome was all-cause mortality or major stroke. Secondary outcomes included echocardiographic parameters and patient-reported health status, assessed with the Kansas City Cardiomyopathy Questionnaire. RESULTS: Between February 2011 and August 2012, 639 patients with severe aortic stenosis at extreme surgical risk underwent attempted TAVR (mean age 82.8±8.4 years, 53% women, mean Society of Thoracic Surgeons Predicted Risk of Mortality 10.4±5.6%, 77% iliofemoral access). The 5-year Kaplan-Meier rate of death or major stroke was 72.6% ([95% CI, 68.4%­76.7%]; death 71.6%, major stroke 11.5%), with no significant differences according to access site. Among patients who survived 5 years, mean transvalvular gradient was 7.5±5.9 mm Hg, and 3.1% had moderate or severe aortic regurgitation. Health status measures improved significantly by 1 month after TAVR through 1 year (mean change in Kansas City Cardiomyopathy Questionnaire­Overall Summary score 24.8 points [95% CI, 22.4­27.2]). Beyond 1 year, the Kansas City Cardiomyopathy Questionnaire­Overall Summary score decreased gradually but remained significantly improved from pre-TAVR through 5 years of follow-up among surviving patients (mean change from baseline, 14.3 points [95% CI, 10.7­17.9]). CONCLUSIONS: Patients with severe aortic stenosis at extreme surgical risk who are treated with self-expanding supra-annular TAVR have high 5-year mortality. However, the short-term benefits of TAVR in terms of valve hemodynamics and quality of life are mostly preserved among surviving patients at 5 years, thereby supporting the continued use of TAVR in these challenging patients. REGISTRATION: https://www.clinicaltrials.gov; Unique identifier: NCT01240902.


Asunto(s)
Estenosis de la Válvula Aórtica , Calidad de Vida , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Femenino , Humanos , Masculino , Estudios Prospectivos , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos/epidemiología
14.
Clin Cardiol ; 43(12): 1547-1554, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33280140

RESUMEN

BACKGROUND: Cardiac injury is common in COVID-19 patients and is associated with increased mortality. However, it remains unclear if reduced cardiac function is associated with cardiac injury, and additionally if mortality risk is increased among those with reduced cardiac function in COVID-19 patients. HYPOTHESIS: The aim of this study was to assess cardiac function among COVID-19 patients with and without biomarkers of cardiac injury and to determine the mortality risk associated with reduced cardiac function. METHODS/RESULTS: This retrospective cohort study analyzed 143 consecutive COVID-19 patients who had an echocardiogram during hospitalization between March 1, 2020 and May 5, 2020. The mean age was 67 ± 16 years. Cardiac troponin-I was available in 131 patients and an increased value (>0.03 ng/dL) was found in 59 patients (45%). Reduced cardiac function, which included reduced left or right ventricular systolic function, was found in 40 patients (28%). Reduced cardiac function was found in 18% of patients without troponin-I elevation, 42% with mild troponin increase (0.04-5.00 ng/dL) and 67% with significant troponin increase (>5 ng/dL). Reduced cardiac function was also present in more than half of the patients on mechanical ventilation or those deceased. The in-hospital mortality of this cohort was 28% (N = 40). Using logistic regression analysis, we found that reduced cardiac function was associated with increased mortality with adjusted odds ratio (95% confidence interval) of 2.65 (1.18 to 5.96). CONCLUSIONS: Reduced cardiac function is highly prevalent among hospitalized COVID-19 patients with biomarkers of myocardial injury and is independently associated with mortality.


Asunto(s)
COVID-19/mortalidad , Lesiones Cardíacas/mortalidad , Troponina I/sangre , Anciano , Anciano de 80 o más Años , Biomarcadores/sangre , COVID-19/sangre , Causas de Muerte , Ecocardiografía Doppler de Pulso , Femenino , Lesiones Cardíacas/sangre , Mortalidad Hospitalaria , Humanos , Masculino , Persona de Mediana Edad , Evaluación de Resultado en la Atención de Salud , Estudios Retrospectivos
15.
JACC Cardiovasc Interv ; 13(21): 2482-2493, 2020 11 09.
Artículo en Inglés | MEDLINE | ID: mdl-33153565

RESUMEN

OBJECTIVES: The aim of this registry was to evaluate the feasibility and safety of transcatheter tricuspid valve implantation (TTVI) in patients with extreme surgical risk. BACKGROUND: Isolated tricuspid regurgitation (TR) surgery is associated with high in-hospital mortality. METHODS: Thirty consecutive patients (mean age 75 ± 10 years; 56% women) from 10 institutions, with symptomatic functional TR, had institutional and notified body approval for compassionate use of the GATE TTVI system. Baseline, discharge, and 30-day follow-up echocardiographic data and procedural, in-hospital, and follow-up clinical outcomes were collected. RESULTS: At baseline, all patients had multiple comorbidities, severe or greater TR, and reduced baseline right ventricular function. Technical success was achieved in 26 of 30 patients (87%). Device malpositioning occurred in 4 patients, with conversion to open heart surgery in 2 (5%). Of those who received the device, 100% had reductions in TR of ≥1, and 75% experienced reductions of ≥2 grades, resulting in 18 of 24 of patients (76%) with mild or less TR at discharge. All patients had mild or less central TR. There was continued improvement in TR grade between discharge and 30 days in 15 of 19 patients (79%). In-hospital mortality was 10%. At mean follow-up of 127 ± 82 days, 4 patients (13%) had died. Of patients alive at follow-up, 62% were in New York Heart Association functional class I or II, with no late device-related adverse events. CONCLUSIONS: Compassionate treatment of severe, symptomatic functional TR using a first-generation TTVI device is associated with significant reduction in TR and improvement in functional status with acceptable in-hospital mortality. Further studies are needed to determine the appropriate patient population and long-term outcomes with TTVI therapy.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Anciano , Anciano de 80 o más Años , Cateterismo Cardíaco , Femenino , Humanos , Masculino , Recuperación de la Función , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/cirugía
16.
JACC Cardiovasc Interv ; 13(2): 210-216, 2020 01 27.
Artículo en Inglés | MEDLINE | ID: mdl-31883715

RESUMEN

OBJECTIVES: The aim of this study was to report the 1-year results of transcatheter aortic valve replacement (TAVR) with the Edwards SAPIEN 3 (S3) valve in extremely large annuli. BACKGROUND: Favorable 30-day outcomes of S3 TAVR in annuli >683 mm2 have previously been reported. Pacemaker implantation rates were acceptable, and a larger left ventricular outflow tract and more eccentric annular anatomy were associated with increasing paravalvular leak. METHODS: From December 2013 to December 2018, 105 patients across 15 centers with mean area 721.3 ± 36.1 mm2 (range 683.5 to 852.0 mm2) underwent TAVR using an S3 device. Clinical, anatomic, and procedural characteristics were analyzed. One-year survival and echocardiographic follow-up were reached in 94.3% and 82.1% of patients, respectively. Valve Academic Research Consortium-2 30-day and 1-year outcomes were reported. RESULTS: The mean age was 76.9 ± 10.4 years, and Society of Thoracic Surgeons predicted risk score averaged 5.2 ± 3.4%. One-year overall mortality and stroke rates were 18.2% and 2.4%, respectively. Quality-of-life index improved from baseline to 30 days and at 1 year (p < 0.001 for both). Mild paravalvular aortic regurgitation occurred in 21.7% of patients, while moderate or greater paravalvular aortic regurgitation occurred in 4.3%. Mild and moderate or severe transvalvular aortic regurgitation occurred in 11.6% and 0%, respectively. Valve gradients remained stable at 1 year. CONCLUSIONS: S3 TAVR in annular areas >683 mm2 is feasible, with favorable mid-term outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Femenino , Hemodinámica , Humanos , Masculino , América del Norte , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/terapia , Recuperación de la Función , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
17.
Cardiovasc Revasc Med ; 20(7): 573-576, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-30224311

RESUMEN

BACKGROUND: Severely calcified lesions present many challenges to percutaneous coronary intervention (PCI). Orbital atherectomy (OA) aids vessel preparation and treatment of severely calcified coronary lesions. Same-day discharge (SDD) after PCI has numerous advantages including cost savings and improved patient satisfaction. The aim of this study is to evaluate the safety of SDD among patients treated with OA in a real-world setting. METHODS: This was a single-center retrospective analysis of patients undergoing OA. In-hospital and 30-day outcomes were assessed for major adverse cardiac events (MACE), device-related events and hospital readmissions. RESULTS: There were 309 patients treated with OA of whom 94 had SDD (30.4%). Among SDD patients, there were no acute procedural complications and all patients were safely discharged on the day of the procedure. MACE at 30 days occurred in 1 patient (1.06%) due to major bleeding in the setting of a gastric arteriovenous malformation. There were 8 patients with unplanned 30-day readmissions (8.5%). CONCLUSION: SDD after OA in patients with heavily calcified lesions appears to be safe, with low rates of adverse events and readmissions in select patients. In patients with SDD treated with OA, unplanned readmission occurred at a similar rate to the statewide average 30-day PCI readmission rate. Larger studies are needed to confirm the safety of this treatment paradigm and the potential cost savings.


Asunto(s)
Aterectomía Coronaria , Enfermedad de la Arteria Coronaria/terapia , Tiempo de Internación , Alta del Paciente , Intervención Coronaria Percutánea , Calcificación Vascular/terapia , Anciano , Anciano de 80 o más Años , Aterectomía Coronaria/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Readmisión del Paciente , Seguridad del Paciente , Intervención Coronaria Percutánea/efectos adversos , Sistema de Registros , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento , Calcificación Vascular/diagnóstico por imagen
20.
JAMA Cardiol ; 4(8): 810-814, 2019 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-31215985

RESUMEN

Importance: Surgical aortic valve replacement (SAVR) has increased risk for patients with aortic stenosis (AS) and a history of coronary artery bypass graft (CABG) surgery. Transcatheter aortic valve replacement (TAVR) may be an alternative. Objective: To compare TAVR with SAVR outcomes in patients at intermediate operative risk with prior CABG surgery. Design, Setting, and Participants: In this post hoc analysis of the Surgical Replacement and Transcatheter Aortic Valve Implantation (SURTAVI) noninferiority randomized clinical trial, patients with severe, symptomatic AS at intermediate operative risk were enrolled from 87 centers across the United States, Europe, and Canada from June 2012 to June 2016 and followed-up with up to July 2017. Those with a history of CABG surgery were considered for analysis. Data were analyzed from September to December 2017. Interventions: A total of 1746 patients were enrolled and randomized 1:1 to self-expanding TAVR or SAVR. An implant was attempted in 1660 patients, of whom 273 had prior CABG surgery, including 136 who underwent attempted TAVR and 137 who underwent attempted SAVR. Main Outcomes and Measures: The primary outcome was all-cause mortality or disabling stroke at 1-year follow-up. Efficacy outcomes included quality of life, measured using the Kansas City Cardiomyopathy Questionnaire at 30 days, 6 months, and 1 year, and distance walked in 6 minutes, measured using the 6-minute walk test at 30 days and 1 year. Results: Of the 136 patients in the TAVR cohort, 111 (81.6%) were male, and the mean (SD) age was 76.9 (6.5) years; of the 137 in the SAVR cohort, 117 (85.4%) were male, and the mean (SD) age was 76.6 (6.5) years. The mean (SD) Society of Thoracic Surgeons Predicted Risk of Mortality score was 5.0% (1.6%) in the TAVR cohort and 5.2% (1.7%) in the SAVR cohort. All-cause mortality or disabling stroke at 1-year follow-up was 8.9% (95% CI, 5.2-15.2) in the TAVR cohort and 6.7% (95% CI, 3.5-12.8) in the SAVR cohort (log-rank P = .53). Compared with patients receiving SAVR, the mean (SD) Kansas City Cardiomyopathy Questionnaire summary score was significantly better among patients receiving TAVR at 30 days (81.4 [19.2] vs 69.7 [22.6]; P < .001); treatments were similar at 1 year (85.7 [14.6] vs 82.8 [18.4]; P = .19). Compared with patients in the SAVR cohort, those in the TAVR cohort showed greater mean (SD) improvement in distance walked at 1 year (48.3 [120.6] m vs 16.8 [88.7] m; P = .04). Conclusions and Relevance: Both TAVR and SAVR were safe for intermediate-risk patients with AS and prior CABG surgery. The transcatheter approach facilitated faster improvement in quality of life and better exercise capacity at 1-year follow-up. Trial Registration: ClinicalTrials.gov identifier: NCT01586910.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Puente de Arteria Coronaria , Implantación de Prótesis de Válvulas Cardíacas/métodos , Anciano , Anciano de 80 o más Años , Estudios de Cohortes , Femenino , Humanos , Masculino , Medición de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA