Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Pediatr Cardiol ; 2024 Jul 13.
Artículo en Inglés | MEDLINE | ID: mdl-39003423

RESUMEN

The prevalence of interatrial communications in newborns, i.e., patent foramen ovale or atrial septal defect, was previously reported to be between 24 and 92%, but the area has been impeded by lack of a universal classification method. A recently published novel echocardiographic diagnostic algorithm for systematic classification of interatrial communications had inter-and intraobserver agreements superior to standard expert assessment. This study aimed to determine the prevalence of subtypes of interatrial communications on transthoracic echocardiography in newborns. Echocardiograms of newborns aged 0-30 days were prospectively collected in the population-based cohort study Copenhagen Baby Heart Study in 2017-2018 and analyzed according to the new diagnostic algorithm, classifying interatrial communications into three subtypes of patent foramen ovale and three subtypes of atrial septal defects. Echocardiograms from 15,801 newborns were analyzed; 3416 (21.6%) were excluded due to suboptimal image quality or severe structural heart disease (n = 3), leaving 12,385 newborns (aged 12 [interquartile range 8; 15] days, 48.2% female) included in the study. An interatrial communication was detected in 9766 (78.9%) newborns. According to the algorithm, 9029 (72.9%) had a patent foramen ovale, while 737 (6.0%) fulfilled criteria for an atrial septal defect, further divided into subtypes. An interatrial communication was seen on echocardiography in almost 80% of newborns aged 0-30 days. Patent foramen ovale was 12 times more frequent than atrial septal defects. The observed prevalence of atrial septal defects was higher than previously reported. Follow up studies could distinguish which interatrial communications require follow-up or intervention. ClinicalTrial.gov, NCT02753348, posted April 27, 2016, [ https://classic.clinicaltrials.gov/ct2/show/NCT02753348 ].

2.
Cardiol Young ; 33(10): 1942-1949, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36408693

RESUMEN

BACKGROUND: An interatrial communication is present in most neonates. The majority are considered the "normal" patency of the oval foramen, while a minority are abnormal atrial septal defects. Differentiation between the two with transthoracic echocardiography may be challenging, and no generally accepted method of classification is presently available. We aimed to develop and determine the reliability of a new classification of interatrial communications in newborns. METHODS AND RESULTS: An algorithm was developed based on echocardiographic criteria from 495 newborns (median age 11[8;13] days, 51.5% females). The algorithm defines three main categories: patency of the oval foramen, atrial septal defect, and no interatrial communication as well as several subtypes. We found an interatrial communication in 414 (83.6%) newborns. Of these, 386 (93.2%) were categorised as patency of the oval foramen and 28 (6.8%) as atrial septal defects.Echocardiograms from another 50 newborns (median age 11[8;13] days, 36.0% female), reviewed by eight experts in paediatric echocardiography, were used to assess the inter- and intraobserver variation of classification of interatrial communications into patency of the oval foramen and atrial septal defect, with and without the use of the algorithm. Review with the algorithm gave a substantial interobserver agreement (kappa = 0.66), and an almost perfect intraobserver agreement (kappa = 0.82). Without the use of the algorithm, the interobserver agreement between experienced paediatric cardiologists was low (kappa = 0.20). CONCLUSION: A new algorithm for echocardiographic classification of interatrial communications in newborns produced almost perfect intraobserver and substantial interobserver agreement. The algorithm may prove useful in both research and clinical practice.


Asunto(s)
Tabique Interatrial , Foramen Oval , Defectos del Tabique Interatrial , Niño , Humanos , Recién Nacido , Femenino , Masculino , Reproducibilidad de los Resultados , Defectos del Tabique Interatrial/diagnóstico por imagen , Tabique Interatrial/diagnóstico por imagen , Ecocardiografía
3.
Circ Cardiovasc Imaging ; 15(6): e014159, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35727876

RESUMEN

BACKGROUND: Left ventricular noncompaction (LVNC) is characterized by excessive trabeculations of the LV and may be associated with reduced systolic function or severe adverse outcomes. Several aspects remain to be elucidated; there is controversy to whether LVNC cardiomyopathy is a distinct cardiomyopathy caused by failure of the spongy fetal myocardium to condense during fetal development or acquired later in life as a morphological trait associated with other types of cardiomyopathy; the prevalence in unselected populations is unknown and the distinction between normal variation and pathology remains to be defined. In this study, we aimed to determine the prevalence of LVNC and the association to LV systolic function in a large, population-based cohort of neonates. In addition, we assessed the normal ratio of noncompact to compact (NC:C) myocardium in 150 healthy neonates. METHODS: Echocardiographic data were prospectively collected in the population study Copenhagen Baby Heart Study. The ratio of NC:C was measured in 12 ventricular segments. LVNC was defined as NC:C ≥2 in at least one segment. Neonates with LVNC were matched 1:10 to controls on sex, gestational age, and weight and age at the examination day. RESULTS: In total, 25 590 neonates (52% males, median age 11 [interquartile range, 7-15] days) underwent echocardiography. Among 21 133 with satisfactory visualization of ventricular segments, we identified a prevalence of LVNC of 0.076% (95% CI, 0.047-0.123). LV ejection fraction was lower in neonates with LVNC compared with matched controls (median 49.5 versus 59.0%; P<0.0001). In neonates with otherwise healthy hearts, the median NC:C ratio ranged from 0.0 to 0.7 and the 99th percentiles from 1.0 to 1.9 for each of the 12 segments. CONCLUSIONS: The prevalence of LVNC based on neonatal echocardiography was 0.076%. LVNC was associated with lower LV systolic function. The findings in normal newborns support the cutoff NC:C ≥2 as an appropriate diagnostic criterion. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT02753348.


Asunto(s)
Cardiomiopatías , Cardiopatías Congénitas , Cardiomiopatías/diagnóstico por imagen , Cardiomiopatías/epidemiología , Ecocardiografía , Femenino , Cardiopatías Congénitas/diagnóstico por imagen , Cardiopatías Congénitas/epidemiología , Humanos , Recién Nacido , Masculino , Prevalencia , Función Ventricular Izquierda
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA