Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
Asunto de la revista
Intervalo de año de publicación
1.
Molecules ; 29(4)2024 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-38398532

RESUMEN

Protein adulteration is a common fraud in the food industry due to the high price of protein sources and their limited availability. Total nitrogen determination is the standard analytical technique for quality control, which is incapable of distinguishing between protein nitrogen and nitrogen from non-protein sources. Three benchtops and one handheld near-infrared spectrometer (NIRS) with different signal processing techniques (grating, Fourier transform, and MEM-micro-electro-mechanical system) were compared with detect adulteration in protein powders at low concentration levels. Whey, beef, and pea protein powders were mixed with a different combination and concentration of high nitrogen content compounds-namely melamine, urea, taurine, and glycine-resulting in a total of 819 samples. NIRS, combined with chemometric tools and various spectral preprocessing techniques, was used to predict adulterant concentrations, while the limit of detection (LOD) and limit of quantification (LOQ) were also assessed to further evaluate instrument performance. Out of all devices and measurement methods compared, the most accurate predictive models were built based on the dataset acquired with a grating benchtop spectrophotometer, reaching R2P values of 0.96 and proximating the 0.1% LOD for melamine and urea. Results imply the possibility of using NIRS combined with chemometrics as a generalized quality control tool for protein powders.


Asunto(s)
Nitrógeno , Espectroscopía Infrarroja Corta , Animales , Bovinos , Espectroscopía Infrarroja Corta/métodos , Polvos , Suero Lácteo , Urea , Contaminación de Alimentos/análisis
2.
Environ Res ; 213: 113638, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35705130

RESUMEN

The drinking water scarcity is posing a threat to mankind, hence better water quality management methods are required. Magnetic water treatment, which has been reported to improve aesthetic water quality and reduce scaling problems, can be an important addition to the traditional disinfectant dependent treatment. Despite the extensive market application opportunities, the effect of magnetic fields on (microbial) drinking water communities and subsequently the biostability is still largely unexplored, although the first patent was registered already 1945. Here flow cytometry was applied to assess the effect of weak magnetic fields (≤10 G) with strong gradients (≈800 G/m) on drinking water microbial communities. Drinking water was collected from the tap and placed inside the magnetic field (treated) and 5 m away from the magnet to avoid any background interferences (control) using both a static set-up and a shaking set-up. Samples were collected during a seven-day period for flow cytometry examination. Additionally, the effects of magnetic fields on the growth of Pseudomonas aeruginosa in autoclaved tap water were examined. Based on the fluorescent intensity of the stained nucleic acid content, the microbial cells were grouped into low nucleic acid content (LNA) and high nucleic acid content (HNA). Our results show that the LNA was dominant under nutrient limited condition while the HNA dominates when nutrient is more available. Such behavior of LNA and HNA matches well with the long discussed r/K selection model where r-strategists adapted to eutrophic conditions and K-strategists adapted to oligotrophic conditions. The applied magnetic fields selectively promote the growth of LNA under nutrient rich environment, which indicates a beneficial effect on biostability enhancement. Inhibition on an HNA representative Pseudomonas aeruginosa has also been observed. Based on our laboratory observations, we conclude that magnetic field treatment can be a sustainable method for microbial community management with great potential.


Asunto(s)
Agua Potable , Ácidos Nucleicos , Purificación del Agua , Bacterias , Fenómenos Magnéticos , Microbiología del Agua , Purificación del Agua/métodos
3.
Molecules ; 25(9)2020 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-32397462

RESUMEN

Aquaphotomics utilizes water-light interaction for in-depth exploration of water, its structure and role in aqueous and biologic systems. The aquagram, a major analytical tool of aquaphotomics, allows comparison of water molecular structures of different samples by comparing their respective absorbance spectral patterns. Temperature is the strongest perturbation of water changing almost all water species. To better interpret and understand spectral patterns, the objective of this work was to develop a novel, temperature-scaled aquagram that provides standardized information about changes in water molecular structure caused by solutes, with its effects translated to those which would have been caused by respective temperature changes. NIR spectra of Milli-Q water in the temperature range of 20-70 °C and aqueous solutions of potassium chloride in concentration range of 1 to 1000 mM were recorded to demonstrate the applicability of the proposed novel tool. The obtained results presented the influence of salt on the water molecular structure expressed as the equivalent effect of temperature in degrees of Celsius. The temperature-based aquagrams showed the well-known structure breaking and structure making effects of salts on water spectral pattern, for the first time presented in the terms of temperature influence on pure water. This new method enables comparison of spectral patterns providing a universal tool for evaluation of various bio-aqueous systems which can provide better insight into the system's functionality.


Asunto(s)
Cloruro de Potasio/química , Agua/química , Estructura Molecular , Espectroscopía Infrarroja Corta , Temperatura
4.
Front Chem ; 6: 363, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30211151

RESUMEN

Aquaphotomics is a novel scientific discipline involving the study of water and aqueous systems. Using light-water interaction, it aims to extract information about the structure of water, composed of many different water molecular conformations using their absorbance bands. In aquaphotomics analysis, specific water structures (presented as water absorbance patterns) are related to their resulting functions in the aqueous systems studied, thereby building an aquaphotome-a database of water absorbance bands and patterns correlating specific water structures to their specific functions. Light-water interaction spectroscopic methods produce complex multidimensional spectral data, which require data processing and analysis to extract hidden information about the structure of water presented by its absorbance bands. The process of extracting information from water spectra in aquaphotomics requires a field-specific approach. It starts with an appropriate experimental design and execution to ensure high-quality spectral signals, followed by a multitude of spectral analysis, preprocessing and chemometrics methods to remove unwanted influences and extract water absorbance spectral pattern related to the perturbation of interest through the identification of activated water absorbance bands found among the common, consistently repeating and highly influential variables in all analytical models. The objective of this paper is to introduce the field of aquaphotomics and describe aquaphotomics multivariate analysis methodology developed during the last decade. Through a worked-out example of analysis of potassium chloride solutions supported by similar approaches from the existing aquaphotomics literature, the provided instruction should give enough information about aquaphotomics analysis i.e. to design and perform the experiment and data analysis as well as to represent water absorbance spectral pattern using various forms of aquagrams-specifically designed aquaphotomics graphs. The explained methodology is derived from analysis of near infrared spectral data of aqueous systems and will offer a useful and new tool for extracting data from informationally rich water spectra in any region. It is the hope of the authors that with this new tool at the disposal of scientists and chemometricians, pharmaceutical and biomedical spectroscopy will substantially progress beyond its state-of-the-art applications.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA