Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 249
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Eur Heart J ; 45(8): 613-625, 2024 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-38036414

RESUMEN

BACKGROUND AND AIMS: HeartMate 3 (HM3) is a fully magnetically levitated continuous flow left ventricular assist device, which received CE marking in 2015. The ELEVATE Registry was initiated to collect real-world outcomes in patients treated with HM3 post-CE Mark approval. METHODS: A total of 540 subjects implanted at 26 centres between March 2015 and February 2017 were included in this registry. Of these, 463 received the device as a primary implant (primary implant cohort, PIC), 19 as a pump exchange (pump exchange cohort), and in 58 patients, only anonymized survival data were collected (anonymized cohort, AC). Patients in the PIC contributed to the baseline demographics, survival, adverse events, quality of life (QoL) (EuroQoL-5 Dimensions-5 Levels visual analogue scale), and functional capacity (6 min walk distance) assessments, while patients in the AC contributed only to survival. RESULTS: Primary implant cohort patients had a mean age of 56 years and were predominantly male (89%) with 48% ischaemic aetiology. The majority of subjects was designated bridge to transplant (66%) and had INTERMACS Profiles 1-3 (70%). At baseline, the subjects had poor functional capacity (104 ± 140 m) and impaired QoL (35 ± 19 points). The overall survival rate of the PIC was 63.3% and survival free of stroke was 58.1% at 5 years. Significant improvements in functional capacity and QoL were observed and maintained for 5 years (301 ± 131 m and 64 ± 20 points, respectively). CONCLUSIONS: Real-world data from the ELEVATE registry demonstrate an overall survival rate for primary implants of 63.3%. In the PIC, reductions in adverse events for patients in the extended follow-up and improved QoL and functional capacity were observed at 5 years in this patient population with advanced heart failure.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Humanos , Masculino , Persona de Mediana Edad , Femenino , Corazón Auxiliar/efectos adversos , Calidad de Vida , Resultado del Tratamiento , Estudios Prospectivos , Sistema de Registros
2.
Artif Organs ; 48(1): 83-90, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37723833

RESUMEN

BACKGROUND: Driveline infections (DLI) are a serious complication in patients with left ventricular assist devices (LVAD). Apart from the differentiation between superficial and deep DLI, there is no consensus on the classification of the severity of DLI. Little is known about risk factors and typical bacteria causing DLI in centrifugal-flow LVADs. METHODS: In this single-center study with 245 patients, DLI were classified by their local appearance using a modification of a score suggested by the Sharp Memorial group. The driveline exit site was inspected routinely every 6 months. RESULTS: Severe DLI were detected in 34 patients (15%) after 6 months and in 24 patients (22%) after 24 months. The proportion of patients with DLI increased significantly during the follow-up (p = 0.0096). The most common bacteria in local smears were Corynebacterium, coagulase-negative Staphylococcus, and Staphylococcus aureus. Fifty-nine patients were hospitalized more than once for DLI. In these patients, S. aureus was the most common bacterium. It was also the most common bacterium in blood cultures. Higher BMI, no partnership, and a HeartMate 3 device were identified as risk factors for DLI in a multivariable cause-specific Cox regression. CONCLUSION: This study is a standardized analysis of DLI in a large cohort with centrifugal-flow LVADs.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Infecciones Relacionadas con Prótesis , Humanos , Incidencia , Corazón Auxiliar/efectos adversos , Staphylococcus aureus , Infecciones Relacionadas con Prótesis/epidemiología , Infecciones Relacionadas con Prótesis/etiología , Estudios Retrospectivos , Insuficiencia Cardíaca/etiología
3.
Artif Organs ; 2024 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-38803239

RESUMEN

BACKGROUND: Stroke after durable left ventricular assist device (d-LVAD) implantation portends high mortality. The incidence of ischemic and hemorrhagic stroke and the impact on stroke outcomes of temporary mechanical circulatory support (tMCS) management among patients requiring bridge to d-LVAD with micro-axial flow-pump (mAFP, Abiomed) is unsettled. METHODS: Consecutive patients, who underwent d-LVAD implantation after being bridged with mAFP at 19 institutions, were retrospectively included. The incidence of early ischemic and hemorrhagic stroke after d-LVAD implantation (<60 days) and association of pre-d-LVAD characteristics and peri-procedural management with a specific focus on tMCS strategies were studied. RESULTS: Among 341 patients, who underwent d-LVAD implantation after mAFP implantation (male gender 83.6%, age 58 [48-65] years, mAFP 5.0/5.5 72.4%), the early ischemic stroke incidence was 10.8% and early hemorrhagic stroke 2.9%. The tMCS characteristics (type of mAFP device and access, support duration, upgrade from intra-aortic balloon pump, ECMELLA, ECMELLA at d-LVAD implantation, hemolysis, and bleeding) were not associated with ischemic stroke after d-LVAD implant. Conversely, the device model (mAFP 2.5/CP vs. mAFP 5.0/5.5: HR 5.6, 95%CI 1.4-22.7, p = 0.015), hemolysis on mAFP support (HR 10.5, 95% CI 1.3-85.3, p = 0.028) and ECMELLA at d-LVAD implantation (HR 5.0, 95% CI 1.4-18.7, p = 0.016) were associated with increased risk of hemorrhagic stroke after d-LVAD implantation. Both early ischemic (HR 2.7, 95% CI 1.9-4.5, p < 0.001) and hemorrhagic (HR 3.43, 95% CI 1.49-7.88, p = 0.004) stroke were associated with increased 1-year mortality. CONCLUSIONS: Among patients undergoing d-LVAD implantation following mAFP support, tMCS characteristics do not impact ischemic stroke occurrence, while several factors are associated with hemorrhagic stroke suggesting a proactive treatment target to reduce this complication.

4.
Artif Organs ; 47(11): 1786-1793, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37649286

RESUMEN

BACKGROUND: As the incidence of heart failure in developed countries is on the rise, mechanical circulatory support (MCS) often remains the only treatment option for patients with end-stage heart failure and is well established worldwide. Even though VAD coordinators play a key role in VAD programs, their responsibilities and daily duties are not clearly defined and characterized. Recently published data from the first 5-year multicenter clinical trial assessing experience with the HeartMate 3 left ventricular system (Abbott, Abbott Park, IL) show an overall survival of 61% at 5 years. When it comes to possible improvements to these systems, it is necessary for developers not only to know the status quo but also to determine and consider the visions and wishes of those individuals who take care of patients, provide education and deal with possible complications. This would be helpful a meaningful effort towards implementing a standard of care. METHODS: To fill this knowledge gap, we conducted an online survey using the SurveyMonkey tool, addressing representatives of programs implanting VADs worldwide. Representatives answered a standardized block of 14 questions and were asked to provide responses within 3 months. RESULTS: A total of 91 VAD coordinators from centers of various regions of the world completed the survey. The majority came from European countries. The numbers of patients followed up by the centers ranged from <20 to 390 patients. The majority of VAD coordinators had a nursing background (68%). Seventy-seven percent of the centers operate a 24-h hotline and 3-monthly visits to the outpatient department are most common. Fifty-nine percent of the centers do not use an infection scoring system for driveline wound care. The majority of the centers indicated that an optimized follow-up concept including wound care, medication, and social care is crucial and the key issue for an improved outcome. Smaller components and intensified psychosocial support ranked highest in questions about how to improve quality of life. Surprisingly, the future prospects of telemetric monitoring were not rated high in significance. CONCLUSIONS: There is a wide variability in the composition and tasks of VAD programs worldwide. Implementing a standard of care and improving psychosocial care as well as equipment is regarded most important to improve outcomes and quality of life. From the point of view of those responsible, the significance of telemetric monitoring seemed overrated.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Humanos , Corazón Auxiliar/efectos adversos , Calidad de Vida , Insuficiencia Cardíaca/cirugía , Encuestas y Cuestionarios , Europa (Continente) , Resultado del Tratamiento
5.
Lipids Health Dis ; 22(1): 138, 2023 Aug 29.
Artículo en Inglés | MEDLINE | ID: mdl-37644527

RESUMEN

BACKGROUND: Oxylipins, the oxidative metabolites of polyunsaturated fatty acids (PUFAs), serve as key mediators of oxidative stress, inflammatory responses, and vasoactive reactions in vivo. Our previous work has established that hemodialysis affects both long chain fatty acids (LCFAs) and oxylipins in plasma and erythrocytes to varying degrees, which may be responsible for excess cardiovascular complications in end-stage renal disease. In this study, we aimed to determine changes in blood oxylipins during cardiopulmonary bypass (CPB) in patients undergoing cardiac surgery to identify novel biomarkers and potential metabolites of CPB-related complications. We tested the hypothesis that CPB would differentially affect plasma oxylipins and erythrocytes oxylipins. METHODS: We conducted a prospective observational study of 12 patients undergoing elective cardiac surgery with expected CPB procedure. We collected venous and arterial blood samples before CPB, 15 and 45 min after the start of CPB, and 60 min after the end of CPB, respectively. Oxylipins profiling in plasma and erythrocytes was achieved using targeted HPLC-MS mass spectrometry. RESULTS: Our results revealed that most venous plasma diols and hydroxy- oxylipins decreased after CPB initiation, with a continuous decline until the termination of CPB. Nevertheless, no statistically significant alterations were detected in erythrocytes oxylipins at all time points. CONCLUSIONS: CPB decreases numerous diols and hydroxy oxylipins in blood plasma, whereas no changes in erythrocytes oxylipins are observed during this procedure in patients undergoing cardiac surgery. As lipid mediators primarily responsive to CPB, plasma diols and hydroxy oxylipins may serve as potential key biomarkers for CPB-related complications.


Asunto(s)
Puente Cardiopulmonar , Oxilipinas , Humanos , Puente Cardiopulmonar/efectos adversos , Plasma , Eritrocitos , Ácidos Grasos
6.
Eur Heart J Suppl ; 25(Suppl I): I39-I43, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38093770

RESUMEN

The additional implantation of a micro-axial flow pump (mAFP) in patients receiving extracorporeal life support by a veno-arterial extracorporeal membrane oxygenation (V-A ECMO) for cardiogenic shock (CS) has gained interest in recent years. Thus far, retrospective propensity score-matched studies, case series, and meta-analyses have consistently shown an improved survival in patients treated with the so-called ECMELLA concept. The pathophysiological context is based on the modification of V-A ECMO-related side effects and the additive benefit of myocardial unloading. From this point of view, knowledge and detection of these pathophysiological mechanisms are of utmost importance to successfully manage mechanical circulatory support in CS. In this article, we describe best practices for the indication of the two devices as well as escalation and de-escalation approaches including implantation and explantation strategies that are key for success.

7.
Eur Heart J Suppl ; 25(Suppl I): I32-I38, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38093771

RESUMEN

Cardiogenic shock (CS) is a life-threatening condition characterized by a state of inadequate systemic tissue perfusion caused by cardiac dysfunction. When to implement, change, or remove the use of a temporary mechanical circulatory support (tMCS) in patients with CS is dependent on the aetiology and severity. Here, patient scenarios underlying the need to escalate, de-escalate, wean, or bridge from tMCS devices are taken into consideration by interdisciplinary heart failure and CS teams. This includes a comprehensive review of and focus on the rationale for specific device escalation and de-escalation strategies, device selection, and general management.

8.
Surg Technol Int ; 432023 12 29.
Artículo en Inglés | MEDLINE | ID: mdl-38237112

RESUMEN

Recently, temporary mechanical circulatory support (tMCS) has been increasingly used for cardiogenic shock therapy. Originally designed as a bail-out option for patients who could not be weaned from cardiopulmonary bypass, the indications for tMCS have been expended and now enable us to support a wide range of patients with various cardiac pathologies. Modern tMCS devices include microaxial flow pumps (mAFP) which are small, versatile systems that can provide both acute cardiac support and cardiac protection for high-risk interventions. In this paper, we review different surgical implantation techniques with modern mAFP as well as specific aspects of preoperative indications and patient evaluation.

9.
Eur Biophys J ; 51(2): 171-184, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34477935

RESUMEN

The primary aim of this article is to review the clinical challenges related to the supply of power in implanted left ventricular assist devices (LVADs) by means of transcutaneous drivelines. In effect of that, we present the preventive measures and post-operative protocols that are regularly employed to address the leading problem of driveline infections. Due to the lack of reliable wireless solutions for power transfer in LVADs, the development of new driveline configurations remains at the forefront of different strategies that aim to power LVADs in a less destructive manner. To this end, skin damage and breach formation around transcutaneous LVAD drivelines represent key challenges before improving the current standard of care. For this reason, we assess recent strategies on the surface functionalization of LVAD drivelines, which aim to limit the incidence of driveline infection by directing the responses of the skin tissue. Moreover, we propose a class of power transfer systems that could leverage the ability of skin tissue to effectively heal short diameter wounds. In this direction, we employed a novel method to generate thin conductive wires of controllable surface topography with the potential to minimize skin disruption and eliminate the problem of driveline infections. Our initial results suggest the viability of the small diameter wires for the investigation of new power transfer systems for LVADs. Overall, this review uniquely compiles a diverse number of topics with the aim to instigate new research ventures on the design of power transfer systems for IMDs, and specifically LVADs.


Asunto(s)
Corazón Auxiliar
10.
Clin Transplant ; 36(7): e14733, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35652422

RESUMEN

BACKGROUND: A growing proportion of transplant donors and recipients have a history of COVID-19 infection. This study sought to characterize clinical practice after recipient or donor COVID-19 infection. METHODS: An online survey was distributed to heart transplant clinicians through a professional society message board and social media. Responses were collected between September 29 and November 5, 2021. RESULTS: There were 222 health care professionals (68% transplant cardiologists, 22% transplant surgeons, 10% other) across diverse geographic regions who completed the survey. While there was significant variation in donor acceptance, as it relates to past and current COVID-19 infection, the respondents were fairly cautious: 28% would not typically accept a donor with a history of COVID-19 regardless of the infection course and > 80% would not accept donors who had evidence of myocardial dysfunction during past COVID-19 infection, or who died of COVID-19 or its complications. The timing of candidate reactivation on the waiting list after COVID-19 infection also varied and often diverged from scenarios addressed by social guidelines. Eighty-one percent of the respondents felt COVID-19 vaccine should be mandatory before transplant, but this rate varied by geographic region. CONCLUSION: Our results reflect evolving experience of the heart transplant field at a time of lack of high-quality evidence. In the absence of longer-term outcome data for donors and transplant candidates with history of COVID-19 infection, clinicians remain cautious; however, this approach will likely need to be refined as an increasing proportion of the population will continue to be infected with COVID-19.


Asunto(s)
COVID-19 , Trasplante de Corazón , COVID-19/epidemiología , Vacunas contra la COVID-19 , Humanos , Encuestas y Cuestionarios , Donantes de Tejidos , Receptores de Trasplantes
11.
Artif Organs ; 46(8): 1573-1584, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35230721

RESUMEN

BACKGROUND: Despite numerous design iterations, thrombus formation at the inflow cannula of continuous-flow left ventricular assist devices remains an unsolved problem. We systematically investigated the impact of cannula surface on thrombus formation. METHODS: Thrombus appearance was photographically documented in 177 explanted hearts with the polished (N = 46) or sintered (N = 131) inflow cannula of the Medtronic HeartWare™ HVAD™ System. Thrombus load was compared for both inflow cannula types. Mean thrombus length was correlated with protruding cannula length. Support duration and the extent of thrombus growth were examined. The prevalence of thrombi at the left ventricular entry site and at the sintered-to-polished transition zone was correlated with left ventricular geometry and hemodynamic parameters. RESULTS: Polished inflow cannulas showed a greater percentage and also a greater mean length of thrombus formation at the entry site than sintered cannulas (91.3% [Pol] vs. 36.7% [sTi]; p < 0.0001; mean 7.6 mm vs. 1.9 mm; p < 0.0001). A comparison of the early postoperative period (POD1-90) with long-term support (POD>90) showed an increase in thrombus length originating from the transition zone (1.96 ± 3.41 mm vs. 3.03 ± 2.91 mm; p = 0.013). CONCLUSIONS: A sintered titanium surface at the entry site is crucial to enable anchoring of myocardial tissue to the cannula. As thrombus growth progresses on polished surfaces, a greater sintered length seems to be beneficial. After an initial three-month healing period, thrombus load appears to decline during prolonged support duration at the sintered entry site but not at the transition zone.


Asunto(s)
Corazón Auxiliar , Trombosis , Cánula/efectos adversos , Ventrículos Cardíacos/cirugía , Corazón Auxiliar/efectos adversos , Hemodinámica , Humanos , Trombosis/etiología
12.
Artif Organs ; 46(1): 155-158, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34605037

RESUMEN

A patient was admitted in cardiogenic shock and a constant decrease of pump flow requiring combined inotropic support. To evaluate the cause, echocardiography and a ramp test were performed. The results suggested a LVAD related problem - particularly a suspected outflow graft obstruction. Wether CT scan nor angiography confirmed the assumption. However, a post-mortem LVAD examination revealed an outflow obstruction caused by a fungal thrombus formation invisible for standard imaging procedures.


Asunto(s)
Candida/aislamiento & purificación , Corazón Auxiliar/microbiología , Choque Cardiogénico/etiología , Trombosis/microbiología , Candidiasis/patología , Ecocardiografía , Corazón Auxiliar/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Isquemia Miocárdica/terapia , Tomografía Computarizada por Rayos X
13.
Artif Organs ; 46(5): 813-826, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-34904255

RESUMEN

BACKGROUND: We investigated the clinical outcomes after cardiac valvular surgery procedures concomitant (CCPs) with left ventricular assist device (LVAD) implantation compared to propensity score (PS) matched controls using the European Registry for Patients with Mechanical Circulatory Support (EUROMACS) data. METHODS: Between 2006 and 2018, 2760 continuous-flow LVAD patients were identified. Of these, 533 underwent a CCP during the LVAD implant. RESULTS: Cardiopulmonary bypass time (p < 0.001) and time for implant (p < 0.001) were both significantly longer in the LVAD+CCP group. Hospital mortality was comparable between the two groups from the unmatched population (15.7% vs. 14.1%, p = 0.073). Similarly, short-to-mid-term survival was similar in both groups, with 1-year, 3-year, and 5-year survival rates of 67.9%, 48.2%, and 27.7% versus 66.4%, 46.1%, and 26%, respectively (log-rank, p = 0.25). The results were similar in the PS-matched population. Hospital mortality was comparable between the two groups (18.9% vs. 17.4%, p = 0.074). The short-to-mid-term Kaplan-Meier survival analysis was similar for both groups, with 1-year, 3-year, and 5-year survival rates of 63.4%, 49.2%, and 24.7% versus 66.5%, 46%, and 25.1%, respectively (log-rank, p = 0.81). In the unmatched population, LVAD+CCP patients had longer intensive care unit (ICU) stays (p < 0.0001), longer mechanical ventilation time (p = 0.001), a higher rate of temporary right ventricular assist device (RVAD) support (p = 0.033), and a higher rate of renal replacement therapy (n = 35, 6.6% vs. n = 89, 4.0%, p = 0.014). In the PS-matched population, the LVAD+CCP patients had longer ICU stays (p = 0.019) and longer mechanical ventilation time (p = 0.002). CONCLUSIONS: The effect of additive valvular procedures (CCPs) does not seem to affect short-term survival, significantly, based on our registry data analysis. However, the decision to perform CCPs should be balanced with the projected type of surgery and preoperative characteristics. LVAD+CCP patients remain a delicate population and adverse device-related events should be strictly monitored and managed.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/cirugía , Corazón Auxiliar/efectos adversos , Humanos , Sistema de Registros , Estudios Retrospectivos , Resultado del Tratamiento
14.
Artif Organs ; 46(5): 908-921, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-34904259

RESUMEN

BACKGROUND: Cardiopulmonary bypass (CPB) during left ventricular assist device (LVAD) implantation provides circulatory support and allows for safe inspection of the left ventricle (LV), whereas circulatory support by veno-arterial extracorporeal life support (va-ECLS) or off-pump implantation may reduce postoperative bleeding and inflammatory response. METHODS: Retrospective analysis of 616 consecutive adult patients who received an LVAD via median sternotomy between January 1, 2015 and December 31, 2019. All patients undergoing concomitant intracardiac procedures other than closure of persistent foramen ovale or atrial septal defect and redo surgeries were excluded from the analysis. The remaining patients (n = 222) were divided into two groups and 1:1 propensity score-matched regarding preoperative parameters: patients who underwent LVAD implantation with LV inspection employing CPB (CPB group, n = 62) and without LV inspection on va-ECLS or off-pump (non-CPB group, n = 62). RESULTS: The groups were well balanced with regard to preoperative baseline characteristics (standard difference <0.1). Patients in the CPB group required more blood transfusions (median 2 vs. 0 units, p = 0.031) during surgery and in the first 24 h afterwards. The median intensive care unit stay was longer in the CPB group (18 vs. 11 days, p = 0.021). The CPB group showed an absence of perioperative stroke and a smaller number of events per patient-year for postoperative ischemic stroke (0.02 vs. 0.12, p = 0.003). 30-day survival (87% vs. 87.1%) and 1-year survival (80.3% vs. 74%) were similar in both groups (p = 0.78). CONCLUSION: Visual LV inspection on CPB may reduce the risk of postoperative ischemic stroke. Despite the negative effects of employing CPB in lieu of other intraoperative strategies, survival was similar in both groups.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Corazón Auxiliar , Adulto , Puente Cardiopulmonar , Oxigenación por Membrana Extracorpórea/métodos , Ventrículos Cardíacos , Corazón Auxiliar/efectos adversos , Humanos , Estudios Retrospectivos , Resultado del Tratamiento
15.
Thorac Cardiovasc Surg ; 70(6): 458-466, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35817063

RESUMEN

OBJECTIVES: Cardiac support systems are being used increasingly more due to the growing prevalence of heart failure and cardiogenic shock. Reducing cardiac afterload, intracardiac pressure, and flow support are important factors. Extracorporeal membrane oxygenation (ECMO) and intracardiac microaxial pump systems (Impella) as non-permanent MCS (mechanical circulatory support) are being used increasingly. METHODS: We reviewed the recent literature and developed an international European registry for non-permanent MCS. RESULTS: Life-threatening conditions that are observed preoperatively often include reduced left ventricular function, systemic hypoperfusion, myocardial infarction, acute and chronic heart failure, myocarditis, and valve vitia. Postoperative complications that are commonly observed include severe systemic inflammatory response, ischemia-reperfusion injury, trauma-related disorders, which ultimately may lead to low cardiac output (CO) syndrome and organ dysfunctions, which necessitates a prolonged ICU stay. Choosing the appropriate device for support is critical. The management strategies and complications differ by system. The "heart-team" approach is inevitably needed.However despite previous efforts to elucidate these topics, it remains largely unclear which patients benefit from certain systems, when is the right time to initiate (MCS), which support system is appropriate, what is the optimal level and type of support, which therapeutic additive and supportive strategies should be considered and ultimately, what are the future prospects and therapeutic developments. CONCLUSION: The European cardiac surgical register ImCarS has been established as an IIT with the overall aim to evaluate data received from the daily clinical practice in cardiac surgery. Interested colleagues are cordially invited to join the register. CLINICAL REGISTRATION NUMBER: DRKS00024560. POSITIVE ETHICS VOTE: AZ 246/20 Faculty of Medicine, Justus-Liebig-University-Gießen.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Insuficiencia Cardíaca , Corazón Auxiliar , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Corazón Auxiliar/efectos adversos , Humanos , Choque Cardiogénico/diagnóstico , Choque Cardiogénico/etiología , Choque Cardiogénico/terapia , Resultado del Tratamiento
16.
Echocardiography ; 39(5): 667-677, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35393693

RESUMEN

AIM: The aim of the study was to characterize the remodeling process in a large cohort of patients supported with a centrifugal left ventricular assist device (cfLVAD) by standardized serial echocardiography. METHODS AND RESULTS: From 3/2018 all cfLVAD patients underwent transthoracic echocardiography at 6 and 12 months after implantation using a standardized protocol. A total of 512 echocardiograms were reviewed (216 preoperative, 156 at 6 months, 140 at 12 months). While on cfLVAD support, left ventricular (LV) diameter decreased (p < .001). LV ejection fraction (LVEF) and LV fractional area change improved (p < .001). Potential for cfLVAD explantation (as defined by an LVEF ≥45% and opening of the aortic valve [AV]) was seen in nine patients at 6 and 21 patients at 12 months. The tricuspid annular excursion decreased significantly, while the right ventricular fractional area change did not change. Tricuspid regurgitation (TR) and mitral regurgitation (MR) improved significantly during LVAD support. Opening of the AV was seen in >64% of the patients at 6 months and in 66% at 12 months. Moderate aortic regurgitation (AR) was rare with 3.8% at 6 months but increased with the duration of cfLVAD support (8.5% at 12 months). We found no significant difference in echocardiographic parameters between patients supported with a HeartWare HVAD™ or a HeartMate 3™ device. CONCLUSION: LVAD therapy can lead to reverse LV remodeling and improvement of MR and TR. However, right ventricular function does not improve and prevalence of AR progressively increases during mechanical support.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Insuficiencia de la Válvula Mitral , Insuficiencia de la Válvula Tricúspide , Ecocardiografía , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/cirugía , Humanos , Estudios Retrospectivos , Resultado del Tratamiento , Remodelación Ventricular
17.
J Card Surg ; 37(4): 1114-1117, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35094449

RESUMEN

BACKGROUND: Severe tricuspid regurgitation is a known risk factor for right ventricular failure (RVF) after left ventricular assist device (LVAD) implantation and is often treated with concomitant tricuspid valve repair (TVR). The right atriotomy needed for exposure of the tricuspid valve may complicate early implantation of a durable right ventricular assist device, which may be needed if RVF persists. MATERIALS & METHODS: A 53-year-old male patient on Impella and extracorporeal life support was scheduled for LVAD implantation with concomitant TVR. RESULTS: We performed a technique for closure of the right atrium after TVR with a modified ventricular assist device ring to facilitate right ventricular support implantation if needed.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Insuficiencia de la Válvula Tricúspide , Disfunción Ventricular Derecha , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/cirugía , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/complicaciones , Disfunción Ventricular Derecha/complicaciones
18.
J Card Surg ; 36(10): 3905-3909, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34250624

RESUMEN

BACKGROUND: Systemic infections and chronic graft rejection represent common causes of mortality and morbidity in heart transplant patients. In severe cases, cardiogenic shock (CS) may occur and require hemodynamic stabilization with temporary mechanical circulatory support (tempMCS). Under these devastating circumstances, treatment of sequelae of left ventricular dysfunction, such as secondary mitral regurgitation (MR) is challenging, especially when surgical repair is deemed futile. In nontransplant patients, interventional mitral valve repair strategies such as the MitraClip system (Abbott Cardiovascular) have been used to successfully treat secondary MR and allow for weaning from tempMCS. CASE SUMMARY: We report about the first patient in whom profound CS after heart transplantation was stabilized with tempMCS followed by interventional elimination of secondary MR.


Asunto(s)
Trasplante de Corazón , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Catéteres , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/cirugía , Resultado del Tratamiento
19.
J Card Surg ; 36(11): 4141-4152, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34460968

RESUMEN

BACKGROUND AND METHODS: Microaxial left ventricular assist devices are used increasingly for treating cardiogenic shock. We compared the short-term outcome of patients supported with different microaxial devices for cardiogenic shock. A retrospective propensity score-adjusted analysis was performed in cardiogenic shock patients treated with either the Impella CP (n = 64) or the Impella 5.0/5.5 (n = 62) at two tertiary cardiac care centers between 1/14 and 12/19. RESULTS: Patients in the Impella CP group were significantly older (69.6 ± 10.7 vs. 58.7 ± 11.9 years, p = .001), more likely in INTERMACS profile 1 (76.6% vs. 50%, p = .003) and post-C-reactive protein (CPR) (36% vs. 13%, p = .006). The median support time was 2.0 days [0.0, 5.3] in the CP group vs. 8.5 days [4.3, 15.8] in the 5.0/5.5 group (p < .001). The unadjusted 30-day survival was significantly higher in the Impella 5.0/5.5 group (58% vs. 36%, p = .021, odds ratio [OR] for 30-day survival on Impella 5.0/5.5 was 3.68 [95% confidence interval [CI]: [1.46-9.90]], p = .0072). After adjustment, the 30-day survival was similar for both devices (OR: 1.23, 95% CI: [0.34-4.18], p = .744). Lactate levels above 8 mmol/L and preoperative CPR were associated with a significant mortality increase in both cohorts (OR: 10.7, 95% CI: [3.45-47.34], p < .001; OR: 13.2, 95% CI: [4.28-57.89], p < .001, respectively). CONCLUSION: Both Impella devices offer a similar effect with regard to survival in cardiogenic shock patients. Preoperative CPR or lactate levels exceeding 8 mmol/L immediately before implantation have a poor prognosis on Impella CP and Impella 5.0/5.5.


Asunto(s)
Corazón Auxiliar , Choque Cardiogénico , Humanos , Puntaje de Propensión , Estudios Retrospectivos , Choque Cardiogénico/terapia , Resultado del Tratamiento
20.
J Card Surg ; 36(8): 2651-2657, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33960521

RESUMEN

OBJECTIVES: Peripartum cardiomyopathy (PPCM) is a form of systolic heart failure occurring toward the end of pregnancy or in the period after delivery. Lack of myocardial recovery or therapy-refractory cardiogenic shock are rare complications and left ventricular assist device (LVAD) systems might be used as a life-saving option. The aim of this study was to investigate outcomes of PPCM patients supported with LVAD, registered in the European Registry for Patients with Mechanical Circulatory Support (EUROMACS). METHODS: All patients registered in EUROMACS with a primary diagnosis of PPCM were included in this study. Demographic, preoperative, intraoperative, postoperative, and follow-up data were collected and patients analysed concerning their outcome after initiation of LVAD therapy. RESULTS: Between May 2011 and September 2018, 16 patients with PPCM and consecutive LVAD implantation were enrolled into EUROMACS. The median age of the patient population was 31 (26;41) years with a mean left ventricular ejection fraction (LV-EF) of 15% ± 6%. In-hospital mortality after LVAD implantation was 6% (n = 1). One-year mortality accounted for 13% (n = 2). Six patients (40%) were transplanted with a median support time of 769 (193;1529) days. Weaning of LVAD support due to ventricular recovery was feasible in 3 (20%) patients. CONCLUSION: In patients with severe PPCM, LVAD therapy is associated with considerably low in-hospital mortality, potentially allowing bridging to heart transplantation, or left ventricular recovery. Therefore, durable mechanical support should be considered as a treatment option in this, by nature, young and often otherwise healthy patient population.


Asunto(s)
Cardiomiopatías , Insuficiencia Cardíaca , Corazón Auxiliar , Adulto , Cardiomiopatías/complicaciones , Cardiomiopatías/terapia , Femenino , Humanos , Periodo Periparto , Embarazo , Estudios Retrospectivos , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA