Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
J Synchrotron Radiat ; 27(Pt 5): 1438-1446, 2020 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-32876621

RESUMEN

B21 is a small-angle X-ray scattering (SAXS) beamline with a bending magnet source in the 3 GeV storage ring at the Diamond Light Source Ltd synchrotron in the UK. The beamline utilizes a double multi-layer monochromator and a toroidal focusing optic to deliver 2 × 1012 photons per second to a 34 × 40 µm (FWHM) focal spot at the in-vacuum Eiger 4M (Dectris) detector. A high-performance liquid chromatography system and a liquid-handling robot make it possible to load solution samples into a temperature-controlled in-vacuum sample cell with a high level of automation. Alternatively, a range of viscous or solid materials may be loaded manually using a range of custom sample cells. A default scattering vector range from 0.0026 to 0.34 Å-1 and low instrument background make B21 convenient for measuring a wide range of biological macromolecules. The beamline has run a full user programme since 2013.

2.
J Synchrotron Radiat ; 26(Pt 1): 253-262, 2019 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-30655493

RESUMEN

Systematic studies of the performance of a water-cooled X-ray monochromator, designed and built for the B16 Test beamline at the Diamond Light Source, UK, are presented. A technical description of the monochromator is given and the results of commissioning measurements are discussed. Overall, the monochromator satisfies the original specifications well and meets all the major requirements of the versatile beamline. Following its successful implementation on B16, the basic monochromator design has been reproduced and adapted on other Diamond Light Source beamlines, including B18 and B21.

3.
J Synchrotron Radiat ; 26(Pt 1): 291-301, 2019 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-30655497

RESUMEN

VMXi is a new high-flux microfocus macromolecular crystallography beamline at Diamond Light Source. The beamline, dedicated to fully automated and fully remote data collection of macromolecular crystals in situ, allows rapid screening of hundreds of crystallization plates from multiple user groups. Its main purpose is to give fast feedback at the complex stages of crystallization and crystal optimization, but it also enables data collection of small and delicate samples that are particularly difficult to harvest using conventional cryo-methods, crystals grown in the lipidic cubic phase, and allows for multi-crystal data collections in drug discovery programs. The beamline is equipped with two monochromators: one with a narrow band-pass and fine energy resolution (optimal for regular oscillation experiments), and one with a wide band-pass and a high photon flux (optimal for fast screening). The beamline has a state-of-the-art detector and custom goniometry that allows fast data collection. This paper describes the beamline design, current status and future plans.

4.
J Appl Crystallogr ; 54(Pt 5): 1349-1359, 2021 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-34667446

RESUMEN

With the recent increase in research into ferroelectric, anti-ferroelectric and piezoelectric materials, studying the solid-state properties in situ under applied electric fields is vital in understanding the underlying processes. Where this behaviour is the result of atomic displacements, crystallographic insight has an important role. This work presents a sample environment designed to apply an electric field to single-crystal samples in situ on the small-molecule single-crystal diffraction beamline I19, Diamond Light Source (UK). The configuration and operation of the cell is described as well as its application to studies of a proton-transfer colour-change material.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA