Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Catheter Cardiovasc Interv ; 97(7): E1019-E1024, 2021 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-33417282

RESUMEN

BACKGROUND: In this analysis of the EWOLUTION registry, we evaluated the incidence, relevance and predictors of device-related thrombus in a large multi-center real-world cohort undergoing LAAc with the WATCHMAN device. METHODS AND RESULTS: We analyzed the 835 patients who underwent percutaneous LAA closure with the WATCHMAN device in the EWOLUTION registry in whom at least one TEE follow up was performed. Patients were 74 ± 9 y/o and were at high risk for stroke and bleeding (CHA2DS2-VASC-Score 4.3 ± 1.7; HAS-BLED-Score 2.3 ± 1.2). Device-related thrombus was detected in 4.1% (34/835) after a median of 54 days (IQR 42-111 days) with 91.2% (31/34) being detected within 3 months after the procedure or at the time of first TEE. Hereby DRT occurred irrespective of postprocedural anticoagulation. Patients with DRT more frequently had long-standing, non-paroxysmal atrial fibrillation (82.4 vs. 64.9%, p < .01), evidence of dense spontaneous echo contrast (26.5 vs. 11.9%, p = .03) and larger LAA diameters at the ostium (22.8 ± 3.5 vs. 21.1 ± 3.5 mm, p < .01) compared to patients without DRT. Left ventricular ejection fraction, device compression ratio and the incidence of renal dysfunction did not differ between the two groups. In a multivariate analysis, only non-paroxysmal atrial fibrillation identified as an independent predictor of developing DRT. Specific treatment of DRT was initiated in 62% (21/34) of patients whereas resolution was confirmed in 86% (18/21) of cases. Overall, no significant differences in annual rates of stroke/TIA or systemic embolism were observed in patients with or without DRT (DRT 1.7 vs. No-DRT 2.2%/year, p = .8). CONCLUSIONS: In real-world patients undergoing LAAc with the WATCHMAN device, DRT is rare. DRT was most frequently detected within the first 3 months after LAAc regardless of post-procedural regimen and was not associated with an increased risk of stroke or SE. While long-standing atrial fibrillation was the only independent factor associated with DRT, medical treatment of DRT resulted in a resolution of thrombi in most cases.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular , Trombosis , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/epidemiología , Humanos , Incidencia , Sistema de Registros , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Volumen Sistólico , Trombosis/diagnóstico por imagen , Trombosis/epidemiología , Trombosis/etiología , Resultado del Tratamiento , Función Ventricular Izquierda
2.
JAMA Cardiol ; 8(11): 1013-1021, 2023 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-37703036

RESUMEN

Importance: Even after fractional flow reserve (FFR)-guided complete revascularization, patients with myocardial infarction (MI) have high rates of recurrent major adverse cardiovascular events (MACE). These recurrences may be caused by FFR-negative high-risk nonculprit lesions. Objective: To assess the association between optical coherence tomography (OCT)-identified high-risk plaques of FFR-negative nonculprit lesions and occurrence of MACE in patients with MI. Design, Setting, and Participants: PECTUS-obs (Identification of Risk Factors for Acute Coronary Events by OCT After STEMI [ST-segment elevation MI] and NSTEMI [non-STEMI] in Patients With Residual Non-flow Limiting Lesions) is an international, multicenter, prospective, observational cohort study. In patients presenting with MI, OCT was performed on all FFR-negative (FFR > 0.80) nonculprit lesions. A high-risk plaque was defined containing at least 2 of the following prespecified criteria: (1) a lipid arc at least 90°, (2) a fibrous cap thickness less than 65 µm, and (3) either plaque rupture or thrombus presence. Patients were enrolled from December 14, 2018, to September 15, 2020. Data were analyzed from December 2, 2022, to June 28, 2023. Main Outcome and Measure: The primary end point of MACE, a composite of all-cause mortality, nonfatal MI, or unplanned revascularization, at 2-year follow-up was compared in patients with and without a high-risk plaque. Results: A total of 438 patients were enrolled, and OCT findings were analyzable in 420. Among included patients, mean (SD) age was 63 (10) years, 340 (81.0) were men, and STEMI and non-STEMI were equally represented (217 [51.7%] and 203 [48.3%]). A mean (SD) of 1.17 (0.42) nonculprit lesions per patient was imaged. Analysis of OCT images revealed at least 1 high-risk plaque in 143 patients (34.0%). The primary end point occurred in 22 patients (15.4%) with a high-risk plaque and 23 of 277 patients (8.3%) without a high-risk plaque (hazard ratio, 1.93 [95% CI, 1.08-3.47]; P = .02), primarily driven by more unplanned revascularizations in patients with a high-risk plaque (14 of 143 [9.8%] vs 12 of 277 [4.3%]; P = .02). Conclusions and Relevance: Among patients with MI and FFR-negative nonculprit lesions, the presence of a high-risk plaque is associated with a worse clinical outcome, which is mainly driven by a higher number of unplanned revascularizations. In a population with a high recurrent event rate despite physiology-guided complete revascularization, these results call for research on additional pharmacological or focal treatment strategies in patients harboring high-risk plaques.


Asunto(s)
Reserva del Flujo Fraccional Miocárdico , Infarto del Miocardio , Intervención Coronaria Percutánea , Placa Aterosclerótica , Infarto del Miocardio con Elevación del ST , Masculino , Humanos , Persona de Mediana Edad , Femenino , Infarto del Miocardio con Elevación del ST/terapia , Estudios Prospectivos , Intervención Coronaria Percutánea/métodos , Infarto del Miocardio/epidemiología , Placa Aterosclerótica/diagnóstico por imagen
3.
BMJ Open ; 11(7): e048994, 2021 07 07.
Artículo en Inglés | MEDLINE | ID: mdl-34233996

RESUMEN

INTRODUCTION: In patients with myocardial infarction, the decision to treat a nonculprit lesion is generally based on its physiological significance. However, deferral of revascularisation based on nonischaemic fractional flow reserve (FFR) values in these patients results in less favourable outcomes compared with patients with stable coronary artery disease, potentially caused by vulnerable nonculprit lesions. Intravascular optical coherence tomography (OCT) imaging allows for in vivo morphological assessment of plaque 'vulnerability' and might aid in the detection of FFR-negative lesions at high risk for recurrent events. METHODS AND ANALYSIS: The PECTUS-obs study is an international multicentre prospective observational study that aims to relate OCT-derived vulnerable plaque characteristics of nonflow limiting, nonculprit lesions to clinical outcome in patients with myocardial infarction. A total of 438 patients presenting with myocardial infarction (ST-elevation myocardial infarction and non-ST-elevation myocardial infarction) will undergo OCT-imaging of any FFR-negative nonculprit lesion for detection of plaque vulnerability. The primary study endpoint is a composite of major adverse cardiovascular events (all-cause mortality, nonfatal myocardial infarction or unplanned revascularisation) at 2-year follow-up. Secondary endpoints will be the same composite at 1-year and 5-year follow-up, target vessel failure, target vessel revascularisation, target lesion failure and target lesion revascularisation. ETHICS AND DISSEMINATION: This study has been approved by the Medical Ethics Committee of the region Arnhem-Nijmegen. The results of this study will be disseminated in a main paper and additional papers with subgroup analyses. TRIAL REGISTRATION NUMBER: NCT03857971.


Asunto(s)
Reserva del Flujo Fraccional Miocárdico , Infarto del Miocardio , Intervención Coronaria Percutánea , Angiografía Coronaria , Humanos , Infarto del Miocardio/diagnóstico por imagen , Estudios Prospectivos , Factores de Riesgo , Tomografía de Coherencia Óptica , Resultado del Tratamiento
4.
EuroIntervention ; 13(17): 2003-2011, 2018 04 20.
Artículo en Inglés | MEDLINE | ID: mdl-29313819

RESUMEN

AIMS: The study aimed to confirm the efficacy and safety of WATCHMAN LAA closure in atrial fibrillation patients unsuitable for oral anticoagulation. METHODS AND RESULTS: The EWOLUTION registry prospectively collects all clinical data on 1,005 European patients implanted with a WATCHMAN device. Following the procedure, 605 patients (60.2%) received dual antiplatelet therapy according to the local standard; DAPT was discontinued in 85% of patients within one year. CHA2DS2-VASc and HAS-BLED scores were 4.61.6 and 2.41.2, respectively. The periprocedural SAE rate was 3.3% (2.0% major adverse cardiac events), mostly resolving without sequelae. Device embolisation or pericardial effusion occurred in one (0.2%) and two (0.3%) patients, respectively. TEE (median 62 days post implant, IQR: 47-97) confirmed effective sealing (no leak >5 mm) in 99.2% of patients. Device thrombus was present in 22 patients (4.0%), one patient developed a stroke. One-year mortality in the DAPT group was 9.6% (N=58) reflecting the advanced age and comorbidities in this population. The ischaemic stroke rate at one year was 1.4% (expected based on CHA2DS2-VASc: 7.5%), none fatal. The major bleeding rate was 2.5%, or 2.1% excluding periprocedural events (expected rate on VKA based on HAS-BLED: 5.1%). CONCLUSIONS: LAA closure with the WATCHMAN device followed by DAPT therapy in a high-risk patient population is safe. At one year, the intervention is associated with a substantial risk reduction regarding ischaemic stroke and major bleeding compared to the expected rate based on CHA2DS2-VASc and HAS-BLED scores.


Asunto(s)
Apéndice Atrial/cirugía , Fibrilación Atrial , Hemorragia , Inhibidores de Agregación Plaquetaria , Complicaciones Posoperatorias , Implantación de Prótesis , Dispositivo Oclusor Septal , Accidente Cerebrovascular , Anciano , Fibrilación Atrial/complicaciones , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/cirugía , Quimioterapia Combinada/métodos , Europa (Continente) , Femenino , Atrios Cardíacos , Hemorragia/inducido químicamente , Hemorragia/prevención & control , Humanos , Masculino , Persona de Mediana Edad , Evaluación de Procesos y Resultados en Atención de Salud , Inhibidores de Agregación Plaquetaria/administración & dosificación , Inhibidores de Agregación Plaquetaria/efectos adversos , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/epidemiología , Implantación de Prótesis/efectos adversos , Implantación de Prótesis/métodos , Implantación de Prótesis/estadística & datos numéricos , Sistema de Registros , Ajuste de Riesgo/métodos , Dispositivo Oclusor Septal/efectos adversos , Dispositivo Oclusor Septal/estadística & datos numéricos , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA