Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Cardiovasc Interv Ther ; 32(1): 36-47, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27139179

RESUMEN

In a European consortium, a decellularized tissue-engineered heart valve (dTEHV) based on vessel-derived cells, a fast-degrading scaffold and a self-expanding stent has been developed. The aim of this study was to demonstrate that percutaneous delivery is feasible. To implant this valve prosthesis transcutaneously into pulmonary position, a catheter delivery system was designed and custom made. Three sheep underwent transjugular prototype implantation. Intracardiac echocardiography (ICE), angiography and computed tomography (CT) were applied to assess the position, morphology, function and dimensions of the stented dTEHV. One animal was killed 3 h after implantation and two animals were followed up for 12 weeks. Explanted valves were analyzed macroscopically and microscopically. In all animals, the percutaneous implantation of the stented dTEHV was successful. The prototype delivery system worked at first attempt in all animals. In the first implantation a 22 F system was used: the valve was slightly damaged during crimping. Loading was difficult due to valve-catheter mismatch in volume. In the second and third implantation a 26 F system was used: the valves fitted adequately and stayed intact. Following implantation, these two valves showed moderate regurgitation due to insufficient coaptation. During follow-up, regurgitation increased due to shortened leaflets. At explantation, macroscopic and microscopic analysis confirmed the second and third valve to be intact. Histology revealed autologous recellularization of the decellularized valve after 12 weeks in vivo. It was demonstrated that completely in vitro tissue-engineered heart valves are thin and stable enough to be crimped and implanted transvenously into pulmonary position.


Asunto(s)
Enfermedades de las Válvulas Cardíacas/cirugía , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Válvula Pulmonar/cirugía , Ingeniería de Tejidos , Angiografía , Animales , Modelos Animales de Enfermedad , Ecocardiografía , Diseño de Equipo , Estudios de Factibilidad , Enfermedades de las Válvulas Cardíacas/diagnóstico , Diseño de Prótesis , Válvula Pulmonar/diagnóstico por imagen , Ovinos , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA