Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
Chem Soc Rev ; 51(6): 1899-1925, 2022 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-35246673

RESUMEN

Machine learning (ML) is becoming an effective tool for studying 2D materials. Taking as input computed or experimental materials data, ML algorithms predict the structural, electronic, mechanical, and chemical properties of 2D materials that have yet to be discovered. Such predictions expand investigations on how to synthesize 2D materials and use them in various applications, as well as greatly reduce the time and cost to discover and understand 2D materials. This tutorial review focuses on the understanding, discovery, and synthesis of 2D materials enabled by or benefiting from various ML techniques. We introduce the most recent efforts to adopt ML in various fields of study regarding 2D materials and provide an outlook for future research opportunities. The adoption of ML is anticipated to accelerate and transform the study of 2D materials and their heterostructures.


Asunto(s)
Electrónica , Aprendizaje Automático , Algoritmos
2.
Phys Chem Chem Phys ; 23(3): 2377-2383, 2021 Jan 28.
Artículo en Inglés | MEDLINE | ID: mdl-33458732

RESUMEN

Hydrogen detection devices based on gold-tin oxide/reduced graphene oxide (Au-SnO2/rGO) nanohybrids were fabricated by combining a hydrothermal method with sputter coating. The gas sensing performance of the Au-SnO2/rGO sensor was investigated under different concentrations of hydrogen from 0.04% to 1% at room temperature, which indicated a notable sensitive response even for 0.04% hydrogen. The activation energies of hydrogen adsorption/desorption were extracted via Arrhenius analysis which revealed the acceleration effect of gold dopants. This acceleration led to a faster response and recovery during hydrogen sensing. The activation energy analysis provided a more comprehensive understanding on the gas sensing mechanism. A hydrogen detection handheld device is demonstrated by integrating the sensor chip with a portable digital meter for direct readout of test results.

3.
Anal Chem ; 90(24): 14230-14238, 2018 12 18.
Artículo en Inglés | MEDLINE | ID: mdl-30398847

RESUMEN

Recent outbreaks of Ebola-virus infections in several countries demand a rapid point-of-care (POC)-detection strategy. This paper reports on an innovative pathway founded on electronic-resonance-frequency modulation to detect Ebola glycoprotein (GP), on the basis of a carrier-injection-trapping-release-transfer mechanism and the standard antibody-antigen-interaction principle within a dielectric-gated reduced graphene oxide (rGO) field-effect transistor (GFET). The sensitivity of Ebola detection can be significantly enhanced by monitoring the device's electronic-resonance frequency, such as its inflection frequency ( fi), where the phase angle reaches a maximum (θmax). In addition to excellent selectivity, a sensitivity of ∼36-160% and ∼17-40% for 0.001-3.401 mg/L Ebola GP can be achieved at high and low inflection-resonance frequencies, respectively, which are several orders of magnitude higher than the sensitivity from other electronic parameters (e.g., resistance-based sensitivity). Using equivalent circuit modeling for contributions from channel and contact, analytical equations for resonance shifts have been generalized. When matching with the incoming ac-measurement signal, electronic resonance from the phase-angle spectrum evolves from various relaxation processes (e.g., trap and release of injected charges at surface-trap sites of the channel-gate oxide and channel-source or drain interfaces) that are associated with a characteristic emission frequency. Using charge-relaxation dynamics, a high-performance bio-FET sensing platform for healthcare and bioelectronic applications is realized through resonance shifting.


Asunto(s)
Ebolavirus/metabolismo , Grafito/química , Sistemas de Atención de Punto , Transistores Electrónicos , Proteínas Virales/inmunología , Anticuerpos Inmovilizados/química , Anticuerpos Inmovilizados/inmunología , Anticuerpos Antivirales/química , Anticuerpos Antivirales/inmunología , Reacciones Antígeno-Anticuerpo , Oro/química , Fiebre Hemorrágica Ebola/diagnóstico , Humanos , Nanopartículas del Metal/química , Proteínas Recombinantes/biosíntesis , Proteínas Recombinantes/inmunología , Proteínas Recombinantes/aislamiento & purificación , Resonancia por Plasmón de Superficie , Proteínas Virales/genética , Proteínas Virales/metabolismo
4.
Nanotechnology ; 29(37): 375501, 2018 Sep 14.
Artículo en Inglés | MEDLINE | ID: mdl-29974868

RESUMEN

Stimuli-responsive field-effect transistors (FETs) based on 2D nanomaterials have been considered as attractive candidates for sensing applications due to their rapid response, high sensitivity, and real-time monitoring capabilities. Here we report on an impedance spectroscopy technique for FET sensor applications with ultra-high sensitivity and good reproducibility. An alumina-gated FET, using an ultra-thin black phosphorus flake as the channel material, shows significantly improved stability and ultra-high sensitivity to lead ions in water. In addition, the phase angle in the low frequency region was found to change significantly in the presence of lead ion solutions, whereas it was almost unchanged in the high frequency region. The dominant sensing performance was found at low frequency phase spectrum around 50 Hz and a systematic change in the phase angle in different lead ion concentrations was found. Applying the impedance spectroscopy technique to insulator-gated FET sensors could open a new avenue for real-world sensor applications.

5.
Chem Soc Rev ; 46(22): 6872-6904, 2017 Nov 13.
Artículo en Inglés | MEDLINE | ID: mdl-28933459

RESUMEN

Meeting the increasing demand for sensors with high sensitivity, high selectivity, and rapid detection presents many challenges. In the last decade, electronic sensors based on field-effect transistors (FETs) have been widely studied due to their high sensitivity, rapid detection, and simple test procedure. Among these sensors, two-dimensional (2D) nanomaterial-based FET sensors have been demonstrated with tremendous potential for the detection of a wide range of analytes which is attributed to the unique structural and electronic properties of 2D nanomaterials. This comprehensive review discusses the recent progress in graphene-, 2D transition metal dichalcogenide-, and 2D black phosphorus-based FET sensors, with an emphasis on rapid and low-concentration detection of gases, biomolecules, and water contaminants.


Asunto(s)
Técnicas Biosensibles/instrumentación , Diseño de Equipo/instrumentación , Grafito/química , Nanoestructuras/química , Transistores Electrónicos , Conductometría/métodos , Humanos , Nanotecnología/métodos , Fenómenos Físicos
6.
Anal Chem ; 86(15): 7516-22, 2014 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-24992696

RESUMEN

Herein, we report on a facile, low-cost, and efficient method to tune the structure and properties of chemically reduced graphene oxide (rGO) by applying a transient voltage across the rGO for ultrasensitive gas sensors. A large number of defects, including pits, are formed in the rGO upon the voltage activation. More interestingly, the number of epoxide and ether functional groups in the rGO increased after the voltage activation. The voltage-activated rGO was highly sensitive to NO2 with a sensitivity 500% higher than that of the original rGO. The lower detection limit can reach an unprecedented ultralow concentration of 50 ppb for NO2 sensing. Density functional theory (DFT) calculations revealed that the high sensitivity to NO2 is attributed to the efficient charge transfer from ether groups to NO2, which is the dominant sensing mechanism. This study points to a promising method to tune the properties of graphene-based materials through the creation of additional defects and functional groups for high-performance gas sensors.

7.
ACS Appl Mater Interfaces ; 16(21): 27961-27968, 2024 May 29.
Artículo en Inglés | MEDLINE | ID: mdl-38749768

RESUMEN

Two-dimensional nanomaterials such as reduced graphene oxide (rGO) have captured significant attention in the realm of field-effect transistor (FET) sensors due to their inherent high sensitivity and cost-effective manufacturing. Despite their attraction, a comprehensive understanding of rGO-solution interfaces (specifically, electrochemical interfacial properties influenced by linker molecules and surface chemistry) remains challenging, given the limited capability of analytical tools to directly measure intricate solution interface properties. In this study, we introduce an analytical tool designed to directly measure the surface charge density of the rGO-solution interface leveraging the remote floating-gate FET (RFGFET) platform. Our methodology involves characterizing the electrochemical properties of rGO, which are influenced by adhesion layers between SiO2 and rGO, such as (3-aminopropyl)trimethoxysilane (APTMS) and hexamethyldisilazane (HMDS). The hydrophilic nature of APTMS facilitates the acceptance of oxygen-rich rGO, resulting in a noteworthy pH sensitivity of 56.8 mV/pH at the rGO-solution interface. Conversely, hydrophobic HMDS significantly suppresses the pH sensitivity from the rGO-solution interface, attributed to the graphitic carbon-rich surface of rGO. Consequently, the carbon-rich surface facilitates a denser arrangement of 1-pyrenebutyric acid N-hydroxysuccinimide ester linkers for functionalizing capturing probes on rGO, resulting in an enhanced sensitivity of lead ions by 32% in our proof-of-concept test.

8.
ACS Appl Mater Interfaces ; 15(12): 15195-15202, 2023 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-36938607

RESUMEN

Rapid diagnosis of coronavirus disease 2019 (COVID-19) is key for the long-term control of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) amid renewed threats of mutated SARS-CoV-2 around the world. Here, we report on an electrical label-free detection of SARS-CoV-2 in nasopharyngeal swab samples directly collected from outpatients or in saliva-relevant conditions by using a remote floating-gate field-effect transistor (RFGFET) with a 2-dimensional reduced graphene oxide (rGO) sensing membrane. RFGFET sensors demonstrate rapid detection (<5 min), a 90.6% accuracy from 8 nasal swab samples measured by 4 different devices for each sample, and a coefficient of variation (CV) < 6%. Also, RFGFET sensors display a limit of detection (LOD) of pseudo-SARS-CoV-2 that is 10 000-fold lower than enzyme-linked immunosorbent assays, with a comparable LOD to that of reverse transcription-polymerase chain reaction (RT-PCR) for patient samples. To achieve this, comprehensive systematic studies were performed regarding interactions between SARS-CoV-2 and spike proteins, neutralizing antibodies, and angiotensin-converting enzyme 2, as either a biomarker (detection target) or a sensing probe (receptor) functionalized on the rGO sensing membrane. Taken together, this work may have an immense effect on positioning FET bioelectronics for rapid SARS-CoV-2 diagnostics.


Asunto(s)
COVID-19 , Grafito , Humanos , SARS-CoV-2 , COVID-19/diagnóstico , Prueba de COVID-19 , Saliva
9.
Nat Commun ; 14(1): 4184, 2023 Jul 13.
Artículo en Inglés | MEDLINE | ID: mdl-37443127

RESUMEN

Risk management for drinking water often requires continuous monitoring of various toxins in flowing water. While they can be readily integrated with existing water infrastructure, two-dimensional (2D) electronic sensors often suffer from device-to-device variations due to the lack of an effective strategy for identifying faulty devices from preselected uniform devices based on electronic properties alone, resulting in sensor inaccuracy and thus slowing down their real-world applications. Here, we report the combination of wet transfer, impedance and noise measurements, and machine learning to facilitate the scalable nanofabrication of graphene-based field-effect transistor (GFET) sensor arrays and the efficient identification of faulty devices. Our sensors were able to perform real-time detection of heavy-metal ions (lead and mercury) and E. coli bacteria simultaneously in flowing tap water. This study offers a reliable quality control protocol to increase the potential of electronic sensors for monitoring pollutants in flowing water.


Asunto(s)
Agua Potable , Grafito , Mercurio , Metales Pesados , Contaminantes del Agua , Grafito/química , Escherichia coli , Agua Potable/análisis
10.
Adv Mater ; 34(3): e2106975, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34921575

RESUMEN

Over the last decade, 2D layered nanomaterials have attracted significant attention across the scientific community due to their rich and exotic properties. Various nanoelectronic devices based on these 2D nanomaterials have been explored and demonstrated, including those for environmental applications. Here, the fundamental attributes of 2D layered nanomaterials for field-effect transistor (FET) sensors and tunneling FET (TFET) sensors, which provide versatile detection of water contaminants such as heavy-metal ions, bacteria, nutrients, and organic pollutants, are discussed. The major challenges and opportunities are also outlined for designing and fabricating 2D nanomaterial FET/TFET sensors with superior performance. Translation of these FET/TFET sensors from fundamental research to applied technology is illustrated through a case study on graphene-based real-time FET water sensors. A second case study centers on large-scale sensor networks for water-quality monitoring to enable intelligent drinking water and river-water systems. Overall, 2D nanomaterial FET sensors have significant potential for enabling a human-centered intelligent water system that can likely be applied to other precarious water supplies around the globe.

11.
ACS Appl Mater Interfaces ; 14(21): 24187-24196, 2022 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-35593886

RESUMEN

Despite intensive research of nanomaterials-based field-effect transistors (FETs) as a rapid diagnostic tool, it remains to be seen for FET sensors to be used for clinical applications due to a lack of stability, reliability, reproducibility, and scalability for mass production. Herein, we propose a remote floating-gate (RFG) FET configuration to eliminate device-to-device variations of two-dimensional reduced graphene oxide (rGO) sensing surfaces and most of the instability at the solution interface. Also, critical mechanistic factors behind the electrochemical instability of rGO such as severe drift and hysteresis were identified through extensive studies on rGO-solution interfaces varied by rGO thickness, coverage, and reduction temperature. rGO surfaces in our RFGFET structure displayed a Nernstian response of 54 mV/pH (from pH 2 to 11) with a 90% yield (9 samples out of total 10), coefficient of variation (CV) < 3%, and a low drift rate of 2%, all of which were calculated from the absolute measurement values. As proof-of-concept, we demonstrated highly reliable, reproducible, and label-free detection of spike proteins of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in a saliva-relevant media with concentrations ranging from 500 fg/mL to 5 µg/mL, with an R2 value of 0.984 and CV < 3%, and a guaranteed limit of detection at a few pg/mL. Taken together, this new platform may have an immense effect on positioning FET bioelectronics in a clinical setting for detecting SARS-CoV-2.


Asunto(s)
Técnicas Biosensibles , COVID-19 , Grafito , COVID-19/diagnóstico , Grafito/química , Humanos , Reproducibilidad de los Resultados , SARS-CoV-2 , Glicoproteína de la Espiga del Coronavirus , Transistores Electrónicos
12.
Appl Opt ; 50(7): 1007-13, 2011 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-21364724

RESUMEN

In a transmittance spectrum of air etalon composed of ITO-coated glass plates, stronger spectral modulation is observed by using a focused white-light incident beam compared with that by using a conventionally collimated beam. The light source is a single commercial light-emitting diode. An angular integrated multiple-beam Fabry-Perot model is proposed that is well fitted to the measured transmittance spectra. The gap thickness of the air etalon is sensitively retrieved and mapped at a lateral surface resolution of about 1 mm, and the unparallelness of the etalon angled as low as several microradians is thereafter estimated.

13.
ACS ES T Water ; 1(6): 1352-1362, 2021 Jun 11.
Artículo en Inglés | MEDLINE | ID: mdl-37566353

RESUMEN

SARS-CoV-2 is shed by COVID-19 patients and can be detected in wastewater. Thus, testing wastewater for the virus provides a depiction of disease prevalence in a community. Virus concentration data can be utilized to monitor infection trends, identify hot spots, and inform decision makers regarding reopening efforts and directing resources. This perspective aims to shed light on the current situation relating to SARS-CoV-2 in the wastewater system and the opportunity to utilize wastewater to collect useful epidemiological data. First, the survivability of SARS-CoV-2 in different water matrices is examined through the lens of surrogate viruses. Second, the effect of wastewater treatment processes on SARS-CoV-2 is investigated. Current standards for sufficient reduction of the virus and the risk of exposure that arises at each stage in the wastewater treatment process are discussed. Third, the immense potential of wastewater-based epidemiology (WBE) for managing the ongoing COVID-19 pandemic is analyzed. Studies that have tested wastewater or sludge for SARS-CoV-2 are discussed, and results are tabulated. Lastly, the current limitations of WBE and opportunities of future research are explored. Using the wealth of knowledge that the scientific community now has about WBE, wastewater testing should be considered by regional governments and private institutions.

14.
Nanoscale ; 12(3): 1500-1512, 2020 Jan 23.
Artículo en Inglés | MEDLINE | ID: mdl-31859311

RESUMEN

Atomically thin black phosphorus (BP) field-effect transistors have excellent potential for sensing applications. However, commercial scaling of PFET sensors is still in the early stage due to various technical challenges, such as tedious fabrication, low response% caused by rapid oxidation, non-ideal response output (spike/bidirectional), and large device variation due to poor control over layer thickness among devices. Attempts have been made to address these issues. First, a theoretical model for response% dependence on the number of layers is developed to show the role of atomically thin BP for better responses. A position-tracked, selected-area-exfoliation method has been developed to rapidly produce thin BP layers with a narrow distribution (∼1-7 layers), which can harness excellent gate control over the PFET channel. The typical current on/off ratio is in the range of ∼300-500. The cysteine-modified Al2O3-gated PFET sensors show high responses (∼30-900%) toward a wide detection range (∼1-400 ppb) of lead ions in water with a typical response time of ∼10-30 s. A strategy to minimize device variation is proposed by correlating PFETs' on/off ratio with sensitivity parameters. The thickness variation of the gate oxide is investigated to explain non-ideal and ideal response transient kinetics.

15.
Biosens Bioelectron ; 126: 664-671, 2019 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-30530212

RESUMEN

Antibiotic residue, as emerging pollution resulting from antibiotic abuse, poses a serious threat on ecosystem and human health. Conventional methods for antibiotic detection, e.g., liquid/gas chromatography, are based on complicated instruments and time-consuming; therefore, efforts have been made to realize in situ and real-time monitoring of antibiotics. Here, a miniaturized and integratable electronic antibiotic sensor based on field-effect transistor (FET) is reported. The reduced graphene oxide (rGO) nanosheet is used as the channel material and the aptamer RNA for tobramycin is modified onto rGO as the probe. A novel sensor design with 6-mercapto-1-hexanol (MCH)/1-pyrenebutanol (PBA) blocking layer (BL) for structure optimization is applied to enhance the sensor reliability and specificity. This rGO/aptamer/BL sensor shows an ultra-sensitivity to tobramycin with a lower detection limit of 0.3 nM and a quick response within 5 s, as well as a high specificity over other antibiotics such as kanamycin, streptomycin, ciprofloxacin, and tetracycline. The sensing mechanism based on the deformation of the charged aptamer probe is proposed via an in-depth analysis of the interactions between aptamer, tobramycin and rGO. In addition, sensing test performed under controlled microfluidic flow conditions demonstrates a great potential of the sensors in practical applications.


Asunto(s)
Antibacterianos/aislamiento & purificación , Aptámeros de Nucleótidos/química , Técnicas Biosensibles , Tobramicina/aislamiento & purificación , Antibacterianos/química , Grafito/química , Humanos , Kanamicina/química , Kanamicina/aislamiento & purificación , Tobramicina/química , Transistores Electrónicos
16.
ACS Appl Mater Interfaces ; 10(31): 26170-26177, 2018 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-29995381

RESUMEN

Benefiting from the reversible conversion reaction upon delithiation, nanosized SnO2, with its theoretical capacity of 1494 mA h g-1, has gained special attention as a promising anode material. Here, we report a self-assembled SnO2/Sn-reduced graphene oxide (rGO) sandwich nanocomposite developed by organometallic precursor coating and in situ transformation. Ultrafine SnO2 nanoparticles with an average diameter of 5 nm are sandwiched within the rGO/carbonaceous network, which not only greatly alleviates the volume changes upon lithiation and aggregation of SnO2 nanoparticles but also facilitates the charge transfer and reaction kinetics of SnO2 upon lithiation/delithiation. As a result, the SnO2/Sn-rGO nanocomposite exhibited a superior lithium storage capacity with a reversible capacity of 1307 mA h g-1 at a current density of 80 mA g-1 in the potential window of 0.01-2.5 V versus Li+/Li and showed a reversible capacity of 767 mA h g-1 over 200 cycles at a current density of 400 mA g-1. When cycling at a higher current density of 1600 mA g-1, the SnO2/Sn-rGO nanocomposite showed a highly stable capacity of 449 mA g-1 without obvious decay after 400 cycles.

17.
ACS Omega ; 3(12): 18685-18693, 2018 Dec 31.
Artículo en Inglés | MEDLINE | ID: mdl-31458434

RESUMEN

The use of metal-oxide sensors for effectively detecting hydrogen sulfide (H2S) gas at room temperature is currently hindered by their inadequate sensitivity and selectivity. Using a lucid fabrication strategy, we report a room-temperature, highly sensitive, and selective H2S gas sensor using NiO-modified WO3 nanorod (one-dimensional-one-dimensional) random networks. The observed improvements in gas-sensing sensitivity stem from the synergistic effects of various contributions inside the sensing heterostructure, such as bulk nanorod, p-n heterojunction at the interface of these two dissimilar oxides, and gas-induced conducting species due to sulfurization (WS2-x and NiS1-x ). An in situ impedance measurement during gas exposure was used to investigate the influence of these effects. The analysis revealed that these contributing factors can be either cooperating or competing and lead to either increased or decreased sensitivity, respectively. The presence of semimetallic species (NiS, WS2) was further confirmed by in situ X-ray diffraction analysis of the heterostructure nanorod sample with H2S gas exposure. The related sensing mechanism in the heterostructures is presented with a conduction pathway model. The room-temperature-operated nanorod heterostructure sensors showed a lower detection limit of H2S at ∼0.5 ppm, which is significantly lower than its toxicity limiting value ∼10 ppm, per the Environmental Protection Agency. The nanorod heterostructure sensors can be used for real-time, low-cost, room-temperature alarms in an H2S monitoring system.

18.
Biosens Bioelectron ; 110: 16-22, 2018 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-29579645

RESUMEN

Contamination of surface and drinking water due to the presence of Escherichia coli bacteria is a major cause of water-borne disease outbreak. To address unmet challenges for practical pathogen detection in contaminated samples, we report fabrication of thermally reduced graphene oxide-based field-effect transistor (rGO FET) passivated with an ultrathin layer of Al2O3 for real-time detection of E. coli bacteria. The sensor could detect a single E. coli cell within 50 s in a 1 µL sample volume. The ultrathin layer of Al2O3 acted as a barrier between rGO and potential interferents present in the sample. E. coli specific antibodies anchored on gold nanoparticles acted as probes for selective capture of E. coli. The high density of negative charge on the surface of E. coli cells strongly modulates the concentration of majority charge carriers in the rGO monolayer, thereby allowing real-time monitoring of E. coli concentration in a given sample. With a low detection limit of single cell, the FET sensor had a linear range of 1-100 CFU in 1 µL volume of sample (i.e., 103 to 105 CFU/ mL). The biosensor with good selectivity and rapid detection was further successfully demonstrated for E. coli sensing in river water. The rGO-based FET sensor provides a low cost and label-free approach, and can be mass produced for detection of a broad spectrum of pathogens in water or other liquid media.


Asunto(s)
Técnicas Biosensibles/instrumentación , Infecciones por Escherichia coli/microbiología , Escherichia coli/aislamiento & purificación , Grafito/química , Ríos/microbiología , Transistores Electrónicos , Técnicas Biosensibles/economía , Diseño de Equipo , Humanos , Límite de Detección , Óxidos/química , Factores de Tiempo
19.
Biosens Bioelectron ; 89(Pt 1): 505-510, 2017 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-27040183

RESUMEN

A black phosphorous (BP)-based field-effect transistor (FET) biosensor was fabricated by using few-layer BP nanosheets labeled with gold nanoparticle-antibody conjugates. BP nanosheets were mechanically exfoliated and used as the sensing/conducting channel in the FET, with an Al2O3 thin film as the dielectric layer for surface passivation. Antibody probes were conjugated with gold nanoparticles that were sputtered on the BP through surface functionalization. The sensor response was measured by the change in the BP's electrical resistance after antigens were introduced. The adsorbed antigens through specific antigen-antibody binding interactions induced a gate potential, thereby changing the drain-source current. The as-produced BP biosensor showed both high sensitivity (lower limit of detection ~10ng/ml) and selectivity towards human immunoglobulin G. Results from this study demonstrate the outstanding performance of BP as a sensing channel for FET biosensor applications.


Asunto(s)
Anticuerpos Inmovilizados/química , Técnicas Biosensibles/instrumentación , Inmunoglobulina G/análisis , Nanoestructuras/química , Fósforo/química , Transistores Electrónicos , Diseño de Equipo , Oro/química , Humanos , Límite de Detección
20.
Sci Rep ; 7(1): 10974, 2017 09 08.
Artículo en Inglés | MEDLINE | ID: mdl-28887479

RESUMEN

The Ebola virus transmits a highly contagious, frequently fatal human disease for which there is no specific antiviral treatment. Therefore, rapid, accurate, and early diagnosis of Ebola virus disease (EVD) is critical to public health containment efforts, particularly in developing countries where resources are few and EVD is endemic. We have developed a reduced graphene oxide-based field-effect transistor method for real-time detection of the Ebola virus antigen. This method uses the attractive semiconductor characteristics of graphene-based material, and instantaneously yields highly sensitive and specific detection of Ebola glycoprotein. The feasibility of this method for clinical application in point-of-care technology is evaluated using Ebola glycoprotein suspended in diluted PBS buffer, human serum, and plasma. These results demonstrate the successful fabrication of a promising field-effect transistor biosensor for EVD diagnosis.


Asunto(s)
Antígenos Virales , Técnicas Biosensibles , Ebolavirus , Fiebre Hemorrágica Ebola/diagnóstico , Transistores Electrónicos , Antígenos Virales/inmunología , Técnicas Biosensibles/instrumentación , Técnicas Biosensibles/métodos , Ebolavirus/inmunología , Diseño de Equipo , Fiebre Hemorrágica Ebola/inmunología , Humanos , Sistemas de Atención de Punto , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA