Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 95
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Catheter Cardiovasc Interv ; 103(4): 660-669, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38419402

RESUMEN

Transcatheter pulmonary valve replacement (TPVR), also known as percutaneous pulmonary valve implantation, refers to a minimally invasive technique that replaces the pulmonary valve by delivering an artificial pulmonary prosthesis through a catheter into the diseased pulmonary valve under the guidance of X-ray and/or echocardiogram while the heart is still beating not arrested. In recent years, TPVR has achieved remarkable progress in device development, evidence-based medicine proof and clinical experience. To update the knowledge of TPVR in a timely fashion, and according to the latest research and further facilitate the standardized and healthy development of TPVR in Asia, we have updated this consensus statement. After systematical review of the relevant literature with an in-depth analysis of eight main issues, we finally established eight core viewpoints, including indication recommendation, device selection, perioperative evaluation, procedure precautions, and prevention and treatment of complications.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Válvula Pulmonar , Humanos , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/cirugía , Resultado del Tratamiento , Asia , Catéteres
2.
Curr Cardiol Rep ; 24(5): 587-596, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35230616

RESUMEN

PURPOSE OF REVIEW: Establishing the Fontan circulation has led to improved survival in patients born with complex congenital heart diseases. Despite early success, the long-term course of Fontan patients is complicated by multi-organ dysfunction, mainly due to a combination of low resting and blunted exercise-augmented cardiac output as well as elevated central venous (Fontan) pressure. Similarly, despite absolute hemodynamic differences compared to the normal population with biventricular circulation, the "normal" ranges of hemodynamic parameters specific to age-appropriate Fontan circulation have not been well defined. With the ever-increasing population of patients requiring Fontan correction, it is of utmost importance that an acceptable range of hemodynamics in this highly complex patient cohort is better defined. RECENT FINDINGS: Multiple publications have described hemodynamic limitations and potential management options in patients with Fontan circulation; however, an acceptable range of hemodynamic parameters in this patient population has not been well defined. Identification of "normal" hemodynamic parameters among patients with Fontan circulation will allow physicians to more objectively define indications for intervention, which is a necessary first step to eliminate institutional and regional heterogeneity in Fontan management and potentially improve long-term clinical outcomes.


Asunto(s)
Procedimiento de Fontan , Cardiopatías Congénitas , Cardiopatías Congénitas/complicaciones , Hemodinámica , Humanos
3.
Catheter Cardiovasc Interv ; 98(1): 128-136, 2021 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-33909945

RESUMEN

BACKGROUND: Covered stent correction of sinus venosus ASDs (SVASD) is a relatively new technique. Challenges include anchoring a sufficiently long stent in a nonstenotic superior vena cava (SVC) and expanding the stent at the wider SVC-RA junction without obstructing the anomalous right upper pulmonary vein (RUPV). The 10-zig covered Cheatham-platinum (CCP) stent has the advantage of being available in lengths of 5-11 cm and dilatable to 34 mm in diameter. METHODS: An international registry reviewed the outcomes of 10-zig CCP stents in 75 patients aged 11.4-75.9 years (median 45.4) from March 2016. Additional stents were used to anchor the stent in the SVC or close residual shunts in 33/75. An additional stent was placed in 4/5 (80%) with 5/5.5 cm CCPs, 18/29 (62%) with 6 cm CCPs, 5/18 (28%) with 7 cm CCPs, 5/22 (23%) with 7.5/8 cm CCPs and 0/1 with an 11 cm CCP. A "protective" balloon catheter was inflated in the RUPV in 17. RESULTS: Early stent embolization in two patients required surgical removal and defect repair and tamponade was drained in one patient. The CT at 3 months showed occlusion of the RUPV in one patient. Follow up is from 2 months to 5.1 years (median 1.8 years). QP:QS has reduced from 2.5 ± 0.5 to 1.2 ± 0.36 (p < .001) and RVEDVi from 149.1 ± 35.4 to 95.6 ± 21.43 ml/m2 (p < .001). CONCLUSIONS: Ten-zig CCPs of 7-8 cm appear to provide reliable SVASD closure with a low requirement for additional stents. Careful selection of patients and meticulous attention to detail is required to avoid complications.


Asunto(s)
Defectos del Tabique Interatrial , Platino (Metal) , Humanos , Sistema de Registros , Stents , Resultado del Tratamiento , Vena Cava Superior
4.
Cardiol Young ; 31(8): 1376-1379, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33766177

RESUMEN

Transcatheter creation of an interatrial communication using the Occlutech Atrial Flow Regulator Device for pulmonary hypertension or heart failure is well described. We report a case of an 8-year-old boy with a failing Fontan circulation, in whom the Atrial Flow Regulator was used to successfully create a fenestration between the pulmonary artery and left atrium, improving his clinical condition.


Asunto(s)
Apéndice Atrial , Procedimiento de Fontan , Hipertensión Pulmonar , Cateterismo Cardíaco , Niño , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Humanos , Hipertensión Pulmonar/etiología , Masculino , Arteria Pulmonar/diagnóstico por imagen , Arteria Pulmonar/cirugía
5.
Curr Cardiol Rep ; 22(12): 158, 2020 10 09.
Artículo en Inglés | MEDLINE | ID: mdl-33037461

RESUMEN

PURPOSE OF REVIEW: Cardiac catheterization therapies to treat or palliate infants, children and adults with congenital heart disease have developed rapidly worldwide in both technical innovation and device development in the previous three decades. By reviewing of current status of novel or development of devices and techniques, we will discuss what is likely to happen in paediatric heart intervention in the next decade. RECENT FINDINGS: Recently, biodegradable stents and devices, transcatheter pulmonary valve implantation for the native right ventricle outflow tract and MRI-guided interventions have been progressing rapidly with good immediate to early results. These are expected to be introduced and spread in the next decade although there are still challenges to overcome. The future of paediatric heart intervention is very promising with rapid development of technological progress.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Cardiopatías Congénitas , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Adulto , Cateterismo Cardíaco , Niño , Cardiopatías Congénitas/cirugía , Humanos , Resultado del Tratamiento
6.
Cardiol Young ; 30(5): 649-655, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-32321616

RESUMEN

AIMS: Management strategies for pulmonary atresia with intact ventricular septum are variable and are based on right ventricular morphology and associated abnormalities. Catheter perforation of the pulmonary valve provides an alternative strategy to surgery in the neonatal period. We sought to assess the long-term outcome in terms of survival, re-intervention, and functional ventricular outcome in the setting of a 26-year single-centre experience of low threshold inclusion criteria for percutaneous valvotomy. METHODS AND RESULTS: Retrospective analysis of patients diagnosed with pulmonary atresia with intact ventricular septum from 1990 to 2016 at a tertiary referral centre, was performed. Of 71 patients, 48 were brought to the catheterisation laboratory for intervention. Catheter valvotomy was successful in 45 patients (94%). Twenty-three patients (51%) also underwent ductus arteriosus stenting. The length of intensive care and hospital stay was significantly shorter, and early re-interventions were significantly reduced in the catheterisation group. There were eight deaths (17%); all within 35 days of the procedure. Of the survivors, only one has required a Fontan circulation. Twenty-eight patients (74%) have undergone biventricular repair and nine patients (24%) have one-and-a-half ventricle circulation. Following successful valvotomy, 80% of patients required further catheter-based or surgical interventions. CONCLUSIONS: A low threshold for initial interventional management yielded a high rate of successful biventricular circulations. Although mortality was low in patients who survived the peri-procedural period, the rate of re-intervention remained high in all groups.


Asunto(s)
Cateterismo Cardíaco/instrumentación , Ablación por Catéter/efectos adversos , Cardiopatías Congénitas/cirugía , Atresia Pulmonar/cirugía , Válvula Pulmonar/cirugía , Stents , Cateterismo Cardíaco/efectos adversos , Femenino , Humanos , Lactante , Recién Nacido , Tiempo de Internación , Masculino , Estudios Retrospectivos , Tasa de Supervivencia , Resultado del Tratamiento
7.
J Radiol Prot ; 40(1): 311-318, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-31731286

RESUMEN

We conducted a survey of doctors working in the cardiac catheterisation laboratories in Africa on their knowledge, attitude and practice with respect to radiation protection. Of seventy-two respondents contacted, 61 (84.7%) completed the questionnaire. Twenty-eight, (45.9%) were younger than 45 years. Thirty-seven, (60.6%) had less than 10 years of experience in the laboratory. Only 28 (45.9%) had undertaken radiation protection training. Fifty-eight, (95.1%) consistently used lead aprons. Forty-seven, (77%) reported consistently using thyroid shields. Ten (16.4%) consistently used radiation protection eyeglasses, whilst 36 (59%) never used them. Thermoluminescent Dosimeter badges were consistently used in 23 (37.7%). Forty-two, (68.9%) reported having ceiling mounted lead/acrylic shields. Level of radiation exposure in the most recent one year was ≤2 mSv in 14, between 2 and 20 mSv in 8 and between 20 and 30 mSv in 2, whilst 33 did not know their dose readings. The use of basic radiation protection tools as well as the knowledge and measurement of radiation exposure among interventional cardiologists working in Africa is low. The unavailability of some of the protective tools and a knowledge gap in terms of radiation protection and monitoring of self-exposure were some of the reasons for suboptimal self-protection against ionising radiation among our respondents. We suggest that initiatives be taken by all stakeholders to train this group of medical professionals in basic radiation protection to avoid unnecessary exposure to themselves, co-workers and patients.


Asunto(s)
Cardiólogos , Conocimientos, Actitudes y Práctica en Salud , Protección Radiológica , Radiología Intervencionista , Adulto , Estudios Transversales , Etiopía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Encuestas y Cuestionarios
9.
Cardiol Young ; 29(4): 534-537, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30968796

RESUMEN

We describe percutaneous repair of severe pulmonary regurgitation and a right ventricular outflow tract pseudoaneurysm in a 19-year-old patient after repair of pulmonary atresia, ventricular septal defect, and major aortopulmonary collaterals. A 3D printed model of his heart was used to simulate percutaneous repair with a closure device in the aneurysm neck and a Venus P-valve in the right ventricular outflow tract. The encouraging findings from the simulation allowed us to plan the complex procedure effectively with a successful outcome and avoidance of surgery.


Asunto(s)
Aneurisma Falso/cirugía , Modelos Anatómicos , Impresión Tridimensional , Insuficiencia de la Válvula Pulmonar/cirugía , Obstrucción del Flujo Ventricular Externo/cirugía , Aneurisma Falso/etiología , Aorta Torácica/cirugía , Procedimientos Quirúrgicos Cardíacos , Circulación Colateral , Angiografía Coronaria , Defectos del Tabique Interventricular/complicaciones , Defectos del Tabique Interventricular/cirugía , Implantación de Prótesis de Válvulas Cardíacas , Humanos , Imagen por Resonancia Magnética , Masculino , Atresia Pulmonar/complicaciones , Atresia Pulmonar/cirugía , Insuficiencia de la Válvula Pulmonar/etiología , Obstrucción del Flujo Ventricular Externo/etiología , Adulto Joven
10.
Cardiol Young ; 29(8): 1009-1015, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-31244446

RESUMEN

The range and number of educational and networking events that are available for fellows, trainees, and junior faculty to attend grows every year. Each meeting useful in its own way; each adding value to the development and the growth of an interventionist. Within paediatric, congenital, and structural heart disease, three of the standout meetings are: Pediatric and Interventional Cardiac Symposium (PICS-AICS), Congenital and Structural Interventions (CSI), and International Workshop on Interventional Pediatric and Adult Congenital Cardiology (IPC). All of these were started by leaders in our field; people known to be passionate educators and innovators. International congresses focusing more broadly on congenital cardiac disease in children and adults are rare. These forums allow more interdisciplinary discussions between the interventionist, surgeon, and non-invasive specialists. Purely interventional meetings are essential to allow colleagues to debate and explore the nuances and intricacies of technique and approach, developing concepts to be challenged in wider forums. During the recent 21st PICS-AICS meeting Prof. Ziyad M. Hijazi, Shakeel A. Qureshi, Mario Carminati, and Dr Damien Kenny shared their time to engage in frank, recorded conversations which provide a unique insight in to the process and concepts behind three of our most important educational congresses.


Asunto(s)
Cardiología , Congresos como Asunto , Pediatría , Cardiopatías Congénitas/diagnóstico , Cardiopatías Congénitas/terapia , Humanos , Sociedades Médicas
12.
Pediatr Cardiol ; 39(7): 1308-1314, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-29744658

RESUMEN

A comprehensive understanding of the native pulmonary blood supply is crucial in newborns with pulmonary atresia with ventricular septal defect and aortopulmonary collaterals (PA/VSD/MAPCA). We sought to describe the accuracy in terms of identifying native pulmonary arteries, radiation dose and anaesthetic time associated with multi-modality imaging in these patients, prior to their first therapeutic intervention. Furthermore, we wanted to evaluate the cumulative radiations dose and anaesthetic time over the study period. Patients with PA/VSD/MAPCA diagnosed at < 100 days between 2004 and 2014 were identified. Cumulative radiation dose and anaesthetic times were calculated, with imaging results compared with intraoperative findings. We then calculated the cumulative risks to date for all surviving children. Of 19 eligible patients, 2 had echocardiography only prior to first intervention. The remaining 17 patients underwent 13 MRIs, 4 CT scans and 13 cardiac catheterization procedures. The mean radiation dose was 169 mGy cm2 (47-461 mGy cm2), and mean anaesthetic time was 111 min (33-185 min). 3 children had MRI only with no radiation exposure, and one child had CT only with no anaesthetic. Early cross-sectional imaging allowed for delayed catheterisation, but without significantly reducing radiation burden or anaesthetic time. The maximum cumulative radiation dose was 8022 mGy cm2 in a 6-year-old patient and 1263 min of anaesthetic at 5 years. There is the potential to generate very high radiation doses and anaesthetic times from diagnostic imaging alone in these patients. As survival continues to improve in many congenital heart defects, the important risks of serial diagnostic imaging must be considered when planning long-term management.


Asunto(s)
Cateterismo Cardíaco/efectos adversos , Defectos de los Tabiques Cardíacos/diagnóstico por imagen , Imagen por Resonancia Magnética/efectos adversos , Atresia Pulmonar/diagnóstico por imagen , Dosis de Radiación , Tomografía Computarizada por Rayos X/efectos adversos , Adolescente , Anestesia/efectos adversos , Anestesia/estadística & datos numéricos , Anestésicos/administración & dosificación , Anestésicos/efectos adversos , Cateterismo Cardíaco/estadística & datos numéricos , Niño , Preescolar , Circulación Colateral , Ecocardiografía/estadística & datos numéricos , Femenino , Defectos de los Tabiques Cardíacos/cirugía , Humanos , Lactante , Recién Nacido , Imagen por Resonancia Magnética/estadística & datos numéricos , Masculino , Imagen Multimodal/efectos adversos , Imagen Multimodal/métodos , Arteria Pulmonar/diagnóstico por imagen , Atresia Pulmonar/cirugía , Estudios Retrospectivos , Medición de Riesgo/métodos , Tomografía Computarizada por Rayos X/estadística & datos numéricos , Reino Unido
13.
Circulation ; 134(13): 934-44, 2016 Sep 27.
Artículo en Inglés | MEDLINE | ID: mdl-27587432

RESUMEN

BACKGROUND: Paravalvular leak (PVL) occurs in 5% to 17% of patients following surgical valve replacement. Percutaneous device closure represents an alternative to repeat surgery. METHODS: All UK and Ireland centers undertaking percutaneous PVL closure submitted data to the UK PVL Registry. Data were analyzed for association with death and major adverse cardiovascular events (MACE) at follow-up. RESULTS: Three hundred eight PVL closure procedures were attempted in 259 patients in 20 centers (2004-2015). Patient age was 67±13 years; 28% were female. The main indications for closure were heart failure (80%) and hemolysis (16%). Devices were successfully implanted in 91% of patients, via radial (7%), femoral arterial (52%), femoral venous (33%), and apical (7%) approaches. Nineteen percent of patients required repeat procedures. The target valve was mitral (44%), aortic (48%), both (2%), pulmonic (0.4%), or transcatheter aortic valve replacement (5%). Preprocedural leak was severe (61%), moderate (34%), or mild (5.7%) and was multiple in 37%. PVL improved postprocedure (P<0.001) and was none (33.3%), mild (41.4%), moderate (18.6%), or severe (6.7%) at last follow-up. Mean New York Heart Association class improved from 2.7±0.8 preprocedure to 1.6±0.8 (P<0.001) after a median follow-up of 110 (7-452) days. Hospital mortality was 2.9% (elective), 6.8% (in-hospital urgent), and 50% (emergency) (P<0.001). MACE during follow-up included death (16%), valve surgery (6%), late device embolization (0.4%), and new hemolysis requiring transfusion (1.6%). Mitral PVL was associated with higher MACE (hazard ratio [HR], 1.83; P=0.011). Factors independently associated with death were the degree of persisting leak (HR, 2.87; P=0.037), New York Heart Association class (HR, 2.00; P=0.015) at follow-up and baseline creatinine (HR, 8.19; P=0.001). The only factor independently associated with MACE was the degree of persisting leak at follow-up (HR, 3.01; P=0.002). CONCLUSION: Percutaneous closure of PVL is an effective procedure that improves PVL severity and symptoms. Severity of persisting leak at follow-up is independently associated with both MACE and death. Percutaneous closure should be considered as an alternative to repeat surgery.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Válvula Mitral/cirugía , Complicaciones Posoperatorias/etiología , Falla de Prótesis/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter , Adulto , Anciano , Anciano de 80 o más Años , Cateterismo Cardíaco/métodos , Femenino , Insuficiencia Cardíaca/etiología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Irlanda , Masculino , Persona de Mediana Edad , Reoperación/métodos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reino Unido
14.
Catheter Cardiovasc Interv ; 90(3): 425-431, 2017 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-28707350

RESUMEN

PURPOSE: Endovascular treatment of coarctation of aorta (CoA) by self-expandable Nitinol stents is one of the recognized treatment methods and may be an alternative to surgery or balloon-expandable stent implantation for CoA but there is little information about midterm to long term results of self-expandable stents. METHODS: Sixty-two patients with CoA (40 men), with a mean age of 30.7 ± 11 years, (range 17-63 years) underwent stent implantation with Optimed self-expandable Nitinol stents between 2005 and 2014. Successful outcome was defined as peak systolic pressure gradient ≤20 mmHg after stent implantation. The patients were followed-up clinically and by echocardiography and in patients, in whom there was suspicion of recoarctation, CT angiography or recatheterization was performed. RESULTS: 65 stents were successfully implanted in all 62 patients. Peak systolic pressure gradient decreased from mean 62.4 ± 18 mmHg (range 35-100 mmHg) to mean 2.8 ± 5 mmHg (range 0-15 mmHg; P < 0.001). Stent displacement occurred in 3 patients during the procedure. These were managed successfully by an overlapping second stent. None of the patients had major complications such as aortic dissection, rupture, or vascular access problems. In follow up, only three patients had recoarctation, and two of these were managed successfully by balloon redilation or further stenting 16 and 18 months after the first procedure and one patient refused reintervention. There were two deaths, unrelated to the procedure, 12 and 78 months after the initial intervention. Follow-up of a mean of 45.5 ± 17 months (range 12-105 months) demonstrated no evidence of aneurysm formation or stent fracture. CONCLUSIONS: Self-expandable nitinol stents for the treatment of native and recurrent CoA is safe and has good efficacy with acceptable midterm to long-term outcome.


Asunto(s)
Aleaciones , Coartación Aórtica/terapia , Procedimientos Endovasculares/instrumentación , Stents Metálicos Autoexpandibles , Adolescente , Adulto , Coartación Aórtica/diagnóstico por imagen , Coartación Aórtica/fisiopatología , Aortografía/métodos , Presión Arterial , Angiografía por Tomografía Computarizada , Ecocardiografía , Procedimientos Endovasculares/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diseño de Prótesis , Recurrencia , Retratamiento , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
15.
Cardiol Young ; 27(8): 1465-1469, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28857726

RESUMEN

Aims We sought to evaluate the first-in-man use of a new system for implantation of covered stents in patients with complex structural and CHD. Methods and results Retrospective data were collected of the first 13 NuDEL™ delivery systems used in patients. The NuDEL™ comprises a covered Cheatham-Platinum stent mounted on a balloon-in-balloon and pre-loaded in a long delivery sheath. Data were collected from three centres in the United Kingdom and Ireland. A total of 13 covered stents were delivered via 12 NuDEL™ delivery systems in 12 patients. Among them, six patients had coarctation of the aorta, five patients had right ventricular outflow tract stenosis, and one patient had severe stenosis of a Mustard systemic venous baffle. There were no complications, and all the stents were deployed in the desired position with satisfactory haemodynamic results. CONCLUSIONS: The development of a bespoke system of a pre-mounted, pre-loaded covered stent may negate some of the technical challenges that complicate large-calibre stent deployment. Our preliminary results suggest that the NuDEL™ system is a safe and effective means of covered stent deployment in challenging anatomy.


Asunto(s)
Coartación Aórtica/cirugía , Implantación de Prótesis Vascular/instrumentación , Materiales Biocompatibles Revestidos , Stents , Adolescente , Adulto , Coartación Aórtica/diagnóstico , Aortografía , Niño , Diseño de Equipo , Femenino , Humanos , Masculino , Platino (Metal)/farmacología , Diseño de Prótesis , Estudios Retrospectivos , Resultado del Tratamiento , Adulto Joven
16.
Cardiol Young ; 27(5): 837-845, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28555538

RESUMEN

OBJECTIVES: We aimed to compare the procedural and mid-term performance of a specifically designed self-expanding stent with balloon-expandable stents in patients undergoing hybrid palliation for hypoplastic left heart syndrome and its variants. BACKGROUND: The lack of specifically designed stents has led to off-label use of coronary, biliary, or peripheral stents in the neonatal ductus arteriosus. Recently, a self-expanding stent, specifically designed for use in hypoplastic left heart syndrome, has become available. METHODS: We carried out a retrospective cohort comparison of 69 neonates who underwent hybrid ductal stenting with balloon-expandable and self-expanding stents from December, 2005 to July, 2014. RESULTS: In total, 43 balloon-expandable stents were implanted in 41 neonates and more recently 47 self-expanding stents in 28 neonates. In the balloon-expandable stents group, stent-related complications occurred in nine patients (22%), compared with one patient in the self-expanding stent group (4%). During follow-up, percutaneous re-intervention related to the ductal stent was performed in five patients (17%) in the balloon-expandable stent group and seven patients (28%) in self-expanding stents group. CONCLUSIONS: Hybrid ductal stenting with self-expanding stents produced favourable results when compared with the results obtained with balloon-expandable stents. Immediate additional interventions and follow-up re-interventions were similar in both groups with complications more common in those with balloon-expandable stents.


Asunto(s)
Implantación de Prótesis Vascular , Síndrome del Corazón Izquierdo Hipoplásico/cirugía , Cuidados Paliativos , Stents , Conducto Arterial/cirugía , Femenino , Humanos , Recién Nacido , Estimación de Kaplan-Meier , Masculino , Uso Fuera de lo Indicado , Diseño de Prótesis , Arteria Pulmonar/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Reino Unido
17.
Cardiol Young ; 27(1): 26-36, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27133447

RESUMEN

BACKGROUND: In patients with large patent arterial ducts and severe pulmonary hypertension, the natural history of progression of pulmonary hypertension is very variable. Whether to close or not to close is often a difficult decision, as there are no established haemodynamic parameters predicting reversibility. OBJECTIVES: The objectives of this study were to evaluate the results of device closure of large patent arterial ducts with severe pulmonary hypertension after 2 years of age and to determine haemodynamic variables associated with its regression during long-term follow-up. METHODS: A total of 45 patients, with median age of 10 (2-27) years, with large patent arterial ducts and severe pulmonary hypertension, were considered. Haemodynamic variables were assessed in air, oxygen, and after occlusion. The follow-up was performed to assess regression of pulmonary hypertension. RESULTS: Device closure was successful in 43 (96%) patients. Pulmonary artery systolic and mean pressures decreased from 79 to 67 mmHg and from 59 to 50 mmHg, respectively (p25% (both in oxygen) (p=0.007). CONCLUSIONS: Device closure of large patent arterial ducts with severe pulmonary hypertension is safe and effective. Pulmonary vascular resistance index and systolic and mean pulmonary artery pressures in oxygen are the key prognostic variables predicting regression of pulmonary hypertension.


Asunto(s)
Presión Sanguínea/fisiología , Cateterismo Cardíaco/métodos , Conducto Arterioso Permeable/cirugía , Hipertensión Pulmonar/etiología , Adolescente , Adulto , Aortografía , Niño , Preescolar , Conducto Arterioso Permeable/complicaciones , Conducto Arterioso Permeable/diagnóstico , Ecocardiografía , Femenino , Estudios de Seguimiento , Humanos , Hipertensión Pulmonar/diagnóstico , Hipertensión Pulmonar/fisiopatología , Masculino , Pronóstico , Estudios Retrospectivos , Dispositivo Oclusor Septal , Índice de Severidad de la Enfermedad , Factores de Tiempo , Adulto Joven
18.
Catheter Cardiovasc Interv ; 87(2): 302-9, 2016 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-26527119

RESUMEN

OBJECTIVES: We sought to develop a scoring system that predicts the risk of serious adverse events (SAE's) for individual pediatric patients undergoing cardiac catheterization procedures. BACKGROUND: Systematic assessment of risk of SAE in pediatric catheterization can be challenging in view of a wide variation in procedure and patient complexity as well as rapidly evolving technology. METHODS: A 10 component scoring system was originally developed based on expert consensus and review of the existing literature. Data from an international multi-institutional catheterization registry (CCISC) between 2008 and 2013 were used to validate this scoring system. In addition we used multivariate methods to further refine the original risk score to improve its predictive power of SAE's. RESULTS: Univariate analysis confirmed the strong correlation of each of the 10 components of the original risk score with SAE attributed to a pediatric cardiac catheterization (P < 0.001 for all variables). Multivariate analysis resulted in a modified risk score (CRISP) that corresponds to an increase in value of area under a receiver operating characteristic curve (AUC) from 0.715 to 0.741. CONCLUSION: The CRISP score predicts risk of occurrence of an SAE for individual patients undergoing pediatric cardiac catheterization procedures.


Asunto(s)
Cateterismo Cardíaco/efectos adversos , Técnicas de Apoyo para la Decisión , Cardiopatías Congénitas/terapia , Pediatría/métodos , Adolescente , Factores de Edad , Área Bajo la Curva , Distribución de Chi-Cuadrado , Niño , Preescolar , Cardiopatías Congénitas/diagnóstico , Humanos , Lactante , Recién Nacido , Modelos Logísticos , Análisis Multivariante , Valor Predictivo de las Pruebas , Curva ROC , Sistema de Registros , Reproducibilidad de los Resultados , Medición de Riesgo , Factores de Riesgo , Resultado del Tratamiento
19.
Cardiol Young ; 26(5): 915-20, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26381209

RESUMEN

OBJECTIVES: The aim of this study was to describe the clinical characteristics, progression, treatment, and outcomes in isolated coronary artery fistula cases diagnosed prenatally. METHODS: We carried out a retrospective review of babies diagnosed prenatally with coronary artery fistulas between January, 2000 and December, 2013; five fetuses were included. Echocardiographic features and measurements were noted during pregnancy and after birth. Treatment and outcome were noted. RESULTS: Gestational age at initial diagnosis was between 19 and 22 weeks; four coronary artery fistulas originated from the right and one from the left circumflex coronary artery. Drainage was into the right atrium in four cases and into the left ventricle in one case. There was cardiomegaly in two cases at the initial scan. The size of the fistulas increased during pregnancy in all except one. All prenatal diagnoses were confirmed postnatally. Among all, two patients developed congestive cardiac failure soon after birth and required transcatheter closure of the coronary artery fistula, 5 and 17 days after birth, respectively; three patients remained asymptomatic, and all of them showed progressive dilation of the feeding artery and had closure of the fistula at 20 months, 4 years, and 7 years of age, respectively. During the follow-up period, which ranged 2-14 years, all the patients were alive and well. CONCLUSIONS: Coronary artery fistulas can be diagnosed accurately during fetal life. Some babies may develop congestive cardiac failure soon after birth requiring early treatment. Those treated conservatively should be kept under review as intervention may be required later.


Asunto(s)
Anomalías de los Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/fisiopatología , Feto/diagnóstico por imagen , Fístula/diagnóstico por imagen , Diagnóstico Prenatal , Niño , Preescolar , Progresión de la Enfermedad , Ecocardiografía , Femenino , Estudios de Seguimiento , Atrios Cardíacos , Ventrículos Cardíacos , Humanos , Lactante , Recién Nacido , Masculino , Embarazo , Estudios Retrospectivos , Centros de Atención Terciaria
20.
Cardiol Young ; 26(4): 698-710, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26088820

RESUMEN

BACKGROUND: At present, the exclusion for percutaneous pulmonary valve implantation for free pulmonary regurgitation after tetralogy of Fallot repair includes an unfavourably large right ventricular outflow tract. OBJECTIVE: To report feasibility and early experience with a recently developed transcatheter heart valve, Venus P-valveTM, implanted in six patients with severe pulmonary regurgitation with large right ventricular outflow tracts. Patients There were two female patients and four male patients. The median age of the patients was 18.5 years, and the mean body weight was 53.8 kg. All the patients were in NYHA class II and had severe pulmonary regurgitation after previous transannular patch repair of tetralogy of Fallot. The median time after the last surgical operation was 13.5 years. RESULTS: The Venus P-valveTM was successfully implanted in all the patients with implanted valve diameters ranging from 24 to 32 mm. The mean fluoroscopy time was 29.8 minutes. None of the patients had significant outflow tract gradient or pulmonary regurgitation immediately after valve implantation. Only one patient had unexpected mild proximal valve migration to the right ventricular body during withdrawal of the delivery system. It caused mild paravalvar leak and significant tricuspid regurgitation. At 6 months follow-up, the median of right ventricular end-diastolic volume indices decreased from 146 to 108 ml/m2 (p-value=0.046). The Doppler systolic peak gradient across the valve ranged from 4 to 40 mmHg, and there was no evidence of stent fracture on fluoroscopy or structural valve failure. CONCLUSION: The Venus P-valveTM can be implanted successfully and effectively in patients with severe pulmonary regurgitation and a large right ventricular outflow tract. The early results with this valve are encouraging.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas/métodos , Insuficiencia de la Válvula Pulmonar/cirugía , Válvula Pulmonar/cirugía , Adolescente , Diseño de Equipo , Femenino , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Humanos , Masculino , Diseño de Prótesis , Resultado del Tratamiento , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA