Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Pediatr Radiol ; 2024 Jul 17.
Artículo en Inglés | MEDLINE | ID: mdl-39017676

RESUMEN

BACKGROUND: Ventricular volumetry using a short-axis stack of two-dimensional (D) cine balanced steady-state free precession (bSSFP) sequences is crucial in any cardiac magnetic resonance imaging (MRI) examination. This task becomes particularly challenging in children due to multiple breath-holds. OBJECTIVE: To assess the diagnostic performance of accelerated 3-RR cine MRI sequences using deep learning reconstruction compared with standard 2-D cine bSSFP sequences. MATERIAL AND METHODS: Twenty-nine consecutive patients (mean age 11 ± 5, median 12, range 1-17 years) undergoing cardiac MRI were scanned with a conventional segmented 2-D cine and a deep learning accelerated cine (three heartbeats) acquisition on a 1.5-tesla scanner. Short-axis volumetrics were performed (semi-)automatically in both datasets retrospectively by two experienced readers who visually assessed image quality employing a 4-point grading scale. Scan times and image quality were compared using the Wilcoxon rank-sum test. Volumetrics were assessed with linear regression and Bland-Altman analyses, and measurement agreement with intraclass correlation coefficient (ICC). RESULTS: Mean acquisition time was significantly reduced with the 3-RR deep learning cine compared to the standard cine sequence (45.5 ± 13.8 s vs. 218.3 ± 44.8 s; P < 0.001). No significant differences in biventricular volumetrics were found. Left ventricular (LV) mass was increased in the deep learning cine compared with the standard cine sequence (71.4 ± 33.1 g vs. 69.9 ± 32.5 g; P < 0.05). All volumetric measurements had an excellent agreement with ICC > 0.9 except for ejection fraction (EF) (LVEF 0.81, RVEF 0.73). The image quality of deep learning cine images was decreased for end-diastolic and end-systolic contours, papillary muscles, and valve depiction (2.9 ± 0.5 vs. 3.5 ± 0.4; P < 0.05). CONCLUSION: Deep learning cine volumetrics did not differ significantly from standard cine results except for LV mass, which was slightly overestimated with deep learning cine. Deep learning cine sequences result in a significant reduction in scan time with only slightly lower image quality.

2.
Pediatr Cardiol ; 45(4): 749-758, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38381183

RESUMEN

To report the prevalence of coarctation of the aorta (CoA) in fetuses with single left superior vena cava (SL-SVC) and to evaluate changes in echocardiographic measurements. Additionally, to report the prevalence of associated malformations. Retrospective observational study of fetuses diagnosed with SL-SVC between 2012 and 2021 at a tertiary fetal cardiology unit. In fetuses without intracardiac abnormalities, Z-scores of the ventricles, great arteries, and Doppler flow patterns are reported. We identified 47 fetuses with SL-SVC of which 8/47 (17%) had abnormal intracardiac anatomy. One fetus was lost to follow-up. Of those with normal intracardiac anatomy and postnatal follow-up (38), karyotype abnormalities were confirmed in 2/38 (5%) and ECA in 8/38 (21%). 33/38 were live-born. None developed CoA postnatally. Paired analysis of Z-scores between early and late scans of 24 fetuses showed that diameters of the right heart structures and Doppler flows of tricuspid valve increased significantly during pregnancy, while the left heart structures and flow patterns did not change. The median risk of CoA did not change between the early and the late scan. We did not observe CoA in this cohort. A degree of ventricular asymmetry was present, but this was due to right heart dominance rather than hypoplasia of left heart structures. This likely reflects redistribution of blood and does not appear to confer increased risk of CoA. Predictive models of the postnatal development of CoA which set the dimensions of right and left heart structures in relation might not be applicable in this situation.


Asunto(s)
Coartación Aórtica , Cardiopatías Congénitas , Embarazo , Femenino , Humanos , Coartación Aórtica/diagnóstico por imagen , Vena Cava Superior/diagnóstico por imagen , Ultrasonografía Prenatal/métodos , Aorta/diagnóstico por imagen , Corazón , Estudios Retrospectivos , Edad Gestacional
3.
J Cardiovasc Magn Reson ; 23(1): 140, 2021 12 30.
Artículo en Inglés | MEDLINE | ID: mdl-34969397

RESUMEN

BACKGROUND: Recent evidence shows an association between coronavirus disease 2019 (COVID-19) infection and a severe inflammatory syndrome in children. Cardiovascular magnetic resonance (CMR) data about myocardial injury in children are limited to small cohorts. The aim of this multicenter, international registry is to describe clinical and cardiac characteristics of multisystem inflammatory syndrome in children (MIS-C) associated with COVID-19 using CMR so as to better understand the real extent of myocardial damage in this vulnerable cohort. METHODS AND RESULTS: Hundred-eleven patients meeting the World Health Organization criteria for MIS-C associated with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), having clinical cardiac involvement and having received CMR imaging scan were included from 17 centers. Median age at disease onset was 10.0 years (IQR 7.0-13.8). The majority of children had COVID-19 serology positive (98%) with 27% of children still having both, positive serology and polymerase chain reaction (PCR). CMR was performed at a median of 28 days (19-47) after onset of symptoms. Twenty out of 111 (18%) patients had CMR criteria for acute myocarditis (as defined by the Lake Louise Criteria) with 18/20 showing subepicardial late gadolinium enhancement (LGE). CMR myocarditis was significantly associated with New York Heart Association class IV (p = 0.005, OR 6.56 (95%-CI 1.87-23.00)) and the need for mechanical support (p = 0.039, OR 4.98 (95%-CI 1.18-21.02)). At discharge, 11/111 (10%) patients still had left ventricular systolic dysfunction. CONCLUSION: No CMR evidence of myocardial damage was found in most of our MIS-C cohort. Nevertheless, acute myocarditis is a possible manifestation of MIS-C associated with SARS-CoV-2 with CMR evidence of myocardial necrosis in 18% of our cohort. CMR may be an important diagnostic tool to identify a subset of patients at risk for cardiac sequelae and more prone to myocardial damage. CLINICAL TRIAL REGISTRATION: The study has been registered on ClinicalTrials.gov, Identifier NCT04455347, registered on 01/07/2020, retrospectively registered.


Asunto(s)
COVID-19 , Miocarditis , COVID-19/complicaciones , Niño , Medios de Contraste , Gadolinio , Humanos , Espectroscopía de Resonancia Magnética , Miocarditis/diagnóstico por imagen , Miocarditis/epidemiología , Valor Predictivo de las Pruebas , Sistema de Registros , SARS-CoV-2 , Síndrome de Respuesta Inflamatoria Sistémica
4.
J Magn Reson Imaging ; 51(3): 897-903, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31507010

RESUMEN

BACKGROUND: T1 mapping is useful to quantify diffuse myocardial processes such as fibrosis, edema, storage disorders, or hemochromatosis. Normal pediatric myocardial T1 values are scarce using modified Look-Locker inversion recovery (MOLLI) sequences and unavailable using Smart1Map, a single-point saturation recovery sequence that measures true T1 . PURPOSE/HYPOTHESIS: To establish normal pediatric myocardial T1 values by Smart1Map and to compare them with T1 by MOLLI. STUDY TYPE: Prospective cohort study. SUBJECTS: Thirty-four children and adolescents aged 8-18 years (14 males) without cardiovascular or inflammatory diseases. FIELD STRENGTH/SEQUENCES: 1.5T, MOLLI, Smart1Map. ASSESSMENT: Mean T1 values of the left ventricular myocardium, the interventricular septum, and the blood pool were measured with MOLLI and Smart1Map in basal, mid-ventricular, and apical short axis slices. STATISTICAL TESTS: T1 values were compared between locations and methods by paired samples t-tests, Wilcoxon signed ranks test, repeated-measures analysis of variance (ANOVA), or Friedman's test. Pearson's correlation coefficient was calculated. For interobserver variability, intraclass correlation coefficients and coefficients of variation were calculated, and Bland-Altman analyses were performed. RESULTS: T1 values were longer by Smart1Map than by MOLLI in all measured locations (myocardium: 1191-1221 vs. 990-1042 msec; all P < 0.001). T1 in basal vs. mid-ventricular slices differed both by MOLLI and by Smart1Map for myocardium and for blood (all P < 0.001). Myocardial T1 did not correlate with age, heart rate, right or left ventricular ejection fraction (all P > 0.05) by either method. Septal vs. total myocardial T1 values in each slice did not differ by MOLLI (basal P = 0.371; mid-ventricular P = 0.08; apical P = 0.378) nor by Smart1Map (basal P = 0.056; mid-ventricular P = 0.918; apical P = 0. 392), after artifacts had been carefully excluded. DATA CONCLUSION: We established pediatric normal native T1 values using the Smart1Map sequence and compared the results with T1 mapping with MOLLI. Septal T1 values did not differ from total myocardial T1 values in each of the myocardial slices. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2020;51:897-903.


Asunto(s)
Imagen por Resonancia Magnética , Función Ventricular Izquierda , Adolescente , Niño , Humanos , Masculino , Miocardio , Valor Predictivo de las Pruebas , Estudios Prospectivos , Reproducibilidad de los Resultados , Volumen Sistólico
5.
Diagnostics (Basel) ; 13(2)2023 Jan 04.
Artículo en Inglés | MEDLINE | ID: mdl-36672990

RESUMEN

In many cardiac diseases, right and left ventricular volumes in systole and diastole are diagnostically and prognostically relevant. Measurements are made by segmentation of the myocardial borders on cardiac magnetic resonance (CMR) images. Automatic detection of myocardial contours is possible by signal thresholding techniques, but must be validated before use in clinical settings. Biventricular volumes were measured in end-diastole (EDVi) and in end-systole (ESVi) both manually and with the MassK application, with signal thresholds at 30%, 50%, and 70%. Stroke volumes (SV) and cardiac indices (CI) were calculated from volumetric measurements and from flow measured in the ascending aorta and the main pulmonary artery, and both methods were compared. Reproducibility of volumetric measurements was tested in 20 patients. Measurements were acquired in 94 patients aged 15 ± 9 years referred for various conditions. EDVi and ESVi of both ventricles were largest with manual segmentation and inversely proportional to the MassK threshold. Manual and k30 SV and CI corresponded best to flow measurements. Interobserver variability was low for all volumes manually and with MassK. In conclusion, manual and 30% threshold-based biventricular volume segmentation agree best with two-dimensional, phantom-corrected phase contrast flow measurements in a young cardiac referral population and are well reproducible.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA