Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Europace ; 20(7): 1209-1216, 2018 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-29016778

RESUMEN

Aims: Pacing from the left ventricular (LV) endocardium might increase the likelihood of response to cardiac resynchronization therapy. However, experimental and clinical data supporting this assumption are limited and controversial. The aim of this study was to compare the acute response of biventricular pacing from the LV epicardium and endocardium in a swine non-ischaemic cardiomyopathy (NICM) model of dyssynchrony. Methods and results: A NICM was induced in six swine by 3 weeks of rapid ventricular pacing. Biventricular stimulation was performed from 16 paired locations in the LV (8 epicardial and 8 endocardial) with two different atrioventricular (80 and 110 ms) intervals and three interventricular (0, +30, -30 ms) delays. The acute response of the aortic blood flow, LV and right ventricular (RV) pressures, LVdP/dtmax and LVdP/dtmin and QRS complex width and QT duration induced by biventricular stimulation were analysed. The haemodynamic and electrical beneficial responses to either LV endocardial or epicardial biventricular pacing were similar (ΔLVdP/dtmax: +7.8 ± 2.2% ENDO vs. +7.3 ± 1.5% EPI, and ΔQRS width: -16.8 ± 1.3% ENDO vs. -17.1 ± 1.9% EPI; P = ns). Pacing from LV basal regions either from the epicardium or endocardium produced better haemodynamic responses as compared with mid or apical LV regions (P < 0.05). The LV regions producing the maximum QRS complex shortening did not correspond to those inducing the best haemodynamic responses (EPI: r2 = 0.013, P = ns; ENDO: r2 = 0.002, P = ns). Conclusion: Endocardial LV pacing induced similar haemodynamic changes than pacing from the epicardium. The response to endocardial LV pacing is region dependent as observed in epicardial pacing.


Asunto(s)
Arritmias Cardíacas/terapia , Terapia de Resincronización Cardíaca/métodos , Cardiomiopatías/complicaciones , Endocardio/fisiopatología , Insuficiencia Cardíaca/terapia , Pericardio/fisiopatología , Función Ventricular Izquierda , Función Ventricular Derecha , Animales , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiología , Arritmias Cardíacas/fisiopatología , Cardiomiopatías/diagnóstico , Cardiomiopatías/fisiopatología , Modelos Animales de Enfermedad , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/fisiopatología , Sus scrofa , Factores de Tiempo
2.
J Cardiovasc Electrophysiol ; 24(10): 1157-62, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23718822

RESUMEN

INTRODUCTION: Open-irrigated radiofrequency ablation catheters with slight differences in tip architecture are widely used, although limited comparative data are available. The purpose of this study was to compare the lesion size and potential complications produced by commercially available open-irrigated catheters in an in vitro porcine heart model. METHODS AND RESULTS: Six catheters were tested (Biosense Webster Thermocool, Boston Scientific Open irrigated, St. Jude CoolPath, St. Jude CoolPath Duo, Biosense Webster Thermocool SF, St. Jude Cool Flex) at 20 and 35 W power-control, under 2 different blood flows (0.1 and 0.5 m/s) and at 2 target durations (30 and 60 seconds). A total of 601 lesions were made in 26 in vitro preparations. The tip temperature profile showed significant differences between the catheters (P < 0.001) with the Thermocool SF registering the lowest. Only the surface diameter and the depth at maximum diameter of the lesion were influenced by the design of the ablation electrode. The lesion volume did not show significant differences between catheters for any power, application duration or blood flow condition. Char and pops occurred more often at 35 W with only slight differences between the catheters. CONCLUSIONS: Tip design of the 6 different irrigated catheters does not affect the lesion total volume, although a slight difference in lesion geometry in terms of surface diameter and depth at maximum diameter is present. The catheters show a slight different in vitro safety profile.


Asunto(s)
Catéteres Cardíacos , Ablación por Catéter/instrumentación , Ventrículos Cardíacos/cirugía , Irrigación Terapéutica/instrumentación , Animales , Ablación por Catéter/efectos adversos , Diseño de Equipo , Ventrículos Cardíacos/patología , Técnicas In Vitro , Ensayo de Materiales , Modelos Animales , Miocardio/patología , Porcinos , Temperatura , Irrigación Terapéutica/efectos adversos , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA