J Cancer Res Ther ; 11(1): 136-40, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25879351

RESUMEN

AIM OF STUDY: The purpose of this study was to report the dosimetric characteristics of the small fields in flattening filter free (FFF) beams (output measurements, profile analysis, surface dose and consistency) generated by medical linear accelerator and its variation with respect to flattened beams (FB). MATERIALS AND METHODS: Surface doses were obtained for field sizes 1 × 1-40 × 40 cm(2). Field width and penumbra were analyzed for field sizes 1 × 1-40 × 40 cm(2). To take output factors for small fields, diode and micro chamber were used and data was taken at a source-to-surface distance (SSD) and extended SSD. Consistency checked for the dosimetric data for 1 year. RESULTS: Surface doses were higher in FFF compared with FB up to 20 × 20 cm(2) field size. Measured field sizes were slightly lesser in FFF and penumbra values were increased with respect to field size in both FB and FFF. For small fields, diode values have shown more promising results than micro chamber. Small field output measurements at nominal SSD and extended SSD were well in agreement with each other. FFF beams showed good data consistency in 1 year duration. CONCLUSION: Small field dosimetry, surface dose, profile analysis and consistency of FFF beams in FFF photon beams were derived and data shown good consistency during 1 year duration.


Asunto(s)
Aceleradores de Partículas , Radiometría/métodos , Humanos , Dosificación Radioterapéutica
2.
J Med Phys ; 38(3): 143-7, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24049322

RESUMEN

Four dimensional (4D) target localization system (Calypso System) was installed at our hospital, which is equipped with Beacon Transponders, Console, Electromagnetic Array, Optical System, Tracking Station, Treatment table overlay, and Calypso kVue Couch top. The objective of this presentation is to describe the results of commissioning measurements carried out on the Calypso System to verify the manufacturer specifications and also to evolve a quality assurance (QA) procedure which can be used to test its performance routinely. The QA program consists of a series of tests (QA for checking the calibration or system accuracy, Camera Calibration with L-frame fixture, Camera Calibration with T-frame fixture, System calibration Fixture targets test, Localization, and Tracking). These tests were found to be useful to assess the performance of the Calypso System.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA