Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Eur J Nucl Med Mol Imaging ; 43(13): 2374-2380, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27557845

RESUMEN

PURPOSE: To dynamically detect and characterize 18F-fluorodeoxyglucose (FDG) dose infiltrations and evaluate their effects on positron emission tomography (PET) standardized uptake values (SUV) at the injection site and in control tissue. METHODS: Investigational gamma scintillation sensors were topically applied to patients with locally advanced breast cancer scheduled to undergo limited whole-body FDG-PET as part of an ongoing clinical study. Relative to the affected breast, sensors were placed on the contralateral injection arm and ipsilateral control arm during the resting uptake phase prior to each patient's PET scan. Time-activity curves (TACs) from the sensors were integrated at varying intervals (0-10, 0-20, 0-30, 0-40, and 30-40 min) post-FDG and the resulting areas under the curve (AUCs) were compared to SUVs obtained from PET. RESULTS: In cases of infiltration, observed in three sensor recordings (30 %), the injection arm TAC shape varied depending on the extent and severity of infiltration. In two of these cases, TAC characteristics suggested the infiltration was partially resolving prior to image acquisition, although it was still apparent on subsequent PET. Areas under the TAC 0-10 and 0-20 min post-FDG were significantly different in infiltrated versus non-infiltrated cases (Mann-Whitney, p < 0.05). When normalized to control, all TAC integration intervals from the injection arm were significantly correlated with SUVpeak and SUVmax measured over the infiltration site (Spearman ρ ≥ 0.77, p < 0.05). Receiver operating characteristic (ROC) analyses, testing the ability of the first 10 min of post-FDG sensor data to predict infiltration visibility on the ensuing PET, yielded an area under the ROC curve of 0.92. CONCLUSIONS: Topical sensors applied near the injection site provide dynamic information from the time of FDG administration through the uptake period and may be useful in detecting infiltrations regardless of PET image field of view. This dynamic information may also complement the static PET image to better characterize the true extent of infiltrations.


Asunto(s)
Neoplasias de la Mama/metabolismo , Fluorodesoxiglucosa F18/administración & dosificación , Fluorodesoxiglucosa F18/farmacocinética , Radiofármacos/farmacocinética , Conteo por Cintilación/instrumentación , Absorción Fisiológica , Neoplasias de la Mama/diagnóstico por imagen , Sistemas de Computación , Monitoreo de Drogas/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo , Femenino , Humanos , Inyecciones , Tasa de Depuración Metabólica , Dosis de Radiación , Radiofármacos/administración & dosificación , Reproducibilidad de los Resultados , Conteo por Cintilación/métodos , Sensibilidad y Especificidad , Distribución Tisular
2.
J Microelectromech Syst ; 24(3): 634-650, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31814689

RESUMEN

Low-cost modular polymer microfluidic platforms integrating several different functional units may potentially reduce the cost of molecular and environmental analyses, and enable broader applications. Proper function of such systems depends on well-characterized assembly of the instruments. Passive alignment is one approach to obtaining such assemblies. Model modular devices containing passive alignment features, hemispherical pins in v-grooves, and integrated alignment standards for characterizing the accuracy of the assemblies were replicated in polycarbonate using doubled-sided injection molding. The dimensions and locations of the assembly features and alignment standards were measured. The assemblies had mismatches from 16 ± 4 to 20 ± 6 µm along the x-axis and from 103 ± 7 to 118 ± 11 µm along the y-axis. The vertical variation from the nominal value of 287 µm ranged from -10 ± 4 to 34 ± 7 µm. An assembly tolerance model was used to estimate the accuracy of the assemblies based on the manufacturing variations of the alignment structures. Variation of the alignment structure features were propagated through the assembly using Monte Carlo methods. The estimated distributions matched the measured experimental results well, with differences of 2%-13% due to unmodeled aspects of the variations Accurate assembly of advanced polymer microsystems is feasible and predictable in the design phase. [2014-0125].

3.
Electrophoresis ; 34(20-21): 2988-95, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23893860

RESUMEN

Minimizing misalignments during the interconnection of microfluidic modules is extremely critical to develop a fully integrated microfluidic device. Misalignments arising during chip-to-chip or world-to-chip interconnections can be greatly detrimental to efficient functioning of microfluidic devices. To address this problem, we have performed numerical simulations to investigate the effect of misalignments arising in three types of interconnection methods: (i) end-to-end interconnection (ii) channel overlap when chips are stacked on top of each other, and (iii) tube-in-reservoir misalignment occurring due to the offset between the external tubing and the reservoir. For the case of end-to-end interconnection, the effect of misalignment was investigated for 0, 13, 50, 58, and 75% reduction in the available flow area at the location of geometrical misalignment. In the channel overlap interconnection method, various possible misalignment configurations were simulated by maintaining the same amount of misalignment (75% flow area reduction). The effect of misalignment in a tube-in-reservoir interconnection was investigated by positioning the tube at an offset of 164 µm from the reservoir center. All the results were evaluated in terms of the equivalent length of a straight pipe. The effect of Reynolds number (Re) was also taken into account by performing additional simulations of aforementioned cases at Re ranging between 0.075 ≤ Re ≤ 75. Correlations were developed and the results were interpreted in terms of equivalent length (Le ). Equivalent length calculations revealed that the effect of misalignment in tube-in-reservoir interconnection method was the least significant when compared to the other two methods of interconnection.


Asunto(s)
Técnicas Analíticas Microfluídicas/instrumentación , Simulación por Computador , Diseño de Equipo , Modelos Teóricos
4.
Med Phys ; 42(7): 3801-13, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26133582

RESUMEN

PURPOSE: Previous studies have demonstrated how imaging of the breast with patients lying prone using a supportive positioning device markedly facilitates longitudinal and/or multimodal image registration. In this contribution, the authors' primary objective was to determine if there are differences in the standardized uptake value (SUV) derived from [(18)F]fluorodeoxyglucose (18F-FDG) positron emission tomography (PET) in breast tumors imaged in the standard supine position and in the prone position using a specialized positioning device. METHODS: A custom positioning device was constructed to allow for breast scanning in the prone position. Rigid and nonrigid phantom studies evaluated differences in prone and supine PET. Clinical studies comprised 18F-FDG-PET of 34 patients with locally advanced breast cancer imaged in the prone position (with the custom support) followed by imaging in the supine position (without the support). Mean and maximum values (SUVpeak and SUVmax, respectively) were obtained from tumor regions-of-interest for both positions. Prone and supine SUV were linearly corrected to account for the differences in 18F-FDG uptake time. Correlation, Bland-Altman, and nonparametric analyses were performed on uptake time-corrected and uncorrected data. RESULTS: SUV from the rigid PET breast phantom imaged in the prone position with the support device was 1.9% lower than without the support device. In the nonrigid PET breast phantom, prone SUV with the support device was 5.0% lower than supine SUV without the support device. In patients, the median (range) difference in uptake time between prone and supine scans was 16.4 min (13.4-30.9 min), which was significantly-but not completely-reduced by the linear correction method. SUVpeak and SUVmax from prone versus supine scans were highly correlated, with concordance correlation coefficients of 0.91 and 0.90, respectively. Prone SUVpeak and SUVmax were significantly lower than supine in both original and uptake time-adjusted data across a range of index times (P < < 0.0001, Wilcoxon signed rank test). Before correcting for uptake time differences, Bland-Altman analyses revealed proportional bias between prone and supine measurements (SUVpeak and SUVmax) that increased with higher levels of FDG uptake. After uptake time correction, this bias was significantly reduced (P < 0.01). Significant prone-supine differences, with regard to the spatial distribution of lesions relative to isocenter, were observed between the two scan positions, but this was poorly correlated with the residual (uptake time-corrected) prone-supine SUVpeak difference (P = 0.78). CONCLUSIONS: Quantitative 18F-FDG-PET/CT of the breast in the prone position is not deleteriously affected by the support device but yields SUV that is consistently lower than those obtained in the standard supine position. SUV differences between scans arising from FDG uptake time differences can be substantially reduced, but not removed entirely, with the current correction method. SUV from the two scan orientations is quantitatively different and should not be assumed equivalent or interchangeable within the same subject. These findings have clinical relevance in that they underscore the importance of patient positioning while scanning as a clinical variable that must be accounted for with longitudinal PET measurement, for example, in the assessment of treatment response.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Posicionamiento del Paciente/métodos , Tomografía de Emisión de Positrones/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Mama/diagnóstico por imagen , Mama/fisiopatología , Neoplasias de la Mama/tratamiento farmacológico , Neoplasias de la Mama/fisiopatología , Diseño de Equipo , Fluorodesoxiglucosa F18 , Humanos , Estudios Longitudinales , Mamografía/instrumentación , Mamografía/métodos , Persona de Mediana Edad , Modelos Biológicos , Imagen Multimodal/instrumentación , Imagen Multimodal/métodos , Posicionamiento del Paciente/instrumentación , Fantasmas de Imagen , Tomografía de Emisión de Positrones/instrumentación , Posición Prona , Estudios Prospectivos , Radiofármacos , Posición Supina , Tomografía Computarizada por Rayos X/instrumentación
5.
Anal Chim Acta ; 770: 103-10, 2013 Apr 03.
Artículo en Inglés | MEDLINE | ID: mdl-23498692

RESUMEN

This paper presents a numerical study to investigate the effect of geometrical and material transition on the flow and progression of a sample plug in electrokinetic flows. Three cases were investigated: (a) effect of sudden cross-sectional area change (geometrical transition or mismatch) at the interface, (b) effect of only material transition (i.e. varying ζ-potential), and (c) effect of combined material transition and cross-sectional area change at the interface. The geometric transition was quantified based on the ratio of reduced flow area A2 at the mismatch plane to the original cross-sectional area A1. Multiple simulations were performed for varying degrees of area reduction i.e. 0-75% reduction in the available flow area, and the effect of dispersion on the sample plug was quantified by standard metrics. Simulations showed that a 13% combined material and geometrical transition can be tolerated without significant loss of sample resolution. A 6.54% reduction in the flow rates was found between 0% and 75% combined material and geometrical transition.


Asunto(s)
Ensayo de Materiales , Microfluídica , Modelos Biológicos , Técnicas Electroquímicas , Ósmosis , Cemento de Policarboxilato/química , Reacción en Cadena de la Polimerasa , Polimetil Metacrilato/química
6.
Nucl Med Biol ; 40(4): 537-46, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23454249

RESUMEN

INTRODUCTION: Dietary conditions may affect liver [(18)F]FDG kinetics due to arterial and portal vein (PV) input. The purpose of this study was to evaluate kinetic models of [(18)F]FDG metabolism under a wide range of dietary interventions taking into account variations in arterial (HA) and portal vein (PV) input. METHODS: The study consisted of three groups of rats maintained under different diet interventions: 12 h fasted, 24 h fasted and those fed with high fructose diet. [(15)O]H2O PET imaging was used to characterize liver flow contribution from HA and PV to the liver's dual input function (DIF). [(18)F]FDG PET imaging was used to characterize liver metabolism. Differences in [(18)F]FDG kinetics in HA, PV and liver under different diet interventions were investigated. An arterial to PV Transfer Function (TF) was optimized in all three dietary states to noninvasively estimate PV activity. Finally, two compartment 3-parameter (2C3P), two compartment 4-parameter (2C4P), two compartment 5-parameter (2C5P), and three compartment 5-parameter (3C5P) models were evaluated and compared to describe the kinetics of [(18)F]FDG in the liver across diet interventions. Sensitivity of the compartmental models to ratios of HA to PV flow fractions was further investigated. RESULTS: Differences were found in HA and PV [(18)F]FDG kinetics across 12h fasted, 24h fasted and high fructose fed diet interventions. A two exponential TF model was able to estimate portal activity in all the three diet interventions. Statistical analysis suggests that a 2C3P model configuration was adequate to describe the kinetics of [(18)F]FDG in the liver under wide ranging dietary interventions. The net influx of [(18)F]FDG was lowest in the 12h fasted group, followed by 24 h fasted group, and high fructose diet. CONCLUSIONS: A TF was optimized to non-invasively estimate PV time activity curve in different dietary states. Several kinetic models were assessed and a 2C3P model was sufficient to describe [(18)F]FDG liver kinetics despite differences in HA and PV kinetics across wide ranging dietary interventions. The observations have broader implications for the quantification of liver metabolism in metabolic disorders and cancer, among others.


Asunto(s)
Arterias/fisiología , Dieta , Fluorodesoxiglucosa F18/metabolismo , Hígado/irrigación sanguínea , Hígado/metabolismo , Vena Porta/fisiología , Animales , Cinética , Hígado/fisiología , Masculino , Modelos Biológicos , Ratas , Ratas Zucker
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA