Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Eur Respir J ; 46(4): 988-1000, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26022965

RESUMEN

No current patient-centred instrument captures all dimensions of physical activity in chronic obstructive pulmonary disease (COPD). Our objective was item reduction and initial validation of two instruments to measure physical activity in COPD.Physical activity was assessed in a 6-week, randomised, two-way cross-over, multicentre study using PROactive draft questionnaires (daily and clinical visit versions) and two activity monitors. Item reduction followed an iterative process including classical and Rasch model analyses, and input from patients and clinical experts.236 COPD patients from five European centres were included. Results indicated the concept of physical activity in COPD had two domains, labelled "amount" and "difficulty". After item reduction, the daily PROactive instrument comprised nine items and the clinical visit contained 14. Both demonstrated good model fit (person separation index >0.7). Confirmatory factor analysis supported the bidimensional structure. Both instruments had good internal consistency (Cronbach's α>0.8), test-retest reliability (intraclass correlation coefficient ≥0.9) and exhibited moderate-to-high correlations (r>0.6) with related constructs and very low correlations (r<0.3) with unrelated constructs, providing evidence for construct validity.Daily and clinical visit "PROactive physical activity in COPD" instruments are hybrid tools combining a short patient-reported outcome questionnaire and two activity monitor variables which provide simple, valid and reliable measures of physical activity in COPD patients.


Asunto(s)
Actividad Motora , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Enfermedad Pulmonar Obstructiva Crónica/terapia , Anciano , Algoritmos , Estudios Cruzados , Europa (Continente) , Análisis Factorial , Femenino , Humanos , Masculino , Persona de Mediana Edad , Psicometría/métodos , Calidad de Vida , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad , Encuestas y Cuestionarios
2.
Thorax ; 69(8): 731-9, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24558112

RESUMEN

BACKGROUND: The relationship between physical activity, disease severity, health status and prognosis in patients with COPD has not been systematically assessed. Our aim was to identify and summarise studies assessing associations between physical activity and its determinants and/or outcomes in patients with COPD and to develop a conceptual model for physical activity in COPD. METHODS: We conducted a systematic search of four databases (Medline, Embase, CINAHL and Psychinfo) prior to November 2012. Teams of two reviewers independently selected articles, extracted data and used the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) to assess quality of evidence. RESULTS: 86 studies were included: 59 were focused on determinants, 23 on outcomes and 4 on both. Hyperinflation, exercise capacity, dyspnoea, previous exacerbations, gas exchange, systemic inflammation, quality of life and self-efficacy were consistently related to physical activity, but often based on cross-sectional studies and low-quality evidence. Results from studies of pharmacological and non-pharmacological treatments were inconsistent and the quality of evidence was low to very low. As outcomes, COPD exacerbations and mortality were consistently associated with low levels of physical activity based on moderate quality evidence. Physical activity was associated with other outcomes such as dyspnoea, health-related quality of life, exercise capacity and FEV1 but based on cross-sectional studies and low to very low quality evidence. CONCLUSIONS: Physical activity level in COPD is consistently associated with mortality and exacerbations, but there is poor evidence about determinants of physical activity, including the impact of treatment.


Asunto(s)
Actividad Motora , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Humanos , Pronóstico , Enfermedad Pulmonar Obstructiva Crónica/tratamiento farmacológico , Enfermedad Pulmonar Obstructiva Crónica/mortalidad , Calidad de Vida
3.
Eur Respir J ; 42(5): 1205-15, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23397303

RESUMEN

Symptoms during physical activity and physical inactivity are hallmarks of chronic obstructive pulmonary disease (COPD). Our aim was to evaluate the validity and usability of six activity monitors in patients with COPD against the doubly labelled water (DLW) indirect calorimetry method. 80 COPD patients (mean ± sd age 68 ± 6 years and forced expiratory volume in 1 s 57 ± 19% predicted) recruited in four centres each wore simultaneously three or four out of six commercially available monitors validated in chronic conditions for 14 consecutive days. A priori validity criteria were defined. These included the ability to explain total energy expenditure (TEE) variance through multiple regression analysis, using TEE as the dependent variable with total body water (TBW) plus several physical activity monitor outputs as independent variables; and correlation with activity energy expenditure (AEE) measured by DLW. The Actigraph GT3X (Actigraph LLC, Pensacola, FL, USA), and DynaPort MoveMonitor (McRoberts BV, The Hague, the Netherlands) best explained the majority of the TEE variance not explained by TBW (53% and 70%, respectively) and showed the most significant correlations with AEE (r=0.71, p<0.001 and r=0.70, p<0.0001, respectively). The results of this study should guide users in choosing valid activity monitors for research or for clinical use in patients with chronic diseases such as COPD.


Asunto(s)
Actividades Cotidianas , Monitoreo Ambulatorio/instrumentación , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Actigrafía , Anciano , Antropometría , Agua Corporal , Calorimetría Indirecta/instrumentación , Estudios Transversales , Metabolismo Energético , Europa (Continente) , Femenino , Humanos , Masculino , Persona de Mediana Edad , Actividad Motora , Consumo de Oxígeno , Análisis de Regresión , Encuestas y Cuestionarios
4.
Int J Behav Nutr Phys Act ; 9: 84, 2012 Jul 09.
Artículo en Inglés | MEDLINE | ID: mdl-22776399

RESUMEN

The assessment of physical activity in healthy populations and in those with chronic diseases is challenging. The aim of this systematic review was to identify whether available activity monitors (AM) have been appropriately validated for use in assessing physical activity in these groups. Following a systematic literature search we found 134 papers meeting the inclusion criteria; 40 conducted in a field setting (validation against doubly labelled water), 86 in a laboratory setting (validation against a metabolic cart, metabolic chamber) and 8 in a field and laboratory setting. Correlation coefficients between AM outcomes and energy expenditure (EE) by the criterion method (doubly labelled water and metabolic cart/chamber) and percentage mean differences between EE estimation from the monitor and EE measurement by the criterion method were extracted. Random-effects meta-analyses were performed to pool the results across studies where possible. Types of devices were compared using meta-regression analyses. Most validation studies had been performed in healthy adults (n=118), with few carried out in patients with chronic diseases (n=16). For total EE, correlation coefficients were statistically significantly lower in uniaxial compared to multisensor devices. For active EE, correlations were slightly but not significantly lower in uniaxial compared to triaxial and multisensor devices. Uniaxial devices tended to underestimate TEE (-12.07 (95%CI; -18.28 to -5.85) %) compared to triaxial (-6.85 (95%CI; -18.20 to 4.49) %, p=0.37) and were statistically significantly less accurate than multisensor devices (-3.64 (95%CI; -8.97 to 1.70) %, p<0.001). TEE was underestimated during slow walking speeds in 69% of the lab validation studies compared to 37%, 30% and 37% of the studies during intermediate, fast walking speed and running, respectively. The high level of heterogeneity in the validation studies is only partly explained by the type of activity monitor and the activity monitor outcome. Triaxial and multisensor devices tend to be more valid monitors. Since activity monitors are less accurate at slow walking speeds and information about validated activity monitors in chronic disease populations is lacking, proper validation studies in these populations are needed prior to their inclusion in clinical trials.


Asunto(s)
Monitoreo Fisiológico/instrumentación , Monitoreo Fisiológico/métodos , Actividad Motora , Enfermedad Crónica , Bases de Datos Factuales , Metabolismo Energético , Prueba de Esfuerzo/instrumentación , Prueba de Esfuerzo/métodos , Humanos , Carrera
5.
Future Healthc J ; 8(2): e302-e306, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34286203

RESUMEN

INTRODUCTION: One-hundred and forty patients at Croydon University Hospital received continuous positive airway pressure (CPAP) on a specialist respiratory ward, as a bridge to invasive mechanical ventilation (IMV) or as a ceiling of care for COVID-19. This retrospective study aimed to outline service expansion, patient characteristics and explore risk factors in outcomes. RESULTS: Mean age of patients on CPAP was 64 years (standard deviation 12). The median number of days from admission to CPAP initiation was 1 day (interquartile range (IQR) 0-3), and time before successful wean off CPAP was 4 days (IQR 2-6). Twenty-eight-day mortality was 64%. Thirty-four per cent of patients went onto require IMV, 24% improved off CPAP and 41% were palliated. The 28-day non-survivor group were of older age, had statistically significant higher admission creatinine and higher peak oxygen requirement. Age above 65 years was associated with higher mortality (odds ratio 5.9; 95% confidence interval 2.63-13.3). CONCLUSION: CPAP is a viable ceiling-of-treatment option in those unsuitable for ventilation, and may even avoid the need for ventilation in others. Duration on CPAP may be useful for service provision to predict resource allocation. The rapidity from admission to CPAP initiation highlights the need for early ceilings of care to be established.

7.
Int J Chron Obstruct Pulmon Dis ; 14: 1979-1992, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31564846

RESUMEN

Purpose: Longitudinal data on the effect of time and environmental conditions on physical activity (PA) among COPD patients are currently scarce, but this is an important factor in the design of trials to test interventions that might impact on it. Thus, we aimed to assess the effect of time and climate conditions (temperature, day length and rainfall) on progression of PA in a cohort of COPD patients. Patients and methods: This is a prospective, multicenter, cohort study undertaken as part of the EU/IMI PROactive project, in which we assessed 236 COPD patients simultaneously wearing two activity monitors (Dynaport MiniMod and Actigraph GT3X). A multivariable generalized linear model analysis was conducted to describe the effect of the explanatory variables on PA measures, over three time points (baseline, 6 and 12 months). Results: At 12 months (n=157; FEV1% predicted=57.7±21.9) there was a significant reduction in all PA measures (Actigraph step count (4284±3533 vs 3533±293)), Actigraph moderate- to vigorous-intensity PA ratio (8.8 (18.8) vs 6.1 (15.7)), Actigraph vector magnitude units (374,902.4 (265,269) vs 336,240 (214,432)), MiniMod walking time (59.1 (34.9) vs 56.9 (38.7) mins) and MiniMod PA intensity (0.183 (0) vs 0.181 (0)). Time had a significant, negative effect on most PA measures in multivariable analysis, after correcting for climate factors, study center, age, FEV1% predicted, 6MWD and other disease severity measures. Rainfall was the only climate factor with a negative effect on most PA parameters. Conclusion: COPD patients demonstrate a significant decrease in PA over 1 year follow-up, which is further affected by hours of rainfall, but not by other climate considerations.


Asunto(s)
Clima , Tolerancia al Ejercicio/fisiología , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Conducta Sedentaria , Caminata/fisiología , Anciano , Progresión de la Enfermedad , Femenino , Monitores de Ejercicio , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Pruebas de Función Respiratoria , Factores de Tiempo
9.
PLoS One ; 7(6): e39198, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22745715

RESUMEN

Reduced physical activity is an important feature of Chronic Obstructive Pulmonary Disease (COPD). Various activity monitors are available but their validity is poorly established. The aim was to evaluate the validity of six monitors in patients with COPD. We hypothesized triaxial monitors to be more valid compared to uniaxial monitors. Thirty-nine patients (age 68±7 years, FEV(1) 54±18%predicted) performed a one-hour standardized activity protocol. Patients wore 6 monitors (Kenz Lifecorder (Kenz), Actiwatch, RT3, Actigraph GT3X (Actigraph), Dynaport MiniMod (MiniMod), and SenseWear Armband (SenseWear)) as well as a portable metabolic system (Oxycon Mobile). Validity was evaluated by correlation analysis between indirect calorimetry (VO(2)) and the monitor outputs: Metabolic Equivalent of Task [METs] (SenseWear, MiniMod), activity counts (Actiwatch), vector magnitude units (Actigraph, RT3) and arbitrary units (Kenz) over the whole protocol and slow versus fast walking. Minute-by-minute correlations were highest for the MiniMod (r = 0.82), Actigraph (r = 0.79), SenseWear (r = 0.73) and RT3 (r = 0.73). Over the whole protocol, the mean correlations were best for the SenseWear (r = 0.76), Kenz (r = 0.52), Actigraph (r = 0.49) and MiniMod (r = 0.45). The MiniMod (r = 0.94) and Actigraph (r = 0.88) performed better in detecting different walking speeds. The Dynaport MiniMod, Actigraph GT3X and SenseWear Armband (all triaxial monitors) are the most valid monitors during standardized physical activities. The Dynaport MiniMod and Actigraph GT3X discriminate best between different walking speeds.


Asunto(s)
Calorimetría Indirecta/métodos , Monitoreo Ambulatorio/métodos , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Calidad de Vida , Encuestas y Cuestionarios , Caminata/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA