Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 74
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Proc Natl Acad Sci U S A ; 119(22): e2117675119, 2022 05 31.
Artículo en Inglés | MEDLINE | ID: mdl-35613056

RESUMEN

Fibrin is the fibrous protein network that comprises blood clots; it is uniquely capable of bearing very large tensile strains (up to 200%) due to multiscale force accommodation mechanisms. Fibrin is also a biochemical scaffold for numerous enzymes and blood factors. The biomechanics and biochemistry of fibrin have been independently studied. However, comparatively little is known about how fibrin biomechanics and biochemistry are coupled: how does fibrin deformation influence its biochemistry? In this study, we show that mechanically induced protein structural changes in fibrin affect fibrin biochemistry. We find that tensile deformation of fibrin leads to molecular structural transitions of α-helices to ß-sheets, which reduced binding of tissue plasminogen activator (tPA), an enzyme that initiates fibrin lysis. Moreover, binding of tPA and Thioflavin T, a commonly used ß-sheet marker, were mutually exclusive, further demonstrating the mechano-chemical control of fibrin biochemistry. Finally, we demonstrate that structural changes in fibrin suppressed the biological activity of platelets on mechanically strained fibrin due to reduced αIIbß3 integrin binding. Our work shows that mechanical strain regulates fibrin molecular structure and biological activity in an elegant mechano-chemical feedback loop, which possibly extends to other fibrous biopolymers.


Asunto(s)
Fibrina , Estrés Mecánico , Resistencia a la Tracción , Benzotiazoles/química , Fibrina/química , Humanos , Unión Proteica , Conformación Proteica en Hélice alfa , Conformación Proteica en Lámina beta , Activador de Tejido Plasminógeno/química
2.
Cancer Cell Int ; 24(1): 199, 2024 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-38840117

RESUMEN

The extracellular matrix (ECM) is a dynamic and complex microenvironment that modulates cell behavior and cell fate. Changes in ECM composition and architecture have been correlated with development, differentiation, and disease progression in various pathologies, including breast cancer [1]. Studies have shown that aligned fibers drive a pro-metastatic microenvironment, promoting the transformation of mammary epithelial cells into invasive ductal carcinoma via the epithelial-to-mesenchymal transition (EMT) [2]. The impact of ECM orientation on breast cancer metabolism, however, is largely unknown. Here, we employ two non-invasive imaging techniques, fluorescence-lifetime imaging microscopy (FLIM) and intensity-based multiphoton microscopy, to assess the metabolic states of cancer cells cultured on ECM-mimicking nanofibers in a random and aligned orientation. By tracking the changes in the intrinsic fluorescence of nicotinamide adenine dinucleotide and flavin adenine dinucleotide, as well as expression levels of metastatic markers, we reveal how ECM fiber orientation alters cancer metabolism and EMT progression. Our study indicates that aligned cellular microenvironments play a key role in promoting metastatic phenotypes of breast cancer as evidenced by a more glycolytic metabolic signature on nanofiber scaffolds of aligned orientation compared to scaffolds of random orientation. This finding is particularly relevant for subsets of breast cancer marked by high levels of collagen remodeling (e.g. pregnancy associated breast cancer), and may serve as a platform for predicting clinical outcomes within these subsets [3-6].

3.
Soft Matter ; 19(35): 6710-6720, 2023 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-37622379

RESUMEN

Nano-indentation is a promising method to identify the constitutive parameters of soft materials, including soft tissues. Especially when materials are very small and heterogeneous, nano-indentation allows mechanical interrogation where traditional methods may fail. However, because nano-indentation does not yield a homogeneous deformation field, interpreting the resulting load-displacement curves is non-trivial and most investigators resort to simplified approaches based on the Hertzian solution. Unfortunately, for small samples and large indentation depths, these solutions are inaccurate. We set out to use machine learning to provide an alternative strategy. We first used the finite element method to create a large synthetic data set. We then used these data to train neural networks to inversely identify material parameters from load-displacement curves. To this end, we took two different approaches. First, we learned the indentation forward problem, which we then applied within an iterative framework to identify material parameters. Second, we learned the inverse problem of directly identifying material parameters. We show that both approaches are effective at identifying the parameters of the neo-Hookean and Gent models. Specifically, when applied to synthetic data, our approaches are accurate even for small sample sizes and at deep indentation. Additionally, our approaches are fast, especially compared to the inverse finite element approach. Finally, our approaches worked on unseen experimental data from thin mouse brain samples. Here, our approaches proved robust to experimental noise across over 1000 samples. By providing open access to our data and code, we hope to support others that conduct nano-indentation on soft materials.


Asunto(s)
Aprendizaje Automático , Nanotecnología , Redes Neurales de la Computación
4.
Finite Elem Anal Des ; 2132023 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-37168239

RESUMEN

Augmented reality (AR) has revolutionized the video game industry by providing interactive, three-dimensional visualization. Interestingly, AR technology has only been sparsely used in scientific visualization. This is, at least in part, due to the significant technical challenges previously associated with creating and accessing such models. To ease access to AR for the scientific community, we introduce a novel visualization pipeline with which they can create and render AR models. We demonstrate our pipeline by means of finite element results, but note that our pipeline is generally applicable to data that may be represented through meshed surfaces. Specifically, we use two open-source software packages, ParaView and Blender. The models are then rendered through the platform, which we access through Android and iOS smartphones. To demonstrate our pipeline, we build AR models from static and time-series results of finite element simulations discretized with continuum, shell, and beam elements. Moreover, we openly provide python scripts to automate this process. Thus, others may use our framework to create and render AR models for their own research and teaching activities.

5.
Philos Trans A Math Phys Eng Sci ; 380(2234): 20210365, 2022 Oct 17.
Artículo en Inglés | MEDLINE | ID: mdl-36031838

RESUMEN

Constitutive models are important to biomechanics for two key reasons. First, constitutive modelling is an essential component of characterizing tissues' mechanical properties for informing theoretical and computational models of biomechanical systems. Second, constitutive models can be used as a theoretical framework for extracting and comparing key quantities of interest from material characterization experiments. Over the past five decades, the Ogden model has emerged as a popular constitutive model in soft tissue biomechanics with relevance to both informing theoretical and computational models and to comparing material characterization experiments. The goal of this short review is threefold. First, we will discuss the broad relevance of the Ogden model to soft tissue biomechanics and the general characteristics of soft tissues that are suitable for approximating with the Ogden model. Second, we will highlight exemplary uses of the Ogden model in brain tissue, blood clot and other tissues. Finally, we offer a tutorial on fitting the one-term Ogden model to pure shear experimental data via both an analytical approximation of homogeneous deformation and a finite-element model of the tissue domain. Overall, we anticipate that this short review will serve as a practical introduction to the use of the Ogden model in biomechanics. This article is part of the theme issue 'The Ogden model of rubber mechanics: Fifty years of impact on nonlinear elasticity'.


Asunto(s)
Encéfalo , Modelos Biológicos , Fenómenos Biomecánicos , Elasticidad , Análisis de Elementos Finitos , Estrés Mecánico
6.
Soft Matter ; 16(43): 9908-9916, 2020 Nov 21.
Artículo en Inglés | MEDLINE | ID: mdl-33029598

RESUMEN

When a thrombus breaks off and embolizes it can occlude vital vessels such as those of the heart, lung, or brain. These thromboembolic conditions are responsible for 1 in 4 deaths worldwide. Thrombus resistance to embolization is driven by its intrinsic fracture toughness as well as other, non-surface-creating dissipative mechanisms. In our current work, we identify and quantify these latter mechanisms toward future studies that aim to delineate fracture from other forms of dissipation. To this end, we use an in vitro thrombus mimic system to produce whole blood clots and explore their dissipative mechanics under simple uniaxial extension, cyclic loading, and stress-relaxation. We found that whole blood clots exhibit Mullins-like effect, hysteresis, permanent set, strain-rate dependence, and nonlinear stress-relaxation. Interestingly, we found that performing these tests under dry or submerged conditions did not change our results. However, performing these tests under room temperature or body temperature conditions yielded differences. Importantly, because we use venous blood our work is most closely related to venous in vivo blood clots. Overall, we have demonstrated that whole blood clots show several dissipative phenomena - similarly to hydrogels - that will be critical to our understanding of thrombus embolization.


Asunto(s)
Trombosis , Coagulación Sanguínea , Encéfalo , Humanos
7.
J Mech Phys Solids ; 63: 128-140, 2014 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-24563551

RESUMEN

Despite their seemingly delicate appearance, thin biological membranes fulfill various crucial roles in the human body and can sustain substantial mechanical loads. Unlike engineering structures, biological membranes are able to grow and adapt to changes in their mechanical environment. Finite element modeling of biological growth holds the potential to better understand the interplay of membrane form and function and to reliably predict the effects of disease or medical intervention. However, standard continuum elements typically fail to represent thin biological membranes efficiently, accurately, and robustly. Moreover, continuum models are typically cumbersome to generate from surface-based medical imaging data. Here we propose a computational model for finite membrane growth using a classical midsurface representation compatible with standard shell elements. By assuming elastic incompressibility and membrane-only growth, the model a priori satisfies the zero-normal stress condition. To demonstrate its modular nature, we implement the membrane growth model into the general-purpose non-linear finite element package Abaqus/Standard using the concept of user subroutines. To probe efficiently and robustness, we simulate selected benchmark examples of growing biological membranes under different loading conditions. To demonstrate the clinical potential, we simulate the functional adaptation of a heart valve leaflet in ischemic cardiomyopathy. We believe that our novel approach will be widely applicable to simulate the adaptive chronic growth of thin biological structures including skin membranes, mucous membranes, fetal membranes, tympanic membranes, corneoscleral membranes, and heart valve membranes. Ultimately, our model can be used to identify diseased states, predict disease evolution, and guide the design of interventional or pharmaceutic therapies to arrest or revert disease progression.

8.
Biomech Model Mechanobiol ; 23(2): 553-568, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38129671

RESUMEN

The skin is the largest organ in the human body and serves various functions, including mechanical protection and mechanosensation. Yet, even though skin's biomechanics are attributed to two main layers-epidermis and dermis-computational models have often treated this tissue as a thin homogeneous material or, when considering multiple layers, have ignored the most prominent heterogeneities of skin seen at the mesoscale. Here, we create finite element models of representative volume elements (RVEs) of skin, including the three-dimensional variation of the interface between the epidermis and dermis as well as considering the presence of hair follicles. The sinusoidal interface, which approximates the anatomical features known as Rete ridges, does not affect the homogenized mechanical response of the RVE but contributes to stress concentration, particularly at the valleys of the Rete ridges. The stress profile is three-dimensional due to the skin's anisotropy, leading to high-stress bands connecting the valleys of the Rete ridges through one type of saddle point. The peaks of the Rete ridges and the other class of saddle points of the sinusoidal surface form a second set of low-stress bands under equi-biaxial loading. Another prominent feature of the heterogeneous stress pattern is a switch in the stress jump across the interface, which becomes lower with respect to the flat interface at increasing deformations. These features are seen in both tension and shear loading. The RVE with the hair follicle showed strains concentrating at the epidermis adjacent to the hair follicle, the epithelial tissue surrounding the hair right below the epidermis, and the bulb or base region of the hair follicle. The regions of strain concentration near the hair follicle in equi-biaxial and shear loading align with the presence of distinct mechanoreceptors in the skin, except for the bulb or base region. This study highlights the importance of skin heterogeneities, particularly its potential mechanophysiological role in the sense of touch and the prevention of skin delamination.


Asunto(s)
Epidermis , Piel , Humanos , Folículo Piloso , Fenómenos Biomecánicos
9.
J Biomed Mater Res A ; 2024 Aug 29.
Artículo en Inglés | MEDLINE | ID: mdl-39210577

RESUMEN

Tissue mimicking materials are designed to represent real tissue in applications such as medical device testing and surgical training. Thanks to progress in 3D-printing technology, tissue mimics can now be easily cast into arbitrary geometries and manufactured with adjustable material properties to mimic a wide variety of tissue types. However, it is unclear how well 3D-printable mimics represent real tissues and their mechanics. The objective of this work is to fill this knowledge gap using the Stratasys Digital Anatomy 3D-Printer as an example. To this end, we created mimics of biological tissues we previously tested in our laboratory: blood clots, myocardium, and tricuspid valve leaflets. We printed each tissue mimic to have the identical geometry to its biological counterpart and tested the samples using identical protocols. In our evaluation, we focused on the stiffness of the tissues and their fracture toughness in the case of blood clots. We found that the mechanical behavior of the tissue mimics often differed substantially from the biological tissues they aim to represent. Qualitatively, tissue mimics failed to replicate the traditional strain-stiffening behavior of soft tissues. Quantitatively, tissue mimics were stiffer than their biological counterparts, especially at small strains, in some cases by orders of magnitude. In those materials in which we tested toughness, we found that tissue mimicking materials were also much tougher than their biological counterparts. Thus, our work highlights limitations of at least one 3D-printing technology in its ability to mimic the mechanical properties of biological tissues. Therefore, care should be taken when using this technology, especially where tissue mimicking materials are expected to represent soft tissue properties quantitatively. Whether other technologies fare better remains to be seen.

10.
Artículo en Inglés | MEDLINE | ID: mdl-38771453

RESUMEN

PURPOSE: One in four deaths worldwide is due to thromboembolic disease; that is, one in four people die from blood clots first forming and then breaking off or embolizing. Once broken off, clots travel downstream, where they occlude vital blood vessels such as those of the brain, heart, or lungs, leading to strokes, heart attacks, or pulmonary embolisms, respectively. Despite clots' obvious importance, much remains to be understood about clotting and clot embolization. In our work, we take a first step toward untangling the mystery behind clot embolization and try to answer the simple question: "What makes blood clots break off?" METHODS: To this end, we conducted experimentally-informed, back-of-the-envelope computations combining fracture mechanics and phase-field modeling. We also focused on deep venous clots as our model problem. RESULTS: Here, we show that of the three general forces that act on venous blood clots-shear stress, blood pressure, and wall stretch-induced interfacial forces-the latter may be a critical embolization force in occlusive and non-occlusive clots, while blood pressure appears to play a determinant role only for occlusive clots. Contrary to intuition and prior reports, shear stress, even when severely elevated, appears unlikely to cause embolization. CONCLUSION: This first approach to understanding the source of blood clot bulk fracture may be a critical starting point for understanding blood clot embolization. We hope to inspire future work that will build on ours and overcome the limitations of these back-of-the-envelope computations.

11.
J Mech Behav Biomed Mater ; 152: 106453, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38335648

RESUMEN

Tricuspid valve leaflets have historically been considered "passive flaps". However, we have recently shown that tricuspid leaflets actively remodel in sheep with functional tricuspid regurgitation. We hypothesize that these remodeling-induced changes reduce leaflet coaptation and, therefore, contribute to valvular dysfunction. To test this, we simulated the impact of remodeling-induced changes on valve mechanics in a reverse-engineered computer model of the human tricuspid valve. To this end, we combined right-heart pressures and tricuspid annular dynamics recorded in an ex vivo beating heart, with subject-matched in vitro measurements of valve geometry and material properties, to build a subject-specific finite element model. Next, we modified the annular geometry and boundary conditions to mimic changes seen in patients with pulmonary hypertension. In this model, we then increased leaflet thickness and stiffness and reduced the stretch at which leaflets stiffen, which we call "transition-λ." Subsequently, we quantified mean leaflet stresses, leaflet systolic angles, and coaptation area as measures of valve function. We found that leaflet stresses, leaflet systolic angle, and coaptation area are sensitive to independent changes in stiffness, thickness, and transition-λ. When combining thickening, stiffening, and changes in transition-λ, we found that anterior and posterior leaflet stresses decreased by 26% and 28%, respectively. Furthermore, systolic angles increased by 43%, and coaptation area decreased by 66%; thereby impeding valve function. While only a computational study, we provide the first evidence that remodeling-induced leaflet thickening and stiffening may contribute to valvular dysfunction. Targeted suppression of such changes in diseased valves could restore normal valve mechanics and promote leaflet coaptation.


Asunto(s)
Hipertensión Pulmonar , Válvula Tricúspide , Humanos , Animales , Ovinos , Catéteres , Simulación por Computador , Presión
12.
Acta Biomater ; 175: 106-113, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38042263

RESUMEN

Skin aging is of immense societal and, thus, scientific interest. Because mechanics play a critical role in skin's function, a plethora of studies have investigated age-induced changes in skin mechanics. Nonetheless, much remains to be learned about the mechanics of aging skin. This is especially true when considering sex as a biological variable. In our work, we set out to answer some of these questions using mice as a model system. Specifically, we combined mechanical testing, histology, collagen assays, and two-photon microscopy to identify age- and sex-dependent changes in skin mechanics and to relate them to structural, microstructural, and compositional factors. Our work revealed that skin stiffness, thickness, and collagen content all decreased with age and were sex dependent. Interestingly, sex differences in stiffness were age induced. We hope our findings not only further our fundamental understanding of skin aging but also highlight both age and sex as important variables when conducting studies on skin mechanics. STATEMENT OF SIGNIFICANCE: Our work addresses the question, "How do sex and age affect the mechanics of skin?" Answering this question is of both scientific and societal importance. We do so in mice as a model system. Thereby, we hope to add clarity to a body of literature that appears divided on the effect of both factors. Our findings have important implications for those studying age and sex differences, especially in mice as a model system.


Asunto(s)
Envejecimiento de la Piel , Femenino , Ratones , Masculino , Animales , Colágeno/química , Piel , Pruebas Mecánicas
13.
J Mech Behav Biomed Mater ; 154: 106508, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38513312

RESUMEN

Thromboembolism - that is, clot formation and the subsequent fragmentation of clot - is a leading cause of death worldwide. Clots' mechanical properties are critical determinants of both the embolization process and the pathophysiological consequences thereof. Thus, understanding and quantifying the mechanical properties of clots is important to our ability to treat and prevent thromboembolic disease. However, assessing these properties from in vivo clots is experimentally challenging. Therefore, we and others have turned to studying in vitro clot mimics instead. Unfortunately, there are significant discrepancies in the reported properties of these clot mimics, which have been hypothesized to arise from differences in experimental techniques and blood sources. The goal of our current work is therefore to compare the mechanical behavior of clots made from the two most common sources, human and bovine blood, using the same experimental techniques. To this end, we tested clots under pure shear with and without initial cracks, under cyclic loading, and under stress relaxation. Based on these data, we computed and compared stiffness, strength, work-to-rupture, fracture toughness, relaxation time constants, and prestrain. While clots from both sources behaved qualitatively similarly, they differed quantitatively in almost every metric. We also correlated each mechanical metric to measures of blood composition. Thereby, we traced this inter-species variability in clot mechanics back to significant differences in hematocrit, but not platelet count. Thus, our work suggests that the results of past studies that have used bovine blood to make in vitro mimics - without adjusting blood composition - should be interpreted carefully. Future studies about the mechanical properties of blood clots should focus on human blood alone.


Asunto(s)
Tromboembolia , Trombosis , Humanos , Animales , Bovinos
14.
JTCVS Open ; 17: 111-120, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38420560

RESUMEN

Background: Tricuspid valve disease significantly affects 1.6 million Americans. The gold standard treatment for tricuspid disease is the implantation of annuloplasty devices. These ring-like devices come in various shapes and sizes. Choices for both shape and size are most often made by surgical intuition rather than scientific rationale. Methods: To understand the impact of shape and size on valve mechanics and to provide a rational basis for their selection, we used a subject-specific finite element model to conduct a virtual case study. That is, we implanted 4 different annuloplasty devices of 6 different sizes in our virtual patient. After each virtual surgery, we computed the coaptation area, leaflet end-systolic angles, leaflet stress, and chordal forces. Results: We found that contoured devices are better at normalizing end-systolic angles, whereas the one flat device, the Edwards Classic, maximized the coaptation area and minimized leaflet stress and chordal forces. We further found that reducing device size led to increased coaptation area but also negatively impacted end-systolic angles, stress, and chordal forces. Conclusions: Based on our analyses of the coaptation area, leaflet motion, leaflet stress, and chordal forces, we found that device shape and size have a significant impact on valve mechanics. Thereby, our study also demonstrates the value of simulation tools and device tests in "virtual patients." Expanding our study to many more valves may, in the future, allow for universal recommendations.

15.
Data Brief ; 52: 110051, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38299102

RESUMEN

Tricuspid valve annuloplasty is the gold standard surgical treatment for functional tricuspid valve regurgitation. During this procedure, ring-like devices are implanted to reshape the diseased tricuspid valve annulus and to restore function. For the procedure, surgeons can choose from multiple available device options varying in shape and size. In this article, we provide the three-dimensional (3D) scanned geometry (*.stl) and reduced midline (*.vtk) of five different annuloplasty devices of all commercially available sizes. Three-dimensional images were captured using a 3D scanner. After extracting the surface geometry from these images, the images were converted to 3D point clouds and skeletonized to generate a 3D midline of each device. In total, we provide 30 data sets comprising the Edwards Classic, Edwards MC3, Edwards Physio, Medtronic TriAd, and Medtronic Contour 3D of sizes 26-36. This dataset can be used in computational models of tricuspid valve annuloplasty repair to inform accurate repair geometry and boundary conditions. Additionally, others can use these data to compare and inspire new device shapes and sizes.

16.
Artículo en Inglés | MEDLINE | ID: mdl-38830034

RESUMEN

OBJECTIVES: Severe functional tricuspid regurgitation (FTR) is associated with subvalvular remodelling, but leaflet tissue alterations may also contribute. We set out to investigate molecular mechanisms driving leaflet remodelling in chronic ovine FTR. METHODS: Thirteen adult sheep (55 ± 4kg) underwent left thoracotomy, epicardial echocardiography, and pulmonary artery banding (PAB) to induce right heart failure and FTR. After 16 weeks, 13 banded (FTR) and 12 control (CTL) animals underwent median sternotomy for epicardial echocardiography and were subsequently sacrificed with each tricuspid leaflet tissue harvested for RNA-seq and histology. RESULTS: After 16 weeks, 7 animals developed severe, 2 moderate, and 4 mild tricuspid regurgitation (TR). Relative to CTL, FTR animals had increased PAP, TR, tricuspid annular diameter, and right atrial volume, while tricuspid annular plane systolic excursion (TAPSE) and RV fractional area change decreased. FTR leaflets exhibited altered constituents and an increase in cellularity. RNA-seq identified 85 significantly differentially expressed genes (DEG) with 17, 53, and 127 within the anterior, posterior, and septal leaflets respectively. RRM2, PRG4, and CXCL8 (IL-8) were identified as DEGs across all leaflets and CXCL8 was differentially expressed between FTR severity grades. RRM2, PRG4, and CXCL8 significantly correlated with TAPSE, and this correlation was consistent regardless of the anatomical location of the leaflet. CONCLUSIONS: PAB in our ovine model resulted in RV failure and FTR. Leaflet RNA-seq identified several DEGs, specifically RRM2, PRG4, and CXCL8, with known roles in tissue remodelling. These data along with an overall increase in leaflet cellularity suggest tricuspid leaflets actively remodel in FTR.

17.
Acta Biomater ; 2024 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-39214160

RESUMEN

There is an urgent critical need for a patient-forward vaginal stent that can prevent debilitating vaginal stenosis that occurs after pelvic radiation treatments and vaginal reconstruction. To this end, we developed a self-fitting vaginal stent based on a shape-memory polymer (SMP) foam that can assume a secondary, compressed shape for ease of deployment. Upon insertion, the change in temperature and hydration initiates foam expansion to shape fit to the individual patient and restore the lumen of the stent to allow egress of vaginal secretions. To achieve rapid actuation at physiological temperature, we investigated the effect of architecture of two photocurable, polycaprolactone (PCL) macromers. Star-PCL-tetraacrylate displayed a reduced melting temperature as compared to a linear-PCL-diacrylate. Upon fabrication into high porosity foams with emulsion-templating, both compositions displayed shape fixity (>90%) in a crimped, temporary shape. However, only the PCL star-foams displayed shape recovery (∼84%) at 37°C with expansion back to its permanent shape. A custom mold and curing system were then used to fabricate the PCL star-foams into hollow, cylindrical stents. The stent was crimped to its temporary insertion shape (50% reduction in diameter, OD ∼ 11 mm) with a custom radial crimper and displayed excellent shape fixity for deployment (> 95%) and shape recovery (∼ 100%). To screen vaginal stents, we developed a custom benchtop pelvic model that simulated vaginal anatomy, temperatures, and pressures with an associated computational model. The crimped SMP vaginal stent was deployed in the model and expanded to walls of the canal (∼70% increase in cross-sectional area) in less than 5 minutes after irrigation with warm water. The vaginal stent demonstrated retention of vaginal caliber with less than 1% decrease in cross-sectional area under physiological pressures. Collectively, this work demonstrates the potential for SMP foams as self-fitting vaginal stents to prevent stenosis and provides new open-source tools for the iterative design of other gynecological devices. STATEMENT OF SIGNIFICANCE: Vaginal stenosis, a painful narrowing of the vaginal canal, is a common complication after pelvic radiation therapy or reconstructive surgery. To address this clinical need, we have created a self-fitting vaginal stent from a shape-memory polymer foam. The stent compresses for easy insertion and then expands to adapt to each patient's anatomy to maintain an open vaginal canal and prevent stenosis. This innovative stent provides a patient-friendly solution that could make a significant difference for women undergoing pelvic treatments by reducing pain, aiding recovery, and improving quality of life.

18.
Circulation ; 126(11 Suppl 1): S231-8, 2012 Sep 11.
Artículo en Inglés | MEDLINE | ID: mdl-22965988

RESUMEN

BACKGROUND: We hypothesized that annuloplasty ring implantation alters mitral annular strains in a normal beating ovine heart preparation. METHODS AND RESULTS: Sheep had 16 radiopaque markers sewn equally spaced around the mitral annulus. Edwards Cosgrove partial flexible band (COS; n=12), St Jude complete rigid saddle-shaped annuloplasty ring (RSA; n=10), Carpentier-Edwards Physio (PHY; n=11), Edwards IMR ETlogix (ETL; n=11), and GeoForm (GEO; n=12) annuloplasty rings were implanted in a releasable fashion. Four-dimensional marker coordinates were obtained using biplane videofluoroscopy with the ring inserted (ring) and after ring release (control). From marker coordinates, a functional spatio-temporal representation of each annulus was generated through a best fit using 16 piecewise cubic Hermitian splines. Absolute total mitral annular ring strains were calculated from the relative change in length of the tangent vector to the annular curve as strains occurring from control to ring state at end-systole. In addition, average Green-Lagrange strains occurring from control to ring state at end-systole along the annulus were calculated. Absolute total mitral annular ring strains were smallest for COS and greatest for ETL. Strains for RSA, PHY, and GEO were similar. Except for COS in the septal mitral annular segment, all rings induced compressive strains along the entire annulus, with greatest values occurring at the lateral mitral annular segment. CONCLUSIONS: In healthy, beating ovine hearts, annuloplasty rings (COS, RSA, PHY, ETL, and GEO) induce compressive strains that are predominate in the lateral annular region, smallest for flexible partial bands (COS) and greatest for an asymmetrical rigid ring type with intrinsic septal-lateral downsizing (ETL). However, the ring type with the most drastic intrinsic septal-lateral downsizing (GEO) introduced strains similar to physiologically shaped rings (RSA and PHY), indicating that ring effects on annular strain profiles cannot be estimated from the degree of septal-lateral downsizing.


Asunto(s)
Anuloplastia de la Válvula Mitral/instrumentación , Contracción Miocárdica , Prótesis e Implantes , Animales , Fenómenos Biomecánicos , Fuerza Compresiva , Marcadores Fiduciales , Hemodinámica , Masculino , Diseño de Prótesis , Valores de Referencia , Ovinos , Resistencia a la Tracción
19.
J Mech Phys Solids ; 61(9): 1955-1969, 2013 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-23976792

RESUMEN

Understanding the difference between ex vivo and in vivo measurements is critical to interpret the load carrying mechanisms of living biological systems. For the past four decades, the ex vivo stiffness of thin biological membranes has been characterized using uniaxial and biaxial tests with remarkably consistent stiffness parameters, even across different species. Recently, the in vivo stiffness was characterized using combined imaging techniques and inverse finite element analyses. Surprisingly, ex vivo and in vivo stiffness values differed by up to three orders of magnitude. Here, for the first time, we explain this tremendous discrepancy using the concept of prestrain. We illustrate the mathematical modeling of prestrain in nonlinear continuum mechanics through the multiplicative decomposition of the total elastic deformation into prestrain-induced and load-induced parts. Using in vivo measured membrane kinematics and associated pressure recordings, we perform an inverse finite element analysis for different prestrain levels and show that the resulting membrane stiffness may indeed differ by four orders of magnitude depending on the prestrain level. Our study motivates the hypothesis that prestrain is important to position thin biological membranes in vivo into their optimal operating range, right at the transition point of the stiffening regime. Understanding the effect of prestrain has direct clinical implications in regenerative medicine, medical device design, and and tissue engineering of replacement constructs for thin biological membranes.

20.
Res Sq ; 2023 Jul 24.
Artículo en Inglés | MEDLINE | ID: mdl-37546861

RESUMEN

The skin is the largest organ in the human body and serves various functions, including mechanical protection and mechanosensation. Yet, even though skin's biomechanics are attributed to two main layers - epidermis and dermis-computational models have often treated this tissue as a thin homogeneous material or, when considering multiple layers, have ignored the most prominent heterogeneities of skin seen at the mesoscale. Here we create finite element models of representative volume elements (RVEs) of skin, including the three-dimensional variation of the interface between the epidermis and dermis as well as considering the presence of hair follicles. The sinusoidal interface, which approximates the anatomical features known as Rete ridges, does not affect the homogenized mechanical response of the RVE but contributes to stress concentration, particularly at the valleys of the Rete ridges. The stress profile is three-dimensional due to the skin's anisotropy, leading to high-stress bands connecting the valleys of the Rete ridges through one type of saddle point. The peaks of the Rete ridges and the other class of saddle points of the sinusoidal surface form a second set of low-stress bands under equi-biaxial loading. Another prominent feature of the heterogeneous stress pattern is a switch in the stress jump across the interface, which becomes lower with respect to the flat interface at increasing deformations. These features are seen in both tension and shear loading. The RVE with the hair follicle showed strains concentrating at the epidermis adjacent to the hair follicle, the epithelial tissue surrounding the hair right below the epidermis, and the bulb or base region of the hair follicle. The regions of strain concentration near the hair follicle in equi-biaxial and shear loading align with the presence of distinct mechanoreceptors in the skin, except for the bulb or base region. This study highlights the importance of skin heterogeneities, particularly its potential mechanophysiological role in the sense of touch and the prevention of skin delamination.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA