Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
J Minim Invasive Gynecol ; 24(1): 124-132, 2017 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-27687851

RESUMEN

STUDY OBJECTIVE: To assess the safety and effectiveness of the Minerva Endometrial Ablation System for the treatment of heavy menstrual bleeding in premenopausal women. DESIGN: Multicenter, randomized, controlled, international study (Canadian Task Force classification I). SETTING: Thirteen academic and private medical centers. PATIENTS: Premenopausal women (n = 153) suffering from heavy menstrual bleeding (PALM-COEIN: E, O). INTERVENTION: Patients were treated using the Minerva Endometrial Ablation System or rollerball ablation. MEASUREMENTS AND MAIN RESULTS: At 1-year post-treatment, study success (alkaline hematin ≤80 mL) was observed in 93.1% of Minerva subjects and 80.4% of rollerball subjects with amenorrhea reported by 71.6% and 49% of subjects, respectively. The mean procedure times were 3.1 minutes for Minerva and 17.2 minutes for rollerball. There were no intraoperative adverse events and/or complications reported. CONCLUSION: The results of this multicenter randomized controlled trial demonstrate that at the 12-month follow-up, the Minerva procedure produces statistically significantly higher rates of success, amenorrhea, and patient satisfaction as well as a shorter procedure time when compared with the historic criterion standard of rollerball ablation. Safety results were excellent and similar for both procedures.


Asunto(s)
Técnicas de Ablación Endometrial/efectos adversos , Técnicas de Ablación Endometrial/métodos , Menorragia/cirugía , Adulto , Femenino , Estudios de Seguimiento , Humanos , Histeroscopía/efectos adversos , Histeroscopía/métodos , Persona de Mediana Edad , Procedimientos Quirúrgicos Mínimamente Invasivos/efectos adversos , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Satisfacción del Paciente , Premenopausia , Resultado del Tratamiento , Estados Unidos , United States Food and Drug Administration
2.
Bioanalysis ; 8(6): 487-95, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26916197

RESUMEN

The 9th GCCClosed Forum was held just prior to the 2015 Workshop on Recent Issues in Bioanalysis (WRIB) in Miami, FL, USA on 13 April 2015. In attendance were 58 senior-level participants, from eight countries, representing 38 CRO companies offering bioanalytical services. The objective of this meeting was for CRO bioanalytical representatives to meet and discuss scientific and regulatory issues specific to bioanalysis. The issues selected at this year's closed forum include CAPA, biosimilars, preclinical method validation, endogenous biomarkers, whole blood stability, and ELNs. A summary of the industry's best practices and the conclusions from the discussion of these topics is included in this meeting report.


Asunto(s)
Biomarcadores/análisis , Biosimilares Farmacéuticos/análisis , Evaluación Preclínica de Medicamentos/métodos , Biomarcadores/sangre , Registros Electrónicos de Salud , Laboratorios , Sociedades Médicas , Estudios de Validación como Asunto
3.
Bioanalysis ; 6(22): 2957-63, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25496252

RESUMEN

The 8th GCC Closed Forum for Bioanalysis was held in Baltimore, MD, USA on 5 December 2013, immediately following the 2013 AAPS Workshop (Crystal City V): Quantitative Bioanalytical Methods Validation and Implementation--The 2013 Revised FDA Guidance. This GCC meeting was organized to discuss the contents of the draft revised FDA Guidance on bioanalytical method validation that was published in September 2013 and consolidate the feedback of the GCC members. In attendance were 63 senior-level participants, from seven countries, representing 46 bioanalytical CRO companies/sites. This event represented a unique opportunity for CRO bioanalytical experts to share their opinions and concerns regarding the draft FDA Guidance, and to build unified comments to be provided to the FDA.


Asunto(s)
Técnicas de Química Analítica/normas , Guías como Asunto , Estudios de Validación como Asunto , Biomarcadores/análisis , Calibración , Ligandos , Límite de Detección , Juego de Reactivos para Diagnóstico , Reproducibilidad de los Resultados , Estados Unidos , United States Food and Drug Administration
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA