Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Ann Vasc Surg ; 78: 123-131, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34437962

RESUMEN

BACKGROUND: Automated centerline (CL) measurements have been conventionally used for stent-graft length estimation during thoracic endovascular aortic repair (TEVAR). The purpose of this study was to assess the accuracy of greater curvature length (GL), semiautomated CL and straightened centerline length (SCL) for preprocedural planning in TEVAR. METHODS: Immediate postprocedural CT Angiographies of 30 patients (22 males, age-49.2 ± 10.1years) who underwent TEVAR between 2015 and 2017 were retrospectively analyzed. CL, GL, SCL and the straightline length(SL) were measured between proximal and distal ends of the stent-graft and results were compared with the true length of the stent-graft (TL). Tortuosity index (TI = CL/SL) was calculated. RESULTS: GL (17.92 ± 4.78 cm) was the closest in predicting the TL (17.75 ± 4.29 cm) (P = 0.414) overall, as well as in both dissection and aneurysm subgroups (P= 0.9). There was a significant difference between CL (16.67 ± 4.07 cm) and TL (P< 0.0001) as well as between SCL (16.86 ± 4.16 cm) and TL (P= 0.001). These differences were greater in dissection subgroup than in the aneurysm group (P< 0.0001 and P= 0.03 for TL-CL and TL-SCL, respectively). The extent of mismatch between GL or CL and TL did not correlate with tortuosity, but the difference between TL and SCL had a significant positive correlation with tortuosity (r = 0.375, P= 0.04). TL-GL had a negative linear correlation with the stent-graft length (TL) in the dissection group (r = 0.50, P= 0.03). CONCLUSIONS: The greater curvature length predicts the actual total length of the deployed stent-graft more accurately than centerline or straightened centerline lengths. Hence, it should be used in planning for the length of stent-graft required for TEVAR.


Asunto(s)
Aorta Torácica/anatomía & histología , Implantación de Prótesis Vascular , Prótesis Vascular , Procedimientos Endovasculares , Cuidados Preoperatorios , Adulto , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Stents , Tomografía Computarizada por Rayos X
2.
Indian J Thorac Cardiovasc Surg ; 38(6): 670-671, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36258830

RESUMEN

We hereby present an unusually long intra-atrial course of the right coronary artery incidentally detected on computed tomography angiography. Although usually asymptomatic, an intra-atrial right coronary artery may be injured during iatrogenic procedures which require right heart catheterisation.

3.
Indian J Thorac Cardiovasc Surg ; 36(4): 429-430, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33061155

RESUMEN

Rupture with fistulization of an abdominal aortic aneurysm with the vena cava is a rare complication and typically presents with congestive cardiac failure. Embolization of a thrombus from the aneurysm into the vena cava can however present in the absence of failure symptoms which can make it difficult to diagnose clinically without cross sectional imaging.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA