1.
N Engl J Med ; 2024 May 18.
Artículo en Inglés | MEDLINE | ID: mdl-38767244

RESUMEN

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (ICD) is associated with fewer lead-related complications than a transvenous ICD; however, the subcutaneous ICD cannot provide bradycardia and antitachycardia pacing. Whether a modular pacing-defibrillator system comprising a leadless pacemaker in wireless communication with a subcutaneous ICD to provide antitachycardia and bradycardia pacing is safe remains unknown. METHODS: We conducted a multinational, single-group study that enrolled patients at risk for sudden death from ventricular arrhythmias and followed them for 6 months after implantation of a modular pacemaker-defibrillator system. The safety end point was freedom from leadless pacemaker-related major complications, evaluated against a performance goal of 86%. The two primary performance end points were successful communication between the pacemaker and the ICD (performance goal, 88%) and a pacing threshold of up to 2.0 V at a 0.4-msec pulse width (performance goal, 80%). RESULTS: We enrolled 293 patients, 162 of whom were in the 6-month end-point cohort and 151 of whom completed the 6-month follow-up period. The mean age of the patients was 60 years, 16.7% were women, and the mean (±SD) left ventricular ejection fraction was 33.1±12.6%. The percentage of patients who were free from leadless pacemaker-related major complications was 97.5%, which exceeded the prespecified performance goal. Wireless-device communication was successful in 98.8% of communication tests, which exceeded the prespecified goal. Of 151 patients, 147 (97.4%) had pacing thresholds of 2.0 V or less, which exceeded the prespecified goal. The percentage of episodes of arrhythmia that were successfully terminated by antitachycardia pacing was 61.3%, and there were no episodes for which antitachycardia pacing was not delivered owing to communication failure. Of 162 patients, 8 died (4.9%); none of the deaths were deemed to be related to arrhythmias or the implantation procedure. CONCLUSIONS: The leadless pacemaker in wireless communication with a subcutaneous ICD exceeded performance goals for freedom from major complications related to the leadless pacemaker, for communication between the leadless pacemaker and subcutaneous ICD, and for the percentage of patients with a pacing threshold up to 2.0 V at a 0.4-msec pulse width at 6 months. (Funded by Boston Scientific; MODULAR ATP ClinicalTrials.gov NCT04798768.).

2.
Circulation ; 150(6): 439-450, 2024 Aug 06.
Artículo en Inglés | MEDLINE | ID: mdl-38973458

RESUMEN

BACKGROUND: A dual-chamber leadless pacemaker system has been designed for atrioventricular synchronous pacing using wireless, beat-to-beat, implant-to-implant (i2i) communication between distinct atrial and ventricular leadless pacemakers. The atrioventricular synchrony achieved across various ambulatory scenarios has yet to be systematically evaluated. METHODS: A prospective, single-arm, unblinded, multicenter, international clinical trial of the leadless pacemaker system was conducted in patients with a conventional dual-chamber pacing indication enrolled from February 2022 to March 2023. Leadless pacemaker systems were implanted, and 12-lead Holter electrocardiographic recordings were collected 3 months after implantation over various postures/activities: sitting, supine, left lateral recumbent, right lateral recumbent, standing, normal walk, and fast walk. An independent Holter core laboratory performed a manual adjudication of the percent of atrioventricular synchronous beats using the standard 300-millisecond PR interval limit. Atrium-to-ventricle and ventricle-to-atrium i2i communication success rates were also assessed. Post hoc summary statistics describing the relationships between atrioventricular synchrony and i2i success, posture/activity, implantation indication, atrioventricular event, and heart rate were calculated. RESULTS: In the evaluable population (n=384 of 464 enrolled [83%]; 61% male; age, 70 years; weight, 82 kg; 60% ejection fraction; 95% of beats evaluable), the mean atrioventricular synchrony of 98% of beats observed across all postures using the standard 300-millisecond limit was greater than both atrial-to-ventricular i2i (94%) and ventricular-to-atrial i2i (94%; P<0.001), exceeding both i2i values in 95% of patients. Atrioventricular synchrony was achieved in >95% of evaluable beats across all postures/activities, implantation indications, atrioventricular paced/sensed event combinations, and heart rate ranges (including >100 bpm). CONCLUSIONS: This dual-chamber leadless pacemaker system demonstrated atrioventricular synchrony in 98% of evaluable beats at 3 months after implantation. Atrioventricular synchrony was maintained across postures/activities and remained robust for heart rates >100 bpm.


Asunto(s)
Marcapaso Artificial , Humanos , Masculino , Femenino , Anciano , Estudios Prospectivos , Anciano de 80 o más Años , Frecuencia Cardíaca , Electrocardiografía Ambulatoria , Persona de Mediana Edad , Estimulación Cardíaca Artificial/métodos
3.
Eur Heart J ; 45(32): 2914-2932, 2024 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-39027946

RESUMEN

Atrial fibrillation (AF) is associated with an increased risk of stroke and systemic embolism, and the left atrial appendage (LAA) has been identified as a principal source of thromboembolism in these patients. While oral anticoagulation is the current standard of care, LAA closure (LAAC) emerges as an alternative or complementary treatment approach to reduce the risk of stroke or systemic embolism in patients with AF. Moderate-sized randomized clinical studies have provided data for the efficacy and safety of catheter-based LAAC, largely compared with vitamin K antagonists. LAA device iterations, advances in pre- and peri-procedural imaging, and implantation techniques continue to increase the efficacy and safety of LAAC. More data about efficacy and safety of LAAC have been collected, and several randomized clinical trials are currently underway to compare LAAC with best medical care (including non-vitamin K antagonist oral anticoagulants) in different clinical settings. Surgical LAAC in patients with AF undergoing cardiac surgery reduced the risk of stroke on background of anticoagulation therapy in the LAAOS III study. In this review, we describe the rapidly evolving field of LAAC and discuss recent clinical data, ongoing studies, open questions, and current limitations of LAAC.


Asunto(s)
Anticoagulantes , Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular , Humanos , Fibrilación Atrial/complicaciones , Apéndice Atrial/cirugía , Accidente Cerebrovascular/prevención & control , Accidente Cerebrovascular/etiología , Anticoagulantes/uso terapéutico , Ensayos Clínicos Controlados Aleatorios como Asunto , Dispositivo Oclusor Septal , Cierre del Apéndice Auricular Izquierdo
4.
Stroke ; 55(1): 214-225, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-38134262

RESUMEN

Nonvalvular atrial fibrillation is a common rhythm disorder of middle-aged to older adults that can cause ischemic strokes and systemic embolism. Lifelong use of oral anticoagulants reduces the risk of these ischemic events but increases the risk of major and clinically relevant hemorrhages. These medications also require strict compliance for efficacy, and they have nontrivial failure rates in higher-risk patients. Left atrial appendage closure is a nonpharmacological method to prevent ischemic strokes in atrial fibrillation without the need for lifelong anticoagulant use, but this procedure has the potential for complications and residual embolic events. This workshop of the Roundtable of Academia and Industry for Stroke Prevention discussed future research needed to further decrease the ischemic and hemorrhagic risks among patients with atrial fibrillation. A direct thrombin inhibitor, factor Xa inhibitors, and left atrial appendage closure are FDA-approved approaches whereas factor XIa inhibitors are currently being studied in phase 3 randomized controlled trials for stroke prevention. The benefits, risks, and shortcomings of these treatments and future research required in different high-risk patient populations are reviewed in this consensus statement.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Embolia , Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Persona de Mediana Edad , Humanos , Anciano , Fibrilación Atrial/complicaciones , Fibrilación Atrial/tratamiento farmacológico , Accidente Cerebrovascular/prevención & control , Accidente Cerebrovascular/complicaciones , Anticoagulantes/uso terapéutico , Embolia/complicaciones , Accidente Cerebrovascular Isquémico/tratamiento farmacológico , Resultado del Tratamiento
5.
J Cardiovasc Electrophysiol ; 35(8): 1688-1690, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38845147

RESUMEN

INTRODUCTION: Prior studies have indicated that the frequency of premature ventricular complexes (PVC) increases after catheter ablation for atrial fibrillation (AF). However, these studies have primarily focused on patients whose PVC burden increased rather than including the full spectrum of outcomes. METHODS AND RESULTS: We performed a single-center retrospective cohort study of consecutive patients who underwent first-time AF ablation from 1/2018 to 12/2022 for paroxysmal or persistent AF and had both preablation and postablation rhythm monitoring within 6 months of the procedure. Patients were excluded if they had prior AF or PVC ablation or were prescribed a class I or III antiarrhythmic medication. Among 2945 patients who underwent AF ablation during the study period, 130 patients underwent first-time AF ablation and received both pre and post ambulatory monitoring. The median PVC burden before ablation was <1%. Most patients (63%) had no change in PVC burden after AF ablation compared with preablation, and patients who had an increase in PVC burden were offset by those with reductions in PVCs. A paired analysis pre- and post-AF ablation showed no significant change in PVC burden (p = .495). CONCLUSION: Although an elevated PVC burden after AF ablation may be seen clinically, the majority of patients have no change in burden. Studies that suggest an increase in PVC burden after AF ablation may suffer from incomplete sample selection and thus omit the important effect of regression to the mean.


Asunto(s)
Potenciales de Acción , Fibrilación Atrial , Ablación por Catéter , Frecuencia Cardíaca , Complejos Prematuros Ventriculares , Humanos , Complejos Prematuros Ventriculares/cirugía , Complejos Prematuros Ventriculares/fisiopatología , Complejos Prematuros Ventriculares/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Ablación por Catéter/efectos adversos , Masculino , Femenino , Estudios Retrospectivos , Persona de Mediana Edad , Resultado del Tratamiento , Anciano , Factores de Tiempo , Factores de Riesgo , Electrocardiografía Ambulatoria
6.
J Card Fail ; 30(7): 877-889, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38211934

RESUMEN

OBJECTIVE: Splanchnic vasoconstriction augments transfer of blood volume from the abdomen into the thorax, which may increase filling pressures and hemodynamic congestion in patients with noncompliant hearts. Therapeutic interruption of splanchnic nerve activity holds promise to reduce hemodynamic congestion in patients with heart failure with preserved ejection fraction (HFpEF). Here we describe (1) the rationale and design of the first sham-controlled, randomized clinical trial of splanchnic nerve ablation for HFpEF and (2) the 12-month results of the lead-in (open-label) trial's participants. METHODS: REBALANCE-HF is a prospective, multicenter, randomized, double-blinded, sham-controlled clinical trial of endovascular, transcatheter, right-sided greater splanchnic nerve ablation for volume management (SAVM) in patients with HFpEF. The primary objectives are to evaluate the safety and efficacy of SAVM and identify responder characteristics to inform future studies. The trial consists of an open-label lead-in phase followed by the randomized, sham-controlled phase. The primary efficacy endpoint is the reduction in pulmonary capillary wedge pressure (PCWP) at 1-month follow-up compared to baseline during passive leg raise and 20W exercise. Secondary and exploratory endpoints include health status (Kansas City Cardiomyopathy Questionnaire), 6-minute walk test distance, New York Heart Association class, and NTproBNP levels at 3, 6 and 12 months. The primary safety endpoint is device- or procedure-related serious adverse events at the 1-month follow-up. RESULTS: The lead-in phase of the study, which enrolled 26 patients with HFpEF who underwent SAVM, demonstrated favorable safety outcomes and reduction in exercise PCWP at 1 month post-procedure and improvements in all secondary endpoints at 6 and 12 months of follow-up. The randomized phase of the trial (n = 44 SAVM; n = 46 sham) has completed enrollment, and follow-up is ongoing. CONCLUSION: REBALANCE-HF is the first sham-controlled randomized clinical trial of greater splanchnic nerve ablation in HFpEF. Initial 12-month open-label results are promising, and the results of the randomized portion of the trial will inform the design of a future pivotal clinical trial. SAVM may offer a promising therapeutic option for patients with HFpEF. TRIAL REGISTRATION: NCT04592445.


Asunto(s)
Insuficiencia Cardíaca , Nervios Esplácnicos , Volumen Sistólico , Humanos , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/cirugía , Insuficiencia Cardíaca/terapia , Volumen Sistólico/fisiología , Método Doble Ciego , Nervios Esplácnicos/cirugía , Masculino , Femenino , Estudios Prospectivos , Procedimientos Endovasculares/métodos , Resultado del Tratamiento , Anciano , Persona de Mediana Edad , Técnicas de Ablación/métodos , Estudios de Seguimiento
7.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38582974

RESUMEN

AIMS: The ultra-low-temperature cryoablation (ULTC) ablation system using -196°C N2 cryogen has been reported to create lesions with freeze duration-dependent depth titratable to over 10 mm with minimum attenuation by scar. Cryocure-VT (NCT04893317) was a first-in-human clinical trial evaluating the safety and efficacy of a novel, purpose-built ULTC catheter in endocardial ablation of scar-dependent ventricular tachycardias (VTs). METHODS AND RESULTS: This prospective, multi-centre study enrolled patients referred for de novo or second ablations of recurrent monomorphic VT of both ischaemic and non-ischaemic aetiologies. Primary safety and efficacy endpoints of the study were freedom from device- or procedure-related major adverse events (MAEs) up to 30 days post-ablation, acute non-inducibility of clinical VTs at the end of the procedure, and freedom from sustained VT or implantable defibrillator intervention at 6 months. Ultra-low-temperature cryoablation was performed in 64 patients (age 67 ± 11 years, 78% ischaemic, ejection fraction = 35 ± 10%) at 9 centres. The primary acute effectiveness endpoint was achieved in 94% (51/54) of patients in whom post-ablation induction was attempted. There were no protocol-defined MAEs; four procedure-related serious adverse events resolved without clinical sequelae. At 6-month follow-up, 38 patients (60.3%) remained VT-free, and freedom from defibrillator shock was 81.0%, with no significant difference between ischaemic and non-ischaemic cohorts. In 47 patients with defibrillator for at least 6 months prior to the ablation, the VT burden was reduced from median of 4, inter-quartile range (IQR, 1-9) to 0, IQR (0-2). CONCLUSION: In this first-in-human multi-centre experience, endocardial ULTC ablation of monomorphic VT appears safe and effective in patients with both ischaemic-cardiomyopathy and non-ischaemic-cardiomyopathy. CLINICAL TRIAL REGISTRATION: NCT04893317.


Asunto(s)
Cardiomiopatías , Ablación por Catéter , Criocirugía , Taquicardia Ventricular , Anciano , Humanos , Persona de Mediana Edad , Cardiomiopatías/complicaciones , Cardiomiopatías/diagnóstico , Cardiomiopatías/cirugía , Ablación por Catéter/efectos adversos , Cicatriz/complicaciones , Criocirugía/efectos adversos , Estudios Prospectivos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiología , Taquicardia Ventricular/cirugía , Temperatura , Resultado del Tratamiento
8.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38584468

RESUMEN

AIMS: Pulsed field ablation (PFA) has significant advantages over conventional thermal ablation of atrial fibrillation (AF). This first-in-human, single-arm trial to treat paroxysmal AF (PAF) assessed the efficiency, safety, pulmonary vein isolation (PVI) durability and one-year clinical effectiveness of an 8 Fr, large-lattice, conformable single-shot PFA catheter together with a dedicated electroanatomical mapping system. METHODS AND RESULTS: After rendering the PV anatomy, the PFA catheter delivered monopolar, biphasic pulse trains (5-6 s per application; ∼4 applications per PV). Three waveforms were tested: PULSE1, PULSE2, and PULSE3. Follow-up included ECGs, Holters at 6 and 12 months, and symptomatic and scheduled transtelephonic monitoring. The primary and secondary efficacy endpoints were acute PVI and post-blanking atrial arrhythmia recurrence, respectively. Invasive remapping was conducted ∼75 days post-ablation. At three centres, PVI was performed by five operators in 85 patients using PULSE1 (n = 30), PULSE2 (n = 20), and PULSE3 (n = 35). Acute PVI was achieved in 100% of PVs using 3.9 ± 1.4 PFA applications per PV. Overall procedure, transpired ablation, PFA catheter dwell and fluoroscopy times were 56.5 ± 21.6, 10.0 ± 6.0, 19.1 ± 9.3, and 5.7 ± 3.9 min, respectively. No pre-defined primary safety events occurred. Upon remapping, PVI durability was 90% and 99% on a per-vein basis for the total and PULSE3 cohort, respectively. The Kaplan-Meier estimate of one-year freedom from atrial arrhythmias was 81.8% (95% CI 70.2-89.2%) for the total, and 100% (95% CI 80.6-100%) for the PULSE3 cohort. CONCLUSION: Pulmonary vein isolation (PVI) utilizing a conformable single-shot PFA catheter to treat PAF was efficient, safe, and effective, with durable lesions demonstrated upon remapping.


Asunto(s)
Fibrilación Atrial , Catéteres Cardíacos , Ablación por Catéter , Venas Pulmonares , Recurrencia , Humanos , Venas Pulmonares/cirugía , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Ablación por Catéter/métodos , Ablación por Catéter/instrumentación , Masculino , Femenino , Persona de Mediana Edad , Anciano , Resultado del Tratamiento , Diseño de Equipo , Técnicas Electrofisiológicas Cardíacas , Factores de Tiempo , Frecuencia Cardíaca , Potenciales de Acción
9.
Europace ; 26(7)2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-38912887

RESUMEN

AIMS: Pulsed field ablation (PFA) is an emerging non-thermal ablative modality demonstrating considerable promise for catheter ablation of atrial fibrillation (AF). However, these PFA trials have almost universally included only Caucasian populations, with little data on its effect on other races/ethnicities. The PLEASE-AF trial sought to study the 12-month efficacy and the safety of a multi-electrode hexaspline PFA catheter in treating a predominantly Asian/Chinese population of patients with drug-refractory paroxysmal AF. METHODS AND RESULTS: Patients underwent pulmonary vein (PV) isolation (PVI) by delivering different pulse intensities at the PV ostium (1800 V) and atrium (2000 V). Acute success was defined as no PV potentials and entrance/exit conduction block of all PVs after a 20-min waiting period. Follow-up at 3, 6, and 12 months included 12-lead electrocardiogram and 24-h Holter examinations. The primary efficacy endpoint was 12-month freedom from any atrial arrhythmias lasting at least 30 s. The cohort included 143 patients from 12 hospitals treated by 28 operators: age 60.2 ± 10.0 years, 65.7% male, Asian/Chinese 100%, and left atrial diameter 36.6 ± 4.9 mm. All PVs (565/565, 100%) were successfully isolated. The total procedure, catheter dwell, total PFA application, and total fluoroscopy times were 123.5 ± 38.8 min, 63.0 ± 30.7 min, 169.7 ± 34.6 s, and 27.3 ± 10.1 min, respectively. The primary endpoint was observed in 124 of 143 patients (86.7%). One patient (0.7%) developed a small pericardial effusion 1-month post-procedure, not requiring intervention. CONCLUSION: The novel hexaspline PFA catheter demonstrated universal acute PVI with an excellent safety profile and promising 12-month freedom from recurrent atrial arrhythmias in an Asian/Chinese population with paroxysmal AF. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT05114954.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Masculino , Femenino , Persona de Mediana Edad , Ablación por Catéter/métodos , Ablación por Catéter/efectos adversos , Venas Pulmonares/cirugía , Venas Pulmonares/fisiopatología , Anciano , Resultado del Tratamiento , Pueblo Asiatico , China , Catéteres Cardíacos , Recurrencia , Electrocardiografía Ambulatoria , Factores de Tiempo , Diseño de Equipo , Frecuencia Cardíaca , Potenciales de Acción
10.
Europace ; 26(2)2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38305503

RESUMEN

AIMS: When it occurs, pulmonary vein (PV) stenosis after atrial fibrillation (AF) ablation is associated with significant morbidity. Even mild-to-moderate PV narrowing may have long-term implications. Unlike thermal ablation energies, such as radiofrequency (RF) or cryothermy, pulsed field ablation (PFA) is a non-thermal modality associated with less fibrotic proliferation. Herein, we compared the effects of PFA vs. thermal ablation on PV narrowing after AF ablation. METHODS AND RESULTS: ADVENT was a multi-centre, randomized, single-blind study comparing PFA (pentaspline catheter) with thermal ablation-force-sensing RF or cryoballoon (CB)-to treat drug-refractory paroxysmal AF. Pulmonary vein diameter and aggregate cross-sectional area were obtained by baseline and 3-month imaging. The pre-specified, formally tested, secondary safety endpoint compared a measure of PV narrowing between PFA vs. thermal groups, with superiority defined by posterior probability > 0.975. Among subjects randomized to PFA (n = 305) or thermal ablation (n = 302), 259 PFA and 255 thermal ablation (137 RF and 118 CB) subjects had complete baseline and 3-month PV imaging. No subject had significant (≥70%) PV stenosis. Change in aggregate PV cross-sectional area was less with PFA (-0.9%) than thermal ablation (-12%, posterior probability > 0.999)-primarily driven by the RF sub-cohort (-19.5%) vs. CB sub-cohort (-3.3%). Almost half of all PFA PV diameters did not decrease, but the majority (80%) of RF PVs decreased, regardless of PV anatomic location. CONCLUSION: In this first randomized comparison of PFA vs. thermal ablation, PFA resulted in less PV narrowing-thereby underscoring the qualitatively differential and favourable impact of PFA on PV tissue.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Estenosis de Vena Pulmonar , Humanos , Venas Pulmonares/cirugía , Constricción Patológica/complicaciones , Constricción Patológica/cirugía , Método Simple Ciego , Resultado del Tratamiento , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/complicaciones , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Estenosis de Vena Pulmonar/diagnóstico por imagen , Estenosis de Vena Pulmonar/etiología
11.
N Engl J Med ; 390(11): 1055-1056, 2024 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-38477999
12.
J Pharm Bioallied Sci ; 16(Suppl 1): S850-S852, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38595389

RESUMEN

Background: Open bite is a common orthodontic malocclusion that can have functional and aesthetic implications. Traditional orthodontic treatments have been used to correct open bites, but the effectiveness of Invisalign, a clear aligner therapy, in open bite correction remains a topic of interest. Materials and Methods: A retrospective analysis was conducted on a cohort of 50 patients with open bites who underwent Invisalign treatment. Pre-treatment and post-treatment records, including cephalometric radiographs, dental models, and clinical photographs, were assessed. The open bite was defined as a negative overbite greater than 2 mm. Treatment duration, number of aligners used, and patient compliance were also recorded. Statistical analysis, including paired t-tests and subjective patient feedback, was employed to evaluate the treatment outcomes. Results: The mean pre-treatment open bite was -3.5 mm (SD = 1.2), and the mean treatment duration was 18 months (SD = 2.5). On average, patients received 24 sets of aligners (SD = 4.1) during the treatment. Post-treatment evaluation showed that the mean overbite improved to + 1.5 mm (SD = 0.8), indicating successful open bite correction. The paired t-test revealed a statistically significant difference between pre-treatment and post-treatment open bite measurements (P < 0.001). Patient satisfaction was high, with 90% of participants reporting improved aesthetics and comfort. Conclusion: Invisalign treatment demonstrates effectiveness in correcting open bites, with statistically significant improvements in overbite measurements.

13.
Heart Rhythm ; 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38752906

RESUMEN

BACKGROUND: Rapid technologic development and expansion of procedural expertise have led to widespread proliferation of catheter-based electrophysiology procedures. It is unclear whether these advances come at cost to patient safety. OBJECTIVE: This meta-analysis aimed to assess complication rates after modern electrophysiology procedures during the lifetime of the procedures. METHODS: A comprehensive search was performed to identify relevant data published before May 30, 2023. Studies were included if they met the following inclusion criteria: prospective trials or registries, including comprehensive complications data; and patients undergoing atrial fibrillation ablation, ventricular tachyarrhythmia ablation, leadless cardiac pacemaker implantation, and percutaneous left atrial appendage occlusion. Pooled incidences of procedure-related complications were individually assessed by random effects models to account for heterogeneity. Temporal trends in complications were investigated by clustering trials by publication year (2000-2018 vs 2019-2023). RESULTS: A total of 174 studies (43,914 patients) met criteria for analysis: 126 studies of atrial fibrillation ablation (n = 24,057), 25 studies of ventricular tachyarrhythmia ablation (n = 1781), 21 studies of leadless cardiac pacemaker (n = 8896), and 18 studies of left atrial appendage occlusion (n = 9180). The pooled incidences of serious procedure-related complications (3.49% [2000-2018] vs 3.05% [2019-2023]; P < .001), procedure-related stroke (0.46% vs 0.28%; P = .002), pericardial effusion requiring intervention (1.02% vs 0.83%; P = .037), and procedure-related death (0.15% vs 0.06%; P = .003) significantly decreased over time. However, there was no significant difference in the incidence of vascular complications over time (1.86% vs 1.88%; P = .888). CONCLUSION: Despite an increase in cardiac electrophysiology procedures, procedural safety has improved over time.

14.
Circ Arrhythm Electrophysiol ; 17(6): e012734, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38753535

RESUMEN

BACKGROUND: Endocardial catheter-based pulsed field ablation (PFA) of the ventricular myocardium is promising. However, little is known about PFA's ability to target intracavitary structures, epicardium, and ways to achieve transmural lesions across thick ventricular tissue. METHODS: A lattice-tip catheter was used to deliver biphasic monopolar PFA to swine ventricles under general anesthesia, with electroanatomical mapping, fluoroscopy and intracardiac echocardiography guidance. We conducted experiments to assess the feasibility and safety of repetitive monopolar PFA applications to ablate (1) intracavitary papillary muscles and moderator bands, (2) epicardial targets, and (3) bipolar PFA for midmyocardial targets in the interventricular septum and left ventricular free wall. RESULTS: (1) Papillary muscles (n=13) were successfully ablated and then evaluated at 2, 7, and 21 days. Nine lesions with stable contact measured 18.3±2.4 mm long, 15.3±1.5 mm wide, and 5.8±1.0 mm deep at 2 days. Chronic lesions demonstrated preserved chordae without mitral regurgitation. Two targeted moderator bands were transmurally ablated without structural disruption. (2) Transatrial saline/carbon dioxide assisted epicardial access was obtained successfully and epicardial monopolar lesions had a mean length, width, and depth of 30.4±4.2, 23.5±4.1, and 9.1±1.9 mm, respectively. (3) Bipolar PFA lesions were delivered across the septum (n=11) and the left ventricular free wall (n=7). Twelve completed bipolar lesions had a mean length, width, and depth of 29.6±5.5, 21.0±7.3, and 14.3±4.7 mm, respectively. Chronically, these lesions demonstrated uniform fibrotic changes without tissue disruption. Bipolar lesions were significantly deeper than the monopolar epicardial lesions. CONCLUSIONS: This in vivo evaluation demonstrates that PFA can successfully ablate intracavitary structures and create deep epicardial lesions and transmural left ventricular lesions.


Asunto(s)
Ablación por Catéter , Ventrículos Cardíacos , Tabique Interventricular , Animales , Tabique Interventricular/fisiopatología , Tabique Interventricular/diagnóstico por imagen , Tabique Interventricular/cirugía , Ablación por Catéter/métodos , Ablación por Catéter/instrumentación , Porcinos , Ventrículos Cardíacos/fisiopatología , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/cirugía , Estudios de Factibilidad , Músculos Papilares/fisiopatología , Músculos Papilares/cirugía , Músculos Papilares/diagnóstico por imagen , Factores de Tiempo , Pericardio/cirugía , Pericardio/fisiopatología , Catéteres Cardíacos , Ultrasonografía Intervencional , Técnicas Electrofisiológicas Cardíacas , Diseño de Equipo , Femenino
15.
Clinicoecon Outcomes Res ; 16: 81-96, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38374959

RESUMEN

Background: As healthcare costs are increasingly being shifted from payers to patients, it is important to understand the economic consequences of therapeutic strategies to both payers and patients. Objective: To determine the relative costs to Medicare and Medicare beneficiaries (patients) of warfarin, non-vitamin K oral anticoagulants (NOACs), and left atrial appendage closure (LAAC) for stroke risk reduction in nonvalvular atrial fibrillation. Methods: An economic model was developed to assess costs at 5 and 10 years. For warfarin and NOACs, inputs were derived from published meta-analyses; for LAAC with the Watchman device, inputs were derived from pooled 5-year PROTECT AF and PREVAIL trial results. The model captured therapy costs vs clinical event costs, including procedural complications and follow-up clinical outcomes. Costs were based on 2023 Medicare reimbursement and copayment rates. Results: At 10 years, overall LAAC costs ($48,337) were lower than those of NOACs ($81,198) and warfarin ($52,359). Overall LAAC costs were lower than those of NOACs by year 5 and warfarin by year 9. At 5 years, patient LAAC costs were lowest at $4,764, compared to $7,146 and $6,453 for NOACs and warfarin, respectively. LAAC patient costs were lower than those of NOACs by year 3 and warfarin by year 4. Clinical events comprised 96% of overall warfarin costs vs 48% for LAAC and 40% for NOACs. Conclusion: LAAC yielded the lowest overall and patient costs. Warfarin costs were largely driven by clinical events, which may represent an unplanned financial burden for patients. These considerations should be incorporated into shared decision-making discussions about stroke prophylaxis strategies.

16.
Heart Rhythm ; 21(8): 1218-1226, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38768840

RESUMEN

BACKGROUND: During pulsed field ablation (PFA), electrode-tissue proximity optimizes lesion quality. A novel "single-shot" map-and-ablate spherical multielectrode PFA array catheter that is able to verify electrode-tissue contact was recently studied in a first-in-human trial of atrial fibrillation (AF). OBJECTIVE: The aim of this study was to report lesion durability data, safety, and 12-month effectiveness outcomes. METHODS: The spherical PFA catheter, an all-in-one mapping and ablation system, was used to render anatomy and to deliver biphasic pulses (ungated 1.7 kV pulses; ∼40 seconds/application). Ablation sites included pulmonary veins (PVs) and, in selected patients, posterior wall and mitral isthmus. Follow-up was invasive remapping at ∼3 months, electrocardiograms, Holter monitoring at 6 and 12 months, and symptomatic and scheduled transtelephonic monitoring. The primary and secondary efficacy end points were acute PV isolation (PVI), PVI durability, and atrial arrhythmia recurrence. RESULTS: In the 48-patient AF cohort (paroxysmal, 48%; persistent, 52%), lesion sets included PVI (n = 48; 1.2 applications/PV), posterior wall (n = 20; 3.6 applications/posterior wall), and mitral isthmus (n = 11; 2.9 applications/mitral isthmus). Lesions were acutely successful for all 187 of 187 PVs (100%), 20 of 20 posterior walls (100%), and 10 of 11 mitral isthmuses (91%). Pulse delivery time, left atrial catheter dwell time, and procedure time were 61.5 ± 32.8 seconds, 53.9 ± 26.5 minutes, and 87.8 ± 29.8 minutes, respectively. Remapping (43/48 patients [89.5%]) revealed that 158 of 169 PVs (93.5%) were durably isolated. The only complication was a drug-responsive pericarditis. The 1-year Kaplan-Meier estimates of freedom from atrial arrhythmia were 84.2% (paroxysmal AF) and 80.0% (persistent AF). CONCLUSION: The single-shot spherical array PFA catheter can safely achieve durable lesions, translating into good clinical efficacy.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Ablación por Catéter/métodos , Ablación por Catéter/instrumentación , Masculino , Femenino , Venas Pulmonares/cirugía , Persona de Mediana Edad , Resultado del Tratamiento , Diseño de Equipo , Estudios de Seguimiento , Electrocardiografía Ambulatoria/métodos , Sistema de Conducción Cardíaco/fisiopatología , Anciano , Factores de Tiempo , Recurrencia
17.
JACC Clin Electrophysiol ; 10(7 Pt 2): 1660-1671, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38852101

RESUMEN

BACKGROUND: Hemolysis-related renal failure has been described after pulmonary vein isolation (PVI) with pulsed-field ablation (PFA). OBJECTIVES: This study sought to compare the potential for hemolysis during PVI with PFA vs radiofrequency ablation (RFA). METHODS: In consecutive patients, PVI was performed with PFA or RFA. Blood samples were drawn at baseline, immediately postablation, and 24 hours postablation. Using flow cytometry, the concentration of red blood cell microparticles (RBCµ) (fragments of damaged erythrocytes) in blood was assessed. Lactate dehydrogenase (LDH), haptoglobin, and indirect bilirubin were measured at baseline and 24 hours. RESULTS: Seventy patients (age: 64.7 ± 10.2 years; 47% women; 36 [51.4%] paroxysmal atrial fibrillation) were enrolled: 47 patients were in the PFA group (22 PVI-only and 36.4 ± 5.5 PFA applications; 25 PVI-plus, 67.3 ± 12.4 pulsed field energy applications), and 23 patients underwent RFA. Compared to baseline, the RBCµ concentration increased ∼12-fold postablation and returned to baseline by 24 hours in the PFA group (median: 70.8 [Q1-Q3: 51.8-102.5] vs 846.6 [Q1-Q3: 639.2-1,215.5] vs 59.3 [Q1-Q3: 42.9-86.5] RBCµ/µL, respectively; P < 0.001); this increase was greater with PVI-plus compared to PVI-only (P = 0.007). There was also a significant, albeit substantially smaller, periprocedural increase in RBCµ with RFA (77.7 [Q1-Q3: 39.2-92.0] vs 149.6 [Q1-Q3: 106.6-180.8] vs 89.0 [Q1-Q3: 61.2-123.4] RBCµ/µL, respectively; P < 0.001). At 24 hours with PFA, the concentration of LDH and indirect bilirubin increased, whereas haptoglobin decreased significantly (all P < 0.001). In contrast, with RFA, there were only smaller changes in LDH and haptoglobin concentrations (P = 0.03) and no change in bilirubin. CONCLUSIONS: PFA was associated with significant periprocedural hemolysis. With a number of 70 PFA lesions, the likelihood of significant renal injury is uncommon.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Hemólisis , Humanos , Femenino , Fibrilación Atrial/cirugía , Masculino , Persona de Mediana Edad , Anciano , Ablación por Catéter/efectos adversos , Venas Pulmonares/cirugía , Ablación por Radiofrecuencia/efectos adversos , Ablación por Radiofrecuencia/métodos , Estudios Prospectivos
18.
Heart Rhythm ; 21(4): 389-396, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38159790

RESUMEN

BACKGROUND: Ultrastructural findings immediately after pulsed field ablation (PFA) of the myocardium have not been described. OBJECTIVES: The purpose of this study was to elucidate ultrastructural characteristics and differences between microsecond PFA at the 1- and 4-hour timepoints after pulse delivery and to compare them to irrigated radiofrequency ablation (RFA) lesions. METHODS: Healthy swine underwent endocardial PFA or RFA followed by necropsy. Discrete microsecond PFA and irrigated RFA lesions were created in the ventricles with a lattice tip ablation catheter. Lesions were delivered in a manner so as to allow sampling to occur 1 and 4 hours after ablation. All lesions were located at necropsy, and samples were carefully obtained from within the lesion core, lesion periphery, and adjacent healthy myocardium. Transmission electron microscopic assessment was performed after fixation using paraformaldehyde and glutaraldehyde. RESULTS: One hour after microsecond PFA delivery, myocytes were noted to be significantly and uniformly disrupted. Clustered, misaligned, swollen mitochondria coupled with degenerating nuclei and condensed chromatin were visualized. These findings progressed over the subsequent few hours with worsening edema. Similar changes were seen with RFA but reduced in severity. However, there was prominent extravasation of red blood cells with occlusion of capillaries that was not seen in PFA. At the lesion periphery, an abrupt change in the degree of myocyte damage was observed with PFA but not RFA. CONCLUSION: Transmission electron microscopy demonstrates evidence of widespread destruction of myocytes as early as an hour after PFA and corroborates known histologic features such as sparing of vessels and sharp lesion margins.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Ablación por Radiofrecuencia , Porcinos , Animales , Ablación por Catéter/efectos adversos , Miocardio , Ventrículos Cardíacos/cirugía , Frecuencia Cardíaca , Fibrilación Atrial/cirugía
19.
Artículo en Inglés | MEDLINE | ID: mdl-38509402

RESUMEN

BACKGROUND: Roughly one in six patients receiving conventional transvenous pacemaker systems experience significant complications within 1 year of implant, mainly due to the transvenous lead and subcutaneous pocket. A new helix-fixation single-chamber ventricular leadless pacemaker (LP) system capable of pre-deployment exploratory electrical mapping is commercially available. Such an LP may mitigate complications while streamlining the implantation. In this study, the initial real-world implant experience of the helix-fixation LP was evaluated following its commercial release. METHODS: In patients indicated for single-chamber right ventricular pacing, helix-fixation Aveir VR LPs (Abbott, Abbott Park, IL) were implanted using the dedicated loading tool, introducer, and delivery catheter. Implant procedural characteristics, electrical parameters, and any 30-day procedure-related adverse events of consecutive implant attempts were retrospectively evaluated. RESULTS: A total of 167 patients with Class I indication for permanent pacing received implants in four North American centers (57% male, 70 years old). Pre-fixation electrical mapping of potential sites allowed repositioning to be avoided in 95.7% of patients. Median [interquartile range] LP procedure and fluoroscopy durations were 25.5 min [20.0, 35.0] and 5.7 min [4.0, 9.2], respectively. Pacing capture threshold, sensed R-wave amplitude, and impedance were 0.8 V [0.5, 1.3], 9.0 mV [6.0, 12.0], and 705 Ω [550, 910], respectively. Implantation was successful in 98.8% of patients, with 98.2% free from acute adverse events. CONCLUSIONS: The initial, real-world experience of the helix-fixation ventricular leadless pacemaker demonstrated safe and efficient implantation with minimal repositioning, viable electrical metrics, and limited acute complications.

20.
Heart Rhythm ; 2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38697271

RESUMEN

BACKGROUND: The first dual-chamber leadless pacemaker (DC-LP) system consists of 2 separate atrial and ventricular devices that communicate to maintain synchronous atrioventricular pacing and sensing. The initial safety and efficacy were previously reported. OBJECTIVE: The purpose of this study was to evaluate the chronic electrical performance of the DC-LP system. METHODS: Patients meeting standard dual-chamber pacing indications were enrolled and implanted with the DC-LP system (Aveir DR, Abbott), including right atrial and ventricular helix-fixation LPs (atrial leadless pacemaker [ALP], ventricular leadless pacemaker [VLP]). Pacing capture threshold, sensed amplitude, and pacing impedance were collected using the device programmer at prespecified timepoints from 0-6 months postimplant. RESULTS: De novo devices were successfully implanted in 381 patients with complete 6-month data (62% male; age 69 ± 14 years; weight 82 ± 20 kg; 65% sinus nodal dysfunction, 30% atrioventricular block). ALPs were implanted predominantly in the right atrial appendage anterior base and VLPs primarily at the mid-to-apical right ventricular septum. From implant to 1 month, pacing capture thresholds (0.4-ms pulse width) improved in both ALPs (2.4 ± 1.5 V to 0.8 ± 0.8 V; P <.001) and VLPs (0.8 ± 0.6 V to 0.6 ± 0.4 V; P <.001). Sensed amplitudes improved in both ALPs (1.8 ± 1.3 mV to 3.4 ± 1.9 mV; P <.001) and VLPs (8.8 ± 4.0 mV to 11.7 ± 4.2 mV; P <.001). Impedances were stable in ALPs (334 ± 68 Ω to 329 ± 52 Ω; P = .17) and reduced in VLPs (789 ± 351 Ω to 646 ± 190 Ω; P <.001). Electrical measurements remained relatively stable from 1-6 months postimplant. No differences in electrical metrics were observed among ALP or VLP implant locations. CONCLUSION: This first in-human evaluation of the new dual-chamber leadless pacemaker system demonstrated reliable electrical performance throughout the initial 6-month evaluation period.