Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Sensors (Basel) ; 9(2): 995-1011, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-22399952

RESUMEN

The thixotropic-like properties of saline/glycerol drops, containing biotinylated capture antibodies, on streptavidin-coated glass slides have been investigated, along with their implications for bacterial detection in a fluorescent microarray immunoassay. The thixotropic-like nature of 60:40 saline-glycerol semisolid droplets (with differing amounts of antibodies) was observed when bacteria were captured, and their presence detected using a fluorescently-labeled antibody. Semisolid, gel-like drops of biotinylated capture antibody became liquefied and moved, and then returned to semisolid state, during the normal immunoassay procedures for bacterial capture and detection. Streaking patterns were observed that indicated thixotropic-like characteristics, and this appeared to have allowed excess biotinylated capture antibody to participate in bacterial capture and detection. When developing a microarray for bacterial detection, this must be considered for optimization. For example, with the appropriate concentration of antibody (in this study, 0.125 ng/nL), spots with increased diameter at the point of contact printing (and almost no streaking) were produced, resulting in a maximal signal. With capture antibody concentrations greater than 0.125 ng/nL, the excess biotinylated capture antibody (i.e., that which was residing in the three-dimensional, semisolid droplet space above the surface) was utilized to capture more bacteria. Similarly, when the immunoassay was performed within a hydrophobic barrier (i.e., without a coverslip), brighter spots with increased signal were observed. In addition, when higher concentrations of cells (∼10(8) cells/mL) were available for capture, the importance of unbound capture antibody in the semisolid droplets became apparent because washing off the excess, unbound biotinylated capture antibody before the immunoassay was performed reduced the signal intensity by nearly 50%. This reduction in signal was not observed with lower concentrations of cells (∼10(6) cells/mL). With increased volumes of capture antibody, abnormal spots were visualized, along with decreased signal intensity, after bacterial detection, indicating that the increased droplet volume detrimentally affected the immunoassay.

2.
Anal Bioanal Chem ; 391(2): 497-506, 2008 May.
Artículo en Inglés | MEDLINE | ID: mdl-18389224

RESUMEN

Intoxication and infection caused by foodborne pathogens are important problems worldwide, and screening tests for multiple pathogens are needed because foods may be contaminated with multiple pathogens and/or toxic metabolites. We developed a 96-well microplate, multiplex antibody microarray method to simultaneously capture and detect Escherichia coli O157:H7 and Salmonella enterica serovar Typhimurium (S. typhimurium), as well as a biomolecule (chicken immunoglobulin G or IgG employed as a proteinaceous toxin analog) in a single sample. Microarrayed spots of capture antibodies against the targeted analytes were printed within individual wells of streptavidin-coated polystyrene 96-multiwell microtiter plates and a sandwich assay with fluorescein- or Cy3-labeled reporter antibodies was used for detection. (Printing was achieved with a conventional microarray printing robot that was operated with custom-developed microplate arraying software.) Detection of the IgG was realized from ca. 5 to 25 ng/mL, and detection of E. coli O157:H7 and S. typhimurium was realized from ca. 10(6) to 10(9) and ca. 10(7) to 10(9) cells/mL, respectively. Multiplex detection of the two bacteria and the IgG in buffer and in culture-enriched ground beef filtrate was established with a total assay (including detection) time of ca. 2.5 h. Detection of S. typhimurium was largely unaffected by high concentrations of the other bacteria and IgG as well as the ground beef filtrate, whereas a small decrease in response was observed for E. coli O157:H7. The multiwell plate, multiplex antibody microarray platform developed here demonstrates a powerful approach for high-throughput screening of large numbers of food samples for multiple pathogens and toxins.


Asunto(s)
Escherichia coli O157/aislamiento & purificación , Microbiología de Alimentos , Enfermedades Transmitidas por los Alimentos/microbiología , Inmunoensayo/métodos , Análisis por Matrices de Proteínas/métodos , Salmonella typhimurium/aislamiento & purificación , Animales , Anticuerpos Antibacterianos/química , Escherichia coli O157/inmunología , Colorantes Fluorescentes , Contaminación de Alimentos/análisis , Humanos , Límite de Detección , Carne , Salmonella typhimurium/inmunología , Sensibilidad y Especificidad
3.
J Microbiol Methods ; 67(3): 527-33, 2006 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-16935371

RESUMEN

Escherichia coli O157:H7, a major foodborne pathogen, has been associated with numerous cases of foodborne illnesses. Rapid methods have been developed for the screening of this pathogen in foods in order to circumvent timely plate culture techniques. Unfortunately, many rapid methods are presumptive and do not claim to confirm the presence of E. coli O157:H7. The previously developed method, enzyme-linked immunomagnetic chemiluminescence (ELIMCL), has been improved upon to allow for fewer incidences of false positives when used to detect E. coli O157:H7 in the presence of mixed cultures. The key feature of this assay is that it combines the highly selective synergism of both anti-O157 and anti-H7 antibodies in the sandwich immunoassay format. This work presents application of a newly semi-automated version of ELIMCL to the detection of E. coli O157:H7 in pristine buffered saline yielding detection limits of approximately 1 x 10(5) to 1 x 10(6) of live cells/mL. ELIMCL was further demonstrated to detect E. coli O157:H7 inoculated into artificially contaminated ground beef at ca. 400 CFU/g after a 5 h enrichment and about 1.5 h assay time for a total detection time of about 6.5 h. Finally, ELIMCL was compared with USFDA's Bacteriological Analytical Manual method for E. coli O157:H7 in a double-blind study. Using McNemar's treatment, the two methods were determined to be statistically similar for the detection of E. coli O157:H7 in ground beef inoculated with mixed cultures of select bacteria.


Asunto(s)
Técnicas Bacteriológicas , Escherichia coli O157/clasificación , Escherichia coli O157/aislamiento & purificación , Microbiología de Alimentos , Separación Inmunomagnética , Luminiscencia , Carne/microbiología , Sensibilidad y Especificidad , Estados Unidos , United States Food and Drug Administration
4.
J Immunol Methods ; 293(1-2): 97-106, 2004 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-15541280

RESUMEN

E. coli O157:H7 is a pathogenic microorganism that has been implicated in numerous cases of foodborne illnesses. A variety of rapid methods exist that show promise for the presumptive detection of this pathogen without the immediate need for incubating test samples for hours to days in microbial enrichment and culture media. In recent years, highly sensitive chemiluminescence has become a more affordable and portable detection method. Chemiluminescent detection has been coupled with the selectivity of antibodies, magnetic microparticle separation/isolation, and enzymatic signal amplification in order to develop a rapid method, termed enzyme-linked immunomagnetic chemiluminescence (ELIMCL). This work presents the application of ELIMCL to the detection of E. coli O157:H7 in pristine buffered saline with a detection limit of 7.6 x 10(3) for live cells in approx. 75 min assay time. The blocking agent casein and the surfactant Tween 20 were used to lower background luminescence and thus maximize signal-to-noise ratios. After 5.5 h of enrichment culture, ELIMCL was demonstrated to detect E. coli O157:H7 inoculated in ground beef at 10 CFU/g in a total assay time of about 7 h.


Asunto(s)
Escherichia coli O157/aislamiento & purificación , Separación Inmunomagnética , Mediciones Luminiscentes , Ensayo de Inmunoadsorción Enzimática , Escherichia coli O157/inmunología , Factores de Tiempo
5.
Anal Chem ; 78(18): 6601-7, 2006 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-16970339

RESUMEN

A sandwich fluorescent immunoassay in a microarray format was used to capture and detect E. coli O157:H7. Here, we explored quantitative aspects, limitations, and capture efficiency of the assay. When biotinylated capture antibodies were used, the signal generated was higher (over 5-fold higher with some cell concentrations) compared to biotinylated protein G-bound capture antibodies. By adjusting the concentration of reporter antibody, a linear fluorescent response was observed from approximately 3.0 x 10(6) to approximately 9.0 x 10(7) cells/mL, and this was in agreement with the number of captured bacteria as determined by fluorescence microscopy. Capture efficiency calculations revealed that, as the number of bacteria presented for capture decreased, capture efficiency increased to near 35%. Optimization experiments, with several combinations of capture and reporter antibodies, demonstrated that the amount of bacteria available for capture (10(6) versus 10(8) cells/mL) affected the optimal combination. The findings presented here indicate that antibody microarrays, when used in sandwich assay format, may be effectively used to capture and detect E. coli O157:H7.


Asunto(s)
Anticuerpos Antibacterianos/química , Escherichia coli O157/aislamiento & purificación , Microbiología de Alimentos , Análisis por Matrices de Proteínas/métodos , Recuento de Colonia Microbiana , Microscopía Fluorescente , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA