Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Anesthesiology ; 2024 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-38768389

RESUMEN

BACKGROUND: Postoperative pulmonary complications (PPCs) can increase hospital length of stay, postoperative morbidity and mortality. Despite many factors can increase the risk of PPCs, it is not known whether intraoperative ventilation/perfusion (V/Q) mismatch can be associated with an increased risk of PPCs after major non-cardiac surgery. METHODS: We enrolled patients undergoing general anesthesia for non-cardiac surgery and evaluated intraoperative V/Q distribution using the Automatic Lung Parameter Estimator technique. The assessment was done after anesthesia induction (T1), after 1 hour from surgery start (T2) and at the end of surgery (T3). We collected demographic and procedural information and measured intraoperative ventilatory and hemodynamic parameters at each time-point. Patients were followed up for 7 days after surgery and assessed daily for PPCs occurrence. RESULTS: We enrolled 101 patients with a median age of 71 [62-77] years, a BMI of 25 [22.4-27.9] kg/m 2 and a preoperative ARISCAT score of 41 [34-47]. Of them, 29 (29%) developed PPCs, mainly acute respiratory failure (23%) and pleural effusion (11%). Patients with and without PPCs did not differ in levels of shunt at T1 (PPCs:22.4[10.4-35.9] % vs No PPCs:19.3[9.4-24.1] %, p=0.18) or during the protocol, while significantly different levels of high V/Q were found during surgery (PPCs:13[11-15] mmHg vs No PPCs:10[8-13.5] mmHg, p=0.007) and before extubation (PPCs:13[11-14]mmHg vs No PPCs:10[8-12] mmHg, p=0.006). After adjusting for age, ARISCAT, BMI, smoking, fluid balance, anesthesia type, laparoscopic procedure and surgery duration, high V/Q before extubation was independently associated with the development of PPCs (OR 1.147, CI 95% [1.021-1.289], p=0.02). The sensitivity analysis showed an E-value of 1.35 (CI=1.11). CONCLUSIONS: In patients with intermediate/high risk of PPCs undergoing major non-cardiac surgery, intraoperative V/Q mismatch is associated with the development of PPCs. Increased high V/Q before extubation is independently associated with the occurrence of PPCs in the first 7 days after surgery.

2.
J Clin Monit Comput ; 38(1): 57-67, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37968547

RESUMEN

Pulse pressure variation (PPV) is a well-established method for predicting fluid responsiveness in mechanically ventilated patients. The predictive accuracy is, however, disputed for ventilation with low tidal volume (VT) or low heart-rate-to-respiratory-rate ratio (HR/RR). We investigated the effects of VT and RR on PPV and on PPV's ability to predict fluid responsiveness. We included patients scheduled for open abdominal surgery. Prior to a 250 ml fluid bolus, we ventilated patients with combinations of VT from 4 to 10 ml kg-1 and RR from 10 to 31 min-1. For each of 10 RR-VT combinations, PPV was derived using both a classic approach and a generalized additive model (GAM) approach. The stroke volume (SV) response to fluid was evaluated using uncalibrated pulse contour analysis. An SV increase > 10% defined fluid responsiveness. Fifty of 52 included patients received a fluid bolus. Ten were fluid responders. For all ventilator settings, fluid responsiveness prediction with PPV was inconclusive with point estimates for the area under the receiver operating characteristics curve between 0.62 and 0.82. Both PPV measures were nearly proportional to VT. Higher RR was associated with lower PPV. Classically derived PPV was affected more by RR than GAM-derived PPV. Correcting PPV for VT could improve PPV's predictive utility. Low HR/RR has limited effect on GAM-derived PPV, indicating that the low HR/RR limitation is related to how PPV is calculated. We did not demonstrate any benefit of GAM-derived PPV in predicting fluid responsiveness.Trial registration: ClinicalTrials.gov, reg. March 6, 2020, NCT04298931.


Asunto(s)
Fluidoterapia , Frecuencia Respiratoria , Humanos , Presión Sanguínea/fisiología , Volumen de Ventilación Pulmonar , Fluidoterapia/métodos , Volumen Sistólico/fisiología , Pulmón , Respiración Artificial/métodos , Hemodinámica/fisiología
3.
Scand J Clin Lab Invest ; 83(3): 166-172, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36988149

RESUMEN

It has been acknowledged for years that compounds containing sulfur (S) are an important source of endogenous acid production. In the metabolism, S is oxidized to sulfate, and therefore the mEq sulfate excreted in the urine is counted as acid retained in the body. In this study we show that pH in fluids with constant [Na] and [HEPES] declines as sulfate ions are added, and we show that titratable acidity increases exactly with the equivalents of sulfate. Therefore, sulfate excretion in urine is also acid excretion per se. This is in accordance with the down-regulation of proximal sulfate reabsorption under acidosis and the observation that children with distal renal tubular acidosis may be sulfate depleted. These results are well explained using charge-balance modeling, which is based only on the three fundamental principles of electroneutrality, conservation of mass, and rules of dissociation as devised from physical chemistry. In contrast, the findings are in contrast to expectations from conventional narratives. These are unable to understand the decreasing pH as sulfate is added since no conventional acid is present. The results may undermine the traditional notion of endogenous acid production since in the case of sulfur balance, S oxidation and its excretion as sulfate exactly balance each other. Possible clinical correlates with these findings are discussed.


Asunto(s)
Equilibrio Ácido-Base , Acidosis , Niño , Humanos , Sulfatos , Acidosis/metabolismo , Sodio , Azufre , Concentración de Iones de Hidrógeno
4.
Biomed Eng Online ; 21(1): 5, 2022 Jan 24.
Artículo en Inglés | MEDLINE | ID: mdl-35073928

RESUMEN

BACKGROUND: Systems aiding in selecting the correct settings for mechanical ventilation should visualize patient information at an appropriate level of complexity, so as to reduce information overload and to make reasoning behind advice transparent. Metaphor graphics have been applied to this effect, but these have largely been used to display diagnostic and physiologic information, rather than the clinical decision at hand. This paper describes how the conflicting goals of mechanical ventilation can be visualized and applied in making decisions. Data from previous studies are analyzed to assess whether visual patterns exist which may be of use to the clinical decision maker. MATERIALS AND METHODS: The structure and screen visualizations of a commercial clinical decision support system (CDSS) are described, including the visualization of the conflicting goals of mechanical ventilation represented as a hexagon. Retrospective analysis is performed on 95 patients from 2 previous clinical studies applying the CDSS, to identify repeated patterns of hexagon symbols. RESULTS: Visual patterns were identified describing optimal ventilation, over and under ventilation and pressure support, and over oxygenation, with these patterns identified for both control and support modes of mechanical ventilation. Numerous clinical examples are presented for these patterns illustrating their potential interpretation at the bedside. CONCLUSIONS: Visual patterns can be identified which describe the trade-offs required in mechanical ventilation. These may have potential to reduce information overload and help in simple and rapid identification of sub-optimal settings.


Asunto(s)
Sistemas de Apoyo a Decisiones Clínicas , Respiración Artificial , Toma de Decisiones , Humanos , Respiración con Presión Positiva , Estudios Retrospectivos
5.
Scand J Clin Lab Invest ; 82(5): 356-362, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35792720

RESUMEN

Rational treatment and thorough diagnostic classification of acid-base disorders requires quantitative understanding of the mechanisms that generate and dissipate loads of acid and base. A natural precondition for this tallying is the ability to quantify the acid content in any specified fluid. Physical chemistry defines the pH-dependent charge on any buffer species, and also on strong ions on which, by definition, the charge is pH-invariant. Based, then, on the requirement of electroneutrality and conservation of mass, it was shown in 1914 that pH can be calculated and understood on the basis of the chemical composition of any fluid. Herein we first show that this specification for [H+] of the charge-balance model directly delivers the pH-dependent buffer-capacity as defined in the literature. Next, we show how the notion of acid transport as proposed in experimental physiology can be understood as a change in strong ion difference, ΔSID. Finally, based on Brønsted-Lowry theory we demonstrate that by defining the acid content as titratable acidity, this is equal to SIDref - SID, where SIDref is SID at pH 7.4. Thereby, any chemical situation is represented as a curve in a novel diagram with titratable acidity = SIDref - SID as a function of pH. For any specification of buffer chemistry, therefore, the change in acid content in the fluid is path invariant. Since constituents of SID and titratable acidity are additive, we thereby, based on first principles, have defined a new framework for modeling acid balance across a cell, a whole organ, or the whole-body.


Asunto(s)
Equilibrio Ácido-Base , Humanos , Equilibrio Ácido-Base/fisiología , Concentración de Iones de Hidrógeno , Iones
6.
J Clin Monit Comput ; 36(5): 1333-1340, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-34647198

RESUMEN

Hyper- or hypoventilation are commonly occurring stress responses to arterial puncture around the time of blood sampling and have been shown to rapidly alter arterial blood acid-base parameters. This study aimed to evaluate a physiology-based mathematical method to transform peripheral venous blood acid-base values into mathematically arterialised equivalents following acute, transient changes in ventilation. Data from thirty patients scheduled for elective surgery were analysed using the physiology-based method. These data described ventilator changes simulating 'hyper-' or 'hypoventilation' at arterial puncture and included acid-base status from simultaneously drawn blood samples from arterial and peripheral venous catheters at baseline and following ventilatory change. Venous blood was used to calculate mathematically arterialised equivalents using the physiology-based method; baseline values were analysed using Bland-Altman plots. When compared to baseline, measured arterial and calculated arterialised values at each time point within limits of pH: ± 0.03 and PCO2: ± 0.5 kPa, were considered 'not different from baseline'. Percentage of values considered not different from baseline were calculated at each sampling timepoint following hyper- and hypoventilation. For the physiological method, bias and limits of agreement for pH and PCO2 were -0.001 (-0.022 to 0.020) and -0.02 (-0.37 to 0.33) kPa at baseline, respectively. 60 s following a change in ventilation, 100% of the mathematically arterialised values of pH and PCO2 were not different from baseline, compared to less than 40% of the measured arterial values at the same timepoint. In clinical situations where transient breath-holding or hyperventilation may compromise the accuracy of arterial blood samples, arterialised venous blood is a stable representative of steady state arterial blood.


Asunto(s)
Dióxido de Carbono , Cateterismo Periférico , Análisis de los Gases de la Sangre/métodos , Cateterismo Periférico/métodos , Humanos , Concentración de Iones de Hidrógeno , Respiración , Venas
7.
Respiration ; 100(2): 164-172, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33494091

RESUMEN

BACKGROUND: Arterial blood gases are important when assessing acute or critically ill patients. Capillary blood and mathematical arterialization of venous blood have been proposed as alternative methods, eliminating pain and complications of arterial puncture. OBJECTIVES: This study compares the arterial samples, arterialized venous samples, and capillary samples in ICU and pulmonary ward patients. METHOD: Ninety-one adult patients with respiratory failure were included in the analysis. Arterial, peripheral venous, and mathematically arterialized venous samples were compared in all patients using Bland-Altman analysis, with capillary samples included in 36 patients. RESULTS: Overall for pH and PCO2, arterialized venous values, and in the subset of 36 patients, capillary values, compared well to arterial values and were within the pre-defined clinically acceptable differences (pH ± 0.05 and PCO2 ± 0.88 kPa). For PO2, arterialized or capillary values describe arterial with similar precision (PO2 arterialized -0.03, LoA -1.48 to 1.42 kPa and PO2 capillary 0.82, LoA -1.36 to 3 kPa), with capillary values underestimating arterial. CONCLUSIONS: Mathematical arterialization functions well in a range of patients in an ICU and ward outside the country of development of the method. Furthermore, accuracy and precision are similar to capillary blood samples. When considering a replacement for arterial sampling in ward patients, using capillary sampling or mathematical arterialization should depend on logistic ease of implementation and use rather than improved measurements of using either technique.


Asunto(s)
Análisis de los Gases de la Sangre/métodos , Dióxido de Carbono/sangre , Concentración de Iones de Hidrógeno , Conceptos Matemáticos , Oxígeno/sangre , Adulto , Anciano , Arterias , Enfermedad Crítica , Femenino , Humanos , Unidades de Cuidados Intensivos , Masculino , Persona de Mediana Edad , Venas
8.
J Clin Monit Comput ; 35(5): 1149-1157, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-32816177

RESUMEN

During one-lung ventilation (OLV), titrating the positive end-expiratory pressure (PEEP) to target a low driving pressure (∆P) could reduce postoperative pulmonary complications. However, it is unclear how to conduct PEEP titration: by stepwise increase starting from zero PEEP (PEEPINCREMENTAL) or by stepwise decrease after a lung recruiting manoeuvre (PEEPDECREMENTAL). In this randomized trial, we compared the physiological effects of these two PEEP titration strategies on respiratory mechanics, ventilation/perfusion mismatch and gas exchange. Patients undergoing video-assisted thoracoscopic surgery in OLV were randomly assigned to a PEEPINCREMENTAL or PEEPDECREMENTAL strategy to match the lowest ∆P. In the PEEPINCREMENTAL group, PEEP was stepwise titrated from ZEEP up to 16 cm H2O, whereas in the PEEPDECREMENTAL group PEEP was decrementally titrated, starting from 16 cm H2O, immediately after a lung recruiting manoeuvre. Respiratory mechanics, ventilation/perfusion mismatch and blood gas analyses were recorded at baseline, after PEEP titration and at the end of surgery. Sixty patients were included in the study. After PEEP titration, shunt decreased similarly in both groups, from 50 [39-55]% to 35 [28-42]% in the PEEPINCREMENTAL and from 45 [37-58]% to 33 [25-45]% in the PEEPDECREMENTAL group (both p < 0.001 vs baseline). The resulting ∆P, however, was lower in the PEEPDECREMENTAL than in the PEEPINCREMENTAL group (8 [7-11] vs 10 [9-11] cm H2O; p = 0.03). In the PEEPDECREMENTAL group the PaO2/ FIO2 ratio increased significantly after intervention (from 140 [99-176] to 186 [152-243], p < 0.001). Both the PEEPINCREMENTAL and the PEEPDECREMENTAL strategies were able to decrease intraoperative shunt, but only PEEPDECREMENTAL improved oxygenation and lowered intraoperative ΔP.Clinical trial number NCT03635281; August 2018; "retrospectively registered".


Asunto(s)
Ventilación Unipulmonar , Humanos , Pulmón , Rendimiento Pulmonar , Respiración con Presión Positiva , Mecánica Respiratoria
9.
Crit Care ; 24(1): 111, 2020 03 23.
Artículo en Inglés | MEDLINE | ID: mdl-32293506

RESUMEN

BACKGROUND: Several studies have found only a weak to moderate correlation between oxygenation and lung aeration in response to changes in PEEP. This study aimed to investigate the association between changes in shunt, low and high ventilation/perfusion (V/Q) mismatch, and computed tomography-measured lung aeration following an increase in PEEP in patients with ARDS. METHODS: In this preliminary study, 12 ARDS patients were subjected to recruitment maneuvers followed by setting PEEP at 5 and then either 15 or 20 cmH2O. Lung aeration was measured by computed tomography. Values of pulmonary shunt and low and high V/Q mismatch were calculated by a model-based method from measurements of oxygenation, ventilation, and metabolism taken at different inspired oxygen levels and an arterial blood gas sample. RESULTS: Increasing PEEP resulted in reduced values of pulmonary shunt and the percentage of non-aerated tissue, and an increased percentage of normally aerated tissue (p < 0.05). Changes in shunt and normally aerated tissue were significantly correlated (r = - 0.665, p = 0.018). Three distinct responses to increase in PEEP were observed in values of shunt and V/Q mismatch: a beneficial response in seven patients, where shunt decreased without increasing high V/Q; a detrimental response in four patients where both shunt and high V/Q increased; and a detrimental response in a patient with reduced shunt but increased high V/Q mismatch. Non-aerated tissue decreased with increased PEEP in all patients, and hyperinflated tissue increased only in patients with a detrimental response in shunt and V/Q mismatch. CONCLUSIONS: The results show that improved lung aeration following an increase in PEEP is not always consistent with reduced shunt and V/Q mismatch. Poorly matched redistribution of ventilation and perfusion, between dependent and non-dependent regions of the lung, may explain why patients showed detrimental changes in shunt and V/Q mismatch on increase in PEEP, despite improved aeration. TRIAL REGISTRATION: ClinicalTrails.gov, NCT04067154. Retrospectively registered on August 26, 2019.


Asunto(s)
Respiración con Presión Positiva/métodos , Síndrome de Dificultad Respiratoria/fisiopatología , Tomografía Computarizada por Rayos X/métodos , Relación Ventilacion-Perfusión/fisiología , Adulto , Anciano , Análisis de los Gases de la Sangre/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Respiración con Presión Positiva/instrumentación , Estudios Prospectivos , Síndrome de Dificultad Respiratoria/complicaciones
10.
Crit Care Med ; 46(7): e642-e648, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29629989

RESUMEN

OBJECTIVES: To evaluate the physiologic effects of applying advice on mechanical ventilation by an open-loop, physiologic model-based clinical decision support system. DESIGN: Prospective, observational study. SETTING: University and Regional Hospitals' ICUs. PATIENTS: Varied adult ICU population. INTERVENTIONS: Advice were applied if accepted by physicians for a period of up to 4-8 hours. MEASUREMENTS AND MAIN RESULTS: Seventy-two patients were included for data analysis. Acceptance of advice was high with 95.7% of advice applied. In 41 patients in pressure support ventilation, following system advice led to significant decrease in PS, with PS reduced below 8 cm H2O in 15 patients (37%), a level not prohibiting extubation. Fraction of end-tidal CO2 values did not change, and increase in respiratory rate/VT was within clinical limits, indicating that in general, the system maintained appropriate patient breathing effort. In 31 patients in control mode ventilation, pressure control and tidal volume settings were decreased significantly, with tidal volume reduced below 8 mL/kg predicted body weight in nine patients (29%). Minute ventilation was maintained by a significant increase in respiratory rate. Significant reductions in FIO2 were seen on elevated baseline median values of 50% in both support and control mode-ventilated patients, causing clinically acceptable reductions in oxygen saturation. CONCLUSIONS: The results indicate that during a short period, the clinical decision support system provided appropriate suggestions of mechanical ventilation in a varied ICU population, significantly reducing ventilation to levels which might be considered safe and beneficial.


Asunto(s)
Sistemas de Apoyo a Decisiones Clínicas , Respiración Artificial/métodos , Técnicas de Apoyo para la Decisión , Humanos , Unidades de Cuidados Intensivos , Estudios Prospectivos , Reproducibilidad de los Resultados , Fenómenos Fisiológicos Respiratorios
11.
Anesthesiology ; 128(3): 531-538, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29215365

RESUMEN

BACKGROUND: Arterial oxygenation is often impaired during one-lung ventilation, due to both pulmonary shunt and atelectasis. The use of low tidal volume (VT) (5 ml/kg predicted body weight) in the context of a lung-protective approach exacerbates atelectasis. This study sought to determine the combined physiologic effects of positive end-expiratory pressure and low VT during one-lung ventilation. METHODS: Data from 41 patients studied during general anesthesia for thoracic surgery were collected and analyzed. Shunt fraction, high V/Q and respiratory mechanics were measured at positive end-expiratory pressure 0 cm H2O during bilateral lung ventilation and one-lung ventilation and, subsequently, during one-lung ventilation at 5 or 10 cm H2O of positive end-expiratory pressure. Shunt fraction and high V/Q were measured using variation of inspired oxygen fraction and measurement of respiratory gas concentration and arterial blood gas. The level of positive end-expiratory pressure was applied in random order and maintained for 15 min before measurements. RESULTS: During one-lung ventilation, increasing positive end-expiratory pressure from 0 cm H2O to 5 cm H2O and 10 cm H2O resulted in a shunt fraction decrease of 5% (0 to 11) and 11% (5 to 16), respectively (P < 0.001). The PaO2/FIO2 ratio increased significantly only at a positive end-expiratory pressure of 10 cm H2O (P < 0.001). Driving pressure decreased from 16 ± 3 cm H2O at a positive end-expiratory pressure of 0 cm H2O to 12 ± 3 cm H2O at a positive end-expiratory pressure of 10 cm H2O (P < 0.001). The high V/Q ratio did not change. CONCLUSIONS: During low VT one-lung ventilation, high positive end-expiratory pressure levels improve pulmonary function without increasing high V/Q and reduce driving pressure.


Asunto(s)
Pulmón/fisiología , Ventilación Unipulmonar/métodos , Respiración con Presión Positiva/métodos , Mecánica Respiratoria/fisiología , Anciano , Femenino , Humanos , Italia , Masculino , Persona de Mediana Edad , Intercambio Gaseoso Pulmonar/fisiología , Volumen de Ventilación Pulmonar/fisiología
12.
Chron Respir Dis ; 12(4): 357-64, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26323278

RESUMEN

Gas exchange impairment is primarily caused by ventilation-perfusion mismatch in chronic obstructive pulmonary disease (COPD), where diffusing capacity of the lungs for carbon monoxide (DLCO) remains the clinical measure. This study investigates whether DLCO: (1) can predict respiratory impairment in COPD, that is, changes in oxygen and carbon dioxide (CO2); (2) is associated with combined risk assessment score for COPD (Global Initiative for Chronic Obstructive Lung Disease (GOLD) score); and (3) is associated with blood glucose and body mass index (BMI). Fifty patients were included retrospectively. DLCO; arterial blood gas at inspired oxygen (FiO2) = 0.21; oxygen saturation (SpO2) at FiO2 = 0.21 (SpO2 (21)) and FiO2 = 0.15 (SpO2 (15)) were registered. Difference between arterial and end-tidal CO2 (ΔCO2) was calculated. COPD severity was stratified according to GOLD score. The association between DLCO, SpO2, ΔCO2, GOLD score, blood glucose, and BMI was investigated. Multiple regression showed association between DLCO and GOLD score, BMI, and glucose level (R (2) = 0.6, p < 0.0001). Linear and multiple regression showed an association between DLCO and SpO2 (21) (R (2) = 0.3, p = 0.001 and p = 0.03, respectively) without contribution from SpO2 (15) or ΔCO2. A stronger association between DLCO and GOLD score than between DLCO and SpO2 could indicate that DLCO is more descriptive of systemic deconditioning than gas exchange in COPD patients. However, further larger studies are needed. A weaker association is seen between DLCO and SpO2 (21) without contribution from SpO2 (15) and ΔCO2. This could indicate that DLCO is more descriptive of systemic deconditioning than gas exchange in COPD patients. However, further larger studies are needed.


Asunto(s)
Dióxido de Carbono/metabolismo , Oxígeno/metabolismo , Capacidad de Difusión Pulmonar , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Intercambio Gaseoso Pulmonar/fisiología , Insuficiencia Respiratoria/fisiopatología , Anciano , Análisis de los Gases de la Sangre , Glucemia/metabolismo , Monóxido de Carbono , Estudios de Cohortes , Femenino , Volumen Espiratorio Forzado , Humanos , Modelos Lineales , Masculino , Persona de Mediana Edad , Análisis Multivariante , Oximetría , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico , Enfermedad Pulmonar Obstructiva Crónica/metabolismo , Insuficiencia Respiratoria/diagnóstico , Insuficiencia Respiratoria/metabolismo , Estudios Retrospectivos , Índice de Severidad de la Enfermedad
13.
Expert Rev Respir Med ; : 1-7, 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-38973767

RESUMEN

BACKGROUND: Several methods exist to reduce the number of arterial blood gases (ABGs). One method, Roche v-TAC, has been evaluated in different patient groups. This paper aggregates data from these studies, in different patient categories using common analysis criteria. RESEARCH DESIGN AND METHODS: We included studies evaluating v-TAC based on paired arterial and peripheral venous blood samples. Bland-Altman analysis compared measured and calculated arterial values of pH, PCO2, and PO2. Subgroup analyses were performed for normal, chronic hypercapnia and chronic base excess, acute hyper- and hypocapnia, and acute and chronic base deficits. RESULTS: 811 samples from 12 studies were included. Bias and limits of agreement for measured and calculated values: pH 0.001 (-0.029 to 0.031), PCO2 -0.08 (-0.65 to 0.49) kPa, and PO2 0.04 (-1.71 to 1.78) kPa, with similar values for all sub-group analyses. CONCLUSION: These data suggest that v-TAC analysis may have a role in replacing ABGs, avoiding arterial puncture. Substantial data exist in patients with chronic hypercapnia and chronic base excess, acute hyper- and hypocapnia, and in patients with relatively normal acid-base status, with similar bias and precision across groups and across study data. Limited data exist for patients with acute and chronic base deficits.

14.
Intensive Care Med Exp ; 11(1): 41, 2023 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-37415048

RESUMEN

BACKGROUND: Diaphragmatic dysfunction is well documented in patients receiving mechanical ventilation. Inspiratory muscle training (IMT) has been used to facilitate weaning by strengthening the inspiratory muscles, yet the optimal approach remains uncertain. Whilst some data on the metabolic response to whole body exercise in critical care exist, the metabolic response to IMT in critical care is yet to be investigated. This study aimed to quantify the metabolic response to IMT in critical care and its relationship to physiological variables. METHODS: We conducted a prospective observational study on mechanically ventilated patients ventilated for ≥ 72 h and able to participate in IMT in a medical, surgical, and cardiothoracic intensive care unit. 76 measurements were taken on 26 patients performing IMT using an inspiratory threshold loading device at 4 cmH2O, and at 30, 50 and 80% of their negative inspiratory force (NIF). Oxygen consumption (VO2) was measured continuously using indirect calorimetry. RESULTS: First session mean (SD) VO2 was 276 (86) ml/min at baseline, significantly increasing to 321 (93) ml/min, 333 (92) ml/min, 351(101) ml/min and 388 (98) ml/min after IMT at 4 cmH2O and 30, 50 and 80% NIF, respectively (p = 0.003). Post hoc comparisons revealed significant differences in VO2 between baseline and 50% NIF and baseline and 80% NIF (p = 0.048 and p = 0.001, respectively). VO2 increased by 9.3 ml/min for every 1 cmH2O increase in inspiratory load from IMT. Every increase in P/F ratio of 1 decreased the intercept VO2 by 0.41 ml/min (CI - 0.58 to - 0.24 p < 0.001). NIF had a significant effect on the intercept and slope, with every 1 cmH2O increase in NIF increasing intercept VO2 by 3.28 ml/min (CI 1.98-4.59 p < 0.001) and decreasing the dose-response slope by 0.15 ml/min/cmH2O (CI - 0.24 to - 0.05 p = 0.002). CONCLUSIONS: IMT causes a significant load-dependent increase in VO2. P/F ratio and NIF impact baseline VO2. The dose-response relationship of the applied respiratory load during IMT is modulated by respiratory strength. These data may offer a novel approach to prescription of IMT. TAKE HOME MESSAGE: The optimal approach to IMT in ICU is uncertain; we measured VO2 at different applied respiratory loads to assess whether VO2 increased proportionally with load and found VO2 increased by 9.3 ml/min for every 1 cmH2O increase in inspiratory load from IMT. Baseline NIF has a significant effect on the intercept and slope, participants with a higher baseline NIF have a higher resting VO2 but a less pronounced increase in VO2 as the inspiratory load increases; this may offer a novel approach to IMT prescription. Trial registration ClinicalTrials.gov, registration number: NCT05101850. Registered on 28 September 2021, https://clinicaltrials.gov/ct2/show/NCT05101850.

15.
BMJ Open Respir Res ; 10(1)2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37369550

RESUMEN

BACKGROUND: Accurate arterial blood gas (ABG) analysis is essential in the management of patients with hypercapnic respiratory failure, but repeated sampling requires technical expertise and is painful. Missed sampling is common and has a negative impact on patient care. A newer venous to arterial conversion method (v-TAC, Roche) uses mathematical models of acid-base chemistry, a venous blood gas sample and peripheral blood oxygen saturation to calculate arterial acid-base status. It has the potential to replace routine ABG sampling for selected patient cohorts. The aim of this study was to compare v-TAC with ABG, capillary and venous sampling in a patient cohort referred to start non-invasive ventilation (NIV). METHODS: Recruited patients underwent near simultaneous ABG, capillary blood gas (CBG) and venous blood gas (VBG) sampling at day 0, and up to two further occasions (day 1 NIV and discharge). The primary outcome was the reliability of v-TAC sampling compared with ABG, via Bland-Altman analysis, to identify respiratory failure (via PaCO2) and to detect changes in PaCO2 in response to NIV. Secondary outcomes included agreements with pH, sampling success rates and pain. RESULTS: The agreement between ABG and v-TAC/venous PaCO2 was assessed for 119 matched sampling episodes and 105 between ABG and CBG. Close agreement was shown for v-TAC (mean difference (SD) 0.01 (0.5) kPa), but not for CBG (-0.75 (0.69) kPa) or VBG (+1.00 (0.90) kPa). Longitudinal data for 32 patients started on NIV showed the closest agreement for ABG and v-TAC (R2=0.61). v-TAC sampling had the highest first-time success rate (88%) and was less painful than arterial (p<0.0001). CONCLUSION: Mathematical arterialisation of venous samples was easier to obtain and less painful than ABG sampling. Results showed close agreement for PaCO2 and pH and tracked well longitudinally such that the v-TAC method could replace routine ABG testing to recognise and monitor patients with hypercapnic respiratory failure. TRIAL REGISTRATION NUMBER: NCT04072848; www. CLINICALTRIALS: gov.


Asunto(s)
Dióxido de Carbono , Insuficiencia Respiratoria , Humanos , Adulto , Estudios Longitudinales , Reproducibilidad de los Resultados , Insuficiencia Respiratoria/diagnóstico , Insuficiencia Respiratoria/etiología , Insuficiencia Respiratoria/terapia , Estudios de Cohortes
16.
Respir Care ; 2022 Nov 08.
Artículo en Inglés | MEDLINE | ID: mdl-36347564

RESUMEN

BACKGROUND: COVID-19-related ARDS is characterized by severe hypoxemia with initially preserved lung compliance and impaired ventilation/perfusion (V̇/Q̇) matching. PEEP can increase end-expiratory lung volume, but its effect on V̇/Q̇ mismatch in COVID-19-related ARDS is not clear. METHODS: We enrolled intubated and mechanically ventilated subjects with COVID-19 ARDS and used the automatic lung parameter estimator (ALPE) to measure V̇/Q̇. Respiratory mechanics measurements, shunt, and V̇/Q̇ mismatch (low V̇/Q̇ and high V̇/Q̇) were collected at 3 PEEP levels (clinical PEEP = intermediate PEEP, low PEEP [clinical - 50%], and high PEEP [clinical + 50%]). A mixed-effect model was used to evaluate the impact of PEEP on V̇/Q̇. We also investigated if PEEP might have a different effect on V̇/Q̇ mismatch in 2 different respiratory mechanics phenotypes, that is, high elastance/low compliance (phenotype H) and low elastance/high compliance (phenotype L). RESULTS: Seventeen subjects with COVID-related ARDS age 66 [60-71] y with a PaO2 /FIO2 of 141 ± 74 mm Hg were studied at low PEEP = 5.6 ± 2.2 cm H2O, intermediate PEEP = 10.6 ± 3.8 cm H2O, and high PEEP = 15 ± 5 cm H2O. Shunt, low V̇/Q̇, high V̇/Q̇, and alveolar dead space were not significantly influenced, on average, by PEEP. Respiratory system compliance decreased significantly when increasing PEEP without significant variation of PaO2 /FIO2 (P = .26). In the 2 phenotypes, PEEP had opposite effects on shunt, with a decrease in the phenotype L and an increase in phenotype H (P = .048). CONCLUSIONS: In subjects with COVID-related ARDS placed on invasive mechanical ventilation for > 48 h, PEEP had a heterogeneous effect on V̇/Q̇ mismatch and, on average, higher levels were not able to reduce shunt. The subject's compliance could influence the effect of PEEP on V̇/Q̇ mismatch since an increased shunt was observed in subjects with lower compliance, whereas the opposite occurred in those with higher compliance.

17.
Comput Methods Programs Biomed ; 203: 106022, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33713960

RESUMEN

BACKGROUND: Assessment of the critically ill patient requires arterial acid-base status. Venous blood could provide a surrogate, with methods transforming venous values to arterial, improving their utility. This manuscript compares two of these methods, a statistical and a physiological method. Where these methods are inadequate to describe critically ill patients, physiological mechanisms are explored to explain discrepancies. METHODS: 1109 paired arterial and central-venous blood samples, from patients diagnosed with acute circulatory failure, were available for retrospective analysis. Of these, 386 samples were used previously to validate the statistical model. The statistical method of Boulain et al. 2016 and the physiological method of Rees et al. 2006 were applied to the 386 sample pairs, and compared using Bland-Altman analysis. A subset of the 1109 samples, where the physiological method could not accurately calculate arterial values, were analysed further to assess the necessary addition of CO2 or strong acid at the tissues to account for arterio-venous differences. RESULTS: Bias (LoA) for comparison of calculated and measured arterial values (n = 386) were similar for the statistical method (pH: -0.003 (-0.051 to 0.045), PCO2: -0.02 (-1.33 to 1.29 kPa)) and physiological method (pH: 0.009 (-0.033 to 0.052), PCO2: -0.08 (-1.20 to 1.03 kPa)). In the 381 cases (of the 1109 sample pairs) defined as not accurately described, addition of a median CO2 concentration of 0.72 mmol/l in excess of aerobic metabolism, explained this for 333 cases, with the remainder requiring simultaneous strong acid transport. CONCLUSION: Both methods appear equal in their ability to transform central-venous values to arterial, albeit warranting caution when using either in a critically ill population. The physiological approach was able to describe arterio-venous differences not explained by aerobic metabolism alone.


Asunto(s)
Enfermedad Crítica , Venas , Arterias , Análisis de los Gases de la Sangre , Humanos , Concentración de Iones de Hidrógeno , Estudios Retrospectivos , Venas/diagnóstico por imagen
18.
BMJ Open Respir Res ; 8(1)2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33737311

RESUMEN

BACKGROUND: Early diagnosis of shock is a predetermining factor for a good prognosis in intensive care. An elevated central venous to arterial PCO2 difference (∆PCO2) over 0.8 kPa (6 mm Hg) is indicative of low blood flow states. Disturbances around the time of blood sampling could result in inaccurate calculations of ∆PCO2, thereby misrepresenting the patient status. This study aimed to determine the influences of acute changes in ventilation on ∆PCO2 and understand its clinical implications. METHODS: To investigate the isolated effects of changes in ventilation on ∆PCO2, eight pigs were studied in a prospective observational cohort. Arterial and central venous catheters were inserted following anaesthetisation. Baseline ventilator settings were titrated to achieve an EtCO2 of 5±0.5 kPa (VT = 8 mL/kg, Freq = 14 ± 2/min). Blood was sampled simultaneously from both catheters at baseline and 30, 60, 90, 120, 180 and 240 s after a change in ventilation. Pigs were subjected to both hyperventilation and hypoventilation, wherein the respiratory frequency was doubled or halved from baseline. ∆PCO2 changes from baseline were analysed using repeated measures ANOVA with post-hoc analysis using Bonferroni's correction. RESULTS: ∆PCO2 at baseline for all pigs was 0.76±0.29 kPa (5.7±2.2 mm Hg). Following hyperventilation, there was a rapid increase in the ∆PCO2, increasing maximally to 1.35±0.29 kPa (10.1±2.2 mm Hg). A corresponding decrease in the ∆PCO2 was seen following hypoventilation, decreasing maximally to 0.23±0.31 kPa (1.7±2.3 mm Hg). These changes were statistically significant from baseline 30 s after the change in ventilation. CONCLUSION: Disturbances around the time of blood sampling can rapidly affect the PCO2, leading to inaccurate calculations of the ∆PCO2, resulting in misinterpretation of patient status. Care should be taken when interpreting blood gases, if there is doubt as to the presence of acute and transient changes in ventilation.


Asunto(s)
Dióxido de Carbono , Respiración , Animales , Análisis de los Gases de la Sangre , Humanos , Porcinos
19.
Eur J Appl Physiol ; 108(3): 483-94, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19841930

RESUMEN

Mathematical models of the acid-base chemistry of blood based upon mass action and mass balance equations have become popular as diagnostic tools in intensive care. The reference models using this approach are those based on the strong ion approach, but these models do not currently take into account the effects of oxygen on the buffering characteristics of haemoglobin. As such these models are limited in their ability to simulate physiological situations involving simultaneous changes of O(2) and CO(2) levels in the blood. This paper describes a model of acid-base chemistry of blood based on mass action and mass balance equations and including the effects of oxygen. The model is used to simulate the mixing of venous blood with the same blood at elevated O(2) and reduced CO(2) levels, and the results compared with the mixing of blood sampled from 21 healthy subjects. Simulated values of pH, PCO(2), PO(2) and SO(2) in the mixed blood compare well with measured values with small bias (i.e. 0.000 pH, -0.06 kPa PCO(2), -0.1% SO(2), -0.02 kPa PO(2)), and values of standard deviations (i.e. 0.006 pH, 0.11 kPa PCO(2), 0.8% SO(2), 0.13 kPa PO(2)) comparable to the precision seen in direct measurement of these variables in clinical practice. These results indicate that the model can reliably simulate the mixing of blood and has potential for application in describing physiological situations involving the mixing of blood at different O(2) and CO(2) levels such as occurs in the mixing of lung capillary and shunted pulmonary blood.


Asunto(s)
Equilibrio Ácido-Base/fisiología , Eritrocitos/metabolismo , Modelos Teóricos , Oxígeno/sangre , Plasma/metabolismo , Dióxido de Carbono/sangre , Humanos , Concentración de Iones de Hidrógeno , Lactatos/sangre
20.
Respir Physiol Neurobiol ; 280: 103486, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32615271

RESUMEN

PURPOSE: This study evaluates agreement between carbon dioxide measured arterial (PaCO2) and transcutaneous (PtcCO2) over time, by repeated successive measures, taking into consideration the inherent variability of arterial measurements. METHODS AND RESULTS: 11 patients receiving LTOT, with severe to very severe COPD in a stable phase were studied. Repeated arterial blood samples were drawn and PtcCO2 measured simultaneously at the ear lobe. Bland-Altman analysis was used to evaluate 95 % limits of agreement (LoA). 194 paired samples were analysed. Following correction for bias, the difference between PaCO2 and PtCO2 during dynamic conditions was 0.02 kPa and LoA 0.94 to -0.90 kPa while 29 % of PtCO2 measurements were outside the range of variability for arterial measurements. CONCLUSION: PtcCO2 corrected for intra-patient bias provide reasonable description of PaCO2 values within but not outside steady state conditions. Our results suggest that PtcCO2 is a valuable method for monitoring in chronic rather than acute conditions when bias can be removed.


Asunto(s)
Análisis de los Gases de la Sangre , Monitoreo de Gas Sanguíneo Transcutáneo , Dióxido de Carbono/sangre , Enfermedad Pulmonar Obstructiva Crónica/sangre , Insuficiencia Respiratoria/sangre , Anciano , Dióxido de Carbono/metabolismo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Terapia por Inhalación de Oxígeno , Enfermedad Pulmonar Obstructiva Crónica/metabolismo , Enfermedad Pulmonar Obstructiva Crónica/terapia , Reproducibilidad de los Resultados , Insuficiencia Respiratoria/metabolismo , Insuficiencia Respiratoria/terapia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA