Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
J Arthroplasty ; 30(1): 46-9, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25304937

RESUMEN

In a retrospective study with a population over 65 years, sports activity was conducted 6 years after cruciate retaining (CR) total condylar knee arthroplasty (TKA) with rotating platform (RP). Eighty-one Patients (71.8±5.4years) were examined at follow-up 6.4±0.9 years postoperative. Sport was practiced 5.3 hours every week in mean. Patients were active in sports 3.5times per week. Twenty-five percent performed high impact sports, 47% medium impact sports and 52% low impact sports at follow-up. In KOOS sports 60±28 was reached, in WOMAC 12.1±15.1. It can be concluded that in this population 50% of patients were active in medium and low impact sport 6 years after surgery. However, a quarter of patients were also active in high impact sports.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Deportes , Factores de Edad , Anciano , Femenino , Humanos , Masculino , Recuperación de la Función , Estudios Retrospectivos , Resultado del Tratamiento
2.
Int Orthop ; 38(7): 1379-86, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24604621

RESUMEN

PURPOSE: The aim of this study was to evaluate laxity in knees with pre-operative (preop) valgus alignment compared to knees with pre-operative varus alignment after total knee arthroplasty (TKA). METHODS: This was a retrospective study including 81 patients, with six years follow-up, for pre-operative valgus- or varus alignment of the leg. All patients had been supplied with the same cruciate retaining (CR) TKA with rotating platform. Clinical findings were assessed by KSS, OKS and IKDC 2000 score. Rotational knee laxity was evaluated by a validated instrument (Laxitester®) with 2 Nm torque in 30° flexion. Collateral ligament laxity was tested manually in 30° flexion with a bending moment of approximately 5 Nm. Biomechanical results were compared to the contralateral side. RESULTS: Thirty-one patients had a preop valgus alignment of 8.96° and 50 patients a varus leg axis of 4.99° in the mean. In the preop valgus knees rotational analysis showed an increased laxity of 10.7° compared to preop varus knees (p = 0.001). There was no significant difference in medial (valgus 2.6 mm, varus 2.5 mm) and lateral (valgus 2.8 mm, varus 2.7 mm) laxity. KSS and OKS showed no significant differences in the follow-up results. In the IKDC 2000 objective score 50 % of the preop varus knees and 25.8 % of the preop valgus knees were classified as nearly normal. The difference in the IKDC objective was highly significant (p < 0.001). CONCLUSION: Preop valgus knees show a significantly increased rotational laxity but no increased collateral ligament laxity compared to pre-operative varus knees six years after TKA with rotating platform. There is a significant difference in IKDC objective.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/efectos adversos , Inestabilidad de la Articulación/diagnóstico , Prótesis de la Rodilla/efectos adversos , Anciano , Desviación Ósea/cirugía , Ligamentos Colaterales/fisiopatología , Ligamentos Colaterales/cirugía , Femenino , Humanos , Inestabilidad de la Articulación/etiología , Articulación de la Rodilla/cirugía , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Estudios Retrospectivos , Rotación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA