RESUMEN
OBJECTIVES: The prognosis of bone and joint infections (BJI) caused by Gram-negative bacilli (GNB) worsens significantly in the face of fluoroquinolone-resistance. In this setting, scarce pre-clinical and clinical reports suggest that intravenous beta-lactams plus colistin may improve outcome. Our aim was to assess the efficacy and safety of this treatment in a well-characterized prospective cohort. METHODS: Observational, prospective, non-comparative, multicenter (14 hospitals) study of adults with BJI caused by fluoroquinolone-resistant GNB treated with surgery and intravenous beta-lactams plus colistin for ≥ 21 days. The primary endpoint was the cure rate. RESULTS: Of the 44 cases included (median age 72 years [IQR 50-81], 22 [50%] women), 32 (73%) had an orthopedic device-related infection, including 17 (39%) prosthetic joints. Enterobacterales were responsible for 27 (61%) episodes, and Pseudomonas spp for 17 (39%), with an overall rate of MDR/XDR GNB infections of 27/44 (61%). Patients were treated with colistin plus intravenous beta-lactam for 28 days (IQR 22-37), followed by intravenous beta-lactam alone for 19 days (IQR 5-35). The cure rate (intention-to-treat analysis; median follow-up = 24 months, IQR 19-30) was 82% (95% CI 68%-90%) and particularly, 80% (95% CI 55%-93%) among patients managed with implant retention. Adverse events (AEs) leading to antimicrobial withdrawal occurred in 10 (23%) cases, all of which were reversible. Colistin AEs were associated with higher plasma drug concentrations (2.8 mg/L vs. 0.9 mg/L, p = 0.0001). CONCLUSIONS: Combination therapy with intravenous beta-lactams plus colistin is an effective regimen for BJI caused by fluoroquinolone-resistant GNB. AEs were reversible and potentially preventable by close therapeutic drug monitoring.
RESUMEN
OBJECTIVES: Developing procedures based on equilibrium dialysis (ED) that allow measuring the free drug concentration in plasma improves therapeutic drug monitoring (TDM) in those cases where its measurement is justified. However, this procedure requires specific sample preparation and presents different pitfalls, which are not error-free. As with any result provided by a clinical laboratory, this one should be as accurate as possible to allow a correct clinical interpretation. The measurement uncertainty (MU) is a parameter that enables the accuracy of results to be known, and that is mandated by ISO 15189. Herein, this study suggests how the MU for the results of the free drug concentrations in serum could be estimated when an ED is used. METHODS: A combination of the top-down and bottom-up approaches was used to estimate the MU based on the ISO/TS 20914:2019 and JCGM 100:2008 guidelines, including the concentration of free phenytoin in serum, as an example. Different scenarios were incorporated considering or not a significant bias related to the primary drawbacks of ED: the non-specific binding, the volume shift effect and the Gibbs-Donnan effect. RESULTS: The expanded uncertainties estimated ranged between 13.0 and 30.9â¯%. The highest MU corresponded to the free drug concentrations in serum results when significant biases related to the volume shift and Gibbs-Donnan effects exist. CONCLUSIONS: A detailed estimation of MU for free drug concentrations is presented using ED, considering different scenarios. This study could stimulate clinical laboratories to perform MU studies and its application in TDM.
Asunto(s)
Servicios de Laboratorio Clínico , Laboratorios Clínicos , Humanos , Incertidumbre , Diálisis Renal , SueroRESUMEN
For three decades, tacrolimus (Tac) dose adjustment in clinical practice has been calculated empirically according to the manufacturer's labeling based on a patient's body weight. Here, we developed and validated a Population pharmacokinetic (PPK) model including pharmacogenetics (cluster CYP3A4/CYP3A5), age, and hematocrit. Our study aimed to assess the clinical applicability of this PPK model in the achievement of Tac Co (therapeutic trough Tac concentration) compared to the manufacturer's labelling dosage. A prospective two-arm, randomized, clinical trial was conducted to determine Tac starting and subsequent dose adjustments in 90 kidney transplant recipients. Patients were randomized to a control group with Tac adjustment according to the manufacturer's labeling or the PPK group adjusted to reach target Co (6-10 ng/ml) after the first steady state (primary endpoint) using a Bayesian prediction model (NONMEM). A significantly higher percentage of patients from the PPK group (54.8%) compared with the control group (20.8%) achieved the therapeutic target fulfilling 30% of the established superiority margin defined. Patients receiving PPK showed significantly less intra-patient variability compared to the control group, reached the Tac Co target sooner (5 days vs 10 days), and required significantly fewer Tac dose modifications compared to the control group within 90 days following kidney transplant. No statistically significant differences occurred in clinical outcomes. Thus, PPK-based Tac dosing offers significant superiority for starting Tac prescription over classical labeling-based dosing according to the body weight, which may optimize Tac-based therapy in the first days following transplantation.
Asunto(s)
Trasplante de Riñón , Tacrolimus , Humanos , Teorema de Bayes , Genotipo , Inmunosupresores/uso terapéutico , Trasplante de Riñón/efectos adversos , Estudios Prospectivos , Tacrolimus/uso terapéutico , Receptores de TrasplantesRESUMEN
A major concern of human immunodeficiency virus (HIV) dual therapy is a potentially lower efficacy in viral reservoirs, especially in the central nervous system (CNS). We evaluated HIV RNA, neuronal injury, and inflammatory biomarkers and dolutegravir (DTG) exposure in cerebrospinal fluid (CSF) in patients switching to DTG plus lamivudine (3TC). All participants maintained viral suppression in plasma and CSF at week 48. We observed no increase in CSF markers of inflammation or neuronal injury. Median (interquartile range) total and unbound DTG in CSF were 7.3 (5.9-8.4) and 1.7 (1.2-1.9) ng/mL, respectively. DTG+3TC may maintain viral control without changes in inflammatory/injury markers within the CNS reservoir.
Asunto(s)
Fármacos Anti-VIH , Sustitución de Medicamentos , Infecciones por VIH , Fármacos Anti-VIH/uso terapéutico , Biomarcadores/líquido cefalorraquídeo , Infecciones por VIH/tratamiento farmacológico , VIH-1 , Compuestos Heterocíclicos con 3 Anillos/uso terapéutico , Humanos , Lamivudine/uso terapéutico , Oxazinas/uso terapéutico , Piperazinas/uso terapéutico , Piridonas/uso terapéutico , Carga ViralRESUMEN
BACKGROUND: It is important to predict which patients infected by SARS-CoV-2 are at higher risk of life-threatening COVID-19. Several studies suggest that neutralizing auto-antibodies (auto-Abs) against type I interferons (IFNs) are predictive of critical COVID-19 pneumonia. OBJECTIVES: We aimed to test for auto-Abs to type I IFN and describe the main characteristics of COVID-19 patients admitted to intensive care depending on whether or not these auto-Abs are present. METHODS: Retrospective analysis of all COVID-19 patients admitted to an intensive care unit (ICU) in whom samples were available, from March 2020 to March 2021, in Barcelona, Spain. RESULTS: A total of 275 (70.5%) out of 390 patients admitted to ICU were tested for type I IFNs auto-antibodies (α2 and/or ω) by ELISA, being positive in 49 (17.8%) of them. Blocking activity of plasma diluted 1/10 for high concentrations (10 ng/mL) of IFNs was proven in 26 (9.5%) patients. Almost all the patients with neutralizing auto-Abs were men (92.3%). ICU patients with positive results for neutralizing IFNs auto-Abs did not show relevant differences in demographic, comorbidities, clinical features, and mortality, when compared with those with negative results. Nevertheless, some laboratory tests (leukocytosis, neutrophilia, thrombocytosis) related with COVID-19 severity, as well as acute kidney injury (17 [65.4%] vs. 100 [40.2%]; p = 0.013) were significantly higher in patients with auto-Abs. CONCLUSION: Auto-Abs neutralizing high concentrations of type I IFNs were found in 9.5% of patients admitted to the ICU for COVID-19 pneumonia in a hospital in Barcelona. These auto-Abs should be tested early upon diagnosis of SARS-CoV-2 infection, as they account for a significant proportion of life-threatening cases.
Asunto(s)
Anticuerpos Neutralizantes/sangre , Autoanticuerpos/sangre , COVID-19/inmunología , Interferón Tipo I/inmunología , SARS-CoV-2 , Anciano , Femenino , Humanos , Unidades de Cuidados Intensivos , Masculino , Persona de Mediana Edad , Estudios RetrospectivosRESUMEN
Vegetable lipid emulsions (LE) contain non-declared phytosterols (PS). We aimed to determine PS content depending on the brand and LE batch, and in adult hospitalised patients treated with parenteral nutrition (PN), to establish the association between plasma and administered PS. Part I was the LE study: totals and fractions of PS in three to four non-consecutive batches from six LE were analysed. Part II was the patient study: patients with at least 7 previous days of PN with 0·8 g/kg per d of an olive/soyabean (O/S) LE were randomised (day 0) 1:1 to O/S or 100 % fish oil (FO) at a dose of 0·4 g/kg per d for 7 d (day 7). Plasma PS, its fractions, total cholesterol on days 0 and 7, their clearance and their association with PS administered by LE were studied. In part I, LE study: differences were found in the total PS, their fractions and cholesterol among different LE brands and batches. Exclusive soyabean LE had the highest content of PS (422·36 (sd 130·46) µg/ml). In part II, patient study: nineteen patients were included. In the O/S group, PS levels were maintained (1·11 (sd 6·98) µg/ml) from day 0 to 7, while in the FO group, significant decreases were seen in total PS (-6·21 (sd 4·73) µg/ml) and their fractions, except for campesterol and stigmasterol. Plasma PS on day 7 were significantly associated with PS administered (R2 0·443). PS content in different LE brands had great variability. PS administered during PN resulted in accumulation and could be prevented with the exclusive administration of FO LE.
Asunto(s)
Emulsiones Grasas Intravenosas/análisis , Hipercolesterolemia/etiología , Enfermedades Intestinales/etiología , Errores Innatos del Metabolismo Lipídico/etiología , Soluciones para Nutrición Parenteral/química , Nutrición Parenteral/efectos adversos , Fitosteroles/efectos adversos , Fitosteroles/análisis , Adulto , Colesterol/análogos & derivados , Colesterol/análisis , Colesterol/sangre , Femenino , Aceites de Pescado/análisis , Humanos , Pacientes Internos , Masculino , Aceites de Plantas/análisis , Estudios Prospectivos , Estigmasterol/análisis , Verduras/químicaRESUMEN
Background Despite that measurement uncertainty data should facilitate an appropriate interpretation of measured values, there are actually few reported by clinical laboratories. We aimed to estimate the measurement uncertainty of some ß-lactam antibiotics (ß-LA), and to evaluate the impact of reporting the measurement uncertainty on clinicians' decisions while guiding antibiotic therapy. Methods Measurement uncertainty of ß-LA (aztreonam [ATM], cefepime [FEP], ceftazidime [CAZ], and piperacillin [PIP]) values, obtained by an UHPLC-MS/MS based-method, was estimated using the top-down approach called the single laboratory validation approach (EUROLAB guidelines). Main uncertainty sources considered were related to calibrators' assigned values, the intermediate precision, and the bias. As part of an institutional program, patients with osteoarticular infections are treated with ß-LA in continuous infusion and monitored to assure values at least 4 times over the minimal inhibitory concentration (4×MIC). We retrospectively evaluated the impact of two scenarios of laboratory reports on clinicians' expected decisions while monitoring the treatment: reports containing only the ß-LA values, or including the ß-LA coverage intervals (ß-LA values and their expanded measurement uncertainties). Results The relative expanded uncertainties for ATM, FEP, CAZ and PIP were lower than 26.7%, 26.4%, 28.8%, and 25.5%, respectively. Reporting the measurement uncertainty, we identified that clinicians may modify their decision especially in cases where 4×MIC values were within the ß-LA coverage intervals. Conclusions This study provides a simple method to estimate the measurement uncertainty of ß-LA values that can be easily applied in clinical laboratories. Further studies should confirm the potential impact of reporting measurement uncertainty on clinicians' decision-making while guiding antibiotic therapy.
Asunto(s)
Antibacterianos/sangre , Monitoreo de Drogas/métodos , Antibacterianos/farmacología , Antibacterianos/uso terapéutico , Aztreonam/sangre , Enfermedades Óseas Infecciosas/tratamiento farmacológico , Cefepima/sangre , Cromatografía Líquida de Alta Presión , Humanos , Pruebas de Sensibilidad Microbiana , Pseudomonas aeruginosa/efectos de los fármacos , Estudios Retrospectivos , Espectrometría de Masas en Tándem , IncertidumbreRESUMEN
We compared the efficacies of meropenem alone and in combination with colistin against two strains of extended-spectrum-ß-lactamase-producing Klebsiella pneumoniae, using an in vitro pharmacodynamic model that mimicked two different biofilm conditions. Meropenem monotherapy achieved remarkable efficacy (even a bactericidal effect) under all conditions, whereas colistin was almost inactive and resistance emerged. The addition of colistin to meropenem produced no relevant benefits, in contrast to experiences with other microorganisms.
Asunto(s)
Antibacterianos/farmacología , Biopelículas/efectos de los fármacos , Colistina/farmacología , Klebsiella pneumoniae/efectos de los fármacos , Meropenem/farmacología , beta-Lactamasas/metabolismo , Antibacterianos/administración & dosificación , Colistina/administración & dosificación , Farmacorresistencia Bacteriana Múltiple , Quimioterapia Combinada , Klebsiella pneumoniae/enzimología , Klebsiella pneumoniae/ultraestructura , Meropenem/administración & dosificación , Microscopía Electrónica de Rastreo , Resistencia betalactámicaRESUMEN
BACKGROUND: The precise monitoring of everolimus, an immunosuppressant drug, is vital for transplant recipients due to its narrow therapeutic range. This study evaluated the analytical performance of a new electrochemiluminescence immunoassay (ECLIA) for everolimus concentrations in whole blood. METHODS: Accuracy, imprecision, and sensitivity studies for the Roche Elecsys everolimus ECLIA were performed at 5 European laboratories. The ECLIA was compared with liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods, as well as the Quantitative Microsphere System everolimus assay. RESULTS: Everolimus ECLIA accuracies were within the range 100% ± 9%. Coefficients of variation (CVs) across the target range were ≤4.8% for repeatability and ≤8.4% for intermediate imprecision, whereas multisite reproducibility at lower (2.71 mcg/L) and higher everolimus concentrations (3.0-30.0 mcg/L) resulted in CVs of ≤13.7% and ≤12.4%, respectively. The CV at the assay's lower limit of quantification without considering bias was excellent, estimated as ≤9.3% at 0.5 mcg/L. The weighted Deming regression analysis, used for comparison of the results obtained by everolimus ECLIA and by LC-MS/MS methods, yielded a slope of 1.21 [95% confidence interval (CI): 1.15-1.26], intercept of 0.478 mcg/L (95% CI: 0.241-0.716), and a Pearson correlation coefficient (r) of 0.91. A single-site comparison between the ECLIA and the Quantitative Microsphere System assay revealed a slope of 1.05 (95% CI: 0.917-1.17), intercept of 1.03 mcg/L (95% CI: 0.351-1.70), and r of 0.91. CONCLUSIONS: Based on these results, the Roche Elecsys everolimus ECLIA can be considered suitable for routine therapeutic drug monitoring. A positive bias was observed with respect to LC-MS/MS methods, suggesting that it may be necessary to rebaseline individual patients when switching from LC-MS/MS to the ECLIA; however, this must also be considered for any change of method for everolimus measurement.
Asunto(s)
Técnicas Electroquímicas/métodos , Everolimus/sangre , Inmunoensayo/métodos , Luminiscencia , Microesferas , Cromatografía Liquida , Monitoreo de Drogas/métodos , Humanos , Inmunosupresores/sangre , Límite de Detección , Reproducibilidad de los Resultados , Espectrometría de Masas en TándemRESUMEN
Continuous infusion (CI) of beta-lactams could optimize their pharmacokinetic/pharmacodynamic indices, especially in difficult-to-treat infections. PURPOSE: To validate an easy-to-use method to guide beta-lactams dosage in CI (formula). METHODS: A retrospective analysis was conducted of a prospectively collected cohort (n = 24 patients) with osteoarticular infections caused by Gram-negative bacilli (GNB) managed with beta-lactams in CI. Beta-lactams dose was calculated using a described formula (daily dose = 24 h × beta-lactam clearance × target "steady-state" concentration) to achieve concentrations above the MIC. We correlated the predicted concentration (Cpred = daily dose/24 h × beta-lactam clearance) with the patient's observed concentration (Cobs) measured by UPLC-MS/MS (Spearman's coefficient). RESULTS: The most frequent microorganism treated was P. aeruginosa (21 cases; 9 MDR). Beta-lactams in CI were ceftazidime (n = 14), aztreonam (7), and piperacillin/tazobactam (3), mainly used in combination (12 with colistin, 5 with ciprofloxacin) and administered without notable side effects. The plasma Cobs was higher overall than Cpred; the Spearman correlation between both concentrations was rho = 0.6 (IC 95%: 0.2-0.8) for all beta-lactams, and rho = 0.8 (IC 95%: 0.4-1) for those treated with ceftazidime. CONCLUSIONS: The formula may be useful in clinical practice for planning the initial dosage of beta-lactams in CI, while we await a systematic therapeutic drug monitoring. The use of beta-lactams in CI was safe.
Asunto(s)
Antibacterianos/uso terapéutico , Enfermedades Óseas Infecciosas/tratamiento farmacológico , Bacterias Gramnegativas/efectos de los fármacos , Infecciones por Bacterias Gramnegativas/tratamiento farmacológico , beta-Lactamas/uso terapéutico , Anciano , Antibacterianos/administración & dosificación , Antibacterianos/sangre , Antibacterianos/farmacología , Enfermedades Óseas Infecciosas/microbiología , Femenino , Bacterias Gramnegativas/aislamiento & purificación , Infecciones por Bacterias Gramnegativas/microbiología , Humanos , Infusiones Intravenosas , Masculino , Pruebas de Sensibilidad Microbiana , Persona de Mediana Edad , Estudios Retrospectivos , beta-Lactamas/administración & dosificación , beta-Lactamas/sangre , beta-Lactamas/farmacologíaRESUMEN
BACKGROUND: Traceable and accurate results of cyclosporine A (CsA) mass concentrations in whole blood are required to ensure the monitoring of immunosuppressive therapy in transplant recipients. Metrological traceability and measurement uncertainty can allow ensuring reliability and comparability of these results over time and space. In this study, we provide a practical and detailed example of how the traceability and uncertainty of mass concentration of CsA results, obtained using an ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) procedure, can be described and estimated. METHODS: Traceability was described mainly according to ISO 17511 and information obtained from certificates facilitated with the manufacturer's calibrators. Uncertainty estimation was performed using the bottom-up and top-down approaches. For the bottom-up approach, the most relevant sources of uncertainty were identified and later used to estimate the standard, combined and expanded uncertainties. For the top-down approach, expanded uncertainty was estimated directly using intralab quality control data mainly. RESULTS: Mass concentration of CsA results was traceable to the manufacturer's product calibrators used to calibrate the UHPLC-MS/MS procedure. The expanded uncertainties estimated by the bottom-up and top-down approaches were 7.4% and 7.2%, respectively. CONCLUSIONS: After performing the bottom-up and top-down approaches, we observed that their results were quite similar. This fact would confirm that the top-down approach could be sufficient for estimating uncertainty of CsA mass concentrations in whole blood results in clinical laboratories. Finally, we hope that this study can help and motivate clinical laboratories to describe metrological traceability and to perform measurement uncertainty studies based on the simpler top-down approach.
Asunto(s)
Ciclosporina/sangre , Inmunosupresores/sangre , Calibración , Cromatografía Líquida de Alta Presión/normas , Ciclosporina/normas , Humanos , Inmunosupresores/normas , Estándares de Referencia , Espectrometría de Masas en Tándem/normas , IncertidumbreRESUMEN
BACKGROUND: Therapeutic drug monitoring is recommended to guide therapy with the immunosuppressant everolimus (EVL) in solid organ transplantation to prevent rejections and to limit toxicity. For therapeutic drug monitoring, predose EVL concentrations are measured in whole blood mainly by liquid chromatography tandem mass spectrometry (LC-MS/MS). In addition, 2 immunoassays [Quantitative Microsphere System (QMS) EVL and Elecsys EVL] are commercially available. The aim of this study was to evaluate the comparability of EVL results determined with the 2 immunoassays and a validated LC-MS/MS test using samples from kidney, liver, and heart transplant (KT, LT, and HT, respectively) recipients. METHODS: Analysis of predose samples from KT (n = 56), LT (n = 60), and HT (n = 59) recipients, obtained at variable time points after transplantation, was performed by LC-MS/MS and with the 2 immunoassays. The QMS EVL assay was applied on Dimension Xpand Plus and the Elecsys EVL assay on cobas e 411 analyzer. Results were compared by the Spearman's rank correlation coefficient, unbiased Passing and Bablok linear regression test, and Bland-Altman plot. RESULTS: Results generated with both immunoassays correlated well with those of LC-MS/MS. An overestimation of EVL concentrations by the Elecsys EVL compared with LC-MS/MS was observed (mean bias: 34.2%). Using the QMS EVL, a small but significant negative deviation (mean bias: -8.0%) was found. Looking at KT, HT, and LT samples separately, the bias to LC-MS/MS seen with the Elecsys EVL was similar. With the QMS EVL, the best agreement was observed with the KT samples followed by LT and HT. CONCLUSIONS: Results generated by the 3 methods are not consistent regarding their diagnostic value. Both laboratories and manufacturers should take care to inform their costumers about the between-method differences to avoid misinterpretation of the results in clinical practice.
Asunto(s)
Everolimus/sangre , Inmunosupresores/sangre , Cromatografía Liquida/métodos , Monitoreo de Drogas/métodos , Trasplante de Corazón/métodos , Humanos , Inmunoensayo/métodos , Trasplante de Riñón/métodos , Espectrometría de Masas en Tándem/métodosRESUMEN
Ceftazidime is an antibiotic belonging to the third generation of the cephalosporin family. It is indicated in the treatment of serious, simple or mixed bacterial infections, and its administration in continuous or intermittent infusion allows optimization of the concentration of antibiotic to keep it above the minimum inhibitory concentration. We developed and validated a chromatographic method by ultra-performance liquid chromatography-tandem mass spectrometry to measure ceftazidime concentration in human plasma. Following extraction with acetonitrile and 1,2-dichloroethane, the chromatographic separation was achieved using an Acquity ® UPLC ® BEH(TM) (2.1 × 100 mm i.d., 1.7 µm) reverse-phase C18 column, with a water-acetonitrile linear gradient containing 0.1% formic acid at a 0.4 mL/min flow rate. Ceftazidime and its internal standard (cefotaxime) were detected by electrospray ionization mass spectrometry in positive ion multiple reaction monitoring mode using mass-to-charge transitions of 547.0 â 467.9/396.1 and 456.0 â 395.8/324.1, respectively. The limit of quantification was 0.58 mg/L and linearity was observed in the range 0.58-160 mg/L. Coefficients of variation and absolute relative biases were <9.8 and 8.4%. The mean recovery for ceftazidime was 74.4 ± 8.1%. Evaluation of the matrix effect showed ion enhancement, and no carry-over was observed. The validated method could be applied to daily clinical laboratory practice to measure the concentration of ceftazidime in plasma.
Asunto(s)
Enfermedades Óseas Infecciosas/tratamiento farmacológico , Ceftazidima/sangre , Ceftazidima/uso terapéutico , Cromatografía Líquida de Alta Presión/métodos , Espectrometría de Masas en Tándem/métodos , Ceftazidima/química , Monitoreo de Drogas , Estabilidad de Medicamentos , Humanos , Límite de Detección , Modelos Lineales , Pruebas de Sensibilidad Microbiana , Reproducibilidad de los ResultadosRESUMEN
BACKGROUND: Cyclosporine A (CsA) is used as a posttransplantation immunosuppressant drug, and careful monitoring of CsA concentration in whole blood is essential. A new automated electrochemiluminescence immunoassay (ECLIA) for CsA measurement has been assessed in a multicenter evaluation. METHODS: Residual EDTA whole blood samples from patients undergoing CsA therapy after organ transplant were used in assay evaluation at 5 clinical laboratories in Europe. Experiments included imprecision according to CLSI EP5-A2 (within-run and intermediate), lower limit of quantification, linearity according to CLSI EP6-A, and recovery of commercial external quality control samples. In addition, comparisons to liquid chromatography-tandem mass spectrometry methods in routine use at each investigational site and to commercial chemiluminescent microparticle immunoassay and antibody-conjugated magnetic immunoassay methods were performed. RESULTS: Imprecision testing gave coefficients of variation of less than 9% in the 30-2000 mcg/L range for both within-run and intermediate imprecision. Lower limit of quantification of 6.8 mcg/L at one investigational site and 1.8 mcg/L at a second site at 20% coefficient of variation were observed. Linearity was measured over the concentration range 0-2000 mcg/L, yielding a deviation of less than ±12%. External quality control sample recovery by ECLIA was 93%-114% of LC-MS/MS sample recovery. Deming regression analysis of ECLIA method comparison to combined LC-MS/MS results yielded a slope of 1.04 [95% confidence interval (CI), 1.03-1.06] and intercept of 2.8 mcg/L (95% CI, 1.5-4.1 mcg/L). Comparison to chemiluminescent microparticle immunoassay yielded a slope of 0.87 (95% CI, 0.85-0.89) and intercept of 1.4 mcg/L (95% CI, -0.89 to 3.7 mcg/L); comparison to antibody-conjugated magnetic immunoassay yielded a slope of 0.96 (95% CI, 0.93-0.98) and intercept of -4.2 mcg/L (95% CI, -7.1 to -1.2 mcg/L). CONCLUSIONS: The data from this multicenter evaluation indicate that the new ECLIA-based cyclosporine assay is fit for its purpose, the therapeutic monitoring of CsA.
Asunto(s)
Ciclosporina/sangre , Técnicas Electroquímicas/métodos , Inmunoensayo/métodos , Inmunosupresores/sangre , Automatización , Monitoreo de Drogas/métodos , HumanosRESUMEN
Meropenem is a broad-spectrum antibiotic, often used for the empirical treatment of infections in critically ill patients with acute kidney injury. Meropenem has clinically insignificant protein binding and, as a carbapenem antibiotic, shows time-dependent bacterial killing, meaning that the unbound or free antibiotic concentration in blood should be maintained above the minimal inhibitory concentration of the pathogen for at least 40 % of the dosing interval. We developed and validated simple chromatographic methods by ultra-performance liquid chromatography-tandem mass spectrometry to measure plasma, filtrate-dialysate, and urine concentrations of meropenem. Chromatographic separation was achieved using an Acquity(®) UPLC(®) BEH(TM) (2.1 × 100 mm id, 1.7 µm) reverse-phase C(18) column, with a water/acetonitrile linear gradient containing 0.1 % formic acid at a 0.4-mL/min flow rate. Meropenem and its internal standard (ertapenem) were detected by electrospray ionization mass spectrometry in positive ion multiple reaction monitoring mode. The limits of quantification were 0.27, 0.24, and 1.22 mg/L, and linearity was observed between 0.27-150, 0.24-150, and 1.22-2,000 mg/L for plasma, filtrate-dialysate, and urine samples, respectively. Coefficients of variation and relative biases were less than 13.5 and 8.0 % for all biological fluids. Recovery values were greater than 68.3 %. Evaluation of the matrix effect showed ion suppression for meropenem and ertapenem. No carry-over was observed. The validated methods are useful for both therapeutic drug monitoring and pharmacokinetic studies. It could be applied to daily clinical laboratory practice to measure the concentration of meropenem in plasma, filtrate-dialysate, and urine.
Asunto(s)
Antibacterianos/análisis , Líquidos Corporales/química , Cromatografía Liquida/métodos , Monitoreo de Drogas , Espectrometría de Masa por Ionización de Electrospray/métodos , Tienamicinas/análisis , Lesión Renal Aguda/sangre , Lesión Renal Aguda/tratamiento farmacológico , Lesión Renal Aguda/orina , Antibacterianos/farmacología , Enfermedad Crítica/terapia , Humanos , Meropenem , Terapia de Reemplazo Renal , Sepsis/sangre , Sepsis/tratamiento farmacológico , Sepsis/orina , Tienamicinas/farmacologíaRESUMEN
BACKGROUND: Establishing adequate reference intervals (RIs) for vitamins A and E is essential for diagnosing and preventing deficiencies. Due to the current boom in data mining and its easy applicability, more laboratories are establishing RIs using indirect methods. Our study aims to obtain RIs using four indirect data-mining procedures (Bhattacharya, Hoffmann, Kosmic, and RefineR) for vitamins A and E. MATERIAL AND METHODS: 8943 individuals were collected to establish the RIs. After using different data cleaning steps and checking whether these data should be divided according to age and gender based on multiple linear regression and variance component analyses, indirect RIs were calculated using specific Excel spreadsheets or R-packages software. RESULTS: A total of 2004 records were eligible. For vitamin A, the RIs obtained were (1.11 - 2.68) µmol/L, (1.13 - 2.70) µmol/L, (1.13 - 2.71) µmol/L, and (1.17 - 2.66) µmol/L using the Bhattacharya, Hoffmann, Kosmic and RefineR approaches, respectively. For vitamin E, these intervals were (17.3 - 49.9) µmol/L (Bhattacharya), (17.3 - 48.9) µmol/L (Hoffmann), (19.6 - 50.3) µmol/L (Kosmic), and (19.4 - 50.9) µmol/L (RefineR). In all cases, the RIs were comparable. CONCLUSIONS: Suitable RIs for vitamins A and E were calculated using four indirect methods that are suitable and adapted to our population's demographic characteristics.
Asunto(s)
Minería de Datos , Vitamina A , alfa-Tocoferol , Humanos , Vitamina A/sangre , alfa-Tocoferol/sangre , Masculino , Femenino , Adulto , Persona de Mediana Edad , Valores de Referencia , Adulto Joven , Adolescente , Anciano , Niño , Preescolar , Anciano de 80 o más AñosRESUMEN
BACKGROUND: Fixed-dose combinations of antiretroviral drugs are commonly used to treat HIV infection and therapeutic monitoring is not part of routine clinical practice. However, drug concentrations monitoring might have role in different clinical scenarios as well as for research purposes. This study aimed to develop and validate UHPLC-MS/MS procedures for measuring total and unbound concentrations of bictegravir, dolutegravir, darunavir and doravirine in human plasma. MATERIAL AND METHODS: Equilibrium dialysis preceded sample preparation (based on protein precipitation) for measuring unbound antiretroviral concentrations. Chromatographic separations were achieved on an Acquity®-UPLC® HSS™-T3 column (50 mm × 2.1 mm; 1.8 µm) using a non-linear water/acetonitrile gradient containing 0.1 % formic acid at a 0.5 mL/min flow rate. Antiretrovirals were detected by tandem mass spectrometry in positive electrospray ionisation and multiple reaction monitoring modes. RESULTS: No significant interferences or carry-over were observed. Imprecisions, absolute relative biases, normalised matrix effects and recoveries were ≤15.0 %, ≤11.1 %, (94.7-104.1)% and (96.7-105.5)%, respectively. Non-linear measuring intervals were observed between (25-10,000) µg/L for total/plasma dialysate concentrations and linearity schemes (1.00-100) µg/L for buffer dialysate concentrations. CONCLUSIONS: The UHPLC-MS/MS procedures developed could be used for research purposes and therapeutic drug monitoring of antiretrovirals in routine clinical practice.
Asunto(s)
Infecciones por VIH , Espectrometría de Masas en Tándem , Humanos , Espectrometría de Masas en Tándem/métodos , Darunavir , Cromatografía Líquida de Alta Presión/métodos , Infecciones por VIH/tratamiento farmacológico , Diálisis Renal , Soluciones para DiálisisRESUMEN
Objectives: Spontaneous bacterial peritonitis is a frequent severe complication in cirrhotic patients with ascites. Carbapenem antibiotics are currently the treatment of choice for patients with hospital-acquired or healthcare-related infections. However, there is limited evidence available on the efficacy of ertapenem in cirrhotic patients with spontaneous bacterial peritonitis. As a result, the pharmacokynetics and pharmacodynamics of this antibiotic are still unknown. The objective of this study was to develop and validate measurement procedures based on liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) to determine ertapenem concentrations in plasma and ascitic fluid. Methods: Samples were pretreated by acetronile protein-precipitation. Chromatographic separation is performed on a C18 reversed-phase Acquity®-UPLC®-BEHTM column (2.1 × 100 mm id, 1.7⯵m) using a non-linear gradient of water/acetonitrile containing 0.1â¯% of formic acid at a flow rate of 0.4â¯mL/min. Ertapenem and its internal standard (ertapenem-D4) are detected by tandem mass spectrometry using positive electrospray ionization and multiple reaction monitoring, and using 476.2 â 346.0/432.2 as mass transition for ertapenem and 480.2 â 350.0 for its internal standard. Results: No significant interferences or carry-over contamination were observed. Imprecisions, absolute relative bias, matrix effects and normalized recoveries were ≤14.5â¯%, ≤9.3â¯% (92.8-104.5)â¯% and (98.8-105.8)â¯%, respectively. Chromatographic measurement procedures were linear from (0.50-100)â¯mg/L. Conclusions: The measurement procedures based on UHPLC-MS/MS developed and validated in this study could be useful in pharmacokynetic and pharmacodynamic studies in subjects with liver cirrhosis who develop spontaneous bacterial peritonitis treated with ertapenem.