1.
Ophthalmic Physiol Opt ; 41(5): 1125-1133, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34418124

RESUMEN

PURPOSE: Contrast sensitivity (CS) has been proposed as a potential method for patients to assess their vision at home. The CamBlobs2 contrast sensitivity test is meant to be performed easily in the clinic or at home. The purpose of this study was to determine the intra-visit coefficient of repeatability of the CamBlobs2 compared with the near Pelli-Robson test, and the limits of agreement between these two tests on normally-sighted subjects. METHODS: Twenty-two normally-sighted subjects (mean age 28 ± 4 years) completed two trials of the near Pelli-Robson and CamBlobs2 contrast sensitivity tests within a single visit. Tests were performed monocularly on each eye in random order. Pelli-Robson tests were scored as 0.05 logCS for each letter read correctly after deducting the first triplet. CamBlob2 tests were scored as the highest line where two or fewer blobs were marked correctly. The coefficient of repeatability was determined as 1.96 times the standard deviation of the difference between the two measurements using the same type of chart on the same eye. The limits of agreement between the two tests were evaluated using Bland-Altman analysis. RESULTS: The mean difference between intra-visit measurements for both the near Pelli-Robson and CamBlobs2 was less than 0.05 logCS and the coefficient of repeatability was within ±0.20 log CS for both left and right eyes. The mean ± standard deviation differences between near Pelli-Robson and CamBlobs2 scores was -0.08 ± 0.08 (limits of agreement: -0.24 to 0.09) for right eyes and -0.05 ± 0.10 (limits of agreement: -0.23 to 0.14) logCS for left eyes based on average measurements. CONCLUSIONS: The intra-visit repeatability of CamBlobs2 was consistent with the near Pelli-Robson contrast sensitivity test (±0.20 logCS). With a 0.05 correction, the CamBlobs2 scores showed excellent agreement with the near Pelli-Robson contrast sensitivity test.


Asunto(s)
Sensibilidad de Contraste , Pruebas de Visión , Adulto , Ojo , Humanos , Reproducibilidad de los Resultados , Proyectos de Investigación , Adulto Joven
2.
Optom Vis Sci ; 97(9): 732-740, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32976324

RESUMEN

SIGNIFICANCE: To achieve maximum visual benefit, wavefront-guided scleral lens corrections (WGCs) are aligned with the underlying wavefront error of each individual eye. This requirement adds complexity to the fitting process. With a view toward simplification in lens fitting, this study quantified the consequences of placing WGCs at two pre-defined locations. PURPOSE: This study aimed to quantify performance reduction accompanying the placement of the WGC at two locations: (1) the average decentered location (ADL; average decentration observed across individuals wearing scleral lenses) and (2) the geometric center (GC) of the lens. METHODS: Deidentified residual aberration and lens translation data from 36 conventional scleral lens-wearing eyes with corneal ectasia were used to simulate WGC correction in silico. The WGCs were decentered from the eye-specific pupil position to both the ADL and GC locations. The impact of these misalignments was assessed in terms of change (from the aligned, eye-specific pupil position) in higher-order root mean square (HORMS) wavefront error, change in log of the visual Strehl ratio (logVSX), and predicted change in logMAR visual acuity (VA). RESULTS: As expected, HORMS increased, logVSX decreased, and predicted VA was poorer at both ADL and GC compared with the aligned condition (P < .001). Thirty-four of 36 eyes had greater residual HORMS, and 33 of 36 eyes had worse logVSX values at the GC than at the ADL. In clinical terms, 19 of 36 eyes at the ADL and 35 of 36 eyes at the GC had a predicted loss in VA of three letters or greater. CONCLUSIONS: The placement of the WGC at either ADL or GC is predicted to lead to a noticeable reduction in VA for more than half of the eyes studied, suggesting the simplification of the fitting process is not worth the cost in performance.


Asunto(s)
Lentes de Contacto , Aberración de Frente de Onda Corneal/terapia , Queratocono/terapia , Esclerótica , Aberrometría , Adulto , Aberración de Frente de Onda Corneal/fisiopatología , Femenino , Humanos , Queratocono/fisiopatología , Masculino , Ajuste de Prótesis , Pupila/fisiología , Refracción Ocular/fisiología , Agudeza Visual/fisiología
3.
Optom Vis Sci ; 97(9): 754-760, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32941335

RESUMEN

SIGNIFICANCE: An equivalent 12 months of cleaning did not induce significant changes in the optical aberrations or base curves of scleral lenses. PURPOSE: This study aimed to test whether an equivalent of 12 months of manual cleaning alters the optical and physical properties of conventional and wavefront-guided scleral lenses. METHODS: Twelve scleral lenses (four repeats of three designs, termed A, B, and C) were manufactured in Boston XO material: design A, -5.00 D defocus; design B, -5.00 D defocus with -0.153-µm vertical coma; and design C, -5.00 D defocus with a full custom wavefront-guided correction (second to fifth Zernike radial orders) of an eye with severe keratoconus. One lens of each design group served as a control and was not cleaned. To simulate a year of cleaning, seven individuals cleaned nine lenses (three from each group) twice a day for 27 days using the palm technique and commercially available cleaners, resulting in 378 cleanings of each lens. Lens aberrations were optically profiled and base curve radii were measured at baseline and after every 42nd cleaning. Differences in higher-order root mean square (HORMS) wavefront error and base curve radii associated with cleaning were compared with clinical benchmarks and using sign tests. RESULTS: For the experimental lenses, median change in Seidel spherical dioptric power was +0.01 D (maximum, +0.025 D). Median change in HORMS wavefront error was 0.013 µm (maximum, 0.019 µm). All lenses exhibited HORMS changes less than one-eighth equivalent diopters (P = .002). Median percentage change in HORMS wavefront error in the three wavefront-guided lenses was 0.96% (maximum, 1.25%). Median change in base curve radii was 0.00 mm, with all lenses exhibiting changes (P = .002), less than the American National Standards Institute tolerance of 0.05 mm. CONCLUSIONS: Cleaning over an equivalent 12-month period did not induce clinically significant changes in the optical or base curve properties of conventional or wavefront-guided scleral lenses.


Asunto(s)
Soluciones para Lentes de Contacto/uso terapéutico , Lentes de Contacto , Óptica y Fotónica , Esclerótica , Humanos , Queratocono/fisiopatología , Queratocono/terapia , Examen Físico , Agudeza Visual/fisiología
4.
PLoS One ; 17(4): e0266068, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35390023

RESUMEN

PURPOSE: To determine the binocular vision status in normally-sighted school aged children who used digital devices. METHODS: A cross-sectional study was conducted at B.P. Koirala Lions Center for Ophthalmic Studies, Kathmandu, Nepal for a duration of one year. One hundred and eighty school aged children (71 female and 109 male) aged 7 to 17 years were included in the study. All the children underwent detailed ophthalmic and binocular vision examinations. The duration of the use of digital devices by the children were asked to either the parents or guardians present at the time of the study. The study participants were divided into two groups: children who used digital devices for the last six months (users group) and those who hadn't used digital devices for the last six months (non users group). The users group was again divided into two subgroups: children who used digital devices for less than 3 hours per day and a day per week (low digital device users subgroup) and children who used digital devices for more than 3 hours per day and all days in a week (high digital device users subgroup). RESULTS: Accommodative amplitudes, accommodative facility, and positive fusional vergence for both near and distance were significantly reduced in the high digital device users group than in the low digital device users subgroup (p <0.01). Stereo acuity, near point of convergence, and negative fusional vergences for both near and distance were not statistically significantly different between the two subgroups. Prevalence of accommodative and vergence anomalies (except convergence insufficiency) was more in the high digital device users subgroup than in the low digital device users subgroup (p<0.01). CONCLUSIONS: Children who used digital devices for a significantly greater amount of time had significantly reduced amplitudes of accommodation, accommodative facility, and positive fusional vergence both at near and distance.


Asunto(s)
Convergencia Ocular , Tecnología Digital/estadística & datos numéricos , Visión Binocular , Acomodación Ocular , Adolescente , Niño , Estudios Transversales , Femenino , Humanos , Masculino , Padres , Factores de Tiempo
SELECCIÓN DE REFERENCIAS