Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 188
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Europace ; 26(6)2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38702961

RESUMEN

AIMS: Clinical concerns exist about the potential proarrhythmic effects of the sodium channel blockers (SCBs) flecainide and propafenone in patients with cardiovascular disease. Sodium channel blockers were used to deliver early rhythm control (ERC) therapy in EAST-AFNET 4. METHODS AND RESULTS: We analysed the primary safety outcome (death, stroke, or serious adverse events related to rhythm control therapy) and primary efficacy outcome (cardiovascular death, stroke, and hospitalization for worsening of heart failure (HF) or acute coronary syndrome) during SCB intake for patients with ERC (n = 1395) in EAST-AFNET 4. The protocol discouraged flecainide and propafenone in patients with reduced left ventricular ejection fraction and suggested stopping therapy upon QRS prolongation >25% on therapy. Flecainide or propafenone was given to 689 patients [age 69 (8) years; CHA2DS2-VASc 3.2 (1); 177 with HF; 41 with prior myocardial infarction, coronary artery bypass graft, or percutaneous coronary intervention; 26 with left ventricular hypertrophy >15 mm; median therapy duration 1153 [237, 1828] days]. The primary efficacy outcome occurred less often in patients treated with SCB [3/100 (99/3316) patient-years] than in patients who never received SCB [SCBnever 4.9/100 (150/3083) patient-years, P < 0.001]. There were numerically fewer primary safety outcomes in patients receiving SCB [2.9/100 (96/3359) patient-years] than in SCBnever patients [4.2/100 (135/3220) patient-years, adjusted P = 0.015]. Sinus rhythm at 2 years was similar between groups [SCB 537/610 (88); SCBnever 472/579 (82)]. CONCLUSION: Long-term therapy with flecainide or propafenone appeared to be safe in the EAST-AFNET 4 trial to deliver effective ERC therapy, including in selected patients with stable cardiovascular disease such as coronary artery disease and stable HF. Clinical Trial Registration ISRCTN04708680, NCT01288352, EudraCT2010-021258-20, www.easttrial.org.


Asunto(s)
Antiarrítmicos , Flecainida , Bloqueadores de los Canales de Sodio , Humanos , Anciano , Masculino , Femenino , Resultado del Tratamiento , Persona de Mediana Edad , Flecainida/uso terapéutico , Flecainida/efectos adversos , Antiarrítmicos/uso terapéutico , Antiarrítmicos/efectos adversos , Bloqueadores de los Canales de Sodio/uso terapéutico , Bloqueadores de los Canales de Sodio/efectos adversos , Fibrilación Atrial/tratamiento farmacológico , Insuficiencia Cardíaca/tratamiento farmacológico , Insuficiencia Cardíaca/fisiopatología , Factores de Tiempo , Frecuencia Cardíaca/efectos de los fármacos , Accidente Cerebrovascular
2.
Circ J ; 2024 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-38839350

RESUMEN

BACKGROUND: Achieving early rhythm control and maintaining sinus rhythm are associated with improved outcomes in patients with atrial fibrillation (AF). Pulmonary vein isolation (PVI) is a validated alternative to medical rhythm control. This study determined associations between left atrial strain reservoir (LASR) and AF recurrence after PVI.Methods and Results: In all, 132 patients (88 with paroxysmal AF [PAF], 44 with persisting AF [PersAF]) who presented in sinus rhythm for de novo PVI of AF between December 2017 and January 2019 were included in the study. All patients underwent preprocedural echocardiography. After 12 months, all patients underwent 24-h Holter electrocardiogram monitoring to screen for AF recurrence. Kaplan-Meier curve analysis revealed an association between decreasing LASRand increased AF recurrence, with a cut-off at 31.4%. In univariable Cox regression analysis, LASRdemonstrated an association with AF recurrence, with hazard ratios (HR) of 0.83 (95% confidence interval [CI] 073-0.93; P=0.001) per 5% increase in univariable models and 0.83 (95% CI 073-0.95; P=0.005) in multivariable analysis. When clinical variables with age, sex and type of AF (PAF/PersAF) were included in the multivariable analysis, LASRremained relevant in a model with age (HR 0.86; 95% CI 073-1.00; P=0.046). CONCLUSIONS: In patients undergoing de novo PVI for AF, LASRcould be of use in risk stratification regarding AF recurrence.

3.
Circulation ; 146(11): 836-847, 2022 09 13.
Artículo en Inglés | MEDLINE | ID: mdl-35968706

RESUMEN

BACKGROUND: The randomized EAST-AFNET4 (Early Treatment of Atrial Fibrillation for Stroke Prevention Trial-Atrial Fibrillation Network) demonstrated that early rhythm control (ERC) reduces adverse cardiovascular outcomes in patients with recently diagnosed atrial fibrillation and stroke risk factors. The effectiveness and safety of ERC in patients with multiple cardiovascular comorbidities is not known. METHODS: These prespecified subanalyses of EAST-AFNET4 compared the effectiveness and safety of ERC with usual care (UC) stratified into patients with higher (CHA2DS2-VASc score ≥4) and lower comorbidity burden. Sensitivity analyses ignored sex (CHA2DS2-VA score). RESULTS: EAST-AFNET4 randomized 1093 patients with CHA2DS2-VASc score ≥4 (74.8±6.8 years, 61% female) and 1696 with CHA2DS2-VASc score <4 (67.4±8.0 years, 37% female). ERC reduced the composite primary efficacy outcome of cardiovascular death, stroke, or hospitalization for worsening of heart failure or for acute coronary syndrome in patients with CHA2DS2-VASc score ≥4 (ERC, 127/549 patients with events; UC, 183/544 patients with events; hazard ratio [HR], 0.64 [0.51-0.81]; P < 0.001) but not in patients with CHA2DS2-VASc score <4 (ERC, 122/846 patients with events; UC, 133/850 patients with events; HR, 0.93 [0.73-1.19]; P=0.56, Pinteraction=0.037). The primary safety outcome (death, stroke, or serious adverse events of rhythm control therapy) was not different between study groups in patients with CHA2DS2-VASc score ≥4 (ERC, 112/549 patients with events; UC, 132/544 patients with events; HR, 0.84 [0.65, 1.08]; P=0.175), but occurred more often in patients with CHA2DS2-VASc scores <4 randomized to ERC (ERC, 119/846 patients with events; UC, 91/850 patients with events; HR, 1.39 [1.05-1.82]; P=0.019, Pinteraction=0.008). Life-threatening events or death were not different between groups (CHA2DS2-VASc score ≥4, ERC, 84/549 patients with event, UC, 96/544 patients with event; CHA2DS2-VASc scores <4, ERC, 75/846 patients with event, UC, 73/850 patients with event). When female sex was ignored for the creation of higher and lower risk groups (CHA2DS2-VA score), the Pinteraction was not significant for the primary efficacy outcome (P=0.25), but remained significant (P=0.044) for the primary safety outcome. CONCLUSIONS: Patients with recently diagnosed atrial fibrillation and CHA2DS2-VASc score ≥4 should be considered for ERC to reduce cardiovascular outcomes, whereas those with fewer comorbidities may have less favorable outcomes with ERC. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT01288352. URL: https://www.clinicaltrialsregister.eu; Unique identifier: 2010-021258-20. URL: https://www.isrctn.com/; Unique identifier: ISRCTN04708680.


Asunto(s)
Fibrilación Atrial , Accidente Cerebrovascular , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Comorbilidad , Femenino , Humanos , Masculino , Medición de Riesgo , Factores de Riesgo , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control
4.
J Cardiovasc Electrophysiol ; 34(9): 1802-1807, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37473404

RESUMEN

INTRODUCTION: Pulsed-field ablation (PFA) and the multielectrode radiofrequency balloon (RFB) are two novel ablation technologies to perform pulmonary vein isolation (PVI). It is currently unknown whether these technologies differ in lesion formation and lesion extent. We compared the acute lesion extent after PVI induced by PFA and RFB by measuring low-voltage area in high-density maps and the release of biomolecules reflecting cardiac injury. METHODS: PVI was performed with a pentaspline catheter (FARAPULSE) applying PFA or with the compliant multielectrode RFB (HELIOSTAR). Before and after PVI high-density mapping with CARTO 3 was performed. In addition, blood samples were taken before transseptal puncture and after post-PVI remapping and serum concentrations of high-sensitive Troponin I were quantified by immunoassay. RESULTS: Sixty patients undergoing PVI by PFA (n = 28, age 69 ± 12 year, 60% males, 39.3% persistent atrial fibrillation [AF]) or RFB (n = 32, age 65 ± 13 year, 53% males, 21.9% persistent AF) were evaluated. Acute PVI was achieved in all patients in both groups. Mean number of PFA pulses was 34.2 ± 4.5 and mean number RFB applications was 8.5 ± 3 per patient. Total posterior ablation area was significantly larger in PFA (20.7 ± 7.7 cm²) than in RFB (7.1 ± 2.09 cm²; p < .001). Accordingly, posterior ablation area for each PV resulted in larger lesions after PFA versus RFB (LSPV 5.2 ± 2.7 vs. 1.9 ± 0.8 cm², LIPV 5.5 ± 2.3 vs. 1.9 ± 0.8 cm², RSPV 4.7 ± 1.9 vs. 1.6 ± 0.5 cm², RIPV 5.3 ± 2.1 vs. 1.6 ± 0.7 cm,² respectively; p < .001). In a subset of 38 patients, increase of hsTropI was higher after PFA (625 ± 138 pg/mL, n = 28) versus RFB (148 ± 36 pg/mL, n = 10; p = .049) supporting the evidence of larger lesion extent by PFA. CONCLUSION: PFA delivers larger acute lesion areas and higher troponin release upon successful PVI than multielectrode RFB-based PVI in this single-center series.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Masculino , Humanos , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Femenino , Venas Pulmonares/cirugía , Resultado del Tratamiento , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Catéteres
5.
Europace ; 25(5)2023 05 19.
Artículo en Inglés | MEDLINE | ID: mdl-37116126

RESUMEN

AIMS: A novel irrigated radiofrequency (RF) balloon (RFB) for pulmonary vein (PV) isolation (PVI) was released in selected centres. We pooled the procedural data on efficacy and safety of RFB-PVI from two high volume German centres. METHODS AND RESULTS: Consecutive patients with RFB procedures were enrolled. A 3D electroanatomical left atrial map guided the RFB navigation. Every RF delivery lasted 60 s, and duration was automatically reduced to 20 s for electrodes facing the posterior wall. Procedural data and post-procedural endoscopy data (<48 h) were analysed. Data from 140 patients were collected (57% male, 67 ± 11 years, 57% paroxysmal atrial fibrillation). There were 547 PVs identified, and 99.1% could be isolated using solely the RFB. Single-shot PVI was recorded in 330/547 (60%) PVs. Median time to isolation during the first application was 10 s (IQR 8-13). A total of 2.1 ± 1.8 applications per PV were delivered, with the left superior PV requiring more application compared to other PVs. Median procedure and fluoroscopy time were 77 min (61-99) and 13 min (10-17), respectively. Major safety events were recorded only in the first 25 cases at each centre and included 1/140(0.7%) cardiac tamponade, 1/140(0.7%) phrenic nerve palsy, and 2/140 strokes (1.4%). An oesophageal temperature rise was recorded in 81/547 (15%) PVs, and endoscopy detected oesophageal lesions in 7/85 (8%) patients undergoing endoscopy. CONCLUSION: The RFB showed a high efficacy allowing for fast PVI procedures, and 60% of PVs could be isolated at the first application. Most safety events were recorded during the learning phase. An oesophageal temperature monitoring is suggested: oesophageal lesions were detected in 8% of patients.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Masculino , Femenino , Resultado del Tratamiento , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/etiología , Atrios Cardíacos , Venas Pulmonares/cirugía
6.
Europace ; 25(5)2023 05 19.
Artículo en Inglés | MEDLINE | ID: mdl-36966734

RESUMEN

AIMS: The randomized, controlled EAST-AFNET 4 trial showed that early rhythm control (ERC) reduces the rate of a composite primary outcome (cardiovascular death, stroke, or hospitalization for worsening heart failure or acute coronary syndrome) by ∼20%. The current study examined the cost-effectiveness of ERC compared to usual care. METHODS AND RESULTS: This within-trial cost-effectiveness analysis was based on data from the German subsample of the EAST-AFNET 4 trial (n = 1664/2789 patients). Over a 6-year time horizon and from a healthcare payer's perspective, ERC was compared to usual care regarding costs (hospitalization and medication) and effects (time to primary outcome; years survived). Incremental cost-effectiveness ratios (ICERs) were calculated. Cost-effectiveness acceptability curves were constructed to visualize uncertainty. Early rhythm control was associated with higher costs [+€1924, 95% CI (-€399, €4246)], resulting in ICERs of €10 638 per additional year without a primary outcome and €22 536 per life year gained. The probability of ERC being cost-effective compared to usual care was ≥95% or ≥80% at a willingness-to-pay value of ≥€55 000 per additional year without a primary outcome or life year gained, respectively. CONCLUSION: From a German healthcare payer's perspective, health benefits of ERC may come at reasonable costs as indicated by the ICER point estimates. Taking statistical uncertainty into account, cost-effectiveness of ERC is highly probable at a willingness-to-pay value of ≥€55 000 per additional life year or year without a primary outcome. Future studies examining the cost-effectiveness of ERC in other countries, subgroups with higher benefit from rhythm control therapy, or cost-effectiveness of different modes of ERC are warranted.


Asunto(s)
Fibrilación Atrial , Insuficiencia Cardíaca , Accidente Cerebrovascular , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Fibrilación Atrial/complicaciones , Análisis Costo-Beneficio , Análisis de Costo-Efectividad , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/complicaciones , Accidente Cerebrovascular/complicaciones , Años de Vida Ajustados por Calidad de Vida
7.
Circ J ; 87(7): 950-956, 2023 06 23.
Artículo en Inglés | MEDLINE | ID: mdl-37286488

RESUMEN

BACKGROUND: A novel multielectrode radiofrequency balloon (RFB) catheter has been released for pulmonary vein isolation (PVI).Methods and Results: In this observational study consecutive patients with drug-refractory paroxysmal or persistent atrial fibrillation (AF) undergoing first-time PVI were enrolled in 2 high-volume ablation centers. All procedures were conducted in conjunction with a 3D-mapping system. Clinical, procedural and ablation parameters were systematically analyzed. 105 patients (58% male; 52% paroxysmal AF, 68±11.3 years mean age, left atrial volume index 38.6±14.8 mL/m2) were included. 241/412 (58.5%) PVs were successfully isolated with a single shot (SS), with a time-to-isolation of 11.6±8 s. Total number of radiofrequency applications was 892 (mean 2.2/PV), resulting in successful isolation of 408/412 (99%) PVs at the end of the procedure. Mean electrodes' impedance drop was significantly higher in the SS-PVI compared with non-SS applications (21.5±6.6 vs. 18.6±6.5 Ohm). Concordantly, higher temperature rise was observed in the SS vs. non-SS applications (10.9±4.9℃ vs. 9.6±4.7℃). CONCLUSIONS: In this multicenter real-world study, mean impedance drop and temperature rise were associated with successful SS-PVI applying the novel RFB catheter. These parameters may help to guide efficient usage of the new RF balloon.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Masculino , Femenino , Resultado del Tratamiento , Ablación por Catéter/métodos , Fibrilación Atrial/cirugía , Atrios Cardíacos , Venas Pulmonares/cirugía , Catéteres , Recurrencia
8.
Pacing Clin Electrophysiol ; 46(1): 11-19, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36356298

RESUMEN

BACKGROUND: Catheter ablation has been evolved to a cornerstone in the therapy of atrial fibrillation (AF); however, atrial tachycardias (AT) after AF ablation are still an important issue. Besides the electrical recurrence of atrial tachyarrhythmia after ablation, left atrial (LA) remodeling has received attention as a consequence of AF. OBJECTIVE: The aim of this study is to evaluate predictors for AT recurrence and LA remodeling in patients with repeat AF ablation procedures. METHODS AND RESULTS: One hundred thirteen patients who underwent repeat AF ablation with 3D electro-anatomical mapping system were evaluated. Mean age was 63.1 ± 9.3 years, and 2.3 ± 0.5 ablation procedures were performed during a time period of 22 [IQR 7;48] months. Reverse structural LA remodeling (LA volume decreased more than 15%) was observed in 25 (22.1%) patients. LA volume index (LAVI) during first procedure was the only predictor for positive reverse structural LA remodeling (hazard ratio (HR): 1.03, 95% CI: 1.00-1.07, p = .036) in multivariate analysis. Fifty-nine (52.2%) patients experienced only AF and 54 (47.8%) patients AT after first procedure. Female gender (HR: 5.21, 95% CI: 1.66-18.08, p = .006), LAVI (HR: 1.06, 95% CI: 1.02-1.11, p = .008) and LA scar percentage (HR: 1.08, 95% CI: 1.02-1.17, p = .019) were independent significant predictors for AT recurrence in multivariate analysis. CONCLUSIONS: Reverse structural LA remodeling occurred in a quarter of patients with repeat ablation procedures for AF. Only larger LAVI during first procedure predicted reverse structural LA remodeling. Half of the patients experienced AT between first and last ablation procedure. Female gender, larger LAVI and larger scar area were significant predictors for AT after catheter ablation for AF.


Asunto(s)
Fibrilación Atrial , Remodelación Atrial , Ablación por Catéter , Taquicardia Supraventricular , Humanos , Femenino , Persona de Mediana Edad , Anciano , Cicatriz , Atrios Cardíacos/cirugía , Ablación por Catéter/métodos , Resultado del Tratamiento , Recurrencia
9.
Pacing Clin Electrophysiol ; 46(2): 161-168, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36588339

RESUMEN

BACKGROUND: Catheter ablation is an effective treatment for atrial fibrillation (AF,) but arrhythmia recurrence occurs in a relevant number of patients. Mechanisms of late occurring arrhythmias after ablation procedures are not fully understood. We analyzed electrophysiological mechanisms of early and late arrhythmia recurrences in patients who underwent radiofrequency-based catheter ablation of AF. METHODS AND RESULTS: Consecutive patients who underwent repeat ablation procedures after initial pulmonary vein isolation (PVI) for symptomatic arrhythmia recurrence were analyzed. A total of 110 consecutive patients who underwent catheter ablation for paroxysmal (79%) or persistent AF (21%) were included. Forty-seven patients suffered from early arrhythmia recurrence (group #1: 3-24 months), 29 patients from mid-term arrhythmia recurrences (group #2: 2-5 years), and 34 patients from late arrhythmia recurrences (group #3: > 5 years). Electrical PV reconnection was found in 98% in group #1, 72% in group #2 and 56% in group #3 (p < .001). Mode of arrhythmia recurrence was organized tachycardia in 25%, 28%, and 65% of patients in groups #1, #2, and #3 (p = .001), respectively. Patients with late arrhythmia recurrence had more pronounced left atrial low voltage as compared to patients with early arrhythmia recurrence based on two published scoring system. CONCLUSION: Electrical PV reconnection was found in the majority of patients with early AF recurrence after PVI. In patients with late arrhythmia recurrences this mechanism may play an inferior role, with many patients presenting without PV reconnection, but with LA structural alterations. Thus, early and late occurring arrhythmia recurrence after catheter ablation may be the same symptom of different diseases.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Venas Pulmonares/cirugía , Recurrencia , Atrios Cardíacos , Resultado del Tratamiento , Ablación por Catéter/métodos
10.
Circulation ; 144(11): 845-858, 2021 09 14.
Artículo en Inglés | MEDLINE | ID: mdl-34328366

RESUMEN

BACKGROUND: Even on optimal therapy, many patients with heart failure and atrial fibrillation experience cardiovascular complications. Additional treatments are needed to reduce these events, especially in patients with heart failure and preserved left ventricular ejection fraction. METHODS: This prespecified subanalysis of the randomized EAST-AFNET4 trial (Early Treatment of Atrial Fibrillation for Stroke Prevention Trial) assessed the effect of systematic, early rhythm control therapy (ERC; using antiarrhythmic drugs or catheter ablation) compared with usual care (allowing rhythm control therapy to improve symptoms) on the 2 primary outcomes of the trial and on selected secondary outcomes in patients with heart failure, defined as heart failure symptoms New York Heart Association II to III or left ventricular ejection fraction [LVEF] <50%. RESULTS: This analysis included 798 patients (300 [37.6%] female, median age 71.0 [64.0, 76.0] years, 785 with known LVEF). The majority of patients (n=442) had heart failure and preserved LVEF (LVEF≥50%; mean LVEF 61±6.3%), the others had heart failure with midrange ejection fraction (n=211; LVEF 40%-49%; mean LVEF 44 ± 2.9%) or heart failure with reduced ejection fraction (n=132; LVEF<40%; mean LVEF 31±5.5%). Over the 5.1-year median follow-up, the composite primary outcome of cardiovascular death, stroke, or hospitalization for worsening of heart failure or for acute coronary syndrome occurred less often in patients randomly assigned to ERC (94/396; 5.7 per 100 patient-years) compared with patients randomly assigned to usual care (130/402; 7.9 per 100 patient-years; hazard ratio, 0.74 [0.56-0.97]; P=0.03), not altered by heart failure status (interaction P value=0.63). The primary safety outcome (death, stroke, or serious adverse events related to rhythm control therapy) occurred in 71 of 396 (17.9%) patients with heart failure randomly assigned to ERC and in 87 of 402 (21.6%) patients with heart failure randomly assigned to usual care (hazard ratio, 0.85 [0.62-1.17]; P=0.33). LVEF improved in both groups (LVEF change at 2 years: ERC 5.3±11.6%, usual care 4.9±11.6%, P=0.43). ERC also improved the composite outcome of death or hospitalization for worsening of heart failure. CONCLUSIONS: Rhythm control therapy conveys clinical benefit when initiated within 1 year of diagnosing atrial fibrillation in patients with signs or symptoms of heart failure. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT01288352. URL: http://www.controlled-trials.com; Unique identifier: ISRCTN04708680. URL: https://www.clinicaltrialsregister.eu; Unique identifier: 2010-021258-20.


Asunto(s)
Fibrilación Atrial/terapia , Insuficiencia Cardíaca/terapia , Prevención Secundaria , Disfunción Ventricular Izquierda/terapia , Adulto , Anciano , Anciano de 80 o más Años , Antiarrítmicos/uso terapéutico , Fibrilación Atrial/fisiopatología , Femenino , Humanos , Masculino , Accidente Cerebrovascular/terapia , Volumen Sistólico/fisiología , Disfunción Ventricular Izquierda/fisiopatología , Función Ventricular Izquierda/fisiología
11.
J Cardiovasc Electrophysiol ; 33(4): 654-663, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35118743

RESUMEN

INTRODUCTION: The prevalence of obesity is increasing. However, data on the periprocedural complication rate of catheter ablation for arrhythmia in patients stratified by body mass index (BMI) are scarce. METHODS: This study included 1000 consecutive patients (age 62.0 ± 14.4 years) undergoing catheter ablation for cardiac arrhythmia. The primary study endpoint was any periprocedural major complication (cardiac tamponade, pseudoaneurysm, arteriovenous fistula, transient ischemic attack, stroke, valve damage, myocardial infarction, or death). RESULTS: The mean BMI was 27.6 ± 5.1 kg/m2 and the majority of patients were overweight (BMI 25.0-29.9 kg/m2 , 43.4%). A BMI of 30.0-34.9 kg/m2 (Class I obesity) was present in 177 (17.7%) of patients, a BMI of 35.0-39.9 kg/m2 (Class II obesity) in 67 (6.7%), and a BMI ≥ 40 kg/m2 (Class III obesity) in 16 (1.6%). There were 31 major complications (3.1%) and one fatality (0.1%) due to terminal heart failure in a patient undergoing palliative ventricular tachycardia ablation. There was no significant impact of the BMI on the rate of major complications (p = .495). Compared to normal weight patients, odds ratios for complications in overweight patients, as well as Class I, II, and III obesity were 1.1 (95% confidence interval (CI): 0.8, 1.7), 1.3 (CI: 0.6, 2.6), 1.4 (CI: 0.5, 4.1), and 1.6 (CI: 0.4, 6.3), respectively. Radiation exposure and procedure duration were significantly increased in obese patients (p < .001 and p = .001, respectively). CONCLUSION: In this study, obesity did not have a significant impact on the incidence of periprocedural complications after CA for cardiac arrhythmia.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Anciano , Índice de Masa Corporal , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Humanos , Persona de Mediana Edad , Obesidad/complicaciones , Obesidad/diagnóstico , Obesidad/epidemiología , Sobrepeso/complicaciones , Factores de Riesgo
12.
J Cardiovasc Electrophysiol ; 33(6): 1096-1103, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35304790

RESUMEN

BACKGROUND: Cryoballoon (CB)-based pulmonary vein isolation (PVI) has proven to be as effective as radiofrequency-based ablation. Different ablation protocols took the individual time-to-isolation (TTI) into account aiming at shorter but equally or even more effective freeze cycles. The current study sought to assess the impact of the TTI on PVI durability in patients undergoing a repeat procedure for recurrence of atrial tachyarrhythmia (ATA). METHODS AND RESULTS: In 205 patients with ATA recurrence after previous CB-based PVI, a total of 806 pulmonary veins (PVs) were identified. A total of 126 out of 806 PVs (16%) were previously treated with a TTI-guided ablation (Protocol #1; TTI + 120 s), in 92/806 (11%) PVs TTI was only monitored (m) but fixed freeze cycles were applied (Protocol #2; mTTI) and in 588/806 (73%) a fixed freeze cycle was applied without mTTI. There was no difference in the PV-reconduction rate between the groups (p = .23). The right inferior pulmonary vein (RIPV) showed overall significantly higher reconduction rates compared to the other PVs (RIPV-left inferior PV p < .003, -left superior PV p < .001, -right superior PV p < .013). Twenty-one patients (10%) were demonstrated to have only electrical reconduction of the RIPV, while all other PVs were still electrically isolated. CONCLUSIONS: The TTI-based CB ablation protocol did not show significant differences regarding PV-reconduction rates compared to the other ablation protocols.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Criocirugía/efectos adversos , Criocirugía/métodos , Humanos , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento
13.
J Cardiovasc Electrophysiol ; 33(1): 48-54, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34766404

RESUMEN

INTRODUCTION: Cryoballoon (CB) ablation for pulmonary vein isolation (PVI) is an effective treatment of atrial fibrillation (AF). Recently, a novel cryoablation system was introduced. The aim of the study was to compare the safety, efficacy and biophysical characteristics of a novel cryoablation system (POLARx™; Boston Scientific) to a commonly used and clinically well characterized system (Arctic Front Advance Pro™, AFA; Medtronic). METHODS AND RESULTS: Fifty consecutive patients with symptomatic AF, who underwent CB-based ablation with the POLARx were compared to 50 consecutive patients treated with the AFA. Acute PVI was achieved in 99.8% (POLARx 99.5%, AFA 100%, p = 1.00). Time to isolation (TTI) was comparable in both groups (POLARx 35 [27, 48] s, AFA 30 [21, 43] s, p = 0.165). The POLARx showed a lower balloon temperature at TTI (POLARx -44 [-50, -36] °C, AFA -31 [-38, -21] °C, p < 0.001) and lower nadir temperature (POLARx -60 [-65, -55] °C, AFA -48 [-54, -45] °C, p < 0.001). Procedure time (POLARx 80 [60, 105] min, AFA 62 [42, 80] min, p < 0.001), fluoroscopy time (POLARx 17 [13, 22] min, AFA 11 [7, 16] min, p < 0.001) and freeze cycles per patient (POLARx 5 [4, 6], AFA 4.5 [4, 5], p = 0.002) were higher in the POLARx group. Two cerebral ischemic events occurred in the POLARx group, two patients in each group had phrenic nerve injury. CONCLUSION: Both systems enable effective isolation of pulmonary veins. The POLARx required longer procedure and fluoroscopy times. Larger, prospective and randomized studies are needed to assess long-term efficacy and safety of this technology.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Criocirugía/efectos adversos , Criocirugía/métodos , Humanos , Estudios Prospectivos , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Tecnología , Resultado del Tratamiento
14.
Europace ; 24(6): 959-969, 2022 07 15.
Artículo en Inglés | MEDLINE | ID: mdl-34922350

RESUMEN

AIMS: Bipolar radiofrequency ablation (B-RFA) has been reported as a bail-out strategy for the treatment of therapy refractory ventricular arrhythmias (VA). Currently, existing setups have not been standardized for B-RFA, while the impact of conventional B-RFA approaches on lesion formation remains unclear. METHODS AND RESULTS: (i) In a multicentre observational study, patients undergoing B-RFA for previously therapy-refractory VA using a dedicated B-RFA setup were retrospectively analysed. (ii) Additionally, in an ex vivo model lesion formation during B-RFA was evaluated using porcine hearts. In a total of 26 procedures (24 patients), acute success was achieved in all 14 ventricular tachycardia (VT) procedures and 7/12 procedures with premature ventricular contractions (PVC), with major complications occurring in 1 procedure (atrioventricular block). During a median follow-up of 211 days in 21 patients, 6/11 patients (VT) and 5/10 patients (PVC) remained arrhythmia-free. Lesion formation in the ex vivo model during energy titration from 30 to 50 W led to similar lesion volumes compared with initial high-power 50 W B-RFA. Lesion size significantly increased when combining sequential unipolar and B-RFA (1429 mm3 vs. titration 501 mm3 vs. B-RFA 50 W 423 mm3, P < 0.001), an approach used in overall 58% of procedures and more frequently applied in procedures without VA recurrence (92% vs. 36%, P = 0.009). Adipose tissue severely limited lesion formation during B-RFA. CONCLUSION: Using a dedicated device for B-RFA for therapy-refractory VA appears feasible and safe. While some patients need repeat ablation, success rates were encouraging. Sequential unipolar and B-RFA may be favourable for lesion formation.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Complejos Prematuros Ventriculares , Animales , Ablación por Catéter/métodos , Estudios Retrospectivos , Porcinos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía , Resultado del Tratamiento , Complejos Prematuros Ventriculares/diagnóstico , Complejos Prematuros Ventriculares/cirugía
15.
Europace ; 24(12): 1917-1925, 2022 Dec 09.
Artículo en Inglés | MEDLINE | ID: mdl-36026521

RESUMEN

AIMS: Pulmonary vein isolation (PVI) either by balloon devices or radiofrequency forms the cornerstone of invasive atrial fibrillation (AF) treatment. Although equally effective cryoballoon (CB)-based PVI offers shorter procedure duration and a better safety profile. Beside the worldwide established Arctic Front Advance system, a novel CB device, POLARx, was recently introduced. This CB incorporates unique features, which may translate into improved efficacy and safety. However, multicentre assessment of periprocedural efficacy and safety is lacking up to date. METHODS AND RESULTS: A total of 317 patients with paroxysmal or persistent AF were included and underwent POLARx CB-based PVI in 6 centres from Germany and Italy. Acute efficacy and safety were assessed in this prospective multicenter observational study. In 317 patients [mean age: 64 ± 12 years, 209 of 317 (66%) paroxysmal AF], a total of 1256 pulmonary veins (PVs) were identified and 1252 (99,7%) PVs were successfully isolated utilizing mainly the short tip POLARx CB (82%). The mean minimal CB temperature was -57.9 ± 7°C. Real-time PVI was registered in 72% of PVs. The rate of serious adverse events was 6.0% which was significantly reduced after a learning curve of 25 cases (9.3% vs. 3.0%, P = 0.018). The rate of recurrence-free survival after mean follow-up of 226 ± 115 days including a 90-day blanking period was 86.1%. CONCLUSION: In this large multicentre assessment, the novel POLARx CB shows a promising efficacy and safety profile after a short learning curve.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Persona de Mediana Edad , Anciano , Venas Pulmonares/cirugía , Ablación por Catéter/métodos , Estudios Prospectivos , Resultado del Tratamiento , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/etiología
16.
Europace ; 24(8): 1256-1266, 2022 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-35647644

RESUMEN

AIMS: Pulsed field ablation (PFA) is a novel atrial fibrillation (AF) ablation modality that has demonstrated preferential tissue ablation, including no oesophageal damage, in first-in-human clinical trials. In the MANIFEST-PF survey, we investigated the 'real world' performance of the only approved PFA catheter, including acute effectiveness and safety-in particular, rare oesophageal effects and other unforeseen PFA-related complications. METHODS AND RESULTS: This retrospective survey included all 24 clinical centres using the pentaspline PFA catheter after regulatory approval. Institution-level data were obtained on patient characteristics, procedure parameters, acute efficacy, and adverse events. With an average of 73 patients treated per centre (range 7-291), full cohort included 1758 patients: mean age 61.6 years (range 19-92), female 34%, first-time ablation 94%, paroxysmal/persistent AF 58/35%. Most procedures employed deep sedation without intubation (82.1%), and 15.1% were discharged same day. Pulmonary vein isolation (PVI) was successful in 99.9% (range 98.9-100%). Procedure time was 65 min (38-215). There were no oesophageal complications or phrenic nerve injuries persisting past hospital discharge. Major complications (1.6%) were pericardial tamponade (0.97%) and stroke (0.4%); one stroke resulted in death (0.06%). Minor complications (3.9%) were primarily vascular (3.3%), but also included transient phrenic nerve paresis (0.46%), and TIA (0.11%). Rare complications included coronary artery spasm, haemoptysis, and dry cough persistent for 6 weeks (0.06% each). CONCLUSION: In a large cohort of unselected patients, PFA was efficacious for PVI, and expressed a safety profile consistent with preferential tissue ablation. However, the frequency of 'generic' catheter complications (tamponade, stroke) underscores the need for improvement.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Accidente Cerebrovascular , Adulto , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/etiología , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Femenino , Humanos , Persona de Mediana Edad , Venas Pulmonares/cirugía , Estudios Retrospectivos , Accidente Cerebrovascular/etiología , Resultado del Tratamiento , Adulto Joven
17.
Int Heart J ; 63(3): 504-509, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35650152

RESUMEN

Pulmonary vein (PV) isolation (PVI) by continuous, transmural and durable lesions is decisive for ensuring long-term freedom from atrial fibrillation (AF). AF ablation requires irrigated tip catheters to reduce thromboembolic complications. This precluded temperature-controlled delivery of radiofrequency (RF) energy.The aim of this study was to evaluate feasibility, acute efficacy, and safety of an irrigated, temperature-controlled ablation catheter [DiamondTemp™ (DT) Medtronic®] for PVI.Consecutive patients with AF underwent PVI using the DT catheter combined with high-power short-duration RF applications. Ablation settings were (1) a catheter tip temperature limit of 60°C, (2) a temperature-controlled power of 50 W, and (3) application duration of 10 seconds. The primary endpoint was acute isolation of PVs, reassessed after a 30-minute waiting period. Secondary endpoints included procedural parameters (defined as a catheter tip temperature of 50°C > 3 seconds, an impedance drop of 5-10 Ω) and the occurrence of serious adverse events.Fifty consecutive patients [mean age 66 ± 12 years, 38 (76%) women, 24 patients with paroxysmal AF (48%)] were included. Median procedure and left atrial dwell time was 89 [68; 107] and 63 [52; 79] minutes, respectively. Mean number of RF applications was 59 ± 20, and mean total RF duration was 14 ± 6 minutes. Acute PVI was achieved in all patients solely using DT ablation. Acute PV reconnection within the waiting period occurred in five patients; all reconnected PVs were successfully reisolated. One major complication occurred.In this study, the DT ablation system demonstrated high acute efficacy for PVI. Temperature-controlled ablation in conjunction with high-power short-duration applications might be effectively supported.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Anciano , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/cirugía , Resultado del Tratamiento
18.
J Cardiovasc Electrophysiol ; 32(7): 1833-1841, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33955108

RESUMEN

BACKGROUND: The impact of basic atrial rhythm (sinus rhythm [SR] vs. atrial fibrillation [AF]) during AF ablation on efficacy and safety is unknown. METHODS: About 3375 patients from the German Ablation Registry undergoing first-time AF ablation were divided according to the type of AF and the basic atrial rhythm during the ablation procedure: paroxysmal AF (PAF) and SR [group Ia], PAF and AF [group Ib]), persistent AF and SR (IIa), and persistent AF and AF (IIb). RESULTS: Patients in SR (n = 2312 [67%]) underwent cryoballoon ablation more often (Ia vs. Ib p = .002 and IIa vs. IIb p = .010, whereas in patients in AF (n = 1063 [33%]) radiofrequency (RF)-based ablation (Ia vs. Ib p = .006 and IIa vs. IIb p = .014) including left and/or right atrial substrate modification was more frequently performed. Depending on the basic rhythm there was no difference regarding arrhythmia recurrence during long-term follow-up. For patients suffering from persistent AF acute procedure-related complications were more often documented when ablated in AF (9.1% vs. 4.6%, p = .012). which was mainly driven by the higher occurrence of pericardial effusion/tamponade. For patients suffering from persistent AF, favorable results were found regarding 366-day Kaplan-Meier estimates of the incidence of MACCE (death, myocardial infarction, and stroke; p = .011) and the composite endpoint of death, myocardial infarction, stroke, and major bleeding (p = .006), when ablated in SR. CONCLUSION: Basic atrial rhythm at the time of AF ablation did not affect long-term rhythm outcome. For patients suffering from persistent AF a more favorable acute and long-term safety profile was observed when ablated in SR.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Atrios Cardíacos , Humanos , Recurrencia , Sistema de Registros , Resultado del Tratamiento
19.
Pacing Clin Electrophysiol ; 44(9): 1504-1515, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34289168

RESUMEN

PURPOSE: Recently, a novel cardiac imaging system based on a wide-band dielectric technology (KODEX-EPD) was introduced to guide catheter ablation. The aim of the study was to evaluate this 3D wide-band dielectric imaging system (WDIS) during cryoballoon (CB)-based atrial fibrillation (AF) ablation focusing on accuracy of pulmonary vein (PV)-anatomy. METHODS: In consecutive patients with symptomatic AF, CB-based ablation was performed in conjunction with the 3D WDIS. Selective PV-angiographies were performed, and 3D anatomy of the left atrium (LA) and PVs using the 3D WDIS was created. The ostial diameters of the ipsilateral right-sided and left-sided PVs and ostial diameters of the right-/left-sided upper/lower PVs demonstrated by selective angiographies were analyzed and compared to 3D WDIS-based PV visualization. RESULTS: In 65 patients (42/65 (65%) male, age 65 ± 9 years, 29/65 (45%) paroxysmal AF) a total of 260 PVs were identified. Median ostial PV-diameters for the ipsilateral left- and right-sided PVs were 38 [34; 43] and 37 [34; 40.3] mm when assessed fluoroscopically and 40 [35.7; 43] and 39 [35.0; 43] mm as demonstrated by 3D WDIS. There was no statistically significant difference between both methods regarding PV-diameter measurements. KODEX-EPD overestimated fluoroscopy measurements by 1.08 mm (95% limits of agreement of -1.93 mm and 4.1 mm). CONCLUSION: The novel wide-band dielectric 3D-imaging system is feasible to create high-resolution images of cardiac structures during CB ablation procedures and accurately visualizes PV-anatomy.


Asunto(s)
Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Criocirugía/métodos , Imagenología Tridimensional/métodos , Anciano , Angiografía , Femenino , Fluoroscopía , Humanos , Masculino , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía
20.
J Thromb Thrombolysis ; 51(1): 74-80, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32447744

RESUMEN

Stroke after catheter ablation (CA) of atrial fibrillation (AF) is a potential complication with long term consequences. Aim of this study was to determine incidence and potential predictors of stroke and left atrial appendage (LAA) thrombi after AF ablation with cryo-energy. Two hundred nine consecutive patients with symptomatic drug refractory AF (65% male; 61 ± 11 yo, 69% paroxysmal AF, mean CHA2DS2-VASc score 2 ± 1.4) were enrolled between October 2012 until December 2015. Long term follow-up was performed with outpatient clinic visits at 6-month intervals. Incidence of stroke after CA was 1.4% (3/209 pts) at long term follow-up. Two out of 3 pts experienced stroke during the first 3 month after CA and one after 36 months. At long term follow-up LAA thrombi were found in two patients (1%) that were on therapeutic oral anticoagulation. Recurrence of AF was found in 4 out of 5 pts with stroke or LAA thrombi. Patients with stroke or LAA thrombi did not differed from those without in term of age, gender, CV risk factors, LA size and AF type. They differed only for EHRA score (2.4 vs 1.3, p = 0.01) before CA. At multivariate analysis after correction for age, gender, LA size, LVEF and AF type, only EHRA score (ß 1.92, 95% C.I. 1.3-35 p = 0.02), was an independent predictor of stroke/LAA thrombi. Incidence of stroke after cryoablation is low, with a relative higher prevalence during the first 3 months after CA. Prospective, multicenter long-term registries are needed for a better stroke risk stratification.


Asunto(s)
Apéndice Atrial/patología , Fibrilación Atrial/cirugía , Criocirugía/efectos adversos , Accidente Cerebrovascular/etiología , Trombosis/etiología , Anciano , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Pronóstico , Accidente Cerebrovascular/diagnóstico , Trombosis/diagnóstico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA