Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 67
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Artif Organs ; 48(7): 753-762, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38404240

RESUMEN

BACKGROUND: New versions of the polyester polymer alloy (PEPA) membrane have appeared over the years, with increases in both the pore size and the amount of polyvinylpyrrolidone (PVP) to optimize hydrophilicity performance. This study aimed to assess the efficacy of the most recently developed PEPA dialyzer, the FDY series, in hemodialysis (HD) modality in terms of uremic toxin removal and albumin loss and to compare it with that of several high-flux dialyzers currently used in HD and post-dilution hemodiafiltration (HDF) treatments. METHODS: A prospective study was carried out in 21 patients. All patients underwent six dialysis sessions with the same routine dialysis parameters; only the dialyzer and/or the dialysis modality varied: FX80 in HD, FDY 180 in HD, Clearum HS17 in HDF, Elisio 19H in HDF, Vitapes 180 in HDF, and FX80 in post-dilution HDF. The reduction ratios (RR) of urea, creatinine, ß2-microglobulin, myoglobin, κFLC, prolactin, α1-microglobulin, α1-acid glycoprotein, λFLC, and albumin were compared intraindividually. Dialysate albumin loss was also measured. RESULTS: Both membranes FDY and FX80 are high-flux dialyzers and are applied here in high-flux HD. The average RR of ß2-microglobulin was slightly lower in the two HD treatments than in the HDF treatments. Comparison of dialysis treatments revealed that the PEPA FDY dialyzer in the HD modality was more effective than the FX80 dialyzer in high-flux HD and was as effective as post-dilution HDF, especially in terms of myoglobin, κFLC, prolactin, α1-microglobulin, and λFLC RRs. The FDY treatments obtained similar albumin RR in blood and slightly higher dialysate albumin loss, although the values were clinically acceptable. CONCLUSIONS: The most recently developed PEPA dialyzers in the HD modality were as effective as all treatments in the HDF modality and were clearly superior to high-flux helixone HD treatment. These results confirm that this dialyzer should be categorized within the medium cut-off (MCO) membrane classification.


Asunto(s)
Membranas Artificiales , Poliésteres , Diálisis Renal , Humanos , Masculino , Diálisis Renal/instrumentación , Diálisis Renal/métodos , Persona de Mediana Edad , Femenino , Anciano , Estudios Prospectivos , Poliésteres/química , Aleaciones/química , Anciano de 80 o más Años , Hemodiafiltración/instrumentación , Hemodiafiltración/métodos , Adulto , Polímeros/química
2.
Am J Nephrol ; 54(7-8): 291-298, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37311444

RESUMEN

INTRODUCTION: Adherence to a low-sodium (Na) diet is crucial in patients under hemodialysis, as it improves cardiovascular outcomes and reduces thirst and interdialytic weight gain. Recommended salt intake is lower than 5 g/day. The new 6008 CAREsystem monitors incorporate a Na module that offers the advantage of estimating patients' salt intake. The objective of this study was to evaluate the effect of dietary Na restriction for 1 week, monitored with the Na biosensor. METHODS: A prospective study was conducted in 48 patients who maintained their usual dialysis parameters and were dialyzed with a 6008 CAREsystem monitor with activation of the Na module. Total Na balance, pre-/post-dialysis weight, serum Na (sNa), changes in pre- to post-dialysis sNa (ΔsNa), diffusive balance, and systolic and diastolic blood pressure were compared twice, once after 1 week of patients' usual Na diet and again after another week with more restricted Na intake. RESULTS: Restricted Na intake increased the percentage of patients on a low-Na diet (<85 Na mmol/day) from 8% to 44%. Average daily Na intake decreased from 149 ± 54 to 95 ± 49 mmol, and interdialytic weight gain was reduced by 460 ± 484 g per session. More restricted Na intake also decreased pre-dialysis sNa and increased both intradialytic diffusive balance and ΔsNa. In hypertensive patients, reducing daily Na by more than 3 g Na/day lowered their systolic blood pressure. CONCLUSIONS: The new Na module allowed objective monitoring of Na intake, which in turn could permit more precise personalized dietary recommendations in patients under hemodialysis.


Asunto(s)
Cloruro de Sodio Dietético , Sodio , Humanos , Estudios Prospectivos , Diálisis Renal/métodos , Dieta Hiposódica , Presión Sanguínea , Aumento de Peso
3.
Blood Purif ; 52(1): 68-74, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-35551384

RESUMEN

INTRODUCTION: The medium cut-off Elisio HX dialyzer by Nipro became commercially available in Europe in 2021, but there are still no reports of in vivo data. This study aimed to evaluate the safety and efficacy of it compared with previously evaluated hemodialysis (HD), expanded HD (HDx), and postdilution hemodiafiltration (HDF) treatments. METHODS: A prospective study was carried out on 18 patients who underwent 5 dialysis sessions: FX80 Cordiax in HD, Elisio H19 in HD, Elisio HX19 in HDx, Theranova 400 in HDx, and FX80 Cordiax in HDF. The reduction ratios of urea, creatinine, ß2-microglobulin, myoglobin, kappa FLC, prolactin, α1-microglobulin, α1-acid glycoprotein, lambda FLC, and albumin were compared. Dialysate albumin loss was measured. RESULTS: The comparison between the different dialysis modalities revealed no difference for small molecules, but HDx and HDF were significantly more efficient than HD for medium and large molecule removal. The efficacy of Elisio HX19 dialyzer in HDx was similar to the Theranova 400, superior to both dialyzers in HD, and slightly lower than HDF. Albumin losses in dialysate with HD dialyzers were less than 1 g, but between 1.5 and 2.5 g in HDx and HDF. The global removal score (GRS) values with HDx treatments were statistically significantly higher than those with HD. The highest GRS was obtained with the helixone dialyzer in HDF. CONCLUSIONS: The new MCO dialyzer, Elisio HX, performs with excellent behavior and tolerance. It represents an upgrade compared to their predecessor and is very close to the removal capacity of HDF treatment.


Asunto(s)
Hemodiafiltración , Diálisis Renal , Humanos , Estudios Prospectivos , Hemodiafiltración/efectos adversos , Albúminas , Soluciones para Diálisis
4.
Artif Organs ; 45(9): E317-E323, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33908062

RESUMEN

Toray has created a new generation of dialyzers, the polysulphone (TS) UL series, and polymethylmethacrylate (PMMA) NF-U series, which offer enhanced efficacy over the previous TS-S series and NF-H series. The aim of this study was to evaluate the safety and efficacy of these dialyzer series versus contrasted expanded hemodialysis (HDx) and postdilution hemodiafiltration (HDF). We conducted a prospective study in 12 patients. Each patient underwent six dialysis sessions: FX80 Cordiax in HD, Toraysulfone TS-1.8 UL in HD, Theranova 400 in HDx, polymethylmethacrylate (PMMA) NF-2.1 U in HDF, Toraysulfone TS-2.1 UL in HDF, and FX80 Cordiax in HDF. The removal ratios (RRs) of urea, creatinine, ß2 -microglobulin, myoglobin, prolactin, α1 -microglobulin, α1 -acid glycoprotein, and albumin were compared intraindividually. Dialysate albumin loss was also measured. The RRs for ß2 -microglobulin, myoglobin, prolactin, α1 -microglobulin, and α1 -acid glycoprotein were higher with the TS-2.1 UL and FX80 Cordiax dialyzers in HDF than those obtained with HD treatments and NF-2.1 U in HDF. The ß2 -microglobulin, myoglobin, and prolactin RRs were also higher with HDx than those obtained with HD treatments. The myoglobin and prolactin RRs were higher with TS-1.8 UL in HD than those obtained with helixone dialyzers in HD. Dialysate albumin loss was less than 3 g in all situations except in TS-2.1 UL in HDF. The highest global removal score values were obtained with the TS-2.1 UL and helixone dialyzers in HDF. Significant differences were found between all study situations. In conclusion, the new generation dialyzers, Toraysulfone TS Series UL and PMMA NF-U series, show excellent behaviour and tolerance in HD and HDF, representing an upgrade versus their predecessor series. The higher permeability of the TS UL series has been proven with higher efficiency in HD and maximum performance in HDF. The new PMMA NF-U series allows the use of HDF with good efficiency and complete safety.


Asunto(s)
Hemodiafiltración/instrumentación , Enfermedades Renales/terapia , Membranas Artificiales , Polímeros/química , Polimetil Metacrilato/química , Sulfonas/química , Anciano , Biomarcadores/sangre , Femenino , Humanos , Enfermedades Renales/sangre , Masculino , Persona de Mediana Edad , Estudios Prospectivos
5.
Artif Organs ; 45(10): 1195-1201, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33978975

RESUMEN

The Clearum dialyzer, built by Medtronic, became commercially available in several European countries in 2020, but there are still no reports of in vivo data. The aim of this study was to evaluate the efficacy and risk of hypoalbuminemia of this dialyzer compared with previously evaluated hemodialysis (HD), expanded hemodialysis (HDx), and postdilution hemodiafiltration (HDF) treatments. A prospective study was carried out in 15 patients. Each patient underwent seven dialysis sessions: FX80 Cordiax in HD, Clearum HS17 in HD, Phylther 17-SD in HDx, Theranova 400 in HDx, Phylther 17-G in postdilution HDF, Clearum HS17 in postdilution HDF, and FX80 Cordiax in postdilution HDF. The reduction ratios of urea, creatinine, ß2 -microglobulin, myoglobin, prolactin, α1 -microglobulin, α1 -acid glycoprotein, and albumin were compared intraindividually. Dialysate albumin loss was also measured. Comparison of dialysis techniques revealed no differences between small molecules, but HDx and HDF were significantly higher than HD with medium and large molecular weights. The Clearum dialyzer in HDF obtained similar results to FX80 Cordiax in HDF, was slightly superior to Phylther 17-G in HDF, and was statistically superior to both dialyzers in HDx. Albumin losses with the Clearum dialyzer were among the lowest, both in HD and HDF treatments. The highest global removal score (GRS) values were obtained with the helixone and Clearum dialyzers in HDF, with similar results both in HD and HDF. In addition, the GRS values with HDx treatments were statistically significantly higher than those with HD. The new Clearum dialyzer has excellent behavior and tolerance in HD and HDF. Its adequate permeability has been proven with its maximal performance in HDF, which could represent an upgrade versus its predecessor polyphenylene dialyzers.


Asunto(s)
Hemodiafiltración/instrumentación , Fallo Renal Crónico/terapia , Diálisis Renal/instrumentación , Anciano , Anciano de 80 o más Años , alfa-Globulinas/análisis , Creatinina/sangre , Femenino , Hemodiafiltración/métodos , Humanos , Masculino , Persona de Mediana Edad , Mioglobina/sangre , Orosomucoide/análisis , Seguridad del Paciente , Prolactina/sangre , Estudios Prospectivos , Diálisis Renal/métodos , Resultado del Tratamiento , Urea/sangre , Microglobulina beta-2/sangre
6.
Blood Purif ; 50(4-5): 531-538, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33352569

RESUMEN

INTRODUCTION: COVID-19 is a highly contagious disease that has easily spread worldwide. Outpatient maintenance hemodialysis seems to entail an increased risk of contagion, and previous reports inform of increased mortality among this population. METHODS: We retrospectively analyzed clinical and laboratory parameters, outcomes, and management once discharged of CKD-5D patients infected with SARS-CoV-2 from our health area. RESULTS: Out of the 429 CKD-5D population, 36 were diagnosed with SARS-CoV-2 infection (8%): 34 on in-center hemodialysis and 2 on peritoneal dialysis. Five were asymptomatic. The most common symptom was fever (70%), followed by dyspnea and cough. History of cardiovascular disease and elevation of LDH and C-reactive protein during admission were associated with higher mortality. Thirteen patients died (36%), 8 patients were admitted to an ICU, and survival was low (38%) among the latter. The mean time to death was 12 days. Most discharged patients got negative rRT-PCR in nasopharyngeal swabs within 26 days of diagnosis. However, there is a portion of cured patients that continue to have positive results even more than 2 months after the initial presentation. CONCLUSIONS: Patients on dialysis have an increased mortality risk if infected with SARS-CoV-2. Preventive measures have proven useful. Thus, proper ones, such as universal screening of the population and isolation when required, need to be generalized. Better de-isolation criteria are necessary to ensure an appropriate use of public health resources.


Asunto(s)
COVID-19/epidemiología , Aislamiento de Pacientes , Insuficiencia Renal Crónica/epidemiología , SARS-CoV-2 , Cuidados Posteriores , Anciano , Anciano de 80 o más Años , Infecciones Asintomáticas/epidemiología , COVID-19/diagnóstico , COVID-19/prevención & control , COVID-19/transmisión , Prueba de COVID-19 , Enfermedades Cardiovasculares/epidemiología , Comorbilidad , Diabetes Mellitus/epidemiología , Dislipidemias/epidemiología , Femenino , Fiebre/etiología , Mortalidad Hospitalaria , Humanos , Huésped Inmunocomprometido , Masculino , Persona de Mediana Edad , Diálisis Peritoneal , Prevalencia , Pronóstico , Diálisis Renal , Insuficiencia Renal Crónica/terapia , Índice de Severidad de la Enfermedad , Fumar/epidemiología , España/epidemiología , Sobrevivientes
7.
Am J Nephrol ; 51(5): 357-365, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32187607

RESUMEN

BACKGROUND: Recurrence of immunoglobulin (Ig)A nephropathy (rIgAN) is a growing cause of kidney allograft dysfunction. This study was aimed at investigating factors associated with rIgAN and the subsequent progression to end-stage renal disease (ESRD). METHODS: Retrospective study including consecutive patients with IgA nephropathy (IgAN) who received a kidney transplant in our center between 1992 and 2016 and had a renal biopsy by clinical indication. The date of detection of chronic kidney disease (CKD) 5 was used as renal outcome. RESULTS: Eighty-six kidney transplants were performed in patients with IgAN, 38 (44%) were from living donors (related n = 26). rIgAN was diagnosed in 23 allografts (27%). Renal function and proteinuria at the end of the follow-up period were worst in the rIgAN patients compared to those without rIgAN (2.2 vs. 1.4 mg/dL, p = 0.014, and 1.16 vs. 0.49 g/day, p = 0.005, respectively). Risk of rIgAN and progression to CKD 5 decreased with patient's age (hazard ratio [HR] 0.95, 95% CI 0.92-0.98, p = 0.002, and HR 0.97, 95% CI 0.83-0.97, p = 0.008 per year, respectively). Patients with rIgAN had a higher risk of progression to CKD 5 (HR 6.7, 95% CI 1.3-35.7, p = 0.025). Full donor-recipient mismatch in the human leukocyte antigen (HLA)-B loci decreased the risk of rIgAN (HR 0.22, 95% CI 0.06-0.76, p = 0.017). CONCLUSIONS: rIgAN was an independent risk factor for ESRD after renal allograft. Younger age increased the risk of rIgAN and CKD 5. Conversely, HLA-B mismatching was a potential protective factor for rIgAN of this glomerular disease.


Asunto(s)
Glomerulonefritis por IGA/diagnóstico , Antígenos HLA-B/inmunología , Fallo Renal Crónico/cirugía , Trasplante de Riñón/efectos adversos , Adulto , Factores de Edad , Aloinjertos/inmunología , Aloinjertos/patología , Biopsia , Progresión de la Enfermedad , Femenino , Estudios de Seguimiento , Glomerulonefritis por IGA/complicaciones , Glomerulonefritis por IGA/inmunología , Glomerulonefritis por IGA/cirugía , Antígenos HLA-B/análisis , Prueba de Histocompatibilidad , Humanos , Riñón/inmunología , Riñón/patología , Fallo Renal Crónico/inmunología , Masculino , Persona de Mediana Edad , Factores Protectores , Recurrencia , Estudios Retrospectivos , Factores de Riesgo , Trasplante Homólogo
8.
Artif Organs ; 44(10): E448-E458, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32279348

RESUMEN

The aim of the study was to compare expanded hemodialysis (HDx) with hemodiafiltration (HDF) at different infusion flows to identify the main determinants, namely blood flow (Qb), replacement volume, infusion flow (Qi), ultrafiltration flow (Quf ), filtration fraction (FF), and the point at which the effectiveness of HDF equals or exceeds that of HDx. We conducted a prospective, single-center study in 12 patients. Each patient underwent 12 dialysis sessions: six sessions with Qb 350 and six with Qb 400 mL/min; with each Qb, one session was with HDx and five sessions were with FX80 (one in HD, and four with Qi 50, 75, 90/100 mL/min or autosubstitution in postdilution HDF). The reduction ratios (RR) of urea, creatinine, ß2 -microglobulin, myoglobin, prolactin, α1 -microglobulin, α1 -acid glycoprotein, and albumin were compared intraindividually and the global removal score (GRS) was calculated. The mean replacement volume with Qb 350 mL/min was 13.77 ± 0.92 L with Qi 50 mL/min, 20.75 ± 1.17 L with Qi 75, 23.83 ± 1.92 L with Qi 90, and 27.51 ± 2.77 L with autosubstitution. Similar results were obtained with Qb 400 mL/min, and the results were only slightly higher with Qi 100 mL/min or in autosubstitution. The GRS was positively correlated with replacement volume with Qb 350 (R2  = 0.583) and with Qb 400 (R2  = 0.584); with Quf with Qb 350 (R2  = 0.556) and with Qb 400 (R2  = 0.604); and also with FF with Qb 350 (R2  = 0.556) and with Qb 400 mL/min (R2  = 0.603). The minimum convective volume in HDF from which it is possible to overcome the efficacy of HDx was 19.2 L with Qb 350 and 17.6 L with Qb 400 mL/min. The cut-off point of Quf at which HDF exceeded the effectiveness of HDx was 80.6 mL/min with Qb 350 and 74.1 mL/min with Qb 400 mL/min. The cut-off point at which FF in HDF exceeded the effectiveness of the HDx was 23.0% with Qb 350 and 18.6% with Qb 400 mL/min. In conclusion, this study confirms the superiority of postdilution HDF over HDx when replacement volume, convective volume, Quf , or FF exceeds certain values. Increasing the Qb in postdilution HDF manages to increase the convective dose and more easily overcome the HDx.


Asunto(s)
Hemodiafiltración/estadística & datos numéricos , Fallo Renal Crónico/terapia , Diálisis Renal/estadística & datos numéricos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Fallo Renal Crónico/sangre , Fallo Renal Crónico/orina , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Resultado del Tratamiento
9.
Blood Purif ; 49(4): 400-408, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31865336

RESUMEN

BACKGROUND: The biocompatibility of dialysis membranes is a determining factor in avoiding chronic microinflammation in patients under haemodialysis. Lower biocompatibility has been related to increased inflammatory status, which is known to be associated with cardiovascular events. Classically, cellulose membranes have been considered bioincompatible. A new-generation of asymmetric cellulose triacetate (CTA) membranes allows the performance of high convective transport techniques, but there have been no studies of their biocompatibility. The aim of the present study was to analyze and compare the biocompatibility characteristics of 4 membranes, including CTA, in online hemodiafiltration (OL-HDF) patients. METHODS: We included 15 patients in -OL-HDF. After a 2-week washout period with helixone membrane, each patient was treated with the 4 membranes (polyamide, polynephron, helixone and CTA) for 4 weeks in a randomized order. The other dialysis parameters were kept stable throughout the study. We studied changes in markers of the activation of the complement system, monocytes, platelets, and adhesion molecules with the 4 membranes, as well as inflammatory parameters. RESULTS: Biocompatibility was similar among the membranes. There were no sustained differences in complement activation, measured by C3a and C5a levels, or in platelet activation, determined by levels of P-selectin and platelet-derived microparticles (CD41a+). No differences were observed in activated monocyte levels (CD14+/CD16+) or in plasma levels of interleukin (IL)-1, IL-6, IL-10 or high-sensitivity C-reactive protein, although tumour necrosis factor-α levels decreased when the patients were dialyzed with CTA. No significant differences were found in markers of endothelial damage, assessed by levels of plasminogen activator inhibitor-1 and adhesion molecules (intercellular adhesion molecule-1 and vascular cell adhesion molecule-1). CONCLUSION: The 4 membranes evaluated in this study in stable patients on OL-HDF, including the new-generation CTA, show similar biocompatibility with the methods applied.


Asunto(s)
Materiales Biocompatibles/química , Hemodiafiltración/instrumentación , Ensayo de Materiales , Membranas Artificiales , Adulto , Anciano , Anciano de 80 o más Años , Materiales Biocompatibles/efectos adversos , Celulosa/efectos adversos , Celulosa/análogos & derivados , Celulosa/química , Activación de Complemento , Femenino , Humanos , Interleucinas/sangre , Masculino , Persona de Mediana Edad , Activación Plaquetaria
10.
Artif Organs ; 43(10): 1014-1021, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31038748

RESUMEN

Most high-flux dialyzers can be used in both hemodialysis (HD) and online hemodiafiltration (OL-HDF). However, some of these dialyzers have higher permeability and should not be prescribed for OL-HDF to avoid high albumin losses. The aim of this study was to compare the safety and efficacy of a currently used dialyzer in HD and OL-HDF with those of several other high permeability dialyzers which should only be used in HD. A prospective, single-center study was carried out in 21 patients. Each patient underwent 5 dialysis sessions with routine dialysis parameters: 2 sessions with Helixone (HD and postdilution OL-HDF) and 1 session each with steam sterilized polyphenylene, polymethylmethacrylate (PMMA), and medium cut-off (MCO) dialyzers in HD treatment. The removal ratios (RR) of urea, creatinine, ß2 -microglobulin, myoglobin, prolactin, α1 -microglobulin, α1 -acid glycoprotein, and albumin were compared intraindividually. A proportional part of the dialysate was collected to quantify the loss of various solutes, including albumin. Urea and creatinine RRs with the Helixone-HDF and MCO dialyzers were higher than with the other 3 dialyzers in HD. The ß2 -microglobulin, myoglobin and prolactin RRs with Helixone-HDF treatment were significantly higher than those obtained with all 4 dialyzers in HD treatment. The ß2 -microglobulin value obtained with the MCO dialyzer was also higher than that obtained with the other 3 dialyzers in HD treatment. The myoglobin RR with MCO was higher than those obtained with Helixone and PMMA in HD treatment. The prolactin RR with Helixone-HD was significantly lower than those obtained in the other 4 study sessions. The α1 -microglobulin and α1 - acid glycoprotein RRs with Helixone-HDF were significantly higher than those obtained with Helixone and PMMA in HD treatment. The albumin loss varied from 0.54 g with Helixone-HD to 3.3 g with polyphenylene. The global removal score values ((UreaRR + ß2 -microglobulinRR + myoglobinRR + prolactinRR + α1 -microglobulinRR + α1 -acid glycoproteinRR - albuminRR )/6) were 43.7% with Helixone-HD, 47.7% with PMMA, 54% with polyphenylene, 54.8% with MCO and 59.6% with Helixone-HDF, with significant differences. In conclusion, this study confirms the superiority of OL-HDF over HD with the high-flux dialyzers that allow both treatments. Although new dialyzers with high permeability can only be used in HD, they are in an intermediate position and some are very close to OL-HDF.


Asunto(s)
Hemodiafiltración/instrumentación , Fallo Renal Crónico/terapia , Anciano , alfa-Globulinas/aislamiento & purificación , Soluciones para Diálisis/uso terapéutico , Femenino , Hemodiafiltración/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Mioglobina/aislamiento & purificación , Permeabilidad , Prolactina/aislamiento & purificación , Estudios Prospectivos , Diálisis Renal/efectos adversos , Diálisis Renal/instrumentación , Albúmina Sérica/aislamiento & purificación , Urea/aislamiento & purificación , Microglobulina beta-2/aislamiento & purificación
11.
Blood Purif ; 48(2): 167-174, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30943486

RESUMEN

BACKGROUND: A novel class of membranes, medium cut-off (MCO) membranes, has recently been designed to achieve interesting removal capacities for middle and large middle molecules in hemodialysis (HD) treatments. The few studies published to date have reported contradictory results regarding middle-sized molecules when comparing MCO dialyzers versus dialyzers used in online hemodiafiltration (OL-HDF). METHODS: A prospective, single-center study was carried out in 22 patients. Each patient underwent 9 dialysis sessions with routine dialysis parameters, one with an MCO dialyzer in HD and the other 8 with different dialyzers in OL-HDF. The removal ratio (RR) of urea, creatinine, ß2-microglobulin, myoglobin, prolactin, α1-microglobulin, α1-acid glycoprotein, and albumin was intraindividually compared. Albumin loss in dialysate was measured. We propose a global removal score ([ureaRR + ß2-microglobulinRR + myoglobinRR + prolactinRR + α1-microglobulinRR + α1-acid glycoproteinRR]/6 - albuminRR) as a new tool for measuring dialyzer effectiveness. RESULTS: No significant differences in the RRs of small and middle molecular range molecules were observed between the MCO vs. OL-HDF dialyzers (range 60-80%). Lower RRs were found for α1-microglobulin and α1-acid glycoprotein without significant differences. The albumin RR was < 11% and dialysate albumin loss was < 3.5 g in all situations without significant differences. The global removal score was 54.9 ± 4.8% with the MCO dialyzer without significant differences. CONCLUSIONS: Removal of a wide range of molecular weights, calculated with the proposed global removal score, was almost equal with the MCO dialyzer in HD treatment compared with 8 high-flux dialyzers in high-volume OL-HDF without relevant changes in albumin loss. The global removal score could be a new tool to evaluate the effectiveness of dialyzers and/or different treatment modalities.


Asunto(s)
Hemodiafiltración/instrumentación , Fallo Renal Crónico/sangre , Fallo Renal Crónico/terapia , Diálisis Renal/instrumentación , Adulto , Anciano , Anciano de 80 o más Años , alfa-Globulinas/análisis , alfa-Globulinas/aislamiento & purificación , Creatinina/sangre , Creatinina/aislamiento & purificación , Femenino , Hemodiafiltración/métodos , Humanos , Masculino , Persona de Mediana Edad , Mioglobina/sangre , Mioglobina/aislamiento & purificación , Estudios Prospectivos , Diálisis Renal/métodos , Albúmina Sérica/análisis , Albúmina Sérica/aislamiento & purificación , Urea/sangre , Urea/aislamiento & purificación , Adulto Joven , Microglobulina beta-2/sangre , Microglobulina beta-2/aislamiento & purificación
12.
Blood Purif ; 48(2): 106-114, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30699421

RESUMEN

BACKGROUND: Etelcalcetide is a novel second-generation calcimimetic that, because of its intravenous administration, could improve treatment adherence in secondary hyperparathyroidism (SHPT). The aim of this study was to evaluate the effectiveness of etelcalcetide compared with that of cinacalcet in controlling SHPT in patients under hemodialysis. METHODS: A prospective observational study was performed in 29 patients with SHPT under hemodialysis who switched from cinacalcet to etelcalcetide with a follow-up of 6 months. A survey was conducted of adherence to the oral calcimimetic. The primary end-point of the study was to assess whether etelcalcetide was more effective than cinacalcet in controlling SHPT. RESULTS: After the switch of treatment, none of the patients developed clinical intolerance or new adverse effects. Etelcalcetide was more effective than cinacalcet in controlling intact parathyroid hormone (iPTH), with an overall decrease in iPTH levels that was significant from the second month. Average calcium levels remained within the normal range, with a higher percentage of hypocalcemia with etelcalcetide (6.9 vs. 13.8%), which was asymptomatic in all cases. Patients who were nonadherent to cinacalcet (38%) showed a significant reduction in calcium and iPTH during follow-up with etelcalcetide. The adherent group (62%) also showed a trend to lower iPTH levels reaching statistical significance after 5 months of follow-up. The dose conversion factor for the switch from cinacalcet to etelcalcetide was etelcalcetide/session = 0.111*mg cinacalcet/day + 0.96, R2 = 0.57. CONCLUSIONS: Etelcalcetide was more effective than cinacalcet in this patient population, especially in the nonadherent subgroup, leading to better SHPT control without adverse effects.


Asunto(s)
Hormonas y Agentes Reguladores de Calcio/uso terapéutico , Cinacalcet/uso terapéutico , Hiperparatiroidismo Secundario/tratamiento farmacológico , Péptidos/uso terapéutico , Administración Intravenosa , Administración Oral , Adulto , Anciano , Anciano de 80 o más Años , Calcio/sangre , Hormonas y Agentes Reguladores de Calcio/administración & dosificación , Cinacalcet/administración & dosificación , Femenino , Humanos , Hiperparatiroidismo Secundario/sangre , Hiperparatiroidismo Secundario/terapia , Masculino , Persona de Mediana Edad , Cooperación del Paciente , Péptidos/administración & dosificación , Estudios Prospectivos , Diálisis Renal , Adulto Joven
13.
Gastroenterol Hepatol ; 42(3): 164-170, 2019 Mar.
Artículo en Inglés, Español | MEDLINE | ID: mdl-30293914

RESUMEN

INTRODUCTION: In the interferon era, the treatment of hepatitis C virus (HCV) infection in patients on haemodialysis (HD) was limited due to the significant number of treatment-related adverse events (AEs). Direct-acting antivirals (DAAs) have demonstrated their efficacy and safety in the treatment of HCV in patients with advanced chronic kidney disease on haemodialysis. The objective of the study was to evaluate the success in eliminating HCV infection from our dialysis unit using DAAs, and to assess the impact of HCV elimination on clinical and analytical outcomes. PATIENTS AND METHODS: This is a prospective, interventional, single-center study at Hospital Clínic de Barcelona. All HCV-RNA positive patients who received antiviral therapy with DAAs within a 3-year period (2014-2017) were analyzed (n=20). Data on virologic response, adverse events, and biochemical and hematological parameters during and after DAA therapy were analyzed. RESULTS: All patients achieved sustained virologic response (SVR) and only 40% of patients presented with mild AEs. None of the patients presented with HCV reinfection after a 1-year follow-up period, and thus HCV was eliminated from our HD unit. SVR was associated with a significant increase in hemoglobin and hematocrit, and a tendency toward the need for lower doses of iron supplementation with no changes in darbepoetin dose. CONCLUSION: HCV infection can be safely eliminated from HD units with the use of DAAs, preventing new infections in patients and healthcare staff. In the short term, the achievement of SVR is associated with an improvement in the control of anemia.


Asunto(s)
Anemia/tratamiento farmacológico , Antivirales/uso terapéutico , Hepatitis C/tratamiento farmacológico , Diálisis Renal , Insuficiencia Renal Crónica/terapia , Respuesta Virológica Sostenida , 2-Naftilamina , Anemia/etiología , Anilidas , Carbamatos , Ciclopropanos , Darbepoetina alfa/administración & dosificación , Femenino , Hematínicos/administración & dosificación , Hematócrito , Hemoglobina A , Humanos , Lactamas Macrocíclicas , Compuestos Macrocíclicos/uso terapéutico , Masculino , Persona de Mediana Edad , Prolina/análogos & derivados , Estudios Prospectivos , Insuficiencia Renal Crónica/complicaciones , Ritonavir/uso terapéutico , Sulfonamidas/uso terapéutico , Uracilo/análogos & derivados , Uracilo/uso terapéutico , Valina
14.
Transpl Int ; 30(10): 975-986, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28403541

RESUMEN

There is no consensus on the allocation of renal transplants from expanded criteria donors (ECD). The Kidney Donor Profile Index (KDPI) is used without the need for pretransplant donor biopsies (PTDB). We explored whether PTDB based on Remuzzi Score (RS) allows identification of those marginal kidneys in the highest calculated KDPI risk group (>91%) that appropriate for single transplantation. A retrospective study was conducted of 485 consecutive kidneys procured from a single center and transplanted if the RS was ≤4. We compared 5-year kidney and patients survival between KDPI groups and between RS <4 or =4 in the highest KDPI group. The median KDPI (interquartile range) was 71 (66-76) for KDPI <80% (n = 77), 86 (81-90) for KDPI 81-90% (n = 82), and 97 (94-100) for KDPI >91% (n = 205). Patient survival at 5 years was 85.7%, 85.3%, and 76.09% (P = 0.058) and death-censored graft survival was 84.4%, 86.5%, 73.6% (P = 0.015), respectively for each KDPI group. In >91% calculated KDPI group, there were no differences in graft survival depending on the RS (<4 vs. =4) (P = 0.714). The implementation of PTDB based on RS used for allocation of organs with the highest KDPI range could support to the acceptance of suitable organs for single transplantation with good patient and graft survival rate.


Asunto(s)
Trasplante de Riñón/mortalidad , Riñón/patología , Donantes de Tejidos , Trasplantes/normas , Adulto , Anciano , Anciano de 80 o más Años , Biopsia , Funcionamiento Retardado del Injerto/epidemiología , Femenino , Rechazo de Injerto/epidemiología , Supervivencia de Injerto , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , España/epidemiología
16.
Nephrol Dial Transplant ; 29(9): 1764-9, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-24748668

RESUMEN

BACKGROUND: The phenotype of renal involvement in anti-neutrophil cytoplasmic antibodies (ANCA) vasculitis has a major influence on survival, and histological subgrouping of diagnostic renal biopsies has been proposed to aid in the prediction of renal outcome. We aimed to validate this histological subgrouping and to investigate the additional value of ANCA serotype in the prediction of renal outcome. METHODS: Data were retrospectively collected from the time of diagnosis by systematic review of medical records from 136 patients with renal biopsies recruited to cohorts from the UK and Spain, over 15 years. The end point, renal survival, was the composite of end-stage renal disease (ESRD) or death from any cause. The occurrence of ESRD, Stage 4 Kidney Disease Outcomes Quality Initiative-Chronic Kidney Disease, was assessed separately, in order to establish a severity index risk of chronic kidney disease. RESULTS: Renal survival at 5 years was 96% in the focal, 86% in the crescentic, 81% in the mixed and 61% in the sclerotic subgroups (P = 0.03). Myeloperoxidase (MPO)-ANCA was associated with more severe disease when compared with PR3-ANCA, as demonstrated by a lower frequency of focal and higher frequency of sclerotic subgroups, by more advanced interstitial fibrotic change and by lower glomerular filtration rate at diagnosis and worse renal function at 1 and 2 years. CONCLUSIONS: We have confirmed the predictive value for renal survival of the ANCA vasculitis histology classification in a multi-centre study. We found a worse renal outcome in patients with tubulointerstitial fibrosis and atrophy. MPO-ANCA positive patients had a worse renal prognosis due to more severe glomerular injury. These results contribute to patient stratification in renal vasculitis for therapeutic, epidemiological and basic research.


Asunto(s)
Anticuerpos Anticitoplasma de Neutrófilos/inmunología , Glomerulonefritis/inmunología , Vasculitis Asociada a Anticuerpos Citoplasmáticos Antineutrófilos/inmunología , Femenino , Glomerulonefritis/tratamiento farmacológico , Glomerulonefritis/patología , Humanos , Fallo Renal Crónico/complicaciones , Glomérulos Renales/patología , Masculino , Persona de Mediana Edad , Peroxidasa/inmunología , Estudios Retrospectivos , Serogrupo , Índice de Severidad de la Enfermedad
17.
Nefrologia (Engl Ed) ; 44(3): 354-361, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38679516

RESUMEN

INTRODUCTION: New generation helixone dialyzers has recently been developed as part of the ongoing effort to improve dialyzer hemocompatibility and avoid adverse reactions to synthetic dialyzers. This study aimed to assess the performance and albumin loss of this new dialyzer series in hemodiafiltration and compare it with the previous generation helixone series. MATERIAL AND METHODS: A prospective study was conducted in 19 patients. Each patient underwent eight dialysis sessions with the same routine dialysis parameters; only the dialyzer varied: FX60 CorDiax, FX CorAL 60, FX600 CorDiax, FX CorAL 600, FX80 CorDiax, FX CorAL 80, FX800 CorDiax, and FX CorAL 800. The reduction ratios (RR) of urea, creatinine, ß2-microglobulin, myoglobin, kappa-free immunoglobulin light chains (κFLC), prolactin, α1-microglobulin, α1-acid glycoprotein, lambda immunoglobulin light chains (λFLC), and albumin were compared intra-individually. Dialysate albumin loss was also measured. RESULTS: All treatments were well tolerated. The mean amount of replacement fluid ranged from 31 to 34 L. Comparison of dialysis treatments showed no differences between small molecules and even up to those the size of ß2-microglobulins. Little differences were found between myoglobin, κFLC, prolactin, α1-microglobulin, and λFLC RRs, and only FX80 CorDiax was slightly superior to the others. Mean dialysate albumin losses were similar, with less than 2.5 g lost in each dialyzer. The FX80 CorDiax showed slightly higher global removal scores than the other dialyzers evaluated, except for FX CorAL 800. CONCLUSION: The new generation helixone dialyzers series has been updated to minimise the risk of adverse reactions, while maintaining the effectiveness and albumin loss achieved by the previous most advanced helixone generation.


Asunto(s)
Hemodiafiltración , Humanos , Estudios Prospectivos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Hemodiafiltración/instrumentación , Hemodiafiltración/métodos , Diseño de Equipo , Adulto , Resultado del Tratamiento , Albúmina Sérica/análisis , Anciano de 80 o más Años
18.
Nefrologia (Engl Ed) ; 44(3): 417-422, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38890062

RESUMEN

INTRODUCTION: Changes in plasma sodium concentration (pNa, expressed in mEq/L) are common in hemodialysis (HD) patients. Hemodialysis monitors can estimate pNa by using an internal algorithm based on ion dialysance measurements. The present study studies the accuracy of the correlation between the pNa estimated by the dialysis monitor and that measured by the biochemistry laboratory at our center. MATERIAL AND METHODS: A single-centre prospective observational study in patients on a chronic HD program with the 6008 CAREsystem monitor and standard sodium (138mmol/L) and bicarbonate (32mmol/L) prescriptions. Venous blood samples were drawn from each patient before and after each HD session to ensure inter- and intra-individual validity. The pNa was measured in the biochemistry laboratory using indirect potentiometry and simultaneously the estimated pNa by the HD monitor was recorded at the beginning and at the end of the HD session. For statistical analysis, a scatterplot was made, and Spearman's correlation quotient was calculated. In addition, the differences between both methods were represented as Bland-Altman diagrams. RESULTS: The pre-dialysis pNa measured in the laboratory was 137.49±3.3, and that of the monitor, 137.96±2.91, with a correlation with R2 value of 0.683 (p<0.001). The post-dialysis pNa measured in the laboratory was 137.08±2.23, and that of the monitor was 138.87±1.88, with an R2 of 0.442 (p<0.001). On the Bland-Altman plots, the pre-dialysis pNa has a systematic error of 0.49, in favor of the monitor-estimated pNa, with a 95% confidence interval (CI) of (-3.24 to a 4.22). In the post-dialysis pNa, a systematic error of 1.79 with a 95% CI of (-1.64 to 5.22) was obtained. CONCLUSION: The correlation between the pNa estimated by Fresnius 6008 CAREsystem HD monitor and that measured by the laboratory is good, especially pre-dialysis measurements. Further studies should verify the external validity of these results.


Asunto(s)
Diálisis Renal , Sodio , Humanos , Estudios Prospectivos , Sodio/sangre , Femenino , Masculino , Persona de Mediana Edad , Anciano
19.
Nefrologia (Engl Ed) ; 44(3): 317-322, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38871560

RESUMEN

Contrast-induced encephalopathy is a neurological complication related to contrast used in endovascular procedures or computed tomography (CT). The main risk factors are arterial hypertension, diabetes mellitus, chronic kidney disease (CKD), hyperosmolar contrasts, the amount of infused contrast and its direct infusion in the posterior cerebral territory, or pathologies with blood-brain barrier damage. Symptomatology is non-specific and may present as altered level of consciousness, neurological focality or seizures. Diagnosis is done by exclusion after ischemic or hemorrhagic stroke has been ruled out; CT or MRI are useful for differentiation. Generally, it appears shortly after exposure and the symptoms lasts 48-72h with complete recovery, although cases with persistence of symptoms or longer duration have been described. Treatment consists of monitoring, supportive measures and kidney replacement therapy (KRT) with hemodialysis (HD) in patients in chronic KRT program. It is important for the nephrologist to be aware of this entity given the susceptibility of the patient on HD as well as its potential therapeutic role in these patients.


Asunto(s)
Encefalopatías , Medios de Contraste , Insuficiencia Renal Crónica , Humanos , Insuficiencia Renal Crónica/complicaciones , Insuficiencia Renal Crónica/terapia , Medios de Contraste/efectos adversos , Encefalopatías/inducido químicamente , Nefrología , Factores de Riesgo , Diálisis Renal
20.
J Vasc Access ; 24(1): 155-157, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34121498

RESUMEN

The following paper reports the case of a woman on in-center hemodialysis through an arteriovenous graft, who attended with an acute vascular access thrombosis. Post percutaneous thrombectomy, the patient presented a rare case of self-limited acute hepatitis secondary to the revascularization procedure. We explain the probable trigger for this complication, its pathophysiology, management, and evolution.


Asunto(s)
Derivación Arteriovenosa Quirúrgica , Hepatitis , Trombosis , Femenino , Humanos , Oclusión de Injerto Vascular/diagnóstico por imagen , Oclusión de Injerto Vascular/etiología , Oclusión de Injerto Vascular/cirugía , Grado de Desobstrucción Vascular , Derivación Arteriovenosa Quirúrgica/efectos adversos , Trombectomía/efectos adversos , Trombosis/diagnóstico por imagen , Trombosis/etiología , Trombosis/cirugía , Diálisis Renal/efectos adversos , Hepatitis/complicaciones , Resultado del Tratamiento , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA