Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Eur Biophys J ; 44(5): 349-58, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25921614

RESUMEN

The functional relationship between the velocity of cell locomotion and intracellular spatial patterns of thickness oscillations in the acellular slime mould Physarum polycephalum was studied. The freely migrating plasmodial cells of 300-800 µm length were tadpole-shaped and displayed thickness oscillations along their longitudinal (body) axis. Two distinct patterns of intracellular thickness oscillations were observed in dependence on the locomotive velocity. The first mode consisted of a single travelling wave that propagated from the rear to the front of the cell. This pattern occurred when the plasmodium migrated slowly. The second mode was a multinodal standing wave that was found during events of fast propagation. Transitions between these two types of cell thickness oscillation patterns took place in narrow propagation velocity intervals. We discuss the possible mechanism leading to these patterns, which are conjectured to modulate both the intracellular pressure and the velocity of free locomotion of the cell.


Asunto(s)
Movimiento , Periodicidad , Physarum polycephalum/citología , Modelos Teóricos , Physarum polycephalum/fisiología
2.
Springerplus ; 5(1): 2065, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27995042

RESUMEN

BACKGROUND: Silicon single-photon avalanche diodes (Si-SPADs) are the most used devices for measuring ultra-weak optical radiant fluxes in many quantum technology fields, such as quantum optics, quantum communication, quantum computing, etc. In all these fields, the detection efficiency is the main parameter, which has to be accurately known for achieving reliable measurements. In this paper we present the improvements performed on the setup described in López et al. (J Mod Opt 62:S21-S27, 2015) for determining the detection efficiency of Si-SPAD detectors with a low measurement uncertainty. The improvement arises from the precise alignment of the Si-SPAD detector and the low deviation reached between the total calculated filter transmission and the individual filter transmission measurements (≤0.05%) performed with an integrating sphere with attached Si-photodiode as standard detector. RESULTS: The relative standard uncertainty of the Si-SPAD detection efficiency measurement achieved is now as low as ~0.16%. Furthermore, the investigation of the detection efficiency homogeneity of two commercial Si-SPAD detectors from different manufacturers and with different sensor diameters is also presented. The obtained homogeneity is ≤2.2% within a region of diameter of 40 µm. CONCLUSIONS: The detailed analysis presented in this paper shows the potential for achieving low measurement uncertainties for Si-SPAD detector calibration even in the low photon flux range. The low uncertainties are only to be realized for reproducible measurement conditions, i.e. in specific for equal beam sizes and beam shapes and well as for an irradiation of equal active areas of the detector. This, however, will be difficult to obtain when measurements are performed at different national metrology institutes.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA