1.
JMIR Form Res ; 8: e52344, 2024 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-38640473

RESUMEN

BACKGROUND: Functional impairment is one of the most decisive prognostic factors in patients with complex chronic diseases. A more significant functional impairment indicates that the disease is progressing, which requires implementing diagnostic and therapeutic actions that stop the exacerbation of the disease. OBJECTIVE: This study aimed to predict alterations in the clinical condition of patients with complex chronic diseases by predicting the Barthel Index (BI), to assess their clinical and functional status using an artificial intelligence model and data collected through an internet of things mobility device. METHODS: A 2-phase pilot prospective single-center observational study was designed. During both phases, patients were recruited, and a wearable activity tracker was allocated to gather physical activity data. Patients were categorized into class A (BI≤20; total dependence), class B (2060; moderate or mild dependence, or independent). Data preprocessing and machine learning techniques were used to analyze mobility data. A decision tree was used to achieve a robust and interpretable model. To assess the quality of the predictions, several metrics including the mean absolute error, median absolute error, and root mean squared error were considered. Statistical analysis was performed using SPSS and Python for the machine learning modeling. RESULTS: Overall, 90 patients with complex chronic diseases were included: 50 during phase 1 (class A: n=10; class B: n=20; and class C: n=20) and 40 during phase 2 (class B: n=20 and class C: n=20). Most patients (n=85, 94%) had a caregiver. The mean value of the BI was 58.31 (SD 24.5). Concerning mobility aids, 60% (n=52) of patients required no aids, whereas the others required walkers (n=18, 20%), wheelchairs (n=15, 17%), canes (n=4, 7%), and crutches (n=1, 1%). Regarding clinical complexity, 85% (n=76) met patient with polypathology criteria with a mean of 2.7 (SD 1.25) categories, 69% (n=61) met the frailty criteria, and 21% (n=19) met the patients with complex chronic diseases criteria. The most characteristic symptoms were dyspnea (n=73, 82%), chronic pain (n=63, 70%), asthenia (n=62, 68%), and anxiety (n=41, 46%). Polypharmacy was presented in 87% (n=78) of patients. The most important variables for predicting the BI were identified as the maximum step count during evening and morning periods and the absence of a mobility device. The model exhibited consistency in the median prediction error with a median absolute error close to 5 in the training, validation, and production-like test sets. The model accuracy for identifying the BI class was 91%, 88%, and 90% in the training, validation, and test sets, respectively. CONCLUSIONS: Using commercially available mobility recording devices makes it possible to identify different mobility patterns and relate them to functional capacity in patients with polypathology according to the BI without using clinical parameters.

2.
Sci Rep ; 10(1): 2819, 2020 02 18.
Artículo en Inglés | MEDLINE | ID: mdl-32071319

RESUMEN

Intraoperative Neurophysiological Monitoring is a set of monitoring techniques consisting of reading electrical activity generated by the nervous system structures during surgeries. In order to guarantee signal quality, contact impedance between the sensing electrodes and the patient's skin needs to be as low as possible. Hence, monitoring this impedance while signals are measured is an important feature of current medical devices. The most commonly used technique involves injection of a known current and measurement of the voltage drop in the contact interface. This method poses several problems, such as power consumption (critical in battery-powered systems), frequency dependency and regulation issues, which are overcome by using a passive method. The fundamentals of the method proposed in this paper are based on the utilization of the variation suffered by the input random signal when a known resistance is connected in parallel to the input terminals of the low-noise amplifier (LNA) of the analog front-end of the acquisition system. Controlling the connection of the resistors and computing the root mean square of the LNA output voltage has been proved to be a useful tool to assess that the contact impedance is suitably low, allowing the user to know if the neural measurements obtained are valid.


Asunto(s)
Impedancia Eléctrica , Diseño de Equipo , Monitorización Neurofisiológica Intraoperatoria/instrumentación , Piel , Amplificadores Electrónicos , Electrodos , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA