Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
J Arthroplasty ; 39(9): 2336-2340, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38640965

RESUMEN

BACKGROUND: Megaprostheses contain many more modular components than conventional total hip and knee arthroplasty, which may lead to higher serum levels of metal ions. The aim of this study was to determine serum concentrations of titanium, chromium, and cobalt ions in cancer patients after limb salvage surgery with a megaprosthesis. METHODS: A retrospective, descriptive cohort analysis consisting of patients who underwent cancer-related limb salvage surgery with a megaprosthesis at our hospital between 2010 and 2020 was conducted. Baseline and follow-up data were extracted from clinical and surgical records. Blood samples were prospectively obtained. Descriptive statistics were used for the analysis. RESULTS: A total of 71 patients underwent limb salvage surgery during the study period. Of these, 22 (10 women, 12 men) were included in the study. The mean age was 52 years (range, 21 to 80). Most cases (n = 16; 72.7%) involved the femur. Most patients (n = 14, 63.6%) underwent total knee megaprosthesis surgery. Implant revision surgery was required in 45% of cases (n = 10), with a mean interval of 4.32 years between the initial and revision surgeries. The mean follow-up time after revision surgery was 4.05 years. High levels of chromium were observed in 22.7% of patients (n = 5). High cobalt levels were found in 68.2% (n = 15) of patients, with toxic levels in 9.1% (n = 2). Titanium levels were high in 77.3% (n = 17) of cases and toxic in 22.7% (n = 5). Postoperative chemotherapy was significantly associated with titanium levels (P = .017). No correlation was observed between metal ion levels and time from primary or revision surgery or time from the first to revision surgery. CONCLUSIONS: This study shows that cancer-related limb salvage surgery with megaprosthesis is associated with metal ion levels that exceed established safe thresholds. Compared to conventional hip arthroplasty, a higher proportion of the patients in this cohort presented elevated levels of metal ions. LEVEL OF EVIDENCE: III.


Asunto(s)
Cromo , Cobalto , Recuperación del Miembro , Reoperación , Titanio , Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Estudios Retrospectivos , Cobalto/sangre , Adulto , Titanio/sangre , Cromo/sangre , Reoperación/estadística & datos numéricos , Recuperación del Miembro/métodos , Anciano de 80 o más Años , Neoplasias/cirugía , Neoplasias/sangre , Adulto Joven , Prótesis de la Rodilla/efectos adversos
2.
JBJS Case Connect ; 12(3)2022 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-36040067

RESUMEN

CASE: Fractures of the femoral head are infrequent injuries with potentially devastating complications. Pipkin type II fractures often require surgical fixation. It involves intraarticular approaches that may increase the inherent morbidity of these fractures. Hip arthroscopy minimizes surgical aggression and allows for direct control of fracture reduction. We present a case report of an arthroscopic-assisted percutaneous fixation of a Pipkin-II femoral head fracture. A hip arthroscopy without traction and percutaneous screw fixation was conducted under arthroscopic and fluoroscopic guidance. CONCLUSION: Arthroscopic-assisted percutaneous fixation is a useful technique for optimal femoral head fracture treatment and may also minimize surgical morbidity and optimize early recovery.


Asunto(s)
Fracturas del Fémur , Cabeza Femoral , Artroscopía , Fracturas del Fémur/diagnóstico por imagen , Fracturas del Fémur/etiología , Fracturas del Fémur/cirugía , Cabeza Femoral/diagnóstico por imagen , Cabeza Femoral/lesiones , Cabeza Femoral/cirugía , Fijación Interna de Fracturas/métodos , Humanos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA