Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Magn Reson Imaging ; 2024 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-38733369

RESUMEN

BACKGROUND: Radiomics models trained on data from one center typically show a decline of performance when applied to data from external centers, hindering their introduction into large-scale clinical practice. Current expert recommendations suggest to use only reproducible radiomics features isolated by multiscanner test-retest experiments, which might help to overcome the problem of limited generalizability to external data. PURPOSE: To evaluate the influence of using only a subset of robust radiomics features, defined in a prior in vivo multi-MRI-scanner test-retest-study, on the performance and generalizability of radiomics models. STUDY TYPE: Retrospective. POPULATION: Patients with monoclonal plasma cell disorders. Training set (117 MRIs from center 1); internal test set (42 MRIs from center 1); external test set (143 MRIs from center 2-8). FIELD STRENGTH/SEQUENCE: 1.5T and 3.0T; T1-weighted turbo spin echo. ASSESSMENT: The task for the radiomics models was to predict plasma cell infiltration, determined by bone marrow biopsy, noninvasively from MRI. Radiomics machine learning models, including linear regressor, support vector regressor (SVR), and random forest regressor (RFR), were trained on data from center 1, using either all radiomics features, or using only reproducible radiomics features. Models were tested on an internal (center 1) and a multicentric external data set (center 2-8). STATISTICAL TESTS: Pearson correlation coefficient r and mean absolute error (MAE) between predicted and actual plasma cell infiltration. Fisher's z-transformation, Wilcoxon signed-rank test, Wilcoxon rank-sum test; significance level P < 0.05. RESULTS: When using only reproducible features compared with all features, the performance of the SVR on the external test set significantly improved (r = 0.43 vs. r = 0.18 and MAE = 22.6 vs. MAE = 28.2). For the RFR, the performance on the external test set deteriorated when using only reproducible instead of all radiomics features (r = 0.33 vs. r = 0.44, P = 0.29 and MAE = 21.9 vs. MAE = 20.5, P = 0.10). CONCLUSION: Using only reproducible radiomics features improves the external performance of some, but not all machine learning models, and did not automatically lead to an improvement of the external performance of the overall best radiomics model. TECHNICAL EFFICACY: Stage 2.

2.
Eur Radiol ; 33(2): 803-811, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35986773

RESUMEN

OBJECTIVES: Photon-counting detector computed tomography (PCD-CT) is a promising new technique for CT imaging. The aim of the present study was the in vitro comparison of coil-related artifacts in PCD-CT and conventional energy-integrating detector CT (EID-CT) using a comparable standard brain imaging protocol before and after metal artifact reduction (MAR). METHODS: A nidus-shaped rubber latex, resembling an aneurysm of the cerebral arteries, was filled with neurovascular platinum coils and inserted into a brain imaging phantom. Image acquisition and reconstruction were repeatedly performed for PCD-CT and EID-CT (n = 10, respectively) using a standard brain imaging protocol. Moreover, linear interpolation MAR was performed for PCD-CT and EID-CT images. The degree of artifacts was analyzed quantitatively (standard deviation in a donut-shaped region of interest) and qualitatively (5-point scale analysis). RESULTS: Quantitative and qualitative analysis demonstrated a lower degree of metal artifacts in the EID-CT images compared to the total-energy PCD-CT images (e.g., 82.99 ± 7.89 Hounsfield units (HU) versus 90.35 ± 6.28 HU; p < 0.001) with no qualitative difference between the high-energy bin PCD-CT images and the EID-CT images (4.18 ± 0.37 and 3.70 ± 0.64; p = 0.575). After MAR, artifacts were more profoundly reduced in the PCD-CT images compared to the EID-CT images in both analyses (e.g., 2.35 ± 0.43 and 3.18 ± 0.34; p < 0.001). CONCLUSION: PCD-CT in combination with MAR have the potential to provide an improved option for reduction of coil-related artifacts in cerebral imaging in this in vitro study. KEY POINTS: • Photon-counting detector CT produces more artifacts compared to energy-integrating detector CT without metal artifact reduction in cerebral in vitro imaging after neurovascular coil-embolization. • Spectral information of PCD-CT provides the potential for new post-processing techniques, since the coil-related artifacts were lower in PCD-CT images compared to EID-CT images after linear interpolation metal artifact reduction in this in vitro study.


Asunto(s)
Artefactos , Tomografía Computarizada por Rayos X , Humanos , Tomografía Computarizada por Rayos X/métodos , Encéfalo/diagnóstico por imagen , Fantasmas de Imagen , Fotones , Neuroimagen
3.
Eur Radiol ; 33(7): 4905-4914, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36809435

RESUMEN

OBJECTIVES: Radiomics image data analysis offers promising approaches in research but has not been implemented in clinical practice yet, partly due to the instability of many parameters. The aim of this study is to evaluate the stability of radiomics analysis on phantom scans with photon-counting detector CT (PCCT). METHODS: Photon-counting CT scans of organic phantoms consisting of 4 apples, kiwis, limes, and onions each were performed at 10 mAs, 50 mAs, and 100 mAs with 120-kV tube current. The phantoms were segmented semi-automatically and original radiomics parameters were extracted. This was followed by statistical analysis including concordance correlation coefficients (CCC), intraclass correlation coefficients (ICC), as well as random forest (RF) analysis, and cluster analysis to determine the stable and important parameters. RESULTS: Seventy-three of the 104 (70%) extracted features showed excellent stability with a CCC value > 0.9 when compared in a test and retest analysis, and 68 features (65.4%) were stable compared to the original in a rescan after repositioning. Between the test scans with different mAs values, 78 (75%) features were rated with excellent stability. Eight radiomics features were identified that had an ICC value greater than 0.75 in at least 3 of 4 groups when comparing the different phantoms in a phantom group. In addition, the RF analysis identified many features that are important for distinguishing the phantom groups. CONCLUSION: Radiomics analysis using PCCT data provides high feature stability on organic phantoms, which may facilitate the implementation of radiomics analysis likewise in clinical routine. KEY POINTS: • Radiomics analysis using photon-counting computed tomography provides high feature stability. • Photon-counting computed tomography may pave the way for implementation of radiomics analysis in clinical routine.


Asunto(s)
Bosques Aleatorios , Tomografía Computarizada por Rayos X , Humanos , Tomografía Computarizada por Rayos X/métodos , Fantasmas de Imagen , Procesamiento de Imagen Asistido por Computador/métodos , Fotones
4.
BMC Med Imaging ; 23(1): 97, 2023 07 26.
Artículo en Inglés | MEDLINE | ID: mdl-37495950

RESUMEN

BACKGROUND: Cardiovascular diseases remain the world's primary cause of death. The identification and treatment of patients at risk of cardiovascular events thus are as important as ever. Adipose tissue is a classic risk factor for cardiovascular diseases, has been linked to systemic inflammation, and is suspected to contribute to vascular calcification. To further investigate this issue, the use of texture analysis of adipose tissue using radiomics features could prove a feasible option. METHODS: In this retrospective single-center study, 55 patients (mean age 56, 34 male, 21 female) were scanned on a first-generation photon-counting CT. On axial unenhanced images, periaortic adipose tissue surrounding the thoracic descending aorta was segmented manually. For feature extraction, patients were divided into three groups, depending on coronary artery calcification (Agatston Score 0, Agatston Score 1-99, Agatston Score ≥ 100). 106 features were extracted using pyradiomics. R statistics was used for statistical analysis, calculating mean and standard deviation with Pearson correlation coefficient for feature correlation. Random Forest classification was carried out for feature selection and Boxplots and heatmaps were used for visualization. Additionally, monovariable logistic regression predicting an Agatston Score > 0 was performed, selected features were tested for multicollinearity and a 10-fold cross-validation investigated the stability of the leading feature. RESULTS: Two higher-order radiomics features, namely "glcm_ClusterProminence" and "glcm_ClusterTendency" were found to differ between patients without coronary artery calcification and those with coronary artery calcification (Agatston Score ≥ 100) through Random Forest classification. As the leading differentiating feature "glcm_ClusterProminence" was identified. CONCLUSION: Changes in periaortic adipose tissue texture seem to correlate with coronary artery calcium score, supporting a possible influence of inflammatory or fibrotic activity in perivascular adipose tissue. Radiomics features may potentially aid as corresponding biomarkers in the future.


Asunto(s)
Enfermedades Cardiovasculares , Enfermedad de la Arteria Coronaria , Humanos , Masculino , Femenino , Calcio , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen
5.
Stroke ; 50(10): 2799-2804, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31426729

RESUMEN

Background and Purpose- Large vessel occlusion stroke leads to highly variable hyperacute infarction growth. Our aim was to identify clinical and imaging parameters associated with hyperacute infarction growth in patients with an large vessel occlusion stroke of the anterior circulation. Methods- Seven hundred twenty-two consecutive patients with acute stroke were prospectively included in our monocentric stroke registry between 2009 and 2017. We selected all patients with a large vessel occlusion stroke of the anterior circulation, documented times from symptom onset, and CT perfusion on admission for our analysis (N=178). Ischemic core volume was determined with CT perfusion using automated thresholds. Hyperacute infarction growth was defined as ischemic core volume divided by times from symptom onset, assuming linear progression during times from symptom onset to imaging on admission. For collateral assessment, the regional leptomeningeal collateral score (rLMC) was used. Clinical data included the National Institutes of Health Stroke Scale score on admission and cardiovascular risk factors. Regression analysis was performed to adjust for confounders. Results- Median ischemic core volume was 34.4 mL, and median hyperacute infarction growth was 0.27 mL/min. In regression analysis including age, sex, National Institutes of Health Stroke Scale, clot burden score, diabetes mellitus, smoking, hypercholesteremia, hypertension, Alberta Stroke Program Early CT Score, and rLMC scores, only the rLMC score had a significant, independent association with hyperacute infarction growth (adjusted ß=-0.35; P<0.001). Trichotomizing patients by rLMC scores yielded 65 patients with good (rLMC >15), 67 with intermediate (rLMC 11-15) and 46 with poor collaterals (rLMC <11) with an infarction growth of 0.17 mL/min, 0.26 mL/min, and 0.41 mL/min, respectively. Conclusions- Hyperacute infarction growth strongly depends on collaterals. In primary stroke centers, hyperacute infarction growth may be extrapolated to estimate the stroke progression during transfer times to thrombectomy centers and to support decisions on which patients to transfer.


Asunto(s)
Infarto Cerebral/diagnóstico por imagen , Infarto Cerebral/patología , Circulación Colateral , Accidente Cerebrovascular/diagnóstico por imagen , Accidente Cerebrovascular/patología , Anciano , Anciano de 80 o más Años , Infarto Cerebral/etiología , Angiografía por Tomografía Computarizada/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Neuroimagen/métodos , Imagen de Perfusión/métodos , Accidente Cerebrovascular/complicaciones
6.
Radiology ; 291(2): 451-458, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30888935

RESUMEN

Background Recent studies have proven the effectiveness of thrombectomy up to 24 hours after stroke onset for patients with specific criteria at advanced CT or MRI. Clinical implementation of treatment in this extended time window remains a challenge, as many stroke centers do not routinely use advanced imaging. Purpose To determine whether automated cerebral x-ray attenuation measurements at noncontrast CT provide information on the presence of CT perfusion-defined ischemic core as applied in late time windows for thrombectomy. Materials and Methods In this retrospective study, patients with middle cerebral artery stroke due to proximal occlusion from 2009 to 2017 were included. All patients underwent noncontrast CT and CT perfusion. Automated software was used to calculate relative Hounsfield unit (rHU) values for Alberta Stroke Program Early CT Score (ASPECTS) regions on noncontrast CT images as the ratio of x-ray attenuation between ischemic versus non-ischemic hemispheres. Sensitivity, specificity, and diagnostic performance of rHU and composite rHU-ASPECTS, a score incorporating rHU from all regions, were analyzed for the classification of regional ischemic core and late time window thrombectomy criteria at CT perfusion. Results Data in a total of 200 patients were evaluated (105 women [mean age, 74 years ± 14 {standard deviation}] and 95 men [mean age, 76 years ± 14]). There were 121 patients in the validation cohort and 79 patients in the independent test cohort. Compared among all examined regions, rHU values yielded the best classification of ischemic core for the caudate nucleus, the lentiform nucleus, and the insula (with areas under the receiver operating characteristic curve [AUCs] ranging from 0.70 to 0.77; P < .001 for each). The composite rHU-ASPECTS score allowed classification of CT perfusion imaging selection criteria of ischemic core sizes of less than 70 mL and target mismatch of greater than 1.8 with AUCs of 0.80 (P = .001; 75% sensitivity and 83% specificity) in the test cohort and 0.74 (P < .001; 58% sensitivity and 82% specificity) in the validation cohort. Conclusion Noncontrast CT x-ray attenuation measurements identify Alberta Stroke Program Early CT Score regions classified as ischemic core at CT perfusion. This approach may serve as a selection criteria surrogate for thrombectomy in late time windows. © RSNA, 2019 Online supplemental material is available for this article.


Asunto(s)
Isquemia Encefálica/diagnóstico por imagen , Imagen de Perfusión/métodos , Tomografía Computarizada por Rayos X/métodos , Anciano , Anciano de 80 o más Años , Encéfalo/diagnóstico por imagen , Encéfalo/patología , Isquemia Encefálica/patología , Angiografía por Tomografía Computarizada , Femenino , Humanos , Infarto de la Arteria Cerebral Media/diagnóstico por imagen , Infarto de la Arteria Cerebral Media/patología , Masculino , Persona de Mediana Edad , Curva ROC , Estudios Retrospectivos , Trombectomía
7.
J Stroke Cerebrovasc Dis ; 28(1): 227-228, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30314761

RESUMEN

BACKGROUND: Anton's syndrome is a rare neurological disorder characterized by a combination of visual anosognosia and confabulation of visual experience, most often seen after bilateral ischemic damage to the posterior occipital cortex. CASE REPORT: We report the first case of an acute synchronous P2 occlusion as confirmed by multiparametric computed tomography (CT) including perfusion. After the administration of Recombinant tissue plasminogen activator (rtPA), Anton's syndrome completely resolved. CONCLUSION: Multiparametric CT imaging may aid in quickly proving the underlying stroke in Anton's syndrome, especially helpful considering the discrepancy between the patient's perception and clinical examination results.


Asunto(s)
Ceguera Cortical/tratamiento farmacológico , Ceguera Cortical/etiología , Accidente Cerebrovascular/complicaciones , Accidente Cerebrovascular/tratamiento farmacológico , Terapia Trombolítica , Administración Intravenosa , Anciano de 80 o más Años , Ceguera Cortical/diagnóstico por imagen , Diagnóstico Diferencial , Femenino , Fibrinolíticos/administración & dosificación , Humanos , Lóbulo Occipital/diagnóstico por imagen , Accidente Cerebrovascular/diagnóstico por imagen , Activador de Tejido Plasminógeno/administración & dosificación
8.
Int J Cardiovasc Imaging ; 39(5): 1065-1073, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36773035

RESUMEN

Coronary computed tomography angiography has become a mainstay in diagnosing coronary artery disease and is increasingly used in screening symptomatic patients. Recently, photon-counting computed tomography (PCCT) has been introduced into clinical practice, offering higher spatial and temporal resolution. As the applied radiation dose is highly dependent on the choice of scan mode and is lowest using the ultra-fast high-pitch (FLASH) mode, guidelines for their application are needed. From a retrospective study investigating the properties of a novel photon-counting computed tomography, all patients who underwent FLASH-mode PCCT angiography were selected between January and April 2022. This resulted in a study population of 46 men and 27 women. We recorded pre- and intrascan ECG readings and calculated heart rate (maximum heart rate 73 bpm) as well heart rate variability (maximum HRV 37 bpm) as measured by the standard deviation of the heart rate. Diagnostic quality and motion artifacts scores were recorded for each coronary artery segment by consensus between two readers. We found a highly significant association between heart rate variability and image quality (p < 0.001). The heart rate itself was not independently associated with image quality. Both heart rate and heart rate variability were significantly associated with the presence of motion artifacts in a combined model. Scan heart rate variability-but not heart rate itself-is a highly significant predictor of reduced image quality on high-pitch coronary photon-counting computed tomography angiography. This may be due to better scanner architecture and an increased temporal resolution compared to conventional energy-integrating detector computed tomography, which has to be addressed in a comparison study in the future.


Asunto(s)
Angiografía por Tomografía Computarizada , Masculino , Humanos , Femenino , Frecuencia Cardíaca , Estudios Retrospectivos , Estudios de Factibilidad , Valor Predictivo de las Pruebas , Angiografía Coronaria/métodos , Dosis de Radiación
9.
Cancer Imaging ; 23(1): 95, 2023 Oct 05.
Artículo en Inglés | MEDLINE | ID: mdl-37798797

RESUMEN

OBJECTIVES: The goal of this study is to demonstrate the performance of radiomics and CNN-based classifiers in determining the primary origin of gastrointestinal liver metastases for visually indistinguishable lesions. METHODS: In this retrospective, IRB-approved study, 31 pancreatic cancer patients with 861 lesions (median age [IQR]: 65.39 [56.87, 75.08], 48.4% male) and 47 colorectal cancer patients with 435 lesions (median age [IQR]: 65.79 [56.99, 74.62], 63.8% male) were enrolled. A pretrained nnU-Net performed automated segmentation of 1296 liver lesions. Radiomics features for each lesion were extracted using pyradiomics. The performance of several radiomics-based machine-learning classifiers was investigated for the lesions and compared to an image-based deep-learning approach using a DenseNet-121. The performance was evaluated by AUC/ROC analysis. RESULTS: The radiomics-based K-nearest neighbor classifier showed the best performance on an independent test set with AUC values of 0.87 and an accuracy of 0.67. In comparison, the image-based DenseNet-121-classifier reached an AUC of 0.80 and an accuracy of 0.83. CONCLUSIONS: CT-based radiomics and deep learning can distinguish the etiology of liver metastases from gastrointestinal primary tumors. Compared to deep learning, radiomics based models showed a varying generalizability in distinguishing liver metastases from colorectal cancer and pancreatic adenocarcinoma.


Asunto(s)
Adenocarcinoma , Neoplasias Colorrectales , Aprendizaje Profundo , Neoplasias Hepáticas , Neoplasias Pancreáticas , Humanos , Masculino , Femenino , Estudios Retrospectivos , Neoplasias Pancreáticas/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Pancreáticas
10.
Invest Radiol ; 58(4): 253-264, 2023 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-36165988

RESUMEN

OBJECTIVES: Despite the extensive number of publications in the field of radiomics, radiomics algorithms barely enter large-scale clinical application. Supposedly, the low external generalizability of radiomics models is one of the main reasons, which hinders the translation from research to clinical application. The objectives of this study were to investigate reproducibility of radiomics features (RFs) in vivo under variation of patient positioning, magnetic resonance imaging (MRI) sequence, and MRI scanners, and to identify a subgroup of RFs that shows acceptable reproducibility across all different acquisition scenarios. MATERIALS AND METHODS: Between November 30, 2020 and February 16, 2021, 55 patients with monoclonal plasma cell disorders were included in this prospective, bi-institutional, single-vendor study. Participants underwent one reference scan at a 1.5 T MRI scanner and several retest scans: once after simple repositioning, once with a second MRI protocol, once at another 1.5 T scanner, and once at a 3 T scanner. Radiomics feature from the bone marrow of the left hip bone were extracted, both from original scans and after different image normalizations. Intraclass correlation coefficient (ICC) was used to assess RF repeatability and reproducibility. RESULTS: Fifty-five participants (mean age, 59 ± 7 years; 36 men) were enrolled. For T1-weighted images after muscle normalization, in the simple test-retest experiment, 110 (37%) of 295 RFs showed an ICC ≥0.8: 54 (61%) of 89 first-order features (FOFs), 35 (95%) of 37 volume and shape features, and 21 (12%) of 169 texture features (TFs). When the retest was performed with different technical settings, even after muscle normalization, the number of FOF/TF with an ICC ≥0.8 declined to 58/13 for the second protocol, 29/7 for the second 1.5 T scanner, and 49/7 for the 3 T scanner, respectively. Twenty-five (28%) of the 89 FOFs and 6 (4%) of the 169 TFs from muscle-normalized T1-weighted images showed an ICC ≥0.8 throughout all repeatability and reproducibility experiments. CONCLUSIONS: In vivo, only few RFs are reproducible with different MRI sequences or different MRI scanners, even after application of a simple image normalization. Radiomics features selected by a repeatability experiment only are not necessarily suited to build radiomics models for multicenter clinical application. This study isolated a subset of RFs, which are robust to variations in MRI acquisition observed in scanners from 1 vendor, and therefore are candidates to build reproducible radiomics models for monoclonal plasma cell disorders for multicentric applications, at least when centers are equipped with scanners from this vendor.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Células Plasmáticas , Masculino , Humanos , Persona de Mediana Edad , Anciano , Estudios Prospectivos , Reproducibilidad de los Resultados , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos
11.
Front Neurol ; 14: 1320620, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38225983

RESUMEN

Background and purpose: Automated perfusion imaging can detect stroke patients with unknown time of symptom onset who are eligible for thrombolysis. However, the availability of this technique is limited. We, therefore, established the novel concept of computed tomography (CT) hypoperfusion-hypodensity mismatch, i.e., an ischemic core lesion visible on cerebral perfusion CT without visible hypodensity in the corresponding native cerebral CT. We compared both methods regarding their accuracy in identifying patients suitable for thrombolysis. Methods: In a retrospective analysis of the MissPerfeCT observational cohort study, patients were classified as suitable or not for thrombolysis based on established time window and imaging criteria. We calculated predictive values for hypoperfusion-hypodensity mismatch and automated perfusion imaging to compare accuracy in the identification of patients suitable for thrombolysis. Results: Of 247 patients, 219 (88.7%) were eligible for thrombolysis and 28 (11.3%) were not eligible for thrombolysis. Of 197 patients who were within 4.5 h of symptom onset, 190 (96.4%) were identified by hypoperfusion-hypodensity mismatch and 88 (44.7%) by automated perfusion mismatch (p < 0.001). Of 22 patients who were beyond 4.5 h of symptom onset but were eligible for thrombolysis, 5 patients (22.7%) were identified by hypoperfusion-hypodensity mismatch. Predictive values for the hypoperfusion-hypodensity mismatch vs. automated perfusion mismatch were as follows: sensitivity, 89.0% vs. 50.2%; specificity, 71.4% vs. 100.0%; positive predictive value, 96.1% vs. 100.0%; and negative predictive value, 45.5% vs. 20.4%. Conclusion: The novel method of hypoperfusion-hypodensity mismatch can identify patients suitable for thrombolysis with higher sensitivity and lower specificity than established techniques. Using this simple method might therefore increase the proportion of patients treated with thrombolysis without the use of special automated software.The MissPerfeCT study is a retrospective observational multicenter cohort study and is registered with clinicaltrials.gov (NCT04277728).

12.
Invest Radiol ; 58(10): 754-765, 2023 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-37222527

RESUMEN

OBJECTIVES: In multiple myeloma and its precursor stages, plasma cell infiltration (PCI) and cytogenetic aberrations are important for staging, risk stratification, and response assessment. However, invasive bone marrow (BM) biopsies cannot be performed frequently and multifocally to assess the spatially heterogenous tumor tissue. Therefore, the goal of this study was to establish an automated framework to predict local BM biopsy results from magnetic resonance imaging (MRI). MATERIALS AND METHODS: This retrospective multicentric study used data from center 1 for algorithm training and internal testing, and data from center 2 to 8 for external testing. An nnU-Net was trained for automated segmentation of pelvic BM from T1-weighted whole-body MRI. Radiomics features were extracted from these segmentations, and random forest models were trained to predict PCI and the presence or absence of cytogenetic aberrations. Pearson correlation coefficient and the area under the receiver operating characteristic were used to evaluate the prediction performance for PCI and cytogenetic aberrations, respectively. RESULTS: A total of 672 MRIs from 512 patients (median age, 61 years; interquartile range, 53-67 years; 307 men) from 8 centers and 370 corresponding BM biopsies were included. The predicted PCI from the best model was significantly correlated ( P ≤ 0.01) to the actual PCI from biopsy in all internal and external test sets (internal test set: r = 0.71 [0.51, 0.83]; center 2, high-quality test set: r = 0.45 [0.12, 0.69]; center 2, other test set: r = 0.30 [0.07, 0.49]; multicenter test set: r = 0.57 [0.30, 0.76]). The areas under the receiver operating characteristic of the prediction models for the different cytogenetic aberrations ranged from 0.57 to 0.76 for the internal test set, but no model generalized well to all 3 external test sets. CONCLUSIONS: The automated image analysis framework established in this study allows for noninvasive prediction of a surrogate parameter for PCI, which is significantly correlated to the actual PCI from BM biopsy.


Asunto(s)
Aprendizaje Profundo , Mieloma Múltiple , Masculino , Humanos , Persona de Mediana Edad , Mieloma Múltiple/diagnóstico por imagen , Mieloma Múltiple/genética , Médula Ósea/diagnóstico por imagen , Estudios Retrospectivos , Imagen por Resonancia Magnética/métodos , Biopsia , Aberraciones Cromosómicas
13.
Radiologie (Heidelb) ; 62(6): 504-510, 2022 Jun.
Artículo en Alemán | MEDLINE | ID: mdl-35925058

RESUMEN

BACKGROUND: Since its introduction, spectral computed tomography has become an integral part of clinical imaging with a variety of possible applications. Over time, technical innovations have considerably improved the spatial and energy resolution. The recent introduction of computed tomographs utilizing photon-counting x­ray detectors has opened up further applications, which need to be investigated regarding their clinical utility. OBJECTIVES: This article gives an overview of the development of spectral computed tomography in general and photon-counting computed tomography in particular, with a special focus on recent technical developments and their clinical applications. CONCLUSION: Very likely, photon-counting X­ray detectors will over time prevail over conventional energy-integrating detectors. Most technical problems hindering clinical use have been overcome, so that the unquestionable advantages outweigh the remaining disadvantages. Further developments especially of detector electronics, reconstruction algorithms and software-based postprocessing will further support its clinical introduction.


Asunto(s)
Fotones , Tomografía Computarizada por Rayos X , Algoritmos , Radiografía , Tomografía Computarizada por Rayos X/métodos , Rayos X
14.
Med Phys ; 49(9): 5981-5992, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35638106

RESUMEN

PURPOSE: Magnetic resonance imaging (MRI) of the lung can be used for diagnosis and monitoring of interstitial lung disease. Biophysical models of alveolar lung tissue are needed to understand the complex interplay of susceptibility, diffusion, and flow effects, and their influence on magnetic resonance (MR) spin dephasing. METHODS: In this work, we present a method for modeling the signal decay of lung tissue by utilizing a two-compartment model, which considers the different spin dephasing mechanisms in the alveolar vasculature and interstitial tissue. This allows calculating the magnetization dynamics and the MR lineshape, which can be measured noninvasively using clinical MR scanners. RESULTS: The accuracy of the method was evaluated using finite element simulations and the experimentally measured lineshapes of a healthy volunteer. In this comparison, the model performs well, indicating that the relevant spin dephasing mechanisms are correctly taken into account. CONCLUSIONS: The proposed method can be used to estimate the influence of blood flow and alveolar geometry on the MR lineshape of lung tissue.


Asunto(s)
Pulmón , Imagen por Resonancia Magnética , Difusión , Humanos , Pulmón/diagnóstico por imagen , Espectroscopía de Resonancia Magnética
15.
Diagnostics (Basel) ; 12(5)2022 May 23.
Artículo en Inglés | MEDLINE | ID: mdl-35626448

RESUMEN

The implementation of radiomics-based, quantitative imaging parameters is hampered by a lack of stability and standardization. Photon-counting computed tomography (PCCT), compared to energy-integrating computed tomography (EICT), does rely on a novel detector technology, promising better spatial resolution and contrast-to-noise ratio. However, its effect on radiomics feature properties is unknown. This work investigates this topic in myocardial imaging. In this retrospective, single-center IRB-approved study, the left ventricular myocardium was segmented on CT, and the radiomics features were extracted using pyradiomics. To compare features between scanners, a t-test for non-paired samples and F-test was performed, with a threshold of 0.05 set as a benchmark for significance. Feature correlations were calculated by the Pearson correlation coefficient, and visualization was performed with heatmaps. A total of 50 patients (56% male, mean age 56) were enrolled in this study, with equal proportions of PCCT and EICT. First-order features were, nearly, comparable between both groups. However, higher-order features showed a partially significant difference between PCCT and EICT. While first-order radiomics features of left ventricular myocardium show comparability between PCCT and EICT, detected differences of higher-order features may indicate a possible impact of improved spatial resolution, better detection of lower-energy photons, and a better signal-to-noise ratio on texture analysis on PCCT.

16.
Diagnostics (Basel) ; 12(7)2022 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-35885567

RESUMEN

The coronary artery calcium score is an independent risk factor of the development of adverse cardiac events. The severity of coronary artery calcification may influence the myocardial texture. Due to higher spatial resolution and signal-to-noise ratio, new CT technologies such as PCCT may improve the detection of texture alterations depending on the severity of coronary artery calcification. In this retrospective, single-center, IRB-approved study, left ventricular myocardium was segmented and radiomics features were extracted using pyradiomics. The mean and standard deviation with the Pearson correlation coefficient for correlations of features were calculated and visualized as boxplots and heatmaps. Random forest feature selection was performed. Thirty patients (26.7% women, median age 58 years) were enrolled in the study. Patients were divided into two subgroups depending on the severity of coronary artery calcification (Agatston score 0 and Agatston score ≥ 100). Through random forest feature selection, a set of four higher-order features could be defined to discriminate myocardial texture between the two groups. When including the additional Agatston 1-99 groups as a validation, a severity-associated change in feature intensity was detected. A subset of radiomics features texture alterations of the left ventricular myocardium was associated with the severity of coronary artery calcification estimated by the Agatston score.

17.
Rofo ; 194(9): 975-982, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35211930

RESUMEN

BACKGROUND: Perfusion MRI is a well-established imaging modality with a multitude of applications in oncological and cardiovascular imaging. Clinically used processing methods, while stable and robust, have remained largely unchanged in recent years. Despite promising results from novel methods, their relatively minimal improvement compared to established methods did not generally warrant significant changes to clinical perfusion processing. RESULTS AND CONCLUSION: Machine learning in general and deep learning in particular, which are currently revolutionizing computer-aided diagnosis, may carry the potential to change this situation and truly capture the potential of perfusion imaging. Recent advances in the training of recurrent neural networks make it possible to predict and classify time series data with high accuracy. Combining physics-based tissue models and deep learning, using either physics-informed neural networks or universal differential equations, simplifies the training process and increases the interpretability of the resulting models. Due to their versatility, these methods will potentially be useful in bridging the gap between microvascular architecture and perfusion parameters, akin to MR fingerprinting in structural MR imaging. Still, further research is urgently needed before these methods may be used in clinical practice. KEY POINTS: · Machine learning offers promising methods for processing of perfusion data.. · Recurrent neural networks can classify time series with high accuracy.. · Data augmentation is essentially especially when using small datasets.. CITATION FORMAT: · Rotkopf LT, Zhang KS, Tavakoli AA et al. Quantitative Analysis of DCE and DSC-MRI: From Kinetic Modeling to Deep Learning. Fortschr Röntgenstr 2022; 194: 975 - 982.


Asunto(s)
Aprendizaje Profundo , Procesamiento de Imagen Asistido por Computador , Aprendizaje Automático , Angiografía por Resonancia Magnética , Imagen por Resonancia Magnética , Redes Neurales de la Computación
18.
Sci Rep ; 12(1): 19594, 2022 11 15.
Artículo en Inglés | MEDLINE | ID: mdl-36379992

RESUMEN

Feature stability and standardization remain challenges that impede the clinical implementation of radiomics. This study investigates the potential of spectral reconstructions from photon-counting computed tomography (PCCT) regarding organ-specific radiomics feature stability. Abdominal portal-venous phase PCCT scans of 10 patients in virtual monoenergetic (VM) (keV 40-120 in steps of 10), polyenergetic, virtual non-contrast (VNC), and iodine maps were acquired. Two 2D and 3D segmentations measuring 1 and 2 cm in diameter of the liver, lung, spleen, psoas muscle, subcutaneous fat, and air were obtained for spectral reconstructions. Radiomics features were extracted with pyradiomics. The calculation of feature-specific intraclass correlation coefficients (ICC) was performed by comparing all segmentation approaches and organs. Feature-wise and organ-wise correlations were evaluated. Segmentation-resegmentation stability was evaluated by concordance correlation coefficient (CCC). Compared to non-VM, VM-reconstruction features tended to be more stable. For VM reconstructions, 3D 2 cm segmentation showed the highest average ICC with 0.63. Based on a criterion of ≥ 3 stable organs and an ICC of ≥ 0.75, 12-mainly non-first-order features-are shown to be stable between the VM reconstructions. In a segmentation-resegmentation analysis in 3D 2 cm, three features were identified as stable based on a CCC of > 0.6 in ≥ 3 organs in ≥ 6 VM reconstructions. Certain radiomics features vary between monoenergetic reconstructions and depend on the ROI size. Feature stability was also shown to differ between different organs. Yet, glcm_JointEntropy, gldm_GrayLevelNonUniformity, and firstorder_Entropy could be identified as features that could be interpreted as energy-independent and segmentation-resegmentation stable in this PCCT collective. PCCT may support radiomics feature standardization and comparability between sites.


Asunto(s)
Yodo , Tomografía Computarizada por Rayos X , Humanos , Tomografía Computarizada por Rayos X/métodos
19.
Int J Cardiovasc Imaging ; 38(11): 2459-2467, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36434338

RESUMEN

Perivascular adipose tissue is known to be metabolically active. Volume and density of periaortic adipose tissue are associated with aortic calcification as well as aortic diameter indicating a possible influence of periaortic adipose tissue on the development of aortic calcification. Due to better spatial resolution and signal-to-noise ratio, new CT technologies such as photon-counting computed tomography may allow the detection of texture alterations of periaortic adipose tissue depending on the existence of local aortic calcification possibly outlining a biomarker for the development of arteriosclerosis. In this retrospective, single-center, IRB-approved study, periaortic adipose tissue was segmented semiautomatically and radiomics features were extracted using pyradiomics. Statistical analysis was performed in R statistics calculating mean and standard deviation with Pearson correlation coefficient for feature correlation. For feature selection Random Forest classification was performed. A two-tailed unpaired t test was applied to the final feature set. Results were visualized as boxplots and heatmaps. A total of 30 patients (66.6% female, median age 57 years) were enrolled in this study. Patients were divided into two subgroups depending on the presence of local aortic calcification. By Random Forest feature selection a set of seven higher-order features could be defined to discriminate periaortic adipose tissue texture between these two groups. The t test showed a statistic significant discrimination for all features (p < 0.05). Texture changes of periaortic adipose tissue associated with the existence of local aortic calcification may lay the foundation for finding a biomarker for development of arteriosclerosis.


Asunto(s)
Tejido Adiposo , Arteriosclerosis , Humanos , Femenino , Persona de Mediana Edad , Masculino , Estudios Retrospectivos , Valor Predictivo de las Pruebas , Tejido Adiposo/diagnóstico por imagen , Tomografía Computarizada por Rayos X
20.
J Stroke ; 24(3): 390-395, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36221942

RESUMEN

BACKGROUND AND PURPOSE: Many patients with stroke cannot receive intravenous thrombolysis because the time of symptom onset is unknown. We tested whether a simple method of computed tomography (CT)-based quantification of water uptake in the ischemic tissue can identify patients with stroke onset within 4.5 hours. METHODS: This retrospective analysis of the MissPerfeCT study (August 2009 to November 2017) includes consecutive patients with known onset of symptoms from seven tertiary stroke centers. We developed a simplified algorithm based on region of interest (ROI) measurements to quantify water uptake of the ischemic lesion and thereby quantify time of symptom onset within and beyond 4.5 hours. Perfusion CT was used to identify ischemic brain tissue, and its density was measured in non-contrast CT and related to the density of the corresponding area of the contralateral hemisphere to quantify lesion water uptake. RESULTS: Of 263 patients, 204 (77.6%) had CT within 4.5 hours. Water uptake was significantly lower in patients with stroke onset within (6.7%; 95% confidence interval [CI], 6.0% to 7.4%) compared to beyond 4.5 hours (12.7%; 95% CI, 10.7% to 14.7%). The area under the curve for distinguishing these patient groups according to percentage water uptake was 0.744 with an optimal cut-off value of 9.5%. According to this cut-off the positive predictive value was 88.8%, sensitivity was 73.5%, specificity 67.8%, negative predictive value was 42.6%. CONCLUSIONS: Ischemic stroke patients with unknown time of symptom onset can be identified as being within a timeframe of 4.5 hours using a ROI-based method to assess water uptake on admission non-contrast head CT.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA