1.
Graefes Arch Clin Exp Ophthalmol ; 254(1): 169-75, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26174969

RESUMEN

PURPOSE: The purpose of this study was to evaluate intra-session repeatability of measurements of the iridocorneal angle at different meridians in the nasal and temporal areas in healthy eyes using the Sirius Scheimpflug photography-based system in glaucoma analysis mode. METHODS: A total of 43 eyes of 43 patients ranging in age from 36 to 79 years were enrolled in the study. All eyes received a comprehensive ophthalmologic examination including a complete anterior segment analysis with the Costruzione Strumenti Oftalmici [CSO] Sirius system. Three consecutive measurements of nasal and temporal angles at 0°, ±10°, ±20°, and ±30° meridians were obtained in order to assess the intra-session repeatability of iridocorneal angle measurements provided by the device using the glaucoma analysis mode. Within-subject standard deviation (Sw), coefficient of variation (CV), and intraclass correlation coefficient (ICC) values were calculated. RESULTS: The mean Sw was 1.07 ± 1.09°, 1.22 ± 1.53°, 0.66 ± 0.51°, 0.86 ± 0.57°, 0.68 ± 0.65°, 0.84 ± 0.68°, and 0.91 ± 0.70° at the temporal 30°, 20°, 10°, 0°, -10°, -20°, and -30° positions, respectively. Mean Sw was 3.13 ± 3.15°, 3.43 ± 3.63°, 2.75 ± 2.29°, 2.19 ± 1.55°, 1.90 ± 1.49°, 2.14 ± 1.74°, and 2.24 ± 2.06° at the temporal -30°, -20°, -10°, 0°, 10°, 20°, and 30° positions, respectively. Mean CV ranged from 1.36 ± 1.05 % (nasal 0° position) to 10.92 ± 13.95 % (nasal -20° position). ICC values ranged from 0.778 to 0.972. CONCLUSIONS: The glaucoma analysis mode of the Sirius system provides consistent measurements of the iridocorneal angle at different meridians in healthy eyes, with slightly less consistency for nasal measurements. It may be considered a clinically useful non-invasive technique for the detection of potentially occludable angles.


Asunto(s)
Córnea/anatomía & histología , Iris/anatomía & histología , Fotograbar/métodos , Adolescente , Adulto , Anciano , Cámara Anterior/anatomía & histología , Topografía de la Córnea/instrumentación , Femenino , Voluntarios Sanos , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados
2.
Clin Exp Optom ; 101(2): 200-205, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29090488

RESUMEN

PURPOSE: To evaluate the intra-session repeatability of keratometric measurements obtained in healthy eyes with the Verion image-guided system (Alcon Laboratories Inc, Fort Worth, Texas, USA) as well as the interchangeability of such measurements with those obtained with an optical biometer (Aladdin, Topcon, Tokyo, Japan). METHODS: A total of 53 eyes of 53 patients (age 31-67 years) were enrolled in the study. All eyes received a comprehensive ophthalmologic examination including an analysis with the Verion image-guided and Aladdin systems. Three consecutive measurements of keratometry were obtained with the Verion system to assess the intra-session repeatability. Within-subject standard deviation (Sw ) and intraobserver precision (± 1.96 × Sw ) were calculated. Bland-Altman analysis was used for the interchangeability analysis. RESULTS: Mean Sw was 0.26, 0.24 and 0.10 D for the keratometric power in the flattest meridian (K1), keratometric power in the steepest meridian (K2) and astigmatism, respectively. Mean Sw was 4.29° for the axis of the flattest corneal meridian (AX1). Statistically significant but clinically acceptable differences were found in K1, K2 and keratometric astigmatism among systems (p < 0.01). In contrast, differences among systems in AX1 were not statistically significant (p = 0.385) but clinically relevant (mean difference: 15.74°; limits of agreement: -30.93 to 62.41°). CONCLUSIONS: The Verion system provides consistent measurements of keratometric parameters, with measurements of AX1 that are not interchangeable with that provided by the optical biometer Aladdin, especially in cases of low and oblique astigmatism.


Asunto(s)
Astigmatismo/diagnóstico , Córnea/patología , Técnicas de Diagnóstico Oftalmológico/instrumentación , Adulto , Anciano , Biometría/instrumentación , Femenino , Voluntarios Sanos , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Estudios Prospectivos , Refracción Ocular/fisiología , Reproducibilidad de los Resultados , Agudeza Visual/fisiología