Clin Res Cardiol ; 110(12): 1993-2006, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34505192

RESUMEN

BACKGROUND: Bicuspid aortic valve may be associated with increased complications during transcatheter aortic valve implantation (TAVI). AIMS: Compare balloon-expandable transcatheter heart valve (THV) safety and efficacy in severe tricuspid (TAV) and bicuspid (BAV) aortic stenosis. METHODS: Transfemoral TAVI was performed in 743 patients (Jan 2014-June 2019) using the SAPIEN 3 THV. Aortic valve morphology was determined using computed tomography. Valve Academic Research Consortium-2 (VARC-2) derived safety and efficacy endpoints at 1 year were evaluated. RESULTS: BAV patients (n = 78), were younger (77 [72, 81] vs. 81 [78, 85] years, p < 0.001) with lower surgical risk (EuroSCORE II 2.96% vs. 4.51% p < 0.001). Bicuspid valves were more calcified (BAV 1308mm3, TAV 848mm3 p < 0.001) with more asymmetric calcification (BAV 63/78 (81%), TAV 239/665 (36%), p < 0.001). Device success (BAV 94%, TAV 90%, p = 0.45) and major vascular complications (BAV 6%, TAV 9%, p = 0.66) were comparable. At 1 year, there was a trend toward lower combined all-cause mortality and rehospitalization for congestive heart failure in BAV patients (BAV 7%, TAV 13%, p = 0.08) with significantly lower all-cause mortality in this cohort (BAV 1%, TAV 9%, p = 0.020). VARC-2 time-related valve safety (BAV 22%, TAV 20%, p = 0.60) was comparable; however, bioprosthetic valve thrombosis remained more common in BAV patients (BAV 7%, TAV 2%, p = 0.010, Hazard ratio 3.57 [95% confidence interval 1.26, 10.10]). After propensity score matching, only bioprosthetic valve thrombosis remained significantly different. CONCLUSIONS: Safety and efficacy of the SAPIEN 3 balloon-expandable THV in BAV is comparable with TAV. Higher rates of bioprosthetic valve thrombosis require further investigation.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Tricúspide/cirugía , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico , Femenino , Estudios de Seguimiento , Humanos , Masculino , Tomografía Computarizada Multidetector/métodos , Diseño de Prótesis , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA