J Endovasc Ther ; 30(5): 769-778, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-35543452

RESUMEN

PURPOSE: Physician-modified stent-grafts (PMSG) are widely used, especially when a patient's condition precludes waiting for a custom-made device. In recent years, the modification process has been upgraded using 3-dimensional (3D) aortic templates. Nonetheless, the reliability of PMSG and accuracy of fenestration alignment with the target vessel are not known. Thus, the study is aimed to fulfill the gap in current knowledge. MATERIALS AND METHODS: Ten computed tomographic (CT) scans of aortic aneurysm previously treated with the fenestrated endovascular repair were selected to 3D-print aortic templates and elastic vessel phantoms. Two vascular surgeons performed fenestrations using the 3D template and modification plan based on CT measurements. Two operators each performed 10 fenestrated stent-grafts in the aortic template and 10 using CT measurements, for a total of 40 fenestrated stent-grafts. Then, stent-grafts were implanted in elastic vessel phantoms, which served to evaluate fenestration alignment with the target vessel. The alignment was judged in a 5-point scale: 0%, 1% to 25%, 26% to 50%, 51% to 75%, and 76% to 100%. The distances between fenestrations served to calculate interobserver variability for both methods. The measurements were processed as interclass correlation coefficient (ICC), Pearson and Spearman correlation, and Bland-Altman plots. RESULTS: PMSG created with a 3D template had higher interclass correlation coefficient values and Pearson/Spearman correlation than fenestrations created from CT measurements. The rate of fenestration alignment with the target vessel was higher for PMSG created with a 3D template (p=0.007). CONCLUSIONS: PMSGs created with a 3D template are more reliable and have better fenestration alignment with the target vessel than PMSGs created based on CT measurements.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Médicos , Humanos , Prótesis Vascular , Stents , Reproducibilidad de los Resultados , Diseño de Prótesis , Resultado del Tratamiento , Aneurisma de la Aorta Abdominal/cirugía , Tomografía Computarizada por Rayos X
2.
J Endovasc Ther ; 30(1): 148-150, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35086373

RESUMEN

INTRODUCTION: An ectopic renal artery originating from the aortic bifurcation can strongly interfere with surgical or endovascular intervention in the infrarenal aorta. CASE: We present an infrarenal symptomatic aneurysm with a right ectopic/pelvic kidney associated with 1 renal artery originating from the aortic bifurcation. RESULT: During an endovascular aortic repair (EVAR) procedure, the dominant ectopic right kidney was perfused by an iliac branch device (IBD) used as an iliac extension. However, out of instructions for use (IFU), this is an "off-the-shelf" resolution for this type of rare case. CONCLUSION: The use of an "off-the-shelf" IBD to perform an EVAR with an ectopic renal artery, in patients unfit for open surgery, is a potentially valuable option.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Arteria Renal/diagnóstico por imagen , Arteria Renal/cirugía , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/complicaciones , Reparación Endovascular de Aneurismas , Resultado del Tratamiento , Riñón , Prótesis Vascular
3.
Ann Vasc Surg ; 89: 210-215, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36064129

RESUMEN

BACKGROUND: Published interim results of the extended provisional extension to induce complete attachment (e-PETTICOAT) technique suggested favorable remodeling in chronic type B Aortic Dissection (cTBAD). This report presents long-term results of the e-PETTICOAT technique for the management of cTBAD (without aneurysmal dilatation). METHODS: Patients with cTBAD below the 55 mm aortic size were eligible for the management using the e-PETTICOAT technique. Follow-up was conducted at 1, 2 and 5 years based on the computed tomography angiogram. All the presurgery risk factors (entry >1 cm, inner curve entry, fusiform index >0.65, false lumen > 22 mm, aortic size >40 mm, recurrent pain or hypertension, and Stanford Dissection Risk Calculation) and postsurgery complications were examined in the study. RESULTS: A total of 20 patients underwent the e-PETTICOAT surgery. The survival rate at 1, 2, and 5 years was 75%, 70%, and 64%, respectively, and the percentage of patients without any reinterventions was 100%, 93%, and 18%. Aortic degeneration was recognized in 30%, 55%, and 85% of the patients. Only 3 of the 20 patients were alive and without any reintervention after 5 years. The receiver operating curve analysis does not indicate any factor that would predict the remodeling result in the long-term follow-up. CONCLUSIONS: The use of e-PETTICOAT technique in cTBAD might not have a beneficial influence on the long-term results.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Stents , Procedimientos Endovasculares/efectos adversos , Resultado del Tratamiento , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Aortografía/métodos , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/etiología , Estudios Retrospectivos
4.
Medicina (Kaunas) ; 59(12)2023 Dec 12.
Artículo en Inglés | MEDLINE | ID: mdl-38138253

RESUMEN

Background and Objectives: Provisional extension to induce complete attachment (PETTICOAT) is suggested as being associated with a lower incidence of aorta-related events and fewer reinterventions compared to thoracic endovascular aortic repair (TEVAR) in patients with complicated acute, and subacute type B aortic dissections. Materials and Methods: This article is a systematic review and meta-analysis following the PRISMA guidelines. The Medline, PubMed, Embase, and Cochrane databases were searched, starting on 21 February 2022 and ending on 22 June 2022, to identify studies that investigated the rate of postoperative complications in patients treated with the PETTICOAT compared to the TEVAR. A random effects meta-analysis was performed. Of 2350 studies, 5 studies involving 360 patients were included: 143 patients after the PETTICOAT procedure and 217 after the TEVAR. Results: The meta-analysis of all studies showed that the rate of secondary endovascular reinterventions was smaller in patients treated with the PETTICOAT (n = 3 studies; OR, 0.30; 95% CI, 0.10 to 0.94; p = 0.04). The results of other postoperative complications (30-day mortality, mortality during follow-up, paraplegia, stroke, and occurrence of endoleak) were lower in the PETTICOAT group but were not statistically significant. The rate of postoperative renal failure was lower in patients treated with the TEVAR (n = 4; OR, 1.08; 95% CI, 0.46 to 2.51; p = 0.86). Conclusion: This meta-analysis suggests that the PETTICOAT procedure is related to the lower rate of secondary endovascular reinterventions for complicated acute, and subacute type B aortic dissections.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Prótesis Vascular , Reparación Endovascular de Aneurismas , Implantación de Prótesis Vascular/efectos adversos , Stents/efectos adversos , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/complicaciones , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/métodos , Resultado del Tratamiento , Disección Aórtica/cirugía , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/cirugía , Estudios Retrospectivos , Factores de Riesgo
5.
Int J Mol Sci ; 23(7)2022 Mar 24.
Artículo en Inglés | MEDLINE | ID: mdl-35408904

RESUMEN

Three-dimensionally-printed aortic templates are increasingly being used to aid in the modification of stent grafts in the treatment of urgent, complex aortic disorders, often of an emergency nature. The direct contact between the aortic template and the stent graft implies the necessity of complete sterility. Currently, the efficacy of sterilizing aortic templates and the effect of sterilization on the geometry of tubular aortic models are unknown. A complex case of aortic arch dissection was selected to prepare a 3D-printed aortic arch template, which was then manufactured in six popular printing materials: polylactic acid (PLA), nylon, polypropylene (PP), polyethylene terephthalate glycol (PETG), and a rigid and flexible photopolymer resin using fused deposition modeling (FDM) and stereolithography (SLA). The 3D models were contaminated with Geobacillus stearothermophilus broth and Bacillus atrophaeus. The sterilization was performed using three different methods: heat (105 °C and 121 °C), hydrogen peroxide plasma, and ethylene oxide gas. Before and after sterilization, the aortic templates were scanned using computed tomography to detect any changes in their morphology by comparing the dimensions. All sterilization methods were effective in the elimination of microorganisms. Steam sterilization in an autoclave at 121 °C caused significant deformation of the aortic templates made of PLA, PETG, and PP. The other materials had stable geometries, and changes during mesh comparisons were found to be submillimeter. Similarly, plasma, gas, and heat at 105 °C did not change the shapes of aortic templates observed macroscopically and using mesh analysis. All mean geometry differences were smaller than 0.5 mm. All sterilization protocols tested in our study were equally effective in destroying microorganisms; however, differences occurred in the ability to induce 3D object deformation. Sterilization at high temperatures deformed aortic templates composed of PLA, PETG, and PP. This method was suitable for nylon, flexible, and rigid resin-based models. Importantly, plasma and gas sterilization were appropriate for all tested printing materials, including PLA, PETG, PP, nylon, flexible and rigid resins. Moreover, sterilization of all the printed models using our novel protocol for steam autoclaving at 105 °C was also 100% effective, which could represent a significant advantage for health centers, which can therefore use one of the most popular and cheap methods of medical equipment disinfection for the sterilization of 3D models as well.


Asunto(s)
Disección Aórtica , Médicos , Desinfección , Humanos , Nylons , Poliésteres , Impresión Tridimensional , Vapor , Stents , Procedimientos Quirúrgicos Vasculares
6.
Rev Cardiovasc Med ; 21(1): 129-137, 2020 03 30.
Artículo en Inglés | MEDLINE | ID: mdl-32259912

RESUMEN

There have been indisputable developments in techniques for stabilizing acute aortic syndromes. However, aneurysmal degeneration following aortic dissection remains a problem to be solved. The currently available treatment options for aortic dissection still fail to take into account the known risk factors for aneurysmal degeneration. This is why we introduced a new approach to treating patients with an aortic dissection, called Complete Entry and Re-entry Neutralization (CERN). This is our initial report on the promising interim results. MATERIAL AND METHODS: 68 patients qualified for endovascular treatment of an acute or chronic aortic dissection. Computed tomography was performed post-operatively to assess aortic remodeling after 1/6/12/24/36 months. RESULTS: the 30-day mortality rate was 4.4%. In 29 cases (43%) unfavorable remodeling was noted in the follow-up. The most important factors leading to unfavorable remodeling were: uncovered re-entry tear including the infra-renal segment, no relining of dissection membranes and insufficient coverage of the descending aorta. We analyzed these factors to develop the CERN protocol. This concept consists of six basic rules: A. cover all entry tears, B. amplify the BMS radial force, C. use the STABILISE technique, D. consider using thrombus plugs, E. avoid stenting the visceral branches, F. spare the intercostal and lumbar side branches. CERN improves the rate of favorable remodeling from 25% to 85% (P = 0.0067). CONCLUSION: Introduction of the Complete Entry and Re-entry Neutralization protocol improves the rate of favorable remodeling following endovascular treatment of aortic dissection in mid-term follow-up in patients with diffused aortic dissection.


Asunto(s)
Aneurisma de la Aorta/cirugía , Disección Aórtica/cirugía , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Adulto , Anciano , Anciano de 80 o más Años , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/mortalidad , Disección Aórtica/fisiopatología , Aneurisma de la Aorta/diagnóstico por imagen , Aneurisma de la Aorta/mortalidad , Aneurisma de la Aorta/fisiopatología , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/mortalidad , Estudios de Casos y Controles , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/mortalidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Remodelación Vascular
7.
Ann Vasc Surg ; 66: 183-192, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31669476

RESUMEN

BACKGROUND: The aim of this paper was to evaluate a new technique called an "extended" provisional extension to induce complete attachment (e-PETTICOAT) technique. METHODS: In this prospective single-center clinical study, the primary safety end mid-term remodeling is evaluated for the new endovascular technique. It was based on a standard Petticoat and limited Stabilize technique, extended by the placement of 2 covered stents within the abdominal bare metal stent as parallel iliac stent grafts down to the iliac bifurcations. Computed tomographic angiography was performed postoperatively to assess aortic remodeling after 12 and 24 months. Changes in aortic size and volumes of the false and true lumen were assessed. RESULTS: Between January 2014 and December 2015, 17 patients were treated due to acute, complicated aortic dissection type III B, according to the DaBekey classification. All patients presented with branch vessel obstruction/compromise, including six cases with aortic impending rupture. A 100% technical success rate was recorded regarding the resolution of complications. Favorable remodeling was achieved in 100% of the cases. Complete false lumen thrombosis in the thoracic, infra-renal aorta and the iliac artery was noted. A small volume (9.51 ± 6.9 mL) contrast-enhanced false lumen in the abdominal aorta was observed in 76% of cases with stable aortic size after 1 and 2 years. No visceral branch occlusion, type I endo-leak, renal insufficiency or paraplegia was recorded in follow-up. CONCLUSIONS: The expanded PETTICOAT technique was feasible in achieving favorable remodeling in acute extensive aortic dissection. Extended followup is needed to ascertain long-term results. This article presents a series of 17 cases of a new endovascular method called E-PETTICOAT (EJVES 2018 https://doi.org/10.1016/j.ejvs.2018.07.038) used in complicated acute and extensive type IIIB dissections. Favorable remodeling was achieved in 100% cases with stable aorta diameter after 1 and 2 years. It was shown that the extended PETTICOAT technique gives good remodeling in acute and extensive aortic dissection. This method can potentially provide a one-step solution and an easier alternative to FEVAR/BEVAR procedures. In order to ensure favorable results, further research is needed on a wider scale with long-term followup.


Asunto(s)
Aneurisma de la Aorta/cirugía , Disección Aórtica/cirugía , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Remodelación Vascular , Enfermedad Aguda , Adulto , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/mortalidad , Disección Aórtica/fisiopatología , Aneurisma de la Aorta/diagnóstico por imagen , Aneurisma de la Aorta/mortalidad , Aneurisma de la Aorta/fisiopatología , Prótesis Vascular , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/mortalidad , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/mortalidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Estudios Retrospectivos , Factores de Riesgo , Stents , Factores de Tiempo , Resultado del Tratamiento
8.
J Vasc Surg ; 70(6): 1782-1791, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31521400

RESUMEN

OBJECTIVE: This study examined the outcomes of our novel concept of expanded provisional extension to induce complete attachment strategy (Petticoat) for safety, durability, and remodeling of chronic type B dissections. METHODS: Twenty patients with chronic type B aortic dissection with aneurysmal degeneration qualified for an expanded Petticoat strategy (stent graft in the thoracic, plus additional distal bare stent into the abdominal and infrarenal aorta, followed by parallel stent grafts into common iliac arteries). Computed tomography was performed preoperatively and at 1, 6, and 12 months after surgery. RESULTS: The primary technical success was 100%. The 30-day mortality rate was 0%. At 12 months, favorable aortic remodeling and complete false lumen (FL) thrombosis were noted as 100% in the thoracic and infrarenal aorta. The volume of contrast-enhanced FL decreased from 186 ± 75.4 mL all along the dissection preoperatively (range, 70-360 mL), to 6.32 ± 5.4 mL postoperatively (range, 0.0-19.6 mL) and was only observed in the visceral aorta (P = .000089). Despite persistent flow in a small area of the FL, the maximal aortic size was stable in follow-up. Neither paraplegia nor visceral branch occlusion were noted in the follow-up. CONCLUSIONS: The treatment of aortic dissections with an expanded Petticoat strategy seems to be safe and offers good early results. It significantly reduced the volume of contrast enhanced FL. Further investigation of any subsequent results will be necessary.


Asunto(s)
Aneurisma de la Aorta/cirugía , Disección Aórtica/cirugía , Stents , Procedimientos Quirúrgicos Vasculares/instrumentación , Procedimientos Quirúrgicos Vasculares/métodos , Adulto , Anciano , Anciano de 80 o más Años , Disección Aórtica/clasificación , Aneurisma de la Aorta/clasificación , Enfermedad Crónica , Estudios de Cohortes , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
9.
J Endovasc Ther ; 26(4): 544-547, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-31190631

RESUMEN

Purpose: To demonstrate the feasibility of augmented reality visualization in planning and navigating endovascular aortic repair. Technique: A 77-year-old patient with abdominal aortic aneurysm was treated with endovascular repair. An augmented reality head-mounted display was used during the procedure. The aneurysm and bones were projected as 3-dimensional holograms. The operator controlled the device with gestures and voice commands (movement, rotation, cutting through, and zooming). Moreover, the hologram was placed in front of the angiography monitor and manually registered with fluoroscopy. Conclusion: Augmented reality with holographic rendering is feasible and helpful during endovascular aortic repair. Its routine use could possibly lead to shorter operating time, reduced contrast volume, and lower radiation dose; however, larger studies are required to obtain statistically significant results on the outcomes.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Holografía , Cirugía Asistida por Computador , Anciano , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aortografía , Implantación de Prótesis Vascular/instrumentación , Procedimientos Endovasculares/instrumentación , Holografía/instrumentación , Humanos , Imagenología Tridimensional , Imagen Multimodal , Gafas Inteligentes , Cirugía Asistida por Computador/instrumentación , Resultado del Tratamiento
10.
Ann Vasc Surg ; 54: 336.e5-336.e8, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30114499

RESUMEN

Thoracic endovascular aortic repair (TEVAR) is an established treatment option, although some anatomical challenges require a through-and-through wire technique, and subsequently transapical access via minithoracotomy can be required. It is clear that an objective tool to facilitate decision-making is needed. A 3D print of a severely angulated aortic arch was used as a template to advance a stent graft, and this was achieved after pulling the top of the wire. This simulation assisted in decision-making relating to transapical access with a wire externalization. A 3D aortic print could be used in advance to simulate the TEVAR procedure and facilitate any other decisions regarding additional transapical access.


Asunto(s)
Aorta Torácica/anatomía & histología , Aneurisma de la Aorta Torácica/cirugía , Implantación de Prótesis Vascular/instrumentación , Procedimientos Endovasculares/instrumentación , Impresión Tridimensional , Anciano , Aorta Torácica/cirugía , Aortografía , Prótesis Vascular , Implantación de Prótesis Vascular/métodos , Procedimientos Endovasculares/métodos , Femenino , Humanos , Planificación de Atención al Paciente , Stents , Procedimientos Quirúrgicos Torácicos , Toracotomía
11.
J Endovasc Ther ; 25(5): 554-558, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30056789

RESUMEN

PURPOSE: To demonstrate the utility of a 3-dimensional (3D) printed template of the aortic arch in the construction of a fenestrated and scalloped physician-modified stent-graft (PMSG). CASE REPORT: A 73-year-old woman with descending thoracic aneurysm was scheduled for thoracic endovascular aortic repair after being disqualified for open surgery. Computed tomography angiography (CTA) revealed no proximal landing zone as the aneurysm began from the level of the left subclavian artery, so a fenestrated/scalloped PMSG was planned. To facilitate accurate placement of the openings in the graft, a 3D printed aortic arch template was prepared from the CTA data and gas sterilized. In the operating room, a Valiant stent-graft was inserted into the 3D printed template and deployed. Using ophthalmic cautery, a fenestration and a scallop were created; radiopaque markers were added. The PMSG was successfully deployed with no discrepancy between the openings and the target vessels. CONCLUSION: A 3D printed aortic arch template facilitates handmade fenestrations and scallops in PMSGs and may improve accuracy and quality.


Asunto(s)
Aneurisma de la Aorta Torácica/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Impresión Tridimensional , Stents , Anciano , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aortografía/métodos , Angiografía por Tomografía Computarizada , Femenino , Humanos , Modelos Anatómicos , Modelos Cardiovasculares , Diseño de Prótesis , Resultado del Tratamiento
14.
J Clin Med ; 12(21)2023 Oct 25.
Artículo en Inglés | MEDLINE | ID: mdl-37959199

RESUMEN

This study aimed to investigate the relationship between maximum transverse diameter (MTD) and volume measurements in patients who underwent reoperations after endovascular aneurysm repair (EVAR), and their association with the occurrence of endoleaks. The study included 51 patients who underwent EVAR and subsequent re-operations caused by endoleaks type I-III. In some number of events, multiple re-operations were needed. MTD was measured using the Horos software, and segmentations of the AAA were performed using 3D Slicer. This study first evaluated post-operative computed tomography angiography (CTA) to measure MTD and volume. Then, similar measurements were made in the control scan for re-operation qualification. Negative remodeling (increase in MTD and/or volume) was observed in 40 cases using MTD, and 48 cases using volume measurements. The volume measurement showed lower missed negatives than MTD, indicating its effectiveness in screening for negative remodeling (p < 0.001). Combining both methods identified 51 negative remodeling cases and 8 positive changes, with a higher sensitivity compared to MTD alone. The volume of the sac did not predict specific endoleak types. Decreases in MTD were observed in smaller sacs, with smaller volume changes. Volume measurement is a valuable screening tool, and combining MTD and volume enhances sensitivity. However, sac volume does not predict endoleak type.

15.
J Cardiovasc Dev Dis ; 10(11)2023 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-37998522

RESUMEN

We sought to determine the role of the patient-specific, three-dimensional (3D) holographic vascular model in patient medical knowledge and its influence on obtaining a more conscious informed consent process for percutaneous balloon angioplasty (PTA). Patients with peripheral arterial disease who had been scheduled for PTA were enrolled in the study. Information regarding the primary disease, planned procedure, and informed consent was recorded in typical fashion. Subsequently, the disease and procedure details were presented to the patient, showing the patients their individual model. A patient and medical supervisor equipped with mixed reality headsets could both simultaneously manipulate the hologram using gestures. The holographic 3D model had been created on a scale of 1:1 based on computed tomography scans. The patient's knowledge was tested by the completion of a questionnaire before and after the interaction in a mixed reality environment. Seventy-nine patients manipulated arterial holograms in mixed reality head-mounted devices. Before the 3D holographic artery model interaction, the mean ± standard deviation score of the knowledge test was 2.95 ± 1.21 points. After the presentation, the score had increased to 4.39 ± 0.82, with a statistically significant difference (p = 0.0000) between the two scores. Using a Likert scale from 1 to 5, the patients had scored the use of the 3D holographic model at 3.90 points regarding its usefulness in comprehending their medical condition; at 4.04 points regarding the evaluation of the holograms as helpful in understanding the course of surgery; and rated the model at 1.99 points in reducing procedure-related stress. Using a nominal scale (know or don't know), the patients had self-assessed their knowledge of the procedure before and after the 3D model presentation, with a score of 6.29 ± 2.01 and 8.39 ± 1.54, respectively. The study group tolerated the use of head-mounted devices. Only one patient had nausea and dizziness, while four patients experienced transient eye pain. The 3D holographic arterial model aided in the understanding of patients' knowledge regarding the disease and procedure, making the informed consent process more conscious. The holograms improved the patient's self-consciousness. Mixed reality headset-related complications were rare and within acceptable rates.

16.
J Clin Med ; 12(15)2023 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-37568488

RESUMEN

Appendix neuroendocrine neoplasm (ANEN) treatment is based on tumor size and proliferation markers. Recently, the role of the follicle-stimulating hormone receptor (FSHR) from the clinical perspective has also been increasingly discussed. The FSHR is expressed in the endothelial cells of both intratumoral and peritumoral blood vessels, where it contributes to neoangiogenesis and blood vessel remodeling. FSHR expression is associated with a range of tumor types, such as gastrointestinal tumors, and it is not detected in healthy tissues located more than 10 mm from the tumor site or in tumor lymphatics. In this study, we evaluated the expression of FSHR and CD31 in the blood vessels of ANENs in females and males with confirmed histopathology. We conducted a quantitative analysis of the immunohistochemical reactions and found a higher number of microvessels in the mucosa and submucosa of neuroendocrine tumors in the appendix. A higher level of FSHR expression was observed in women. Future research should consider whether an elevated number of blood vessels along with a strong pattern of FSHR expression may influence future treatment strategies.

17.
J Clin Med ; 11(4)2022 Feb 11.
Artículo en Inglés | MEDLINE | ID: mdl-35207223

RESUMEN

The current stratification model of aneurysm rupture seems to be insufficient in some clinical cases. In our study, we determined the differences in wall structure between ruptured and unruptured aneurysms. We obtained computed tomography angiograms and categorized them into the following three groups, consisting of 49 patients each: the group with ruptured abdominal aortic aneurysms (rAAA), symptomatic (sAAA), and asymptomatic (aAAA). The three-dimensional AAA anatomy was digitally reconstructed for each patient through semi-automatically obtained segmentation, and each aneurysm was distinguished by the following three parameters: AFL (aneurysm flow lumen), ILT (intraluminal thrombus), and calcifications. The AFL volume was greater in rAAA compared with aAAA (p = 0.004), the ILT volume was greater in aAAA than in rAAA (p = 0.013), and the AFL/ILT surface ratio was bigger in rAAA than in aAAA (p < 0.001), sAAA than in aAAA (p = 0.033), and rAAA than in sAAA (p = 0.016). AFL/ILT surface*100 was defined as an independent predictive factor of rAAA to aAAA (OR 1.187; 95% CI 1.099-1.281), to sAAA (OR 1.045; 95% CI 1.004-1.087), and in sAAA vs. aAAA (OR 1.067; 95% CI 1.017-1.119). Consequently, the wall of rAAA differs significantly from unruptured aneurysms. The AFL/ILT surface ratio might indicate an increased risk of aneurysm rupture and the occurrence of symptoms in AAA.

19.
J Clin Med ; 11(18)2022 Sep 19.
Artículo en Inglés | MEDLINE | ID: mdl-36143138

RESUMEN

Type II endoleak is one of the most common and problematic complications after endovascular aneurysm repair. It has been suggested that the inferior mesenteric artery (IMA) embolization could prevent further adverse events and postoperative complications. This article is a systematic review and meta-analysis following PRISMA guidelines. The Medline, PubMed, Embase, and Cochrane databases were used to identify studies that investigated the effect of IMA embolization on the occurrence of type II endoleaks and secondary interventions in a group of patients with abdominal aortic aneurysm who underwent EVAR compared with results after EVAR procedure without embolization. A random effects meta-analysis was performed. Of 3510 studies, 6 studies involving 659 patients were included. Meta-analysis of all studies showed that the rate of secondary interventions was smaller in patients with IMA embolization (OR, 0.17; SE, 0.45; 95% CI, 0.07 to 0.41; p < 0.01; I2 = 0%). The occurrence of type II endoleaks was also smaller in the embolization group (OR, 0.37; SE, 0.21; 95% CI, 0.25 to 0.57; p < 0.01; I2 = 16.20%). This meta-analysis suggests that IMA embolization correlates with lower rates of type II endoleaks and secondary interventions.

20.
J Clin Med ; 11(8)2022 Apr 13.
Artículo en Inglés | MEDLINE | ID: mdl-35456273

RESUMEN

The goal of this study was to describe the surgical results of physician-modified endografts (PMEG) utilizing a 3D aortic template in a center with no prior experience in complex endovascular aortic repairs. Forty-three patients underwent physician-modified graft stent implantation using a 3D aortic model. The inclusion criteria were juxtarenal and suprarenal aortic aneurysms, type IV thoracoabdominal aneurysms, and type IA endoleak after endovascular aortic repair. In asymptomatic patients, the diameter threshold for aneurysm repair was 5.5 cm in males and 5.0 cm in females. 3D aortic templates were prepared from the patient's computed tomography angiography scans and sterilized before use in the operating suite. Forty-three stent grafts were modified with the use of a 3D printing template. A total of 162 reinforced fenestrations (37 celiac, 43 right renal, 39 left renal, 43 superior mesenteric) with a mean of 3.8 per patient were performed. All PMEGs had a posterior reducing-diameter tie and a preloaded guidewire. The mean modification time was 86 ± 12 min. The mean follow-up was 14 ± 12 months. The 30-day mortality was 12%. During the follow-up period, the patency rate was 95% per the superior mesenteric artery, 93% per right renal artery, 95% per left renal artery, and 89% per celiac trunk. Twelve (28%) patients had endoleak, of which type I or III was present in 5 (12%) patients, and type II in 7 (16%). 3D printing can be successfully integrated into the physician's everyday practice of stent graft modification. However, the use of this approach in centers without experience performing complex aortic procedures results in worse surgical metrics than those previously reported.