Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Catheter Cardiovasc Interv ; 96(6): E646-E652, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32073725

RESUMEN

OBJECTIVE: To assess the utility of the 65-cm-long Gore DrySeal sheath when compared to the standard 36-cm-long Edwards expandable sheath (e-sheath) for transcatheter pulmonary valve implantation (TPVI) with the Edwards Sapien 3 valve. METHODS: All patients who underwent TPVI with the Sapien 3 valve, excluding those performed via hybrid approach, at our center between September 2015 and November 2019 were retrospectively reviewed and compared between two groups. RESULTS: A total of 94 patients were enrolled; 29 patients underwent TPVI with the Sapien valve using the DrySeal sheath and 65 underwent TPVI using the e-sheath. The height and body weight of patients implanted using the DrySeal sheath ranged from 137 to 193 cm and from 33 to 129 kg, respectively. Valve delivery time was significantly shorter in the DrySeal group (median time 4 min 33 s vs. 9 min 6 s, p = .002). There were no complications in the DrySeal group (0/27). Nine procedural complications occurred in the e-sheath group (9/65), five of which were potentially directly related to sheath choice, including tricuspid valve injury in four and embolization of the tip of the e-sheath during retrieval of a ruptured balloon in one patient. CONCLUSIONS: TPVI with the Sapien 3 valve using the 65-cm-long DrySeal sheath facilitates faster and safer valve implantation when compared to the e-sheath.


Asunto(s)
Cateterismo Cardíaco/instrumentación , Catéteres Cardíacos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Pulmonar/cirugía , Estenosis de la Válvula Pulmonar/cirugía , Válvula Pulmonar/cirugía , Adolescente , Adulto , Cateterismo Cardíaco/efectos adversos , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Tempo Operativo , Complicaciones Posoperatorias/etiología , Diseño de Prótesis , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/fisiopatología , Insuficiencia de la Válvula Pulmonar/diagnóstico por imagen , Insuficiencia de la Válvula Pulmonar/fisiopatología , Estenosis de la Válvula Pulmonar/diagnóstico por imagen , Estenosis de la Válvula Pulmonar/fisiopatología , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
2.
Catheter Cardiovasc Interv ; 94(4): 625-635, 2019 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-31471941

RESUMEN

OBJECTIVES: We sought to delineate the risk factors for infective endocarditis (IE) in patients undergoing transcatheter pulmonary valve replacement (TCPVR). BACKGROUND: Despite the therapeutic benefits of TCPVR for treatment of dysfunctional right ventricular outflow tracts, IE is a major complication of the approach. Specific hemodynamic gradients and patient immune status as predisposing factors for IE are largely unexplored. METHODS: We performed a retrospective review of patients who had undergone TCPVR at UCLA between October 2010 and October 2017. Cases of IE were diagnosed based on the modified Duke criteria. RESULTS: Two hundred and thirty-five cases of TCPVR were performed with a mean follow-up of 2.6 years (range 0.0-8.0 years). Sixteen distinct IE events developed in 13 patients (Melody™ n = 12, SAPIEN n = 1), with a median time from implant to IE of 3.3 years (range 2.0-7.2 years). Univariate Cox regression showed that immunocompromised status was significantly associated with the development of IE hazard ratios (HR 5.43 [1.80-16.4], p = .003). Kaplan-Meier curves show that the 5-year freedom from IE among immunocompetent patients was 87% (95% CI 78-96%) versus 64% (95% CI 39-89%) among immunocompromised patients (log-rank p = .02). Postimplant right ventricular systolic pressure was higher among immunocompromised patients (p = .03). The risk of IE post-TCPVR in immunocompromised patients with residual pulmonary stenosis was 43%. CONCLUSIONS: Among the risk factors examined in this study, immunocompromised status was the most significant predictor of IE development post-TCPVR. Patients with the lowest risk of IE are those with competent immune systems, without a history of IE, and with minimal residual pulmonary valve gradients post-TCPVR.


Asunto(s)
Cateterismo Cardíaco/efectos adversos , Endocarditis/etiología , Cardiopatías Congénitas/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Prótesis Valvulares Cardíacas/efectos adversos , Infecciones Relacionadas con Prótesis/etiología , Insuficiencia de la Válvula Pulmonar/cirugía , Estenosis de la Válvula Pulmonar/cirugía , Válvula Pulmonar/cirugía , Adolescente , Adulto , Cateterismo Cardíaco/instrumentación , Toma de Decisiones Clínicas , Endocarditis/diagnóstico , Endocarditis/inmunología , Femenino , Cardiopatías Congénitas/diagnóstico por imagen , Cardiopatías Congénitas/inmunología , Cardiopatías Congénitas/fisiopatología , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Hemodinámica , Humanos , Huésped Inmunocomprometido , Masculino , Supervivencia sin Progresión , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/inmunología , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/fisiopatología , Insuficiencia de la Válvula Pulmonar/diagnóstico por imagen , Insuficiencia de la Válvula Pulmonar/inmunología , Insuficiencia de la Válvula Pulmonar/fisiopatología , Estenosis de la Válvula Pulmonar/diagnóstico por imagen , Estenosis de la Válvula Pulmonar/inmunología , Estenosis de la Válvula Pulmonar/fisiopatología , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Adulto Joven
3.
Catheter Cardiovasc Interv ; 93(2): 324-329, 2019 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-30351525

RESUMEN

OBJECTIVES: To describe a multicenter experience of percutaneous transcatheter pulmonary valve replacement (TPVR) using the Edwards SAPIEN S3 valve without the use of a prior stent ("pre-stenting"). BACKGROUND: The SAPIEN S3 and XT valves have durable cobalt-chromium stent frames which may allow for TPVR in large diameter dysfunctional right ventricular outflow tracts (RVOTs) without pre-stenting the landing zone. METHODS: A retrospective review was performed of all patients with Congenital Heart Disease and dysfunctional RVOT who underwent TPVR using the SAPIEN valve without the use of a pre-stent. Imaging data, procedural elements, and clinical follow-up data were collected to evaluate short and intermediate-term results. RESULTS: Fifty-seven patients underwent percutaneous placement of the SAPIEN valve in the pulmonary position without the use of pre-stenting. The anatomical substrate varied: native RVOTs (n = 41), conduits (n = 10), and bioprosthetic valves (n = 6). There were no cases in which the valve could not be implanted and no cases of valve embolization or misplacement. On follow-up (range 1 month to 2.2 years, median 5.3 months), no patients had significant obstruction or regurgitation around the valve. There were no frame fractures. There were no procedural deaths. Major complications included severe aortic compression (n = 1) requiring surgical explantation and tricuspid valve injury requiring surgical intervention (n = 2). CONCLUSIONS: This limited multi-institutional experience demonstrates that the SAPIEN valve can be used for TPVR without the use of a pre-stent without medium-term risk of frame fracture, paravalvar leak, or embolization. Longer term follow-up is required to fully assess this method.


Asunto(s)
Cateterismo Cardíaco/instrumentación , Enfermedades de las Válvulas Cardíacas/cirugía , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Válvula Pulmonar/cirugía , Stents , Obstrucción del Flujo Ventricular Externo/cirugía , Adolescente , Adulto , Anciano , Cateterismo Cardíaco/efectos adversos , Niño , Preescolar , Femenino , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/fisiopatología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/fisiopatología , Recuperación de la Función , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos , Obstrucción del Flujo Ventricular Externo/diagnóstico por imagen , Obstrucción del Flujo Ventricular Externo/fisiopatología , Adulto Joven
4.
Catheter Cardiovasc Interv ; 91(2): 277-284, 2018 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-28895275

RESUMEN

OBJECTIVES: To provide a comparison of the outcome of infective endocarditis (IE) in patients undergoing transcatheter pulmonary valve replacement (TPVR) versus surgical pulmonary valve replacement (SPVR). BACKGROUND: Although TPVR is thought to be associated with a higher risk of IE than SPVR, there is paucity of data to support this. METHODS: Patients who underwent TPVR or SPVR at UCLA between October 2010 and September 2016 were included and retrospectively analyzed. RESULTS: Three hundred forty-two patients underwent PVR at UCLA including 134 SPVR and 208 TPVR. Patients undergoing TPVR were more likely to have had a history of endocarditis than those undergoing SPVR (5.3% vs. 0.7%, P = 0.03) and a right ventricle to pulmonary artery (RV to PA) conduit (37% vs. 17%, P = 0.0001). Two SPVR and seven TPVR patients developed IE with a 4-year freedom from endocarditis of 94.0% in the SPVR versus 84% in the TPVR group (P = 0.13). In patients who underwent TPVR and developed endocarditis, the mean gradient across the RVOT prior to intervention was higher (28.1 ± 4.5 vs. 17.4 ± 0.6 mmHg, P = 0.02) and were more likely to have a conduit (71% vs. 36%, P = 0.049). CONCLUSIONS: In this study, patients undergoing TPVR were not at a higher risk of IE than patients undergoing SPVR. TPVR patients were more likely to have had a prior history of IE and RV-PA conduit. The patients at highest risk were those with stenotic RV to PA conduits who were treated with TPVR.


Asunto(s)
Cateterismo Cardíaco/efectos adversos , Endocarditis/epidemiología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Válvula Pulmonar/cirugía , Adolescente , Adulto , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/métodos , Niño , Endocarditis/diagnóstico , Endocarditis/terapia , Femenino , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Incidencia , Los Angeles/epidemiología , Masculino , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/fisiopatología , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
5.
JACC Adv ; 2(10): 100701, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38938489

RESUMEN

Background: Altered coagulation is a striking feature of COVID-19. Adult patients with congenital heart disease (ACHD) are prone to thromboembolic (TE) and bleeding complications. Objectives: The purpose of this study was to investigate the prevalence and risk factors for COVID-19 TE/bleeding complications in ACHD patients. Methods: COVID-19-positive ACHD patients were included between May 2020 and November 2021. TE events included ischemic cerebrovascular accident, systemic and pulmonary embolism, deep venous thrombosis, myocardial infarction, and intracardiac thrombosis. Major bleeding included cases with hemoglobin drop >2 g/dl, involvement of critical sites, or fatal bleeding. Severe infection was defined as need for intensive care unit, endotracheal intubation, renal replacement therapy, extracorporeal membrane oxygenation, or death. Patients with TE/bleeding were compared to those without events. Factors associated with TE/bleeding were determined using logistic regression. Results: Of 1,988 patients (age 32 [IQR: 25-42] years, 47% male, 59 ACHD centers), 30 (1.5%) had significant TE/bleeding: 12 TE events, 12 major bleeds, and 6 with both TE and bleeding. Patients with TE/bleeding had higher in-hospital mortality compared to the remainder cohort (33% vs 1.7%; P < 0.0001) and were in more advanced physiological stage (P = 0.032) and NYHA functional class (P = 0.01), had lower baseline oxygen saturation (P = 0.0001), and more frequently had a history of atrial arrhythmia (P < 0.0001), previous hospitalization for heart failure (P < 0.0007), and were more likely hospitalized for COVID-19 (P < 0.0001). By multivariable logistic regression, prior anticoagulation (OR: 4.92; 95% CI: 2-11.76; P = 0.0003), cardiac injury (OR: 5.34; 95% CI: 1.98-14.76; P = 0.0009), and severe COVID-19 (OR: 17.39; 95% CI: 6.67-45.32; P < 0.0001) were independently associated with increased risk of TE/bleeding complications. Conclusions: ACHD patients with TE/bleeding during COVID-19 infection have a higher in-hospital mortality from the illness. Risk of coagulation disorders is related to severe COVID-19, cardiac injury during infection, and use of anticoagulants.

6.
J Am Coll Cardiol ; 77(13): 1644-1655, 2021 04 06.
Artículo en Inglés | MEDLINE | ID: mdl-33795039

RESUMEN

BACKGROUND: Adults with congenital heart disease (CHD) have been considered potentially high risk for novel coronavirus disease-19 (COVID-19) mortality or other complications. OBJECTIVES: This study sought to define the impact of COVID-19 in adults with CHD and to identify risk factors associated with adverse outcomes. METHODS: Adults (age 18 years or older) with CHD and with confirmed or clinically suspected COVID-19 were included from CHD centers worldwide. Data collection included anatomic diagnosis and subsequent interventions, comorbidities, medications, echocardiographic findings, presenting symptoms, course of illness, and outcomes. Predictors of death or severe infection were determined. RESULTS: From 58 adult CHD centers, the study included 1,044 infected patients (age: 35.1 ± 13.0 years; range 18 to 86 years; 51% women), 87% of whom had laboratory-confirmed coronavirus infection. The cohort included 118 (11%) patients with single ventricle and/or Fontan physiology, 87 (8%) patients with cyanosis, and 73 (7%) patients with pulmonary hypertension. There were 24 COVID-related deaths (case/fatality: 2.3%; 95% confidence interval: 1.4% to 3.2%). Factors associated with death included male sex, diabetes, cyanosis, pulmonary hypertension, renal insufficiency, and previous hospital admission for heart failure. Worse physiological stage was associated with mortality (p = 0.001), whereas anatomic complexity or defect group were not. CONCLUSIONS: COVID-19 mortality in adults with CHD is commensurate with the general population. The most vulnerable patients are those with worse physiological stage, such as cyanosis and pulmonary hypertension, whereas anatomic complexity does not appear to predict infection severity.


Asunto(s)
COVID-19 , Procedimientos Quirúrgicos Cardíacos , Cianosis , Cardiopatías Congénitas , Hipertensión Pulmonar , Adulto , COVID-19/mortalidad , COVID-19/terapia , Prueba de COVID-19/métodos , Procedimientos Quirúrgicos Cardíacos/métodos , Procedimientos Quirúrgicos Cardíacos/estadística & datos numéricos , Causalidad , Comorbilidad , Cianosis/diagnóstico , Cianosis/etiología , Cianosis/mortalidad , Femenino , Salud Global/estadística & datos numéricos , Cardiopatías Congénitas/clasificación , Cardiopatías Congénitas/epidemiología , Cardiopatías Congénitas/fisiopatología , Cardiopatías Congénitas/terapia , Hospitalización/estadística & datos numéricos , Humanos , Hipertensión Pulmonar/diagnóstico , Hipertensión Pulmonar/etiología , Hipertensión Pulmonar/mortalidad , Masculino , Mortalidad , Gravedad del Paciente , Factores de Riesgo , SARS-CoV-2/aislamiento & purificación , Evaluación de Síntomas
7.
World J Pediatr Congenit Heart Surg ; 11(4): 411-416, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32645780

RESUMEN

BACKGROUND: We sought to describe invasive hemodynamic measurements in patients with tricuspid stenosis (TS) undergoing transcatheter tricuspid valve-in-valve (TVIV) implantation immediately pre- and postimplantation. Development of TS in patients who have undergone surgical tricuspid valve replacement with a bioprosthetic valve is a serious complication that leads to elevated right atrial (RA) pressures and decreased cardiac output. Transcatheter TVIV implantation is a viable alternative to surgical tricuspid valve replacement, but data on the hemodynamic consequences of TVIV for the treatment of severe TS are currently limited to echocardiographic assessment of Doppler-derived gradients. METHODS: Eleven patients undergoing transcatheter TVIV implantation with moderate to severe bioprosthetic valve stenosis were selected for retrospective review. Right atrial mean pressure, right ventricular (RV) systolic and end-diastolic pressure, mean diastolic RA-RV pressure gradient, pulmonary artery capillary wedge pressure, pulmonary artery systolic, end-diastolic and mean pressures, and pulmonary artery pulsatility index (PAPi) both before and after transcatheter valve placement were collected from catheterization reports. RESULTS: After transcatheter TVIV implantation, the mean TS gradient decreased significantly (P < .01), while the mean RV end-diastolic pressure increased (P = .046). Pulmonary artery pulsatility index also increased as the TS was relieved (P = .039). CONCLUSIONS: Tricuspid valve-in-valve implantation results in immediate relief of TS, leading to increased RV preload with resultant augmentation of RV and pulmonary pressures. Increased PAPi following the procedure demonstrates acute improvement in RV output but remains low due to the failure of the RA pressure to decline significantly immediately following intervention.


Asunto(s)
Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Hemodinámica/fisiología , Monitoreo Intraoperatorio/métodos , Estenosis de la Válvula Tricúspide/cirugía , Válvula Tricúspide/cirugía , Adulto , Ecocardiografía , Femenino , Humanos , Masculino , Estudios Retrospectivos , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Estenosis de la Válvula Tricúspide/diagnóstico
8.
World J Pediatr Congenit Heart Surg ; 11(3): 295-303, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-32294003

RESUMEN

OBJECTIVES: We aimed to evaluate the utility of computed tomography angiography (CTA) for coronary compression (CC) prediction in patients with congenital heart disease undergoing balloon-expandable transcatheter pulmonary valve replacement (TPVR). BACKGROUND: Coronary compression is a serious complication of TPVR, but the value of preprocedural CTAs to assess CC risk is largely unexplored. METHODS: In all, 586 patients underwent TPVR between January 2009 and July 2018. Adults with a pre-TPVR CTA and children with a CTA performed less than one year prior to TPVR were included. Patients with poor CTA image quality or with aborted cases due to reasons other than CC were excluded. Sixty-six patients were finally included. Cardiac anatomy was assessed via multiplanar reconstruction of CTAs. RESULTS: Coronary compression occurred in 9 (14%) of the 66 patients who underwent TPVR. Most CC cases (seven of nine) occurred in patients with conduits. Proximity of the right ventricular outflow tract (RVOT) landing zone to the coronary arteries and to the chest wall was a significant risk factor for compression (P < .001 and P = .019, respectively). Compression risk increased significantly if patients had an RVOT to coronary artery distance of ≤3 mm (P < .001) and an RVOT to chest wall distance of ≤8 mm (P = .026). Anomalous course of coronary arteries was another significant univariate risk factor (P = .003). CONCLUSIONS: Right ventricular outflow tract landing zone distance of ≤3 mm to a coronary artery, landing zone distance of ≤8 mm to the chest wall, and anomalous coronary arteries are associated with increased CC risk. Electrocardiogram gating may not be necessary if coronary arteries are opacified on CTAs. Larger studies are needed to explore and confirm these coronary artery compression risk factors.


Asunto(s)
Cateterismo Cardíaco , Angiografía por Tomografía Computarizada , Vasos Coronarios/cirugía , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Pulmonar/cirugía , Válvula Pulmonar/cirugía , Adolescente , Adulto , Anciano , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Niño , Femenino , Cardiopatías Congénitas/cirugía , Humanos , Masculino , Persona de Mediana Edad , Pacientes , Estudios Retrospectivos , Resultado del Tratamiento , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA