Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 111
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
J Artif Organs ; 2023 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-37474830

RESUMEN

In veno-arterial extracorporeal membrane oxygenation (VA-ECMO) treatment, the mixing zone is a key hemodynamic factor that determines the efficacy of the treatment. This study aimed to evaluate the applicability of a novel ultrasound technique called vector flow imaging (VFI) for visualizing complex flow patterns in an aorta phantom under VA-ECMO settings. VFI experiments were performed to image aortic hemodynamics under VA-ECMO treatment simulated in an anthropomorphic thoracic aorta phantom using a pulsatile pump (cardiac output: 2.7 L/min) and an ECMO pump with two different flow rates, 0.35 L/min and 1.0 L/min. The cardiac cycle of hemodynamics in the ascending aorta, aortic arch, and descending aorta was visualized, and the spatio-temporal dynamics of flow vectors were analyzed. VFI successfully visualized dynamic flow patterns in the aorta phantom. When the flow rate of the ECMO pump increased, ECMO flow was more dominant than cardiac output in the diastole phase, and the speed of cardiac output was suppressed in the systole phase. Vortex flow patterns were also detected in the ascending aorta and the arch under both ECMO flow rate conditions. The VFI technique may provide new insights into aortic hemodynamics and facilitates effective and safe VA-ECMO treatment.

2.
J Clin Monit Comput ; 37(5): 1361-1367, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37166692

RESUMEN

PURPOSE: Skin microvessels maintain temperature homeostasis by contracting and dilating upon exposure to changes in temperature. Under general anesthesia, surgical invasiveness, including incisions and coagulation, and the effects of anesthetics may cause variations in the threshold temperature, leading to the constriction and dilation of cutaneous blood vessels. Therefore, studies on skin microvascular circulation are necessary to develop appropriate interventions for complications during surgery. METHODS: We visualized and quantified skin microcirculatory fluctuations associated with temperature variations using a light-emitting diode photoacoustic imaging (LED-PAI) device. The hands of ten healthy volunteers were stressed with four different water temperatures [25℃ (Control), 15℃ (Cold1), 40℃ (Warm), and 15℃ (Cold2)]. The photoacoustic images of the fingers were taken under each condition, and the microvascular flow owing to temperature stress was quantified as the area of photoacoustic signal (S) in each image. The S values were compared with the variations in blood flow (Q) measured by laser Doppler flowmetry (LDF). RESULTS: The correlation between Q and S according to the 40 measurements was r = 0.45 (p<0.01). In addition, the values of S under each stress condition were as follows: Scontrol = 10,826 ± 3364 pixels, Scold1 = 8825 ± 2484 pixels, Swarm = 13,369 ± 3001 pixels, and Scold2 = 8838 ± 1892 pixels; the differences were significant. The LDF blood flow (Q) showed similar changes among conditions. CONCLUSION: These findings suggest that the LED-PAI device could be an option for evaluating microcirculation in association with changes in temperature.


Asunto(s)
Técnicas Fotoacústicas , Humanos , Microcirculación , Temperatura , Piel/irrigación sanguínea , Hemodinámica , Flujo Sanguíneo Regional/fisiología , Flujometría por Láser-Doppler/métodos
3.
Tohoku J Exp Med ; 257(1): 7-15, 2022 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-35321981

RESUMEN

Right ventricular (RV) dysfunction caused by chronic pulmonary regurgitation (PR) is a major determinant of clinical outcome in adults with repaired tetralogy of Fallot (rTOF). However, the accurate assessment of RV function by conventional echocardiography remains challenging. This study tested the feasibility and usefulness of RV free-wall (RVFW) strain obtained by two-dimensional (2D) speckle-tracking echocardiography (STE) in evaluation of RV function in adults with rTOF by comparing cardiac magnetic resonance (CMR) imaging. We enrolled 22 consecutive patients (male/female, 8/14; mean age, 25.0 years) with rTOF who underwent transthoracic echocardiography at Tohoku University Hospital from July 2016 to June 2019. We measured RVFW strain by STE and compared them with 22 hemodynamically normal subjects (NOR) (male/female, 9/13; mean age, 32.0 years). The correlation between RV strain and CMR-derived RV ejection fraction (RVEF) or PR fraction (PRF) were also evaluated. All rTOF patients had more than moderate PR but were near asymptomatic. RVFW longitudinal strain (RVFW-LS) was significantly decreased in the rTOF group compared with that in the NOR group (-19.6 vs. -24.7, P < 0.01). In the rTOF group, RVFW-LS correlated with PRF (r = 0.44, P < 0.05), whereas RVFW circumferential strain at the mid-ventricular level correlated with RVEF (r = 0.57, P < 0.01). Intra-observer variability of RVFW strain was acceptable. These results indicate that RV systolic function and PR severity in rTOF could be assessed by RVFW strain measured by 2D STE. This method is feasible and can be used as a complement to CMR imaging.


Asunto(s)
Insuficiencia de la Válvula Pulmonar , Tetralogía de Fallot , Disfunción Ventricular Derecha , Adulto , Ecocardiografía/efectos adversos , Ecocardiografía/métodos , Femenino , Humanos , Masculino , Insuficiencia de la Válvula Pulmonar/complicaciones , Insuficiencia de la Válvula Pulmonar/diagnóstico por imagen , Tetralogía de Fallot/complicaciones , Tetralogía de Fallot/diagnóstico por imagen , Tetralogía de Fallot/cirugía , Disfunción Ventricular Derecha/diagnóstico por imagen , Disfunción Ventricular Derecha/etiología , Función Ventricular Derecha
4.
Arch Orthop Trauma Surg ; 141(7): 1231-1239, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33454805

RESUMEN

INTRODUCTION: The "Comma sign" is a well-known indicator of the subscapularis torn edge of the shoulder. We undertook a histoanatomical study of the fiber bundle forming Comma sign (FBCS) to determine why FBCS is maintained even in cuff tear cases. MATERIALS AND METHODS: Part 1: five tissue blocks including the supraspinatus tendon (SSP), rotator interval (RI), and subscapularis tendon (SSC) out of 5 cuff-intact cadavers were histologically observed in serial sections. Part 2: another tissue blocks of 6 cuff-intact cadavers were serially sectioned along the estimated FBCS direction based on the Part 1 findings. Additionally, 5 tissue blocks of cuff-torn cadavers including the three components, SSP, FBCS, and SSC, were serially sectioned along the apparent FBCS. In one slice clearly demonstrating FBCS fibers out of each section series, the components were measured of the sound speed and visualized through a scanning acoustic microscope (SAM). RESULTS: At the lateral portion, RI tissue with the joint capsule became thick and tightly surrounded SSP. Similarly, thicker RI tissue adhered to SSC from the superior and bursal side. More laterally, the borders of SSP/FBCS and FBCS/SSC were unclear with intermingled fibers. At the lateral most portion, RI tissue formed a fiber bundle, FBCS, extending from SSP to the bursal side of SSC. The sound speeds of SSP and SSC were significantly faster than FBCS in both cuff-intact and cuff-torn slices. In SAM images of cuff-torn specimens the FBCS borders were all unclear. CONCLUSIONS: As FBCS extends from the capsule beneath SSP and to the bursal surface of SSC, the FBCS connection to SSP and SSC is hardly lost, even though SSP or SSC detaches from the greater or lesser tubercle, respectively. Additionally, as degeneration make the elasticity difference gradual, the stress concentration at the borders may be diminished, leading to less breakage of FBCS.


Asunto(s)
Lesiones del Manguito de los Rotadores/patología , Manguito de los Rotadores , Histocitoquímica , Humanos , Manguito de los Rotadores/anatomía & histología , Manguito de los Rotadores/patología
5.
Skin Res Technol ; 25(3): 347-354, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-30609153

RESUMEN

BACKGROUND: While determining sebaceous gland morphology is useful in the treatment of skin disorders such as acne, a non-invasive assessment method has not been developed. Since age and gender affect sebum level, differences in sebaceous gland morphology according to these factors were investigated. METHODS: Facial skin was measured using a high-frequency three-dimensional ultrasound microscope. First, the ultrasound images were compared with skin sections. Next, we assessed sebaceous gland morphology. Images of sebaceous gland in the cheeks of young male, young female and elderly female subjects were obtained using ultrasound microscopy, and en face images were processed to measure the sebaceous gland area. RESULTS: In the ultrasound images, sebaceous glands and also thin collagen fibers, which surrounded the glands, could be detected as low-intensity regions. We called them sebaceous units. In young male subjects, the sebaceous unit areas 900-µm beneath the skin surface were larger than those at 700 µm. In contrast, depth-dependent differences in sebaceous unit area were not observed in young female subjects, indicating that males had cauliflower-shaped sebaceous glands while young females had somewhat more cylindrical and smaller sebaceous glands than the young males. Regarding age, the areas of sebaceous units at 900 µm were diminished and the depth of maximum area was shallower in elderly female subjects compared to young female subjects. Hence, sebaceous glands are considered to shrink with age. CONCLUSION: Differences in facial sebaceous unit morphology between genders as well as by age groups could be observed using high-frequency ultrasound microscopy.


Asunto(s)
Pueblo Asiatico , Microscopía Acústica , Glándulas Sebáceas/anatomía & histología , Adulto , Factores de Edad , Anciano , Femenino , Humanos , Imagenología Tridimensional/métodos , Masculino , Persona de Mediana Edad , Glándulas Sebáceas/diagnóstico por imagen , Factores Sexuales
6.
Ultrason Imaging ; 41(6): 336-352, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31615353

RESUMEN

Echodynamography (EDG) is a computational method to estimate and visualize two-dimensional flow velocity vectors by applying dynamic flow theories to color Doppler echocardiography. The EDG method must be validated if applied to human cardiac flow function. However, a few studies of flow estimated have compared by EDG to the flow data were acquired by other methods. In this study, EDG was validated by comparing the analysis of estimating and visualizing flow velocity vectors obtained by original particle image velocimetry (PIV) based on a left ventricular (LV) phantom hydrogel (in vitro studies) and by EDG based on the virtual Doppler velocity. Velocity measured by PIV method and velocity estimated by EDG method in the perpendicular direction and the radial direction were compared. Regression analysis for the velocity estimated in the radial direction revealed an excellent correlation (R2=0.99, slope = 0.96) and moderate correlation in the perpendicular direction (R2=0.44, slope = 0.46). As revealed by the Bland-Altman plot, however, overestimations and higher relative error were observed in the perpendicular direction (0.51 ± 2.75 mm/s) and in the radial direction (-2.15 ± 21.13 mm/s). The percentage error of the norm-wise relative error of the velocity discrepancy is less than 10%, and velocity magnitude followed the same trends and are of comparable magnitude. These findings indicate that good estimates of velocity can be obtained by the EDG method. Therefore, the EDG method was appropriate for estimating and visualizing velocity vectors in clinical studies for higher measurement accuracy and reliability. The clinical in vivo application showed that the EDG method has the ability to visualize blood flow velocity vectors and differentiate the clinical information of vortex parameters both in normal and abnormal LV subjects. In conclusion, the EDG method has potentially greater clinical acceptance as a tool assessment of LV during the cardiac cycle.


Asunto(s)
Ecocardiografía Doppler en Color , Fantasmas de Imagen , Reología , Función Ventricular Izquierda , Algoritmos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Velocidad del Flujo Sanguíneo , Ventrículos Cardíacos , Humanos , Modelos Cardiovasculares , Estudios Prospectivos , Reproducibilidad de los Resultados
7.
J Electrocardiol ; 49(4): 596-602, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27156202

RESUMEN

BACKGROUND: Cardiac memory (CM) after idiopathic left ventricular tachycardia (ILVT) mimics ischemic T wave inversion (TWI) induced by acute coronary syndrome (ACS). We aimed to establish electrocardiography criteria for differentiating the CM from ischemic TWI. METHODS AND RESULTS: We evaluated 16 ILVT and 48 ACS patients. We identified TWI after ILVT in 9/16 patients (CM group), typically in leads II, III, aVF, aVR, and V4-6. The characteristics of CM were similar to TWI induced by ACS involving right coronary artery, but the CM group had more TWI in V4 and shorter QTc. The criteria of (1) positive T in aVL, (2) negative or isoelectric T in II, and (3) negative T in V4-6 or (4) QTc <430ms were 100% sensitive and 96% specific for the CM group. CONCLUSION: CM after ILVT can be differentiated in most cases from ischemic TWI by the distribution of TWI and the QTc.


Asunto(s)
Síndrome Coronario Agudo/diagnóstico , Electrocardiografía/métodos , Isquemia Miocárdica/diagnóstico , Taquicardia Ventricular/diagnóstico , Disfunción Ventricular Izquierda/diagnóstico , Síndrome Coronario Agudo/complicaciones , Adulto , Algoritmos , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Isquemia Miocárdica/etiología , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad , Taquicardia Ventricular/etiología , Disfunción Ventricular Izquierda/etiología
8.
J Orthop Sci ; 20(2): 397-402, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25592029

RESUMEN

BACKGROUND: Osteoarthritis is not only a disease of articular cartilage, but also of subchondral bone. It is difficult for ultrasound to evaluate subchondral bone because of permeability. This study aimed to evaluate sequential osteoarthritic changes of articular cartilage and subchondral bone from immobilized knees in rats with a photoacoustic (PA) imaging system. METHODS: The unilateral knee joints of adult male rats were immobilized with an internal fixator (IM group) for 4 and 8 weeks. Sham operated animals had holes drilled in the femur and tibia and screws inserted without a plate (control group). A whole proximal third of the tibia was obtained. The specimens were immersed in normal saline and scanned by the PA imaging system, which can create both ultrasound (US) and PA imaging. After the scanning, specimens were fixed with paraformaldehyde, decalcified and embedded in paraffin. Thinly sliced tissues were prepared for histological evaluation. PA signals from the articular cartilage and subchondral bone were independently evaluated. RESULTS: Gross observations showed that fibrillation occurred in the superficial layers and permeability of the articular cartilage increased. Histological observations showed that the articular cartilage became thicker and the bone marrow space expanded during immobilization. US images by the PA imaging system could evaluate the articular cartilage. PA signals from the articular cartilage and subchondral bone increased with the duration of immobilization and the difference, compared to the control group, was significant. CONCLUSIONS: The PA imaging system could evaluate articular cartilage and subchondral bone simultaneously.


Asunto(s)
Cartílago Articular/patología , Diagnóstico por Imagen , Articulación de la Rodilla/patología , Técnicas Fotoacústicas , Animales , Inmovilización , Masculino , Ratas , Ratas Sprague-Dawley
9.
Knee Surg Sports Traumatol Arthrosc ; 22(11): 2874-83, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24013446

RESUMEN

PURPOSE: To elucidate the effects of intra-articular haemorrhage on the joint capsule of immobilized knees in rats. METHODS: The unilateral knee joints were immobilized using a plastic plate and screws. Sham operated rats had only screws inserted. A single injection of fresh autologous blood was given postoperatively into the knee joints of the immobilized blood injection (Im-B) and the Sham blood injection (Sm-B) groups. Normal saline was administered for the immobilized-saline injection (Im-S) group. Sagittal sections were prepared from the medial midcondylar region of the knee and assessed with histological, histomorphometric, and immunohistochemical methods. The range of motion (ROM) was measured, and the mechanical property of the capsule was assessed by scanning acoustic microscope. RESULTS: Absorption of the injected blood was delayed and made severe adhesions in the Im-B group. The length of the synovial membrane in the Im-B group was significantly shorter than that of the other groups. The ROM was significantly restricted in the Im-B group compared with the other groups. The elasticity of the posterior capsule in the Im-B group was significantly lower than that in the Sm-B group. Iron deposition was observed in the Im-B and Sm-B groups. Strong immunoreactivities of CD68, TGF-ß1, and α-SMA were observed in the adhesion area of the Im-B group. Joint immobilization with blood injection caused severe capsular adhesion and limited range of motion. Immunostaining related to fibrosis increased with joint haemorrhage. CONCLUSION: Intra-articular haemorrhage with joint immobilization might be an accelerated risk factor for joint contracture. It is likely that leaving a haematoma inside an immobilized joint should be avoided.


Asunto(s)
Contractura/patología , Hemartrosis/fisiopatología , Cápsula Articular/patología , Articulación de la Rodilla/patología , Membrana Sinovial/patología , Adherencias Tisulares/patología , Animales , Modelos Animales de Enfermedad , Inmovilización , Cápsula Articular/cirugía , Articulación de la Rodilla/cirugía , Masculino , Microscopía Electrónica de Rastreo , Rango del Movimiento Articular , Ratas , Ratas Sprague-Dawley , Sinovectomía
10.
J Shoulder Elbow Surg ; 23(5): 628-35, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24745312

RESUMEN

BACKGROUND: Rotator cuff degeneration is one of the multiple factors that lead to rotator cuff tears; however, the precise mechanism of such degeneration still remains unclear. In this study, we investigated the supraspinatus tendon enthesis to clarify the link between rotator cuff degeneration and oxidative stress in antioxidant enzyme superoxide dismutase 1 (Sod1)-deficient mice (Sod1(-/-)). METHODS: The supraspinatus tendon and humeral head were isolated and fixed to prepare histologic sections from wild-type and Sod1(-/-) male mice at 20 weeks of age. Hematoxylin-eosin staining was performed to assess the histomorphologic structure. To investigate the collagen fibers, we examined spatially aligned collagen fibers using a polarizing microscope and assessed the amount of collagen using immunohistochemical staining. To analyze the tissue elasticity, we measured the tissue acoustic properties using scanning acoustic microscopy. RESULTS: The Sod1(-/-) mice showed histologic changes, such as a misaligned 4-layered structure and fragmented tidemark, in the enthesis. Sod1 loss also decreased the amount of brightly diffracted light and type I collagen, indicating collagen downregulation. The scanning acoustic microscopy analysis showed that the speed and attenuation of sound were increased in the nonmineralized fibrocartilage of the Sod1(-/-) mice, suggesting decreased mechanical properties in the supraspinatus enthesis. CONCLUSION: Sod1 deficiency-induced degeneration is associated with impaired elasticity in the supraspinatus tendon enthesis, recapitulating human rotator cuff degeneration. These results suggest that intracellular oxidative stress contributes to the degeneration of rotator cuff entheses.


Asunto(s)
Cabeza Humeral/patología , Estrés Oxidativo , Manguito de los Rotadores/metabolismo , Manguito de los Rotadores/patología , Animales , Colágeno/metabolismo , Colágeno/ultraestructura , Modelos Animales de Enfermedad , Elasticidad , Cabeza Humeral/fisiopatología , Inmunohistoquímica , Masculino , Ratones , Microscopía Acústica , Microscopía de Polarización , Manguito de los Rotadores/fisiopatología , Superóxido Dismutasa/biosíntesis , Superóxido Dismutasa/genética , Superóxido Dismutasa-1
11.
Ann Vasc Dis ; 17(2): 157-163, 2024 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-38919325

RESUMEN

Objective: In patients with abdominal aortic aneurysm (AAA), early detection and optimal elective treatment before rupture are desirable. In the absence of an established public screening system, opportunistic screening during ultrasound examination for another purpose might be efficacious. The aim of this study was to evaluate the efficacy of opportunistic screening for AAA. Methods: This prospective multicenter observational study enrolled patients who were scheduled to undergo ultrasound for reasons other than AAA. After the ultrasound for the original purpose, evaluation of the abdominal aorta was added. If the abdominal aorta was clear enough for measurement, its diameter and shape were recorded. Furthermore, information on comorbidities was collected for each patient. Results: A total of 10325 patients (echocardiography: 6150; abdominal ultrasound: 4162) from 16 institutions were enrolled. The abdominal aorta was well visualized in 92.9% of patients who underwent echocardiography. Among 9791 patients, AAA was diagnosed in 122 (1.3%) (107 fusiform and 15 saccular), with a diameter range of 30-63 mm. The diagnostic rate increased with age. On multivariate analysis, older age, male sex, coronary artery disease, peripheral arterial disease, and smoking habituation were the risk factors for AAA. Conclusion: Opportunistic screening for AAA was efficacious.

12.
Med Phys ; 51(1): 428-438, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37983613

RESUMEN

BACKGROUND: Quantitative and comprehensive visualization of urinary flow dynamics in the urethra is crucial for investigating patient-specific mechanisms of lower urinary tract symptoms (LUTS). Although some methods can evaluate the global properties of the urethra, it is critical to assess the local information, such as the location of the responsible lesion and its interactions with urinary flow in relation to LUTS. This approach is vital for enhancing personalized and focal treatments. However, there is a lack of such diagnostic tools that can directly observe how the urethral shape and motion impact urinary flow in the urethra. PURPOSE: This study aimed to develop a novel transrectal ultrasound imaging modality based on the contrast-enhanced urodynamic vector projectile imaging (CE-UroVPI) framework and validate its clinical applicability for visualizing time-resolved flow dynamics in the urethra. METHODS: A new CE-UroVPI system was developed using a research-purpose ultrasound platform and a custom transrectal linear probe, and an imaging protocol for acquiring urodynamic echo data in male patients was designed. Thirty-four male patients with LUTS participated in this study. CE-UroVPI was performed to acquire ultrasound echo signals from the participant's urethra and urinary flow at various voiding phases (initiation, maintenance, and terminal). The ultrasound datasets were processed with custom software to visualize urinary flow dynamics and urethra tissue deformation. RESULTS: The transrectal CE-UroVPI system successfully visualized the time-resolved multidirectional urinary flow dynamics in the prostatic urethra during the initiation, maintenance, and terminal phases of voiding in 17 patients at a frame rate of 1250 fps. The maximum flow speed measured in this study was 2.5 m/s. In addition, when the urethra had an obstruction or an irregular partial deformation, the devised imaging modality visualized complex flow patterns, such as vortices and flow jets around the lesion. CONCLUSIONS: Our study findings demonstrate that the transrectal CE-UroVPI system developed in this study can effectively image fluid-structural interactions in the urethra. This new diagnostic technology has the potential to facilitate quantitative and precise assessments of urethral voiding functions and aid in the improvement of focal and effective treatments for patients with LUTS.


Asunto(s)
Próstata , Uretra , Humanos , Masculino , Uretra/diagnóstico por imagen , Uretra/patología , Proyectos Piloto , Ultrasonografía , Próstata/diagnóstico por imagen , Resultado del Tratamiento
13.
Ultrasonics ; 129: 106907, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36495767

RESUMEN

Observing alterations in cutaneous vasculature in response to any disease or pathology is considered as a potential diagnostic marker in the progression and cure of a disease. To observe skin morphologies and tissue conditions, high-frequency ultrasound (HFUS) has been used in dermatology, although its ability to selectively visualize micro-vessels is limited due to insufficient Doppler sensitivity to peripheral slow-speed blood flow. In recent studies, this issue has been improved by increasing the sensitivity of Doppler imaging to slow flow, leveraging advanced cutter filtering approaches based on singular value decomposition (SVD) techniques that aid to effectively extract flow signals overlapped with tissue echo signals. Nevertheless, in skin imaging, variations in flow speed, diameter, and depth of the blood vessels at different skin layers can make clutter filtering challenging because these variations are problematic in selecting the optimal cut-off value for the SVD filtering. In this study, we aimed to devise a novel region-based SVD filtering approach for ultrafast HFUS data to visualize cutaneous vascular networks. The proposed method divides the acquired high-framerate data into two regions based on B-mode cutaneous morphological identification (dermis layer and subcutaneous tissue). Singular value decomposition processing was performed on each region to effectively extract the desired flow signal, and the processed regions were merged to generate a single power Doppler image, thereby highlighting the appearance of a complete cutaneous vascular network. Finally, top-hat transform was applied to the power Doppler image to further suppress the background noises and enhances the visibility of the micro-vessels. Experimental observations of the human cutaneous circulation showed that the image quality (contrast-to-noise ratio) through the region-based SVD filtering was measured to be 4.1 dB (before top-hat filtering) and 5.2 dB (after top-hat filtering), which were improved from 3.4 dB and 4.0 dB obtained using the global SVD approach with and without top-hat filtering, respectively. We envisioned that this approach would provide diverse applications in the diagnosis of cutaneous disorders.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Procesamiento de Señales Asistido por Computador , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Velocidad del Flujo Sanguíneo/fisiología , Fantasmas de Imagen , Ultrasonografía/métodos , Ultrasonografía Doppler/métodos
14.
IEEE Trans Ultrason Ferroelectr Freq Control ; 70(12): 1631-1641, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37141063

RESUMEN

We address the problem of limited temporal resolution in optical-resolution microscopy (OR-PAM) for cellular imaging by undersampling and reconstruction. A curvelet transform method in a compressed sensing framework (CS-CVT) was devised to specifically reconstruct the boundary and separability of cell objects in an image. The performance of the CS-CVT approach was justified by comparisons with the natural neighbor interpolation (NNI) followed by smoothing filters on various imaging objects. In addition, a full-raster scanned image was provided as a reference. In terms of structure, CS-CVT produces cellular images with a smoother boundary but less aberration. We found the strength of CS-CVT in recovering high frequency that is important in representing sharp edges which often missing in typical smoothing filters. In a noisy environment, CS-CVT was less affected by the noise compared to NNI with a smoothing filter. Furthermore, CS-CVT could attenuate noise beyond the full raster scanned image. By considering the finest structure in the cellular image, CS-CVT was performing well with a minimum range of undersampling around 5% to 15%. In practice, this undersampling was easily translated into 8- to 4-fold faster OR-PAM imaging. In summary, our approach improves the temporal resolution of OR-PAM without a significant tradeoff in image quality.

15.
J Orthop Res ; 41(5): 951-961, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36031592

RESUMEN

Joint immobilization, which ensures rest and accelerates tissue recovery in musculoskeletal disorders, often causes joint contracture, for which there is still no effective prevention. To address this, we investigated the effects of extracorporeal shockwave therapy (ESWT) in preventing joint contracture, in a unilaterally immobilized knee rat model. Under general anesthesia, ESWT (0.25 mJ/mm2 , 3000 shot, 4 Hz, 3 days/week) was administered from 1 day after immobilization up to 2, 4, and 6 weeks. The immobilized control group received general anesthesia without ESWT. We evaluated joint angle, tissue elasticity, and gene and protein expression related to fibrosis, inflammation, and angiogenesis in the joint capsule. Relative to the control, the ESWT group had greater joint angle at 4 and 6 weeks, and lower posterior-capsule elasticity at 6 weeks. In the ESWT group, at 6 weeks, gene expression of collagen type I (col1α1), connective tissue growth factor (CTGF), and α-smooth muscle actin (α-SMA) was significantly downregulated, whereas interleukin-6 (IL-6) and hypoxia-inducible factor-1α (HIF-1α) gene expression was upregulated, relative to that in the control. Compared with that in the control, at 4 and 6 weeks, the ratio of CTGF+ cells was significantly lower in the ESWT group; at 4 weeks, the ESWT group had significantly fewer CD68+ cells in the adhesion area, and at 6 weeks, significantly more blood vessels. Statement of Clinical Significance: In a rat model, ESWT counteracted fibrosis, suppressed macrophage infiltration, and promoted neovascularization, reducing elasticity, and increasing joint range-ofmotion. ESWT offers a potential new strategy to prevent progression in joint contracture.


Asunto(s)
Contractura , Tratamiento con Ondas de Choque Extracorpóreas , Ratas , Animales , Articulación de la Rodilla/patología , Cápsula Articular/patología , Contractura/prevención & control , Contractura/metabolismo , Fibrosis
16.
J Artif Organs ; 15(1): 49-56, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21956206

RESUMEN

The purpose of this study was to examine the hemodynamic characteristics of expanded polytetrafluoroethylene (ePTFE) pulmonary valves with bulging sinuses quantitatively in a pediatric pulmonary mechanical circulatory system designed by us, in order to propose the optimal design for clinical applications. In this study, we developed a pediatric pulmonary mock circulation system, which consisted of a pneumatic right ventricular model, a pulmonary heart valve chamber, and a pulmonary elastic compliance tubing with resistive units. The hemodynamic characteristics of four different types of ePTFE valves and a monoleaflet mechanical heart valve were examined. Relationships between the leaflet movements and fluid characteristics were evaluated based on engineering analyses using echocardiography and a high-speed video camera under the pediatric circulatory conditions of the mock system. We successfully performed hemodynamic simulations in our pediatric pulmonary circulatory system that could be useful for quantitatively evaluating the pediatric heart valves. In the simulation study, the ePTFE valve with bulging sinuses exhibited a large eddy in the vicinity of the leaflets, whereas the straight tubing exhibited turbulent flow. The Reynolds number obtained in the valve with bulging sinuses was calculated to be 1667, which was smaller than that in the straight tubing (R (e) = 2454).The hemodynamic characteristics of ePTFE pediatric pulmonary heart valves were examined in our mock circulatory system. The presence of the bulging sinuses in the pulmonary heart valve decreased the hydrodynamic energy loss and increased the systolic opening area. Based on an in vitro experiment, we were able to propose an optimal selection of pulmonary valve design parameters that could yield a more sophisticated pediatric ePTFE valve shape.


Asunto(s)
Prótesis Valvulares Cardíacas , Corazón/fisiología , Hemodinámica/fisiología , Modelos Cardiovasculares , Niño , Humanos , Ensayo de Materiales , Politetrafluoroetileno , Flujo Pulsátil/fisiología
17.
Int Orthop ; 36(1): 185-90, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-21567149

RESUMEN

PURPOSE: The purpose of this study was to compare images of a newly developed high-frequency ultrasound imaging system (HFUIS) and scanning acoustic microscope (SAM) and to calculate their Pearson product moment correlations with a view to applying HFUIS for clinical use. METHODS: Cylindrical cartilage-bone complexes from adult male Sprague-Dawley rats were obtained. The specimens were immersed in normal saline and scanned by HFUIS. Intensity by HFUIS was normalised by reflection from a steel plate at the same distance. After the scanning, specimens were fixed with paraformaldehyde, decalcified and embedded in paraffin. Thinly sliced tissues were prepared for SAM evaluation. After the scanning, three layers of articular cartilage (superficial, middle and deep) were independently evaluated and their relationships calculated. RESULTS: The superficial and deep layers indicated high relative intensity, whereas the middle layer showed nonhomogeneous relative intensity by HFUIS. A high relative intensity by HFUIS and high sound speed area by SAM had strong correlations (Pearson product moment correlation, superficial layer 0.704, middle layer 0.731). CONCLUSIONS: HFUIS produced high-resolution images of the articular cartilage and its intensity was strongly correlated with sound speed by SAM.


Asunto(s)
Cartílago Articular/ultraestructura , Microscopía/métodos , Acústica , Animales , Cartílago Articular/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador , Masculino , Microscopía/instrumentación , Microscopía Electrónica de Rastreo , Ratas , Ratas Sprague-Dawley , Ultrasonido , Ultrasonografía
18.
J Med Ultrason (2001) ; 49(2): 163-173, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35229246

RESUMEN

PURPOSE: Tissue elasticity can be measured and mapped using color Doppler elastography. In a previous study, a binary pattern of shear waves was observed using a color flow imaging (CFI) system with matched pulse Doppler packet size as well as shear wave frequency and displacement condition. In the present study, we demonstrate the possibility of mapping shear wave velocity and resolving phantom elasticity using any commercial ultrasound machine without fulfilling that condition. METHODS: We derive a relation between Doppler autocorrelator integration time and the estimated flow velocity. The underlying principles behind the shear wave shadows captured by a typical modern ultrasound machine are investigated. The ultrasound machine measurement preset is calibrated to remove the effect of transducer array scanning delay in modifying the appearing wavenumber and thus correct the measurement error. RESULTS: The method was used to successfully measure the elasticity of a biological tissue-mimicking phantom and distinguish a stiff phantom from a soft phantom. CONCLUSION: Using this method, the elasticity of a biological tissue-mimicking phantom can be recovered with less strict constraint. As a result, it provides more flexibility to be implemented in common ultrasound machines. This method may be practically used to help identify tissue stiffness-related disease.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Elasticidad , Diagnóstico por Imagen de Elasticidad/métodos , Humanos , Fantasmas de Imagen , Transductores , Ultrasonografía
19.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 190-193, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-36086264

RESUMEN

Visualization of cutaneous micro-vasculatures is a determined approach in the diagnosis of skin vascular disorders. Clinically, high frequency ultrasound (HFUS) modalities have been used for cutaneous morphological and structural imaging, but visualization of micro-vessels has always been remained a daunting task. These tiny structures might be visualized by devising a highly sensitive Doppler technique for HFUS systems. In this study, we proposed an imaging framework using HFUS (30 MHz) ultrafast Doppler imaging along with SVD clutter filtering that is proficient in detection of micro-scale circulation. The performance of the devised framework was examined on a 200-micron flow phantom made of poly-vinyl alcohol under four different flow rates (56 - 18 ul/min) and visualized the micro-structure with averaged detected diameter of 93 - 170 µm. The results indicated that the devised framework has sufficient sensitivity and resolvability to visualize the micro-vasculatures in dermis layer of skin (depth ≤ 4 mm). Clinical Relevance - This study brings an insight to visualize in-vivo cutaneous micro-vasculatures with ultrafast Doppler imaging in clinical applications for better assessment of cutaneous disorders.


Asunto(s)
Ultrasonografía Doppler , Fantasmas de Imagen , Ultrasonografía , Ultrasonografía Doppler/métodos
20.
Sci Rep ; 12(1): 9221, 2022 06 02.
Artículo en Inglés | MEDLINE | ID: mdl-35654947

RESUMEN

Optical resolution photoacoustic microscopy (OR-PAM) is a remarkable biomedical imaging technique that can selectively visualize microtissues with optical-dependent high resolution. However, traditional OR-PAM using mechanical stages provides slow imaging speed, making it difficult to biologically interpret in vivo tissue. In this study, we developed a high-speed OR-PAM using a recently commercialized MEMS mirror. This system (MEMS-OR-PAM) consists of a 1-axis MEMS mirror and a mechanical stage. Furthermore, this study proposes a novel calibration method that quickly removes the spatial distortion caused by fast MEMS scanning. The proposed calibration method can easily correct distortions caused by both the scan geometry of the MEMS mirror and its nonlinear motion by running an image sequence only once using a ruler target. The combination of MEMS-OR-PAM and distortion correction method was verified using three experiments: (1) leaf skeleton phantom imaging to test the distortion correction efficacy; (2) spatial resolution and depth of field (DOF) measurement for system performance; (3) in-vivo finger capillary imaging to verify their biomedical use. The results showed that the combination could achieve a high-speed (32 s in 2 × 4 mm) and high lateral resolution (~ 6 µm) imaging capability and precisely visualize the circulating structure of the finger capillaries.


Asunto(s)
Sistemas Microelectromecánicos , Técnicas Fotoacústicas , Capilares , Microscopía/métodos , Técnicas Fotoacústicas/métodos , Análisis Espectral
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA