Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
J Appl Clin Med Phys ; 25(7): e14383, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38801204

RESUMEN

OBJECTIVE: To assess the impact of scatter radiation on quantitative performance of first and second-generation dual-layer spectral computed tomography (DLCT) systems. METHOD: A phantom with two iodine inserts (1 and 2 mg/mL) configured to intentionally introduce high scattering conditions was scanned with a first- and second-generation DLCT. Collimation widths (maximum of 4 cm for first generation and 8 cm for second generation) and radiation dose levels were varied. To evaluate the performance of both systems, the mean CT numbers of virtual monoenergetic images (MonoEs) at different energies were calculated and compared to expected values. MonoEs at 50  versus 150 keV were plotted to assess material characterization of both DLCTs. Additionally, iodine concentrations were determined, plotted, and compared against expected values. For each experimental scenario, absolute errors were reported. RESULTS: An experimental setup, including a phantom design, was successfully implemented to simulate high scatter radiation imaging conditions. Both CT scanners illustrated high spectral accuracy for small collimation widths (1 and 2 cm). With increased collimation (4 cm), the second-generation DLCT outperformed the earlier DLCT system. Further, the spectral performance of the second-generation DLCT at an 8 cm collimation width was comparable to a 4 cm collimation on the first-generation DLCT. A comparison of the absolute errors between both systems at lower energy MonoEs illustrates that, for the same acquisition parameters, the second-generation DLCT generated results with decreased errors. Similarly, the maximum error in iodine quantification was less with second-generation DLCT (0.45  and 0.33 mg/mL for the first and second-generation DLCT, respectively). CONCLUSION: The implementation of a two-dimensional anti-scatter grid in the second-generation DLCT improves the spectral quantification performance. In the clinical routine, this improvement may enable additional clinical benefits, for example, in lung imaging.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Fantasmas de Imagen , Dispersión de Radiación , Tomografía Computarizada por Rayos X , Humanos , Tomografía Computarizada por Rayos X/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos
2.
Biol Pharm Bull ; 46(6): 781-787, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37258142

RESUMEN

Anti-inflammatory and analgesic medications (AAMs) are widely used in Mexico and the rest of the world. Their excessive acquisition can lead to waste, representing an unnecessary expense for families and the public health system. The aim of this study was to estimate the economic cost of the waste of unused AAMs collected by the National System for the Collection of Residues of Containers and Medications (SINGREM, the acronym in Spanish) in Mexico City during 2019. Data from SINGREM on discarded AAMs in Mexico City were classified by the type and quantity of drug, pharmaceutical dosage form, origin, dose, and the complete or incomplete condition of the package. The unitary cost for each medication was based on public tenders of the Mexican Social Security Institute (IMSS) for the public sector and the prices in large drug store franchises for the private sector. A decision-making model was constructed to appraise the total cost of discarded AAMs. The economic cost of the 48924 units of discarded AAMs in SINGREM containers in Mexico City during 2019 was approx. USD$143500, of which over USD$127000 corresponded to the private health sector. The current findings evidence an enormous accumulation of unneeded or expired AAMs in Mexico City. According to the present data, the cost of such waste is substantial. The estimated cost was 8-fold higher for discarded medications originating from the private versus the public healthcare sector. It is important to implement measures to prevent this waste and increase awareness of the consequences of inadequate drug disposal.


Asunto(s)
Analgésicos , Atención a la Salud , Humanos , México , Analgésicos/uso terapéutico , Antiinflamatorios
3.
Opt Express ; 30(9): 15211-15226, 2022 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-35473248

RESUMEN

Compton backscattering imaging (CBI) is a technique that uses ionizing radiation to detect the presence of low atomic number materials on a given target. Unlike transmission x-ray imaging, the source and sensor are located on the same side, such that the photons of interest are scattered back after the radiation impinges on the body. Rather than scanning the target pixel by pixel with a pencil-beam, this paper proposes the use of cone-beam coded illumination to create the compressive x-ray Compton backscattering imager (CXBI). The concept was developed and tested using Montecarlo simulations through the Geant4 application for tomography emissions (GATE), with conditions close to the ones encountered in experiments, and posteriorly, a test-bed implementation was mounted in the laboratory. The CXBI was evaluated under several conditions and with different materials as target. Reconstructions were run using denoising-prior-based inverse problem algorithms. Finally, a preliminary dose analysis was done to evaluate the viability of CXBI for human scanning.


Asunto(s)
Algoritmos , Fotones , Humanos , Tomografía Computarizada por Rayos X/métodos , Rayos X
4.
J Comput Assist Tomogr ; 46(2): 224-230, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35081601

RESUMEN

OBJECTIVE: This study aimed to evaluate distal triceps tendon tear patterns using a systematic classification based on the tendon's layered structure. METHODS: We retrospectively identified Magnetic resonance imaging (MRI) examinations with triceps tendon tears that underwent reconstructive surgery. Magnetic resonance images were reviewed independently by 2 musculoskeletal radiologists to determine tendon layer involvement and ancillary findings, including tear size, involvement of triceps lateral expansion, and presence of olecranon bursal fluid. Surgical reports were scrutinized for level of anatomic detail and correlation with imaging findings. RESULTS: We identified 69 triceps tendon tears in 68 subjects (61 men, 7 women; mean age, 45 ± 12 years) who underwent surgical reconstruction. On MRI, the superficial layer was always involved with either a partial or full-thickness tear. The most common tear pattern was a combination of superficial layer full-thickness tear with deep layer partial tear (25 of 69 [36%]). Mean tear length was 24 ± 12 mm. We found no cases of isolated deep layer tears. Involvement of triceps lateral expansion and presence of bursal fluid correlated positively with tear severity of superficial and deep layers (P < 0.001). Detailed surgical correlation was limited, with only 9 of 69 (13%) of surgical reports containing information specifically addressing individual tendon layers. CONCLUSIONS: Triceps tendon tears show tear patterns following its layered structure and can be assessed by MRI. Radiologists and surgeons are encouraged to describe tear patterns considering both superficial and deep tendon layers.


Asunto(s)
Articulación del Codo , Lesiones del Manguito de los Rotadores , Adulto , Femenino , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Rotura/diagnóstico por imagen , Tendones/diagnóstico por imagen
5.
Skeletal Radiol ; 50(1): 97-106, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32638058

RESUMEN

OBJECTIVE: To examine the effect of external hip rotation on ischiofemoral (IF) and quadratus femoris (QF) spaces using real-time kinematic MRI, with the hypothesis that hips with IF and QF space narrowing have distinct motion patterns compared with control hips. MATERIALS AND METHODS: This prospective study was IRB-approved and complied with HIPAA guidelines. We recruited women (≥ 18 years) with and without ischiofemoral impingement to undergo kinematic MRI of the hips. A kinematic imaging protocol using T2-HASTE was performed beginning at maximal internal rotation followed by active external hip rotation. The duration of each acquisition was 30 s, providing 8 images/3 s. IF and QF spaces, and femoral metaphyseal and lesser trochanter centroid coordinates were measured on sequential images. Hips were classified as controls or narrowed based on IF and QF space thresholds and compared statistically throughout motion stages. RESULTS: The cohort comprised 12 women (24 hips; 10 control and 14 narrowed hips) aged 58 ± 10 years. External rotation caused IF space reduction of 59% in narrowed hips versus 41% in control hips. QF space decreased 71% in narrowed hips versus 50% in control hips. IF and QF spaces differed significantly between groups only when external rotation exceeded the neutral position (P < 0.02 for both). The lesser trochanter terminated more posteriorly in narrowed hips compared with controls (P = 0.03). CONCLUSIONS: Kinematic MRI during external hip rotation in women with narrowed and control hips reveals dynamic differences in IF and QF spaces and lesser trochanter terminal position.


Asunto(s)
Pinzamiento Femoroacetabular , Imagen por Resonancia Magnética , Fenómenos Biomecánicos , Femenino , Fémur/diagnóstico por imagen , Articulación de la Cadera/diagnóstico por imagen , Humanos , Estudios Prospectivos
6.
Molecules ; 26(8)2021 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-33917871

RESUMEN

Indazole is an important scaffold in medicinal chemistry. At present, the progress on synthetic methodologies has allowed the preparation of several new indazole derivatives with interesting pharmacological properties. Particularly, the antiprotozoal activity of indazole derivatives have been recently reported. Herein, a series of 22 indazole derivatives was synthesized and studied as antiprotozoals. The 2-phenyl-2H-indazole scaffold was accessed by a one-pot procedure, which includes a combination of ultrasound synthesis under neat conditions as well as Cadogan's cyclization. Moreover, some compounds were derivatized to have an appropriate set to provide structure-activity relationships (SAR) information. Whereas the antiprotozoal activity of six of these compounds against E. histolytica, G. intestinalis, and T. vaginalis had been previously reported, the activity of the additional 16 compounds was evaluated against these same protozoa. The biological assays revealed structural features that favor the antiprotozoal activity against the three protozoans tested, e.g., electron withdrawing groups at the 2-phenyl ring. It is important to mention that the indazole derivatives possess strong antiprotozoal activity and are also characterized by a continuous SAR.


Asunto(s)
Antiprotozoarios/síntesis química , Antiprotozoarios/farmacología , Quimioinformática , Indazoles/síntesis química , Indazoles/farmacología , Antiprotozoarios/química , Entamoeba histolytica/efectos de los fármacos , Giardia lamblia/efectos de los fármacos , Indazoles/química , Concentración 50 Inhibidora , Pruebas de Sensibilidad Parasitaria , Relación Estructura-Actividad , Trichomonas vaginalis/efectos de los fármacos , Ultrasonido
7.
Skeletal Radiol ; 48(3): 413-419, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30215105

RESUMEN

OBJECTIVE: To determine the role of brown adipose tissue (BAT) in cancer activity. MATERIALS AND METHODS: The study group comprised 142 patients (121 female, 21 male; mean age, 49 ± 16 years) who underwent F18-FDG PET/CT (PET/CT) for staging or surveillance of cancer and who were BAT-positive on PET/CT. BAT volume by PET/CT, abdominal (visceral and subcutaneous) fat and paraspinous muscle cross-sectional areas (CSA) were assessed. Groups with and without active cancer on PET/CT were compared using a two-sided paired t test. Linear regression analyses between BAT and body composition parameters were performed. RESULTS: There were 62 patients (54 female, eight male) who had active cancer on PET/CT and 80 patients (67 female, 13 male) without active cancer. Groups were similar in age and BMI (p ≥ 0.4), abdominal fat and muscle CSA, fasting glucose, and outside temperature at time of scan (p ≥ 0.2). Patients who had active cancer on PET/CT had higher BAT volume compared to patients without active cancer (p = 0.009). In patients without active cancer, BAT was positively associated with BMI and abdominal fat depots (r = 0.46 to r = 0.59, p < 0.0001) while there were no such associations in patients with active cancer (p ≥ 0.1). No associations between BAT and age or muscle CSA were found (p ≥ 0.1). CONCLUSIONS: BAT activity is greater in patients with active cancer compared to age-, sex-, and BMI-matched BAT-positive patients without active cancer, suggesting a possible role of BAT in cancer activity.


Asunto(s)
Tejido Adiposo Pardo/diagnóstico por imagen , Neoplasias/diagnóstico por imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones , Tejido Adiposo Pardo/patología , Adulto , Anciano , Anciano de 80 o más Años , Composición Corporal , Femenino , Fluorodesoxiglucosa F18 , Humanos , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias , Neoplasias/patología , Radiofármacos , Estudios Retrospectivos
8.
Acta Radiol ; 59(10): 1203-1209, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-29444586

RESUMEN

Background Recent studies suggest that pericardial adipose tissue (PAT) is associated with whole body adiposity and insulin resistance. Moreover, the incidence of cardiovascular disease (CVD) differs between men and women. Although CVD is more prevalent in men, women suffering from CVD have a higher mortality compared to men. Differences in PAT may account for some of the observed sex differences in manifestations of CVD. Purpose To assess pericardial adipose tissue (PAT) as a biomarker for cardiometabolic risk and to assess potential sex differences. Material and Methods We studied 303 individuals (151 women, 152 men; mean age = 57 ± 17 years) across the weight spectrum. PAT and abdominal adipose tissue were quantified using clinical computed tomography (CT) scans obtained as part of a positron emission tomography (PET)/CT. Cardiometabolic risk factors were assessed from medical records. Linear regression and receiver operating characteristic (ROC) curve analyses were performed to evaluate associations between PAT and cardiometabolic risk. Results PAT was higher in overweight and obese individuals compared to lean individuals and higher in men compared to women. PAT was positively associated with body mass index, abdominal fat ( P < 0.0001), fasting glucose, and serum lipids ( P < 0.05) with stronger associations in women than in men. PAT was accurate in detecting the prevalence of the metabolic syndrome with 74% sensitivity and 76% specificity (AUC = 0.80). Conclusion PAT is associated with measures of cardiometabolic risk and these associations are stronger in women compared to men. PAT could serve as a biomarker for opportunistic screening for cardiometabolic risk in patients undergoing chest CT.


Asunto(s)
Tejido Adiposo/diagnóstico por imagen , Síndrome Metabólico/epidemiología , Pericardio/diagnóstico por imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Biomarcadores , Enfermedades Cardiovasculares/diagnóstico por imagen , Femenino , Fluorodesoxiglucosa F18 , Humanos , Resistencia a la Insulina , Masculino , Persona de Mediana Edad , Obesidad , Sobrepeso , Prevalencia , Radiofármacos , Estudios Retrospectivos , Factores de Riesgo , Sensibilidad y Especificidad , Factores Sexuales
9.
Skeletal Radiol ; 47(5): 747-750, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29285554

RESUMEN

Triggering of the toes is rare, with isolated cases reported in the literature involving predominantly the flexor hallucis longus (FHL) tendon, a condition known as "hallux saltans" (HS). We report the dynamic sonographic findings of a 42-year-old female with a 2-month history of ankle pain and triggering of right hallux, consistent with HS. Sonography demonstrated tenosynovitis and focal thickening of FHL at the level of hindfoot, with a fibrous band adjacent to the tendon. Dynamic ultrasound showed triggering and snapping of FHL tendon during hallux flexion and extension, respectively. We present comprehensive documentation of this rare entity, including sonographic still images and cine clips, as well as correlation with arthroscopic surgical findings.


Asunto(s)
Hallux/diagnóstico por imagen , Atrapamiento del Tendón/diagnóstico por imagen , Dedos del Pie , Adulto , Artroscopía , Femenino , Hallux/cirugía , Humanos , Atrapamiento del Tendón/cirugía , Ultrasonografía
10.
Skeletal Radiol ; 47(8): 1127-1135, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-29426957

RESUMEN

OBJECTIVE: To evaluate the significance of biceps tendon (BT) displacement and peri-bicipital hematoma on MRI in subjects with pectoralis major (PM) tears. We hypothesized that these features might be associated with tear severity at surgery. MATERIALS AND METHODS: We retrospectively identified MRI cases with PM injury and reviewed clinical, imaging, and surgical records. MR images were reviewed independently by two musculoskeletal radiologists to determine anterior displacement of BT (BT-disp, in mm) and the presence of triangular-shaped peri-bicipital hematoma. Data were compared with an age- and sex-matched control group and correlated with surgical reports grouped by tear severity. RESULTS: We identified 46 subjects with PM injury (43 men, 3 women; mean age 34 ± 9 years), 26 of whom underwent surgical reconstruction, and 20 matched controls (P > 0.2). BT-disp was significantly higher in PM injury vs controls (P = 0.003), and in tendon vs myotendinous (MT) junction PM tears (P < 0.0001); however, MT junction tears vs controls were similar (P = 0.98). Higher BT-disp and presence of peri-bicipital hematoma correlated significantly with surgical reports describing full-thickness complete tears. BT-disp > 4.5 mm had 86% sensitivity and 75% specificity to detect the most severe tears on surgical reports, whereas the presence of peri-bicipital hematoma was the strongest predictor among both parameters. CONCLUSION: Anterior BT displacement and peri-bicipital hematoma are helpful indicators of full-thickness complete tears at the humeral insertion.


Asunto(s)
Músculos Pectorales/lesiones , Rotura/diagnóstico por imagen , Adulto , Traumatismos en Atletas/diagnóstico por imagen , Traumatismos en Atletas/etiología , Estudios de Casos y Controles , Femenino , Hematoma/diagnóstico por imagen , Hematoma/etiología , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Enfermedades Musculares/diagnóstico por imagen , Enfermedades Musculares/etiología , Músculos Pectorales/diagnóstico por imagen , Estudios Retrospectivos , Traumatismos de los Tendones/diagnóstico por imagen , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA