Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Arterioscler Thromb Vasc Biol ; 42(8): 1048-1059, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35770666

RESUMEN

BACKGROUND: Patients with thoracic aortopathy are at increased risk of catastrophic aortic dissection, carrying with it substantial mortality and morbidity. Although granular medial calcinosis (medial microcalcification) has been associated with thoracic aortopathy, its relationship to disease severity has yet to be established. METHODS: One hundred one thoracic aortic specimens were collected from 57 patients with thoracic aortopathy and 18 control subjects. Standardized histopathologic scores, immunohistochemistry, and nanoindentation (tissue elastic modulus) were compared with the extent of microcalcification on von Kossa histology and 18F-sodium fluoride autoradiography. RESULTS: Microcalcification content was higher in thoracic aortopathy samples with mild (n=28; 6.17 [2.71-10.39]; P≤0.00010) or moderate histopathologic degeneration (n=30; 3.74 [0.87-11.80]; P<0.042) compared with control samples (n=18; 0.79 [0.36-1.90]). Alkaline phosphatase (n=26; P=0.0019) and OPN (osteopontin; n=26; P=0.0045) staining were increased in tissue with early aortopathy. Increasingly severe histopathologic degeneration was related to reduced microcalcification (n=82; Spearman ρ, -0.51; P<0.0001)-a process closely linked with elastin loss (n=82; Spearman ρ, -0.43; P<0.0001) and lower tissue elastic modulus (n=28; Spearman ρ, 0.43; P=0.026).18F-sodium fluoride autoradiography demonstrated good correlation with histologically quantified microcalcification (n=66; r=0.76; P<0.001) and identified areas of focal weakness in vivo. CONCLUSIONS: Medial microcalcification is a marker of aortopathy, although progression to severe aortopathy is associated with loss of both elastin fibers and microcalcification.18F-sodium fluoride positron emission tomography quantifies medial microcalcification and is a feasible noninvasive imaging modality for identifying aortic wall disruption with major translational promise.


Asunto(s)
Calcinosis , Elastina , Aorta , Calcinosis/diagnóstico por imagen , Humanos , Índice de Severidad de la Enfermedad , Fluoruro de Sodio
2.
EuroIntervention ; 18(14): 1165-1177, 2023 Feb 20.
Artículo en Inglés | MEDLINE | ID: mdl-36534495

RESUMEN

BACKGROUND: Bioprosthetic valve fracture (BVF) can be used to improve transcatheter heart valve (THV) haemodynamics following a valve-in-valve (ViV) intervention. However, whether BVF should be performed before or after THV deployment and the implications on durability are unknown.  Aims: We sought to assess the impact of BVF timing on long-term THV durability. METHODS: The impact of BVF timing was assessed using small ACURATE neo (ACn) or 23 mm SAPIEN 3 (S3) THV deployed in 21 mm Mitroflow valves compared to no-BVF controls. Valves underwent accelerated wear testing up to 200 million (M) cycles (equivalent to 5 years). At 200M cycles, THV were evaluated by hydrodynamic testing, second-harmonic generation (SHG) microscopy, scanning electron microscopy (SEM) and histology. RESULTS: At 200M cycles, the regurgitant fraction (RF) and effective orifice area (EOA) for the ACn were 8.03±0.30%/1.74±0.01 cm2 (no BVF), 12.48±0.70%/1.97±0.02 cm2 (BVF before ViV) and 9.29±0.38%/2.21±0.0 cm2 (BVF after ViV), respectively. For the S3 these values were 2.63±0.51%/1.26±0.01 cm2, 2.03±0.42%/1.65±0.01 cm2, and 1.62±0.38%/2.22±0.01 cm2, respectively. Further, SHG and SEM revealed a higher degree of superficial leaflet damage when BVF was performed after ViV for the ACn and S3. However, the histological analysis revealed significantly less damage, as determined by matrix density analysis, through the entire leaflet thickness when BVF was performed after ViV with the S3 and a similar but non-significant trend with the ACn.  Conclusions: BVF performed after ViV appears to offer superior long-term EOA without increased RF. Ultrastructure leaflet analysis reveals that the timing of BVF can differentially impact leaflets, with more superficial damage but greater preservation of overall leaflet structure when BVF is performed after ViV.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Diseño de Prótesis , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento
3.
JACC Case Rep ; 2(4): 528-532, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34317286

RESUMEN

Post-explant (ex vivo) evaluation of medical devices is an essential part of quality assurance, quality improvement, and further device development. Central to this is detailed pathological analysis. Here, we provide the first such evaluation of an explanted Tiara transcatheter mitral valve prosthesis. (Level of Difficulty: Advanced.).

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA