Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Asunto de la revista
Intervalo de año de publicación
1.
Catheter Cardiovasc Interv ; 93(2): 324-329, 2019 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-30351525

RESUMEN

OBJECTIVES: To describe a multicenter experience of percutaneous transcatheter pulmonary valve replacement (TPVR) using the Edwards SAPIEN S3 valve without the use of a prior stent ("pre-stenting"). BACKGROUND: The SAPIEN S3 and XT valves have durable cobalt-chromium stent frames which may allow for TPVR in large diameter dysfunctional right ventricular outflow tracts (RVOTs) without pre-stenting the landing zone. METHODS: A retrospective review was performed of all patients with Congenital Heart Disease and dysfunctional RVOT who underwent TPVR using the SAPIEN valve without the use of a pre-stent. Imaging data, procedural elements, and clinical follow-up data were collected to evaluate short and intermediate-term results. RESULTS: Fifty-seven patients underwent percutaneous placement of the SAPIEN valve in the pulmonary position without the use of pre-stenting. The anatomical substrate varied: native RVOTs (n = 41), conduits (n = 10), and bioprosthetic valves (n = 6). There were no cases in which the valve could not be implanted and no cases of valve embolization or misplacement. On follow-up (range 1 month to 2.2 years, median 5.3 months), no patients had significant obstruction or regurgitation around the valve. There were no frame fractures. There were no procedural deaths. Major complications included severe aortic compression (n = 1) requiring surgical explantation and tricuspid valve injury requiring surgical intervention (n = 2). CONCLUSIONS: This limited multi-institutional experience demonstrates that the SAPIEN valve can be used for TPVR without the use of a pre-stent without medium-term risk of frame fracture, paravalvar leak, or embolization. Longer term follow-up is required to fully assess this method.


Asunto(s)
Cateterismo Cardíaco/instrumentación , Enfermedades de las Válvulas Cardíacas/cirugía , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Válvula Pulmonar/cirugía , Stents , Obstrucción del Flujo Ventricular Externo/cirugía , Adolescente , Adulto , Anciano , Cateterismo Cardíaco/efectos adversos , Niño , Preescolar , Femenino , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/fisiopatología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/fisiopatología , Recuperación de la Función , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos , Obstrucción del Flujo Ventricular Externo/diagnóstico por imagen , Obstrucción del Flujo Ventricular Externo/fisiopatología , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA