Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
AJR Am J Roentgenol ; 215(6): 1312-1320, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-33021835

RESUMEN

OBJECTIVE. The purpose of this study was to assess features of diffuse idiopathic pulmonary neuroendocrine cell hyperplasia (DIPNECH) on CT, clinical presentation, and delays in radiologic and clinical diagnosis in a series of 32 patients. MATERIALS AND METHODS. Medical records of patients with DIPNECH from the years 2000-2017 were obtained from an institutional data warehouse. Inclusion criteria were an available CT examination and either a pathologic diagnosis of DIPNECH or pathologic findings of multiple carcinoid tumorlets or carcinoid tumor with CT features suggesting DIPNECH. Two thoracic radiologists with 10 and 14 years of experience reviewed CT examinations and scored cases in consensus. RESULTS. All 32 patients were women, and most had never smoked (69%). The mean age at presentation was 61 years. Symptoms included chronic cough (59%) or dyspnea (28%), and the initial clinical diagnosis was asthma in 41%. DIPNECH was clinically suspected at presentation in only one case and was mentioned by the interpreting radiologist in only 31% of cases. CT characteristics included numerous nodules with a lower zone and peribronchiolar predominance, mosaic attenuation, and nodular bronchial wall thickening. Number of nodules at least 5 mm in diameter showed strong inverse correlations with the percentage predicted for both forced vital capacity and forced expiratory volume in 1 second and a moderate inverse correlation with total lung capacity percentage predicted. In cases with a follow-up CT interval of 3 years or longer, 85% of patients showed an increase in size of the largest nodule, and 70% had an increase in size in multiple nodules. CONCLUSION. Many cases of DIPNECH are originally missed or misdiagnosed by radiologists and clinicians. Awareness of the typical clinical and imaging features of DIPNECH may prompt earlier diagnosis of this condition.


Asunto(s)
Tumor Carcinoide/patología , Neoplasias Pulmonares/patología , Nódulos Pulmonares Múltiples/patología , Células Neuroendocrinas/patología , Tumores Neuroendocrinos/patología , Lesiones Precancerosas/patología , Tomografía Computarizada por Rayos X , Tumor Carcinoide/diagnóstico por imagen , Diagnóstico Tardío , Femenino , Humanos , Hiperplasia/patología , Neoplasias Pulmonares/diagnóstico por imagen , Persona de Mediana Edad , Nódulos Pulmonares Múltiples/diagnóstico por imagen , Tumores Neuroendocrinos/diagnóstico por imagen , Lesiones Precancerosas/diagnóstico por imagen
2.
J Comput Assist Tomogr ; 40(5): 763-72, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27331931

RESUMEN

BACKGROUND: Cardiac computed tomography (CT) image quality (IQ) is very important for accurate diagnosis. We propose to evaluate IQ expressed as Likert scale, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) from coronary CT angiography images acquired with a new volumetric single-beat CT scanner on consecutive patients and assess the IQ dependence on heart rate (HR) and body mass index (BMI). METHODS: We retrospectively analyzed the data of the first 439 consecutive patients (mean age, 55.13 [SD, 12.1] years; 51.47% male), who underwent noninvasive coronary CT angiography in a new single-beat volumetric CT scanner (Revolution CT) to evaluate chest pain at West Kendall Baptist Hospital. Based on patient BMI (mean, 29.43 [SD, 5.81] kg/m), the kVp (kilovolt potential) value and tube current were adjusted within a range of 80 to 140 kVp and 122 to 720 mA, respectively. Each scan was performed in a single-beat acquisition within 1 cardiac cycle, regardless of the HR. Motion correction software (SnapShot Freeze) was used for correcting motion artifacts in patients with higher HRs. Autogating was used to automatically acquire systolic and diastolic phases for higher HRs with electrocardiographic milliampere dose modulation. Image quality was assessed qualitatively by Likert scale and quantitatively by SNR and CNR for the 4 major vessels right coronary, left main, left anterior descending, and left circumflex arteries on axial and multiplanar reformatted images. Values for Likert scale were as follows: 1, nondiagnostic; 2, poor; 3, good; 4, very good; and 5, excellent. Signal-to-noise ratio and CNR were calculated from the average 2 CT attenuation values within regions of interest placed in the proximal left main and proximal right coronary artery. For contrast comparison, a region of interest was selected from left ventricular wall at midcavity level using a dedicated workstation. We divided patients in 2 groups related to the HR: less than or equal to 70 beats/min (bpm) and greater than 70 bpm and also analyzed them in 2 BMI groupings: BMI less than or equal to 30 kg/m and BMI greater than 30 kg/m. RESULTS: Mean SNR was 8.7 (SD, 3.1) (n = 349) for group with HR 70 bpm or less and 7.7 (SD, 2.4) (n = 78) for group with HR greater than 70 bpm (P = 0.008). Mean CNR was 6.9 (SD, 2.7) (n = 349) for group with HR 70 bpm or less and 5.9 (SD, 2.2) (n = 78) for group with HR 70 bpm or greater (P = 0.002). Mean SNR was 8.8 (SD, 3.2) (n = 249) for group with BMI 30 kg/m or less and 8.1 (SD, 2.6) (n = 176) for group with BMI greater than 30 kg/m (P = 0.008). Mean CNR was 7.0 (SD, 2.8) (n = 249) for group with BMI 30 kg/m or less and 6.4 (SD, 2.4) (n = 176) for group with BMI greater than 30 kg/m (P = 0.002). The results for mean Likert scale values were statistically different, reflecting difference in IQ between people with HR 70 bpm or less and greater than 70 bpm, BMI 30 kg/m or less, and BMI greater than 30 kg/m.


Asunto(s)
Técnicas de Imagen Sincronizada Cardíacas/instrumentación , Dolor en el Pecho/diagnóstico por imagen , Angiografía por Tomografía Computarizada/métodos , Angiografía Coronaria/instrumentación , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Imagenología Tridimensional/instrumentación , Índice de Masa Corporal , Enfermedad de la Arteria Coronaria/complicaciones , Diseño de Equipo , Análisis de Falla de Equipo , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
3.
BMC Res Notes ; 10(1): 681, 2017 Dec 04.
Artículo en Inglés | MEDLINE | ID: mdl-29202817

RESUMEN

BACKGROUND: Right atrial appendage aneurysms are rare entities that may have significant clinical consequences. When co-existing with atrial fibrillation, patients are at risk of developing pulmonary or paradoxical systemic emboli. CASE PRESENTATION: An elderly patient presented to medical attention with symptoms of acute diverticulitis. On abdominal computed tomography, a massively enlarged right atrial appendage aneurysm was discovered incidentally. The aneurysm caused marked compression of the right ventricle and contained an area of hypoenhancement concerning for an intraluminal thrombus. Gadolinium-enhanced cardiovascular magnetic resonance was performed and first-pass perfusion images demonstrated that the area of hypoenhancement was in fact poorly mixing blood. The patient was therefore managed medically. CONCLUSION: Right atrial appendage aneurysms are infrequently encountered cardiac abnormalities. In the literature, surgery has been offered to patients who are young, symptomatic, or have evidence of thrombotic disease, although whether this practice pattern is associated with superior clinical outcomes is unclear. In the present case, gadolinium-enhanced cardiovascular magnetic resonance imaging was used to exclude the presence of intraluminal thrombus in an elderly patient, which helped orient the patient's treating team towards medical-rather than surgical-therapy.


Asunto(s)
Dolor Abdominal/diagnóstico por imagen , Apéndice Atrial/diagnóstico por imagen , Diverticulitis/diagnóstico por imagen , Aneurisma Cardíaco/diagnóstico por imagen , Trombosis/diagnóstico por imagen , Dolor Abdominal/complicaciones , Dolor Abdominal/patología , Enfermedad Aguda , Anciano , Apéndice Atrial/patología , Diverticulitis/complicaciones , Diverticulitis/patología , Aneurisma Cardíaco/complicaciones , Aneurisma Cardíaco/patología , Humanos , Hallazgos Incidentales , Imagen por Resonancia Magnética , Trombosis/complicaciones , Trombosis/patología , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA