Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 281
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
Thorac Cardiovasc Surg ; 71(7): 557-565, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-36257545

RESUMEN

OBJECTIVES: The aim of this study was to investigate the need for postoperative permanent pacemaker implantation (PPI) following sutureless and rapid-deployment aortic valve replacement (SuRD-AVR) in the context of a progress report from a large multicenter international registry (SURD-IR). METHODS: We retrospectively analyzed 4,166 patients who underwent SuRD-AVR between 2008 and 2019. The primary outcome was the need for PPI before discharge. The study population was analyzed separately according to the implanted prostheses (Su cohort and RD cohort). Each cohort was divided into two groups based on the operation date: an early group ("EG" = 2008-2016) and a late group ("LG" = 2017-2019). RESULTS: The rate of PPI decreased significantly in the Su cohort over time (EG = 10.8% vs LG = 6.3%, p < 0.001). In the Su cohort, a decrease in age, risk profile, and incidence of bicuspid aortic valve, increased use of anterior right thoracotomy, reduction of cardiopulmonary bypass time and of associated procedures, and more frequent use of smaller prostheses were observed over time. In the RD cohort, the rate of PPI was stable over time (EG = 8.8% vs LG = 9.3%, p = 0.8). In this cohort, a younger age, lower risk profile, and higher incidence of concomitant septal myectomy were observed over time. CONCLUSION: Our analysis showed a significant decrease in the PPI rate in patients who underwent Su-AVR over time. Patient selection as well as surgical improvements and a more accurate sizing could be correlated with this phenomenon. The RD cohort revealed no significant differences either in patient's characteristics or in PPI rate between the two time periods.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Marcapaso Artificial , Procedimientos Quirúrgicos sin Sutura , Humanos , Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Estudios Retrospectivos , Informe de Investigación , Resultado del Tratamiento , Diseño de Prótesis , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Procedimientos Quirúrgicos sin Sutura/efectos adversos
2.
Perfusion ; 38(3): 449-454, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-34927474

RESUMEN

Metabolism management plays an essential role in extracorporeal technologies. There are different metabolic management devices integrated to extracorporeal devices; the most commonly used and accepted metabolic target in adult patients is indexed oxygen delivery (280 mL/min/m2) and cardiac index (2.4 L/min/m2), which can be managed independently or according to other metabolic parameters. Extracorporeal membrane oxygenation (ECMO) is a temporary form of life support providing a prolonged biventricular circulatory and pulmonary support for patients experiencing both pulmonary and cardiac failure unresponsive to conventional therapy. The goal-directed perfusion initiative during cardiopulmonary bypass (CPB) reduced the incidence of acute kidney injury after cardiac surgery. On the basis of the available literature, the identified goals to achieve during CPB include maintenance of oxygen delivery > 300 mL O2/min/m2 and reduction in vasopressor use. ECMO and CPB are conceptually similar but differ in many aspects and finality; in particular, they differ in the scientific evidence for metabolic management nadirs. As for CPB, predictive target parameters have been found and consolidated, particularly in terms of acute renal injury and the prevention of anaerobic metabolism, while for ECMO management, a blurred path remains. In this context, we review the strategies for optimal goal-directed therapy during CPB and ECMO, trying to transfer the knowledge and experience from daily cardiac surgery to veno-arterial ECMO.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Oxigenación por Membrana Extracorpórea , Adulto , Humanos , Objetivos , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Perfusión , Oxígeno , Estudios Retrospectivos
3.
JAMA ; 330(2): 141-151, 2023 07 11.
Artículo en Inglés | MEDLINE | ID: mdl-37326473

RESUMEN

Importance: Meropenem is a widely prescribed ß-lactam antibiotic. Meropenem exhibits maximum pharmacodynamic efficacy when given by continuous infusion to deliver constant drug levels above the minimal inhibitory concentration. Compared with intermittent administration, continuous administration of meropenem may improve clinical outcomes. Objective: To determine whether continuous administration of meropenem reduces a composite of mortality and emergence of pandrug-resistant or extensively drug-resistant bacteria compared with intermittent administration in critically ill patients with sepsis. Design, Setting, and Participants: A double-blind, randomized clinical trial enrolling critically ill patients with sepsis or septic shock who had been prescribed meropenem by their treating clinicians at 31 intensive care units of 26 hospitals in 4 countries (Croatia, Italy, Kazakhstan, and Russia). Patients were enrolled between June 5, 2018, and August 9, 2022, and the final 90-day follow-up was completed in November 2022. Interventions: Patients were randomized to receive an equal dose of the antibiotic meropenem by either continuous administration (n = 303) or intermittent administration (n = 304). Main Outcomes and Measures: The primary outcome was a composite of all-cause mortality and emergence of pandrug-resistant or extensively drug-resistant bacteria at day 28. There were 4 secondary outcomes, including days alive and free from antibiotics at day 28, days alive and free from the intensive care unit at day 28, and all-cause mortality at day 90. Seizures, allergic reactions, and mortality were recorded as adverse events. Results: All 607 patients (mean age, 64 [SD, 15] years; 203 were women [33%]) were included in the measurement of the 28-day primary outcome and completed the 90-day mortality follow-up. The majority (369 patients, 61%) had septic shock. The median time from hospital admission to randomization was 9 days (IQR, 3-17 days) and the median duration of meropenem therapy was 11 days (IQR, 6-17 days). Only 1 crossover event was recorded. The primary outcome occurred in 142 patients (47%) in the continuous administration group and in 149 patients (49%) in the intermittent administration group (relative risk, 0.96 [95% CI, 0.81-1.13], P = .60). Of the 4 secondary outcomes, none was statistically significant. No adverse events of seizures or allergic reactions related to the study drug were reported. At 90 days, mortality was 42% both in the continuous administration group (127 of 303 patients) and in the intermittent administration group (127 of 304 patients). Conclusions and Relevance: In critically ill patients with sepsis, compared with intermittent administration, the continuous administration of meropenem did not improve the composite outcome of mortality and emergence of pandrug-resistant or extensively drug-resistant bacteria at day 28. Trial Registration: ClinicalTrials.gov Identifier: NCT03452839.


Asunto(s)
Hipersensibilidad , Sepsis , Choque Séptico , Humanos , Femenino , Persona de Mediana Edad , Masculino , Meropenem/uso terapéutico , Choque Séptico/mortalidad , Enfermedad Crítica/terapia , Método Doble Ciego , Sepsis/complicaciones , Antibacterianos/efectos adversos , Antibacterianos/administración & dosificación , Monobactamas/uso terapéutico
4.
Surg Technol Int ; 422023 01 25.
Artículo en Inglés | MEDLINE | ID: mdl-36695598

RESUMEN

BACKGROUND: The results of recent studies regarding the efficacy of Negative Pressure Wound Therapy (NPWT) for the prevention of sternal wound infection (SWI) after adult cardiac surgery are not conclusive. METHODS: Data were collected from patients who were operated upon at the GVM Care & Research group in Italy from 2013 to 2021; all patients who required treatment for sternotomy wound infection with Negative Pressure Wound Therapy (NPWT) through WaterLily™ system (Eurosets, Medolla, MO, Italy) were selected. We compared the preoperative risk characteristics, and particularly those that were most strongly associated with possible dehiscence of the wound. A statistical analysis was performed for comparison of the groups. RESULTS: Out of the total 40,267 patients who underwent cardiac surgery with extracorporeal circulation within this time frame, 1,483 (3.68%) required NPWT, including 690 (46.52%) in the HOME group and 793 (53.47%) in the HOSPITAL group (p =0.76). Thirty-nine (5.65%) patients in the HOME group and 37 (4.66%) in the HOSPITAL group required re-treatment for re-dehiscence after secondary closure (p =0.79). CONCLUSIONS: The use of a WaterLily™ system (Eurosets, Medolla, MO, Italy) was safe and effective for the treatment of sternotomy wounds with superficial and deep infections and was associated with a low rate of dehiscence, even when used with discharged and managed outpatient patients.

5.
Heart Lung Circ ; 32(3): 387-394, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36566143

RESUMEN

AIM: The aim of this study was to assess the impact of surgeon experience and centre volume on early operative outcomes in patients undergoing off-pump coronary artery bypass (OPCAB) surgery. METHOD: Of 7,352 patients in the European Multicenter Study on Coronary Artery Bypass Grafting (E-CABG) registry, 1,549 underwent OPCAB and were included in the present analysis. Using adjusted regression analysis, we compared major early adverse events after procedures performed by experienced OPCAB surgeons (i.e., ≥20 cases per year; n=1,201) to those performed by non-OPCAB surgeons (n=348). Furthermore, the same end points were compared between procedures performed by OPCAB surgeons in high OPCAB volume centres (off-pump technique used in >50% of cases; n=894) and low OPCAB volume centres (n=307). RESULTS: In the experienced OPCAB surgeon group, we observed shorter procedure times (ß -43.858, 95% confidence interval [CI] -53.322 to -34.393; p<0.001), a lower rate of conversion to cardiopulmonary bypass (odds ratio [OR] 0.284, 95% CI 0.147-0.551; p<0.001), a lower rate of prolonged inotrope or vasoconstrictor use (OR 0.492, 95% CI 0.371-0.653; p<0.001), a lower rate of early postprocedural percutaneous coronary interventions (OR 0.335, 95% CI 0.169-0.663; p=0.002), and lower 30-day mortality (OR 0.423, 95% CI 0.194-0.924; p=0.031). In high OPCAB volume centres, we found a lower rate of prolonged inotrope use (OR 0.584, 95% CI 0.419-0.814; p=0.002), a lower rate of postprocedural acute kidney injury (OR 0.382, 95% CI 0.198-0.738; p=0.004), shorter duration of intensive care unit (ß -1.752, 95% CI -2.240 to -1.264; p<0.001) and hospital (ß -1.967; 95% CI -2.717 to -1.216; p<0.001) stays, and lower 30-day mortality (OR 0.316, 95% CI 0.114-0.881; p=0.028). CONCLUSIONS: Surgeon experience and centre volume may play an important role on the early outcomes after OPCAB surgery.


Asunto(s)
Puente de Arteria Coronaria Off-Pump , Cirujanos , Humanos , Puente de Arteria Coronaria Off-Pump/efectos adversos , Puente de Arteria Coronaria Off-Pump/métodos , Puente de Arteria Coronaria/efectos adversos , Puente de Arteria Coronaria/métodos , Factores de Tiempo , Sistema de Registros , Resultado del Tratamiento
6.
J Cardiothorac Vasc Anesth ; 36(8 Pt B): 3237-3243, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35094926

RESUMEN

Intraoperative temperature regimen usually is planned preoperatively by a "team." Selecting and understanding the impact of the temperature regimen (normothermia, or mild, moderate, or severe hypothermia) usually are related to the type of cardiac surgery (eg, using circulatory arrest or open-heart surgery). Cardiopulmonary bypass constitutes a challenging situation for monitoring temperature because of the rapid and extraordinary degree of heat transferred through the bypass circuit during heating and cooling. The core compartment undergoes the fastest temperature changes because of the rapid rate of blood reinfused into the organs. In modern cardiac surgery, different types and technologies of heater-cooler devices can be used in clinical practice, thanks to the development process that took its cue from past experiences. In this context, the authors review the role of thermal exchange in cardiac surgery and the progress achieved from first-to-second-generation heater-cooler devices.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Hipotermia Inducida , Cirugía Torácica , Puente Cardiopulmonar , Humanos , Temperatura
7.
J Cardiothorac Vasc Anesth ; 36(8 Pt A): 2636-2642, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-34417098

RESUMEN

Limited data are available on the use of the prone position in cardiac surgery. Concerns in performing this maneuver in open cardiac surgery due to the risk of post-sternotomy wound infections and hemodynamic instability do not seem to be supported by existing evidence. Indeed, available data show that prone positioning may improve gas exchange in cardiac surgery patients as well. However, previous studies of prone positioning in this setting were heterogeneous in patient characteristics and outcomes evaluated. As a result, whether prone positioning also may be effective in reducing mortality in patients with postoperative acute respiratory failure, particularly in those who underwent surgery under extracorporeal circulation, remains to be clearly elucidated. The aim of this article is to provide an overview of available literature, which seems to suggest the efficacy of prone positioning, and to make an in-depth analysis of the studies on this topic by evaluating the efficacy of this maneuver on hard endpoints.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Síndrome de Dificultad Respiratoria , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Humanos , Posicionamiento del Paciente , Periodo Posoperatorio , Posición Prona
8.
J Card Surg ; 37(10): 2958-2962, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34783083

RESUMEN

BACKGROUND AND AIM OF THE STUDY: The debate on the usefulness of the minimally invasive approach in mitral valve surgery is still open. The aim of this study is to describe a single-center case series of all comers undergoing minimally invasive mitral valve reconstruction. METHODS: From 2010 to 2019, all the data recorded in the medical records of 893 consecutive patients undergoing mitral valve reconstruction through a right mini-thoracotomy were retrospectively collected. All patients were contacted by telephone for remote evaluation and integration of echocardiographic information on surgical results. RESULTS: Mean age was 62.2 ± 14.5; 447 (50%) were female and mean log EuroSCORE was 2.5 ± 2.8%. At a mean follow-up of 4.1 ± 2.2 years (median 3.9), a total of 24 deaths (2.68%) were recorded. Twenty-four patients required rehospitalization for cardiac causes, 13 (1.4%) patients had at least moderate mitral insufficiency on follow-up echocardiography and, of these, seven patients underwent reoperation (0.8%). The cumulative hazard showed that 8.3% of patients experienced at least one event at 5 years. NYHA class improved significantly with 874 patients in NYHA class I, 13 in NYHA class II, 6 in NYHA class III, and 0 in NYHA class IV at last follow-up (p < .001 from baseline as reference point). CONCLUSIONS: In a high-volume center, mitral valve surgery using a minimally invasive approach is a feasible treatment option for all-comers and is associated with excellent results that are maintained at clinical and echocardiographic follow-up.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Anciano , Femenino , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Masculino , Persona de Mediana Edad , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/cirugía , Reoperación , Estudios Retrospectivos , Resultado del Tratamiento
9.
J Card Surg ; 37(12): 4517-4523, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36335612

RESUMEN

BACKGROUND: Length measurement of artificial chordae remains a critical step during mitral valve repair (MVr). The aim of this study is to assess the effectiveness of a new length measuring technique. METHODS: All consecutive patients with anterior leaflet prolapse/flail who underwent MVr using the described method between January 2020 and January 2022 at our institution were included in the analysis. Clinical and transesophageal echocardiography data were collected postoperatively and at 1-year follow-up. The primary outcome was freedom from mitral regurgitation (MR). Secondary outcomes were presentation with New York Heart Association (NYHA) class <2 and leaflet coaptation length ≥10 mm. RESULTS: Of 25 patients, 16 (64%) were males. A total of 15 (60%) had isolated anterior leaflet disease, while 10 (40%) had concomitant posterior involvement. Twenty patients with isolated MR (80%) underwent right anterior mini-thoracotomy, while 5 (20%) with associated valvular or coronary disease underwent sternotomy. The median number of chordae implanted was 2 [1-4]. Postrepair intraoperative MR grade was 0 in 23 patients (92%) and 1 in 2 (8%). Thirty-day mortality was 0%. De novo atrial fibrillation was 20%. At follow-up, mortality was 0%. No patients presented with moderate or severe MR. A total of 22 patients (88%) were in NYHA class I, while 3 (12%) in class II. The coaptation length was 11 ± 1 mm. CONCLUSIONS: The short-term outcomes of the described technique are good with adequate leaflet coaptation in all treated patients. Long-term results are needed to assess the stability and durability of this repair technique.


Asunto(s)
Anuloplastia de la Válvula Mitral , Insuficiencia de la Válvula Mitral , Prolapso de la Válvula Mitral , Masculino , Humanos , Femenino , Prolapso de la Válvula Mitral/diagnóstico por imagen , Prolapso de la Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Resultado del Tratamiento , Cuerdas Tendinosas/diagnóstico por imagen , Cuerdas Tendinosas/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Anuloplastia de la Válvula Mitral/métodos
10.
Perfusion ; 37(8): 765-772, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-34250858

RESUMEN

This article introduces management algorithms to support operators in choosing the best strategy for metabolic management during cardiopulmonary bypass using artificial intelligence systems. We developed algorithms for the identification of the optimal way for assessing metabolic parameters. Different management algorithms for extracorporeal procedures interfaced with metabolic monitoring systems already exist on the market and are applied in clinical practice. These algorithms could provide guidance for selecting the best metabolic strategy with the aim at reducing human error and optimizing management.


Asunto(s)
Inteligencia Artificial , Puente Cardiopulmonar , Humanos , Puente Cardiopulmonar/métodos , Algoritmos
11.
Heart Lung Circ ; 31(2): 263-271, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34330630

RESUMEN

BACKGROUND: Postoperative bleeding after cardiac surgery is associated with increased morbidity and mortality. We tested the hypothesis that patients with a preoperatively estimated high risk of severe perioperative bleeding may have impaired early outcome after on-pump versus off-pump coronary artery bypass grafting (CABG). METHOD: Data from 7,352 consecutive patients who underwent isolated CABG from January 2015 to May 2017 were included in the multicentre European Coronary Artery Bypass Grafting registry. The postoperative bleeding risk was estimated using the WILL-BLEED risk score. Of all included patients, 3,548 had an increased risk of severe perioperative bleeding (defined as a WILL-BLEED score ≥4) and were the subjects of this analysis. We compared the early outcomes between patients who underwent on-pump or off-pump CABG using a multivariate mixed model for risk-adjusted analysis. RESULTS: Off-pump surgery was performed in 721 patients (20.3%). On-pump patients received more packed red blood cell units (on-pump: 1.41 [95% confidence interval {CI} 0.99-1.86]; off-pump: 0.86 [95% CI 0.64-1.08]; p<0.001), had a longer stay in the intensive care unit (on-pump: 4.4 [95% CI 3.6-8.1] days; off-pump: 3.2 [95% CI 2.0-4.4] days; p=0.049), and a higher rate of postoperative atrial fibrillation (on-pump: 46.5% [95% CI 34.9-58.1]; off-pump: 31.3% [95% CI 21.7-40.9]; p=0.025). Furthermore, on-pump patients showed a trend towards a higher rate of postoperative stroke (on-pump: 2.4% [95% CI 0.9-4.1]; off-pump: 1.1 [95% CI 0.2-2.7]; p=0.094). CONCLUSION: Our data suggest that in patients with an increased risk of bleeding, the use of cardiopulmonary bypass is associated with higher morbidity. These patients may benefit from off-pump surgery if complete revascularisation can be ensured.


Asunto(s)
Fibrilación Atrial , Puente de Arteria Coronaria Off-Pump , Puente Cardiopulmonar , Puente de Arteria Coronaria/efectos adversos , Puente de Arteria Coronaria Off-Pump/efectos adversos , Humanos , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Estudios Retrospectivos , Resultado del Tratamiento
12.
Rev Cardiovasc Med ; 22(4): 1621-1627, 2021 Dec 22.
Artículo en Inglés | MEDLINE | ID: mdl-34957803

RESUMEN

The aim of this study is to describe a modified technique for aortic prosthesis implantation in the sinuses of Valsalva without the use of a patch for aortic annular reconstruction in patients with prosthetic valve endocarditis complicated by aortic abscess. From January 2008 to March 2021, 47 patients underwent aortic valve replacement due to prosthetic aortic valve endocarditis. The new aortic prosthesis was implanted into the sinuses of Valsalva above the abscess left open to drain. The first step consists in passing U-shaped stitches with pledgets through the aortic wall approximately 5-7 mm above the abscess involving the annulus. In the second step, the prosthesis is fixed to the aortic wall. In the third step, a 10 mm wide Teflon strip is positioned along the external course of the aortic wall and U-shaped stitches without pledgets are passed from the outside to the inside to definitively fix the prosthetic annulus to the sinuses of Valsalva. In-hospital mortality was 8.5% (4/47 patients). Mean follow-up was 62 ± 37.7 months. Four patients died (9.3%). Predicted probability of cardiac vs non-cardiac mortality was not statistically significant (p = 0.88). Overall survival probability (freedom from all-cause death) at 3, 7 and 9 years was 97%, 87.5% and 75%, respectively. No patients presented with grade 2 or 3 peri-prosthetic leak, nor had endocarditis. Prosthetic valve endocarditis complicated by complex paraannular aortic abscess can be successfully addressed with good long-term results by using our alternative technique.


Asunto(s)
Endocarditis Bacteriana , Endocarditis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Absceso/diagnóstico por imagen , Absceso/etiología , Absceso/cirugía , Endocarditis Bacteriana/diagnóstico , Endocarditis Bacteriana/diagnóstico por imagen , Prótesis Valvulares Cardíacas/efectos adversos , Humanos , Implantación de Prótesis/efectos adversos
13.
Perfusion ; 36(8): 781-785, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-33112217

RESUMEN

The inflammatory response in cardiac surgery using extracorporeal circulation (ECC) has been widely discussed in the literature with analysis on cytokines released in humans; demonstrating manifold trigger causes. To mitigate this response-mainly linked to the contact and recognition by the blood of a "non-self" surface-many efforts have been made to make the circuits of the extra-corporeal circulation "biomimetics"; trying to emulate the cardio-vascular system. In other words, biomedical companies have developed many biocompatible products in order to reduce the invasiveness of the ECC. One of the techniques used to reduce the contact of blood with "nonself" surfaces is the "coating" of the internal surfaces of the ECC. This can be done with phospholipidic, electrically neutral, and heparin derivates with anticoagulant activity. The coating can be divided into two categories: the "passive coating" with Phosphorylcholine by biomedical companies and the administration of albumin added to the "priming" during the filling of the circuit by the perfusionist. Alternatively, we have the "active" coating: treatment of the internal surfaces in contact with the blood with neutral proteins and heparin. The latter are different according to the production company, but the aim is always to maintain high levels of systemic and local anticoagulation, inactivating the "contact" coagulation between the blood and the surfaces. A recent study demonstrates that the use of an "active coating" is associated with better preservation of the endothelial glycocalyx compared with "passive coating" circuits.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Heparina , Coagulación Sanguínea , Circulación Extracorporea , Humanos , Inflamación
14.
J Card Surg ; 35(8): 2039-2040, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32652821

RESUMEN

Condensation and water loss from gas output of the cardiopulmonary bypass (CPB) oxygenator has been the study object of several research. However, little is known about the propagation of the condensation formed at the level of oxygenator and how potentially it can contaminate the surrounding environment. We aimed to document the moment of formation of the 'gas steam' derived from the CPB oxygenator during cardiac surgery with thermography imaging. Thermographic camera is a device that creates an image using infrared radiation, similar to a common camera that forms an image using visible light. The brightest (warmest) parts of the image are customarily colored white, the intermediate temperatures reds and yellows, and the dimmest (coolest) parts black. Thermal image captures the condensation phenomenon around the oxygenator perimeter with the same color/temperature code (yellow) of gas outlet. The use of aspiration at the level of the gas outlet could also favor the elimination of the condensation, improve gas exchanges, and potentially reduce the spread of hazardous substances in the operating room.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Puente Cardiopulmonar/instrumentación , Falla de Equipo , Oxigenadores , Agua , Quirófanos , Temperatura , Termografía , Volatilización
15.
J Card Surg ; 35(6): 1186-1194, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32349178

RESUMEN

BACKGROPUND AND AIM: Postoperative thrombocytopenia after surgical aortic valve replacement (SAVR) or transcatheter aortic valve replacement (TAVR) and aggravating causes were the aim of this retrospective study. METHODS: Data of all patients treated with SAVR (n = 1068) and TAVR (n = 816) due to severe aortic valve stenosis was collected at our center from 2010 to 2017. Preprocedural and postprocedural values were collected from electronic patient records. RESULTS: There was a significant drop in platelets in both groups, the TAVR group showed overall superior platelet preservation compared to the AVR group (P < .001). In the SAVR subgroup analysis, a significant difference in platelet preservation was observed between the valve types (P < .001), particularly with the Freedom SOLO valve. In the TAVR subgroup analysis, the valve type did not influence platelet count (PLT) reduction (P = .13). In the SAVR subgroup analyses, PLT was found to be worsened with cardiopulmonary bypass (CPB) duration. CONCLUSION: Thrombocytopenia frequently occurs after implantation of a biological heart valve prosthesis, with a higher frequency observed in patients after cardiac surgery rather than TAVR. Although some surgical bioprosthetic models are more susceptible to this phenomenon, CPB duration seems to be a major determinant for the development of postoperative thrombocytopenia.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Bioprótesis/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Prótesis Valvulares Cardíacas/efectos adversos , Complicaciones Posoperatorias/etiología , Trombocitopenia/etiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Anciano de 80 o más Años , Puente Cardiopulmonar/efectos adversos , Femenino , Humanos , Masculino , Complicaciones Posoperatorias/sangre , Complicaciones Posoperatorias/epidemiología , Estudios Retrospectivos , Factores de Riesgo , Trombocitopenia/sangre , Trombocitopenia/epidemiología , Factores de Tiempo
16.
J Card Surg ; 35(7): 1548-1555, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32490568

RESUMEN

BACKGROUND: The aim of this multicenter prospective study was to evaluate the prognostic weight of preoperative right ventricular assessment on early mortality in cardiac surgery. METHODS: This is a multicenter prospective observational study performed by the Italian Group of Research for Outcome in Cardiac Surgery (GIROC) including 11 centers. From October 2017 to March 2019, out of 923 patients undergoing cardiac surgery, 28 patients with some missing data were excluded and 895 patients were enrolled in the study right ventricular dilatation was defined as a basal end-diastolic diameter >42 mm. The right ventricle (RV) function was assessed using the combination of three parameters: fractional area changing (FAC), tricuspid annular plane systolic excursion (TAPSE), and S'-wave using tissue Doppler imaging (TDI-S'); RV dysfunction was defined as the presence of at least two of the following cutoffs: FAC <35%, TAPSE <17 mm, and TDI S' <9.5 mm RESULTS: Among the entire cohort, 624 (70%) showed normal RV, 92 (10%) isolated RV dilatation, 154 (17%) isolated RV dysfunction, and 25 (3%) both RV dilatation and dysfunction. Non-surviving patients showed a significantly higher rate of RV alteration at multivariable analysis, RV status was found to be an independent predictor for higher in-hospital mortality beside Euroscore II. CONCLUSIONS: This prospective multicenter observation study shows the importance to assess RV preoperatively and to include both RV function and dimension in a risk score model such as Euroscore II to implement its predictivity, since PH cannot always mirror the status of the right ventricle.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/mortalidad , Ventrículos Cardíacos/patología , Evaluación de Resultado en la Atención de Salud/métodos , Proyectos de Investigación , Función Ventricular Derecha , Adulto , Anciano , Anciano de 80 o más Años , Dilatación Patológica , Femenino , Humanos , Masculino , Persona de Mediana Edad , Periodo Preoperatorio , Pronóstico , Estudios Prospectivos , Riesgo , Disfunción Ventricular Derecha , Adulto Joven
17.
Heart Surg Forum ; 23(4): E475-E481, 2020 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-32726226

RESUMEN

BACKGROUND: Bilateral internal mammary artery (BIMA) grafting largely is underutilized in patients undergoing coronary artery bypass grafting (CABG), partly because of the perceived increased complexity of the procedure. AIMS: In this study, we evaluated whether BIMA grafting can safely be performed also in centers, where this revascularization strategy infrequently is adopted. METHODS: Out of 6,783 patients from the prospective multicenter E-CABG study, who underwent isolated non- emergent CABG from January 2015 to December 2016, 2,457 underwent BIMA grafting and their outcome was evaluated in this analysis. RESULTS: The mean number of BIMA grafting per center was 82 cases/year and hospitals were defined as high or low volume, according to this cutoff value. Six hospitals were considered as centers with a high volume of BIMA grafting (no. of procedures ranging from 120 to 267/year; overall: 2,156; prevalence: 62.2%) and nine hospitals as centers with a low volume of BIMA grafting (no. of procedures ranging from 2 to 39/year; overall: 301; prevalence: 9.1%). Multilevel mixed-effects regression analysis showed that the low- and high-volume cohorts had similar outcomes. Propensity score one-to-one matching analysis of 292 pairs showed that the low-volume cohort had a significantly shorter intensive care unit stay (2.2 ± 2.3 versus 2.9 ± 4.8 days, P = .020). The rates of in-hospital death (1.0% versus 0.3%, P = .625), deep sternal wound infection/mediastinitis (3.8% versus 3.1%, P = .824), and 1-year survival (98.1% versus 99.7%, P = .180) as well as other outcomes were similar between the high- and low-volume cohorts. CONCLUSIONS: BIMA grafting can be safely performed also in centers in which this revascularization strategy is infrequently performed.


Asunto(s)
Puente de Arteria Coronaria/métodos , Enfermedad de la Arteria Coronaria/cirugía , Hospitales/provisión & distribución , Arterias Mamarias/trasplante , Puntaje de Propensión , Anciano , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Factores de Riesgo
18.
Circ Res ; 120(11): 1800-1811, 2017 May 26.
Artículo en Inglés | MEDLINE | ID: mdl-28420669

RESUMEN

RATIONALE: The pathogenesis of bicuspid aortic valve (BAV)-associated aortopathy is poorly understood, and no prognostic biomarker is currently available. OBJECTIVE: We aimed to identify putative circulating biomarkers pathogenetically and prognostically linked to bicuspid aortopathy. METHODS AND RESULTS: By reverse transcription polymerase chain reaction, we evaluated gene expression variations (versus normal aorta) of transforming growth factor-ß1 (TGF-ß1), connective tissue growth factor, matrix metalloproteinase-2 (MMP-2), MMP-14, endoglin (ENG), and superoxide dismutase 3 in ascending aorta samples from 50 tricuspid and 70 patients with BAV undergoing surgery for aortic stenosis (aorta diameter ≤45 mm: BAVnon-dil or >45 mm: BAVdil). Expression changes of the TGF-ß1 active dimer and ENG were analyzed also by Western blot in ascending aorta samples from other 10 tricuspid aortic valve, 10 BAVnon-dil, and 10 BAVdil patients. The serum concentration of study targets was assessed through ELISA and the ratio of serum TGF-ß1/ENG (T/E) was evaluated. All BAVnon-dil patients underwent follow-up echocardiography to assess aortic growth rate. In BAVnon-dil patients, TGF-ß1 and MMP-2 gene expression increased significantly, whereas MMP-14 and ENG expression decreased versus controls. Expression changes were confirmed at protein level for TGF-ß1 and ENG. TGF-ß1 serum concentration significantly decreased in tricuspid aortic valve and BAVnon-dil patients versus healthy subjects. ENG serum concentration decreased in all patients, more markedly in BAVdil. A significant increase of the T/E ratio versus healthy subjects was unique of patients with BAV. In BAVnon-dil patients, a T/E ≥9 was independently associated in multivariable analysis with higher MMP-2 and lower superoxide dismutase 3 gene expression, independent of age and aortic diameter. A significant correlation was observed between baseline T/E ratio and aortic diameter growth rate in BAVnon-dil patients (r=0.66, P<0.001). CONCLUSIONS: The novel evidence of a possible value of the T/E ratio as a biomarker of BAV aortopathy was presented: further validation studies are warranted.


Asunto(s)
Estenosis de la Válvula Aórtica/sangre , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/anomalías , Endoglina/sangre , Enfermedades de las Válvulas Cardíacas/sangre , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Factor de Crecimiento Transformador beta1/sangre , Adulto , Anciano , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Enfermedad de la Válvula Aórtica Bicúspide , Biomarcadores/sangre , Ecocardiografía , Femenino , Estudios de Seguimiento , Enfermedades de las Válvulas Cardíacas/cirugía , Humanos , Masculino , Persona de Mediana Edad
19.
Platelets ; 30(4): 480-486, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-29676943

RESUMEN

The impact of thrombocytopenia on postoperative bleeding and other major adverse events after cardiac surgery is unclear. This issue was investigated in a series of patients who underwent isolated coronary artery bypass grafting (CABG) from the prospective, multicenter E-CABG registry. Preoperative thrombocytopenia was defined as preoperative platelet count <150 × 109/L and it was considered moderate-severe when preoperative platelet count was <100 × 109/L. Multilevel mixed-effects regression analysis was performed to adjust the effect of thrombocytopenia on outcomes for baseline and operative covariates as well as for interinstitutional differences in patient-blood management. Among 7189 patients included in this analysis, 599 (8.3%) had preoperative thrombocytopenia. Patient with preoperative thrombocytopenia had an increased chest drainage output at 12 h (mean, 519 vs. 456 mL, adjusted coeff. 39, 95%CI 18-60) and rates of severe-massive bleeding (Universal Definition of Perioperative Bleeding (UDPB) severity grades 3-4: 12.7% vs. 8.1%, adjusted OR 1.47, 95%CI 1.11-1.93; E-CABG bleeding severity grades 2-3: 10.4% vs. 6.1%, adjusted OR 1.78, 95%CI 1.30-2.43). Thrombocytopenia was associated with an increased risk of hospital/30-day death (3.2% vs. 1.9%, adjusted OR 2.02, 95%CI 1.20-3.42), 1-year death (5.7% vs. 3.4%, adjusted HR 1.68, 95%CI 1.16-2.44), deep sternal wound infection (3.5% vs. 2.4%, adjusted OR 1.65, 95%CI 1.02-2.66), acute kidney injury (28.1% vs. 22.2%, OR 1.45, 1.18-1.78), and prolonged stay in the intensive care unit (mean, 3.6 vs 2.8 days, adjusted coeff. 0.74, 95%CI 0.40-1.09). Similar results were observed in a subset of patients with moderate-severe thrombocytopenia (51 patients, 0.7%). In particular, these patients had a markedly higher rate of acute kidney injury (40%, adjusted OR, 1.94, 95%CI 1.05-3.57), resternotomy for bleeding (7.8%, adjusted OR 3.49, 95%CI 1.20-10.21), and severe-massive bleeding (UDPB severity grades 3-4: 23.5%, adjusted OR 3.08, 95%CI 1.52-6.22; E-CABG bleeding severity grades 2-3: 23.5%, adjusted OR 4.43, 95%CI 2.15-9.15) compared to patients with normal preoperative platelet count. Mild preoperative thrombocytopenia is associated with increased risk of severe-massive bleeding, mortality, and other major adverse events after CABG. Such risks are markedly increased in patients with moderate-severe preoperative thrombocytopenia.


Asunto(s)
Puente de Arteria Coronaria/efectos adversos , Trombocitopenia/etiología , Anciano , Femenino , Humanos , Masculino , Periodo Preoperatorio , Estudios Prospectivos , Trombocitopenia/patología
20.
Thorac Cardiovasc Surg ; 67(8): 644-651, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30114715

RESUMEN

BACKGROUND: The Freedom SOLO (FS) stentless bovine-pericardial prosthesis with a supra-annular implantation technique can be a viable option for patients with endocarditic annular destruction. We assessed early- and long-term outcomes following the use of this prosthesis in extensive aortic valve endocarditis. METHODS: From 2006 to 2016, 59 patients with extensive aortic endocarditis underwent aortic valve replacement (AVR) with FS (cumulative follow-up 263 patients-years) in three European centers; all patients presented annular tissue infection, while 54.3% of patients had annular abscess. RESULTS: Mean age was 66 ± 11 years and mean EuroSCORE I was 30.3% (standard deviation: 24.1%). In our series, 30.5% of patients had prosthetic valve endocarditis. Early mortality was 15.2% (nine patients). Estimated overall survival at 5 and 10 years was 68.9% (95% confidence interval [CI]: 62.8-75.0%) and 59.1% (95% CI: 66.8-81.2%), respectively. At 10-year survival, freedom from valve-related death was 83.7% (95% CI: 80.9-86.5%). No structural valve deterioration was reported in this series. Five patients (8.5%) had recurrent endocarditis during follow-up and two of them underwent reoperation. Survival freedom from reoperation and endocarditis at 10-year follow-up was 88.0% (CI: 80.4-95.6%) and 86.7% (CI: 80.5-92.9%), respectively. CONCLUSION: FS stentless bioprosthesis is a valuable and simple option to achieve AVR in patients with extensive aortic annulus endocarditis. Although in this group of complex patients, early mortality remains considerably high, late survival outcomes are comparable to the more technically demanding homografts and conventional stentless bioprostheses, with low rates of endocarditis recurrence.


Asunto(s)
Válvula Aórtica/cirugía , Bioprótesis , Endocarditis/terapia , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Anciano , Válvula Aórtica/fisiopatología , Endocarditis/diagnóstico , Endocarditis/mortalidad , Endocarditis/fisiopatología , Europa (Continente) , Femenino , Alemania , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/cirugía , Supervivencia sin Progresión , Diseño de Prótesis , Recuperación de la Función , Recurrencia , Reoperación , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA