Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
Más filtros

Intervalo de año de publicación
1.
J Esthet Restor Dent ; 27 Suppl 1: S33-40, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25771826

RESUMEN

PURPOSE: The aim of this study was to evaluate the fluorescence intensity of a composite in different layering techniques combined to a surface sealant submitted to staining solutions. METHODS AND MATERIALS: One surface sealant and one composite resin (shades A2-0, A2, and YE) were tested. Specimens were carried out using layering with different shades of composite, and dental blocks (dentin/enamel) were obtained of human molars. Fluorescence intensity measurement performed using a spectrofluorophotometer, before and after storage in cola, orange juice, red wine, and distilled water. Data were subjected to analysis of variance and Fisher's test (α = 0.05). RESULTS: Initially, only A2-O + A2 layering showed fluorescence intensity statistically similar to the natural tooth. Overall, groups sealed showed the highest fluorescence intensity compared with unsealed groups. The aging decreased the fluorescence intensity compared with initial values. Red wine showed the highest decrease on the fluorescence intensity. CONCLUSION: The fluorescence of composite restorations is dependent of the layering technique and is affected by the diet. CLINICAL SIGNIFICANCE: The staining solutions decreased the fluorescence intensity, even when the composite resins were sealed. Different shades of the same composite showed distinct fluorescence values, so there should be greater standardization of this property for tooth reconstruction success by the layering technique with large tissue loss.


Asunto(s)
Resinas Compuestas , Selladores de Fosas y Fisuras , Fluorescencia , Humanos , Soluciones , Espectrometría de Fluorescencia , Decoloración de Dientes
2.
Braz Dent J ; 35: 5746, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39045986

RESUMEN

This study aimed to evaluate the bond strength between relined fiberglass posts with different composite resin opacities in different thirds of the intraradicular dentin. Thirty single-rooted premolars were endodontically treated and divided into three groups (n=10): fiberglass posts relined with translucent composite resin, fiberglass posts relined with opaque composite resin, and fiberglass posts without relining. After cementation of the posts, the specimens were cut perpendicular to the long axis of the tooth in slices of approximately 1.3 mm of each third to be analyzed (cervical, middle, and apical) and then subjected to the push-out test. The bond strength (MPa) data were subjected to Shapiro-Wilk normality tests and two-way repeated measures analysis of variance, considering the experimental groups and different regions as study factors. Tukey's post-hoc test (p<.05) was applied for comparisons between the groups. In the cervical third, higher values of bond strength were found for the group relined with translucent resin, with a statistically significant difference for the other groups. In the other regions, both opaque and translucent resins showed similar results, but both showed higher values of bond strength compared to fiberglass posts without relining. The bond strength of fiberglass posts to different thirds of intraradicular dentin is influenced by composite resin relining as well as the opacity of the resin. The use of translucent composite resin is a more effective alternative for fiberglass posts relining.


Asunto(s)
Resinas Compuestas , Recubrimiento Dental Adhesivo , Dentina , Vidrio , Técnica de Perno Muñón , Humanos , Resinas Compuestas/química , Recubrimiento Dental Adhesivo/métodos , Análisis del Estrés Dental , Ensayo de Materiales , Propiedades de Superficie , Materiales Dentales/química , Diente no Vital
3.
Aust Endod J ; 50(2): 309-320, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38509781

RESUMEN

This study aimed to evaluate the interface of universal adhesive (UA) with bulk-fill resin (BF) and dentin, after endodontic irrigation. The pulp chamber of 96 molars was irrigated with chlorhexidine 2% (CHX) or sodium hypochlorite 5.25% (NaOCl) and restored according to three restorative protocols. Microtensile bond strength (µTBS) and nanoleakage tests were performed after 24 h of thermocycling. Kruskal Wallis, Mann-Whitney and Wilcoxon were performed (p < 0.05). Comparing restorative systems, a difference was found only when irrigated with CHX after 24 h. CHX provided higher µTBS than NaOCl after 24 h for two restorative protocols; after thermocycling, NaOCl provided the greatest µTBS than CHX for one group. Decreased µTBS was observed for all restorative systems when CHX was used after thermocycling. NaOCl demonstrated the highest nanoleakage. The composition of UA influenced the immediate adhesion and sealing to BF when CHX was used; ageing has a deteriorating effect on adhesion and sealing for all restorative systems.


Asunto(s)
Recubrimiento Dental Adhesivo , Humanos , Técnicas In Vitro , Recubrimiento Dental Adhesivo/métodos , Irrigantes del Conducto Radicular/química , Hipoclorito de Sodio/química , Resistencia a la Tracción , Filtración Dental , Resinas Compuestas/química , Clorhexidina/farmacología , Clorhexidina/química , Cementos de Resina/química , Ensayo de Materiales , Cementos Dentales/química
4.
Braz Dent J ; 34(6): 67-74, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38133093

RESUMEN

This study aimed to evaluate the influence of dental adhesive color on the chromatic stability and fluorescence intensity of composite resin restorations of different thicknesses. Ninety bovine enamel samples were obtained and restored with resin composite varying thicknesses of restorative material and enamel (1.0 mm enamel and 1.0 mm composite; 1.5 mm enamel and 0.5 mm composite; 0.5 mm enamel and 1.5 mm composite). The restorations were made of composite resin (Opallis E-bleach H) using different types of dental adhesives: Ambar, Ambar APS, and Single Bond Universal (n=10). The samples were subjected to color measurement tests in a spectrophotometer using CIEDE2000 and fluorescence intensity measurements before and after aging in a red wine coloring solution. Data were subjected to analysis of variance (ANOVA) and Tukey's test (α = 0.05). There were no statistically significant changes in color stability or fluorescence intensity for restorations made of different materials or thicknesses (p>0.05). Single Bond Universal showed greater color stability at 0.5 mm thickness (ΔE00 = 4.4 ± 1.6) compared to other thicknesses of the same material (p=0.003), as well as a greater difference in fluorescence intensity after aging at 1.5 mm thickness (-414.9 ± 103.8) compared to other materials (p=0.0002). Overall, it was concluded that the different adhesive systems did not influence the color stability and fluorescence of restorations of different thicknesses.


Asunto(s)
Cementos Dentales , Cementos de Resina , Animales , Bovinos , Cementos Dentales/química , Cementos de Resina/química , Resinas Compuestas/química , Color , Ensayo de Materiales
5.
Acta Odontol Scand ; 70(1): 56-60, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-21492064

RESUMEN

OBJECTIVE: The purpose of this study was to evaluate the effect of the bleaching agents on the elastic modulus of bovine demineralized dentin matrix (EMDM). MATERIALS AND METHODS: Eighty-five slices were obtained from 17 bovine teeth. The slices were divided randomly into five experimental groups (n = 17): unbleached control group (CG), 4% hydrogen peroxide (HP4), 4% hydrogen peroxide + 0.05% Ca (HP4 + Ca), 7.5% hydrogen peroxide + ACP (HP7.5) and 10% carbamide peroxide (CP10). The HP4, HP4 + Ca and CP10 groups were treated with the bleaching agents for 8 h/day (14 days), while the samples of HP7.5 group were exposed to bleaching agent for 30 min twice a day (14 days). The CG was kept in 100% humidity. After bleaching treatments, the enamel of the samples was removed and 85 dentin beams (0.5 × 1.7 × 7.0 mm) were prepared. Afterwards, the beams were immersed in 10% phosphoric acid solution (5 h) and rinsed with water (10 min). The beams were tested after 24 h, 7 and 14 days of storage in distilled water, using three-point bend method. Data were statistically analyzed using ANOVA and Fisher's test. RESULTS: All bleaching treatments reduced the EMDM. After 14 days post-bleaching, the EMDM increased for HP4 and HP4+Ca groups. CONCLUSIONS: The use of bleaching agents promoted a decrease in EMDM, which indicates that the bleaching treatment interacts with the dentin organic matrix. The EMDM measurement for the specimens of the 7.5% hydrogen peroxide group that were immersed in water at 14 days post-bleaching did not recover the EMDM values when compared to the control group.


Asunto(s)
Dentina/efectos de los fármacos , Blanqueadores Dentales/toxicidad , Blanqueamiento de Dientes/efectos adversos , Análisis de Varianza , Animales , Peróxido de Carbamida , Bovinos , Distribución de Chi-Cuadrado , Módulo de Elasticidad/efectos de los fármacos , Dureza/efectos de los fármacos , Peróxido de Hidrógeno/administración & dosificación , Peróxido de Hidrógeno/toxicidad , Ensayo de Materiales , Peróxidos/administración & dosificación , Peróxidos/toxicidad , Docilidad/efectos de los fármacos , Distribución Aleatoria , Urea/administración & dosificación , Urea/análogos & derivados , Urea/toxicidad
6.
J Dent ; 127: 104348, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36280006

RESUMEN

OBJECTIVES: This in vitro study aimed to evaluate the effect of different times and concentrations of hydrofluoric acid etching on the surface of indirect restorative materials obtained from blocks used in CAD-CAM technology. METHODS: Specimens (4 mm × 4 mm × 0.8 mm) were obtained for each indirect restorative material: zirconia-reinforced lithium monosilicate ceramic (Celtra Duo), nanoceramic resin (Lava Ultimate), and polymer-infiltrated ceramic network material (Vita Enamic). The materials were submitted to etching with 5% or 10% hydrofluoric acid for 20, 40, 60, or 90 s. A control group for each material was evaluated without any surface treatment, totaling nine experimental groups for each material (n = 10). The specimens were evaluated for surface roughness (Ra and Rz), confocal optical microscopy, the contact angle (θ), surface free energy (γs), total free interaction energy (∆G) using a goniometer, and microshear bond strength to resin cement. Specimen images were obtained using scanning electron microscopy, confocal optical microscopy, and atomic force microscopy. Data on the surface roughness, the contact angle, surface free energy, total free interaction energy, and bond strength were subjected to two-way ANOVA and Tukey´s test (α=0.05). RESULTS: In general, Celtra Duo showed better results after etching with 10% hydrofluoric acid for 40 or 60 s. Lava Ultimate showed better performance after etching with 10% hydrofluoric acid for 20 or 40 s, whereas Vita Enamic showed better results after etching with 5% hydrofluoric acid for 90 s. CONCLUSION: Each material showed different characteristics after etching with hydrofluoric acid. Knowledge of the proper protocol for each material is essential to ensure improvements in the adhesion process and durability of indirect restorations. In general, Celtra Duo presented mechanical properties superior to those of Lava Ultimate and Vita Enamic. CLINICAL SIGNIFICANCE: Specific etching protocols must be recommended for each indirect material because longer exposure to hydrofluoric acid can jeopardize the surface, thus affecting the mechanical and bond strength properties.


Asunto(s)
Recubrimiento Dental Adhesivo , Ácido Fluorhídrico , Ácido Fluorhídrico/química , Porcelana Dental/química , Ensayo de Materiales , Propiedades de Superficie , Materiales Dentales/química , Cementos de Resina/química , Cerámica/química , Diseño Asistido por Computadora
7.
J Mech Behav Biomed Mater ; 123: 104762, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34371332

RESUMEN

PURPOSE: Studies evaluating different features of cold plasma action on dentin surface characteristics are lacking. Thus, this in vitro study aimed to determine the effect of cold plasma under different protocols of exposure time, distance to plasma source, and the association of argon gas with distinct concentrations of oxygen on the wettability, surface energy, total free interaction energy, surface roughness, morphology and chemical composition of dentin. MATERIAL AND METHODS: One hundred and twenty-five bovine dentin samples were used and divided into twenty-five groups according to the exposure time to plasma (15, 30, or 60 s); distance between plasma source and dentin surface (3 or 6 mm); argon gas without plasma generation; and plasma generated by argon gas and association of argon gas with distinct concentrations of oxygen (2 % or 3 %) (n = 5). Contact angle (θ), surface energy (γs) and total free interaction energy (ΔG) were measured using a goniometer (Krüss), while surface roughness (Ra) was evaluated by a profilometer (Mitutoyo). Representative samples were submitted to scanning electron microscopy (JEOL) to ilustrate the morphology and chemical composition of dentin. Data comparing control group with all experimental groups were submitted to ANOVA followed by Tukey's test (α = .05). Data comparing oxygen gas action at different concentrations and argon gas on dentin characteristics were submitted to non-parametric Kruskal-Wallis test, followed by Dunn test for comparison between the groups and methods (α = 0.05). RESULTS: In general, argon gas without plasma generation promoted no significant difference on dentin surface characteristics compared to control group (P > .05), differently for the cold plasma that significantly reduced contact angle values and increased total free interaction energy of dentin surface (P < .05). Overall, feeding of oxygen at distinct concentrations promoted significant difference on dentin surface characteristics compared to control group (P < .05). Exposure time and distance protocols interfered with contact angle, surface energy and total free interaction energy analyses for each gas. There was no significant difference on surface roughness (P > .05), morphology and chemical composition of dentin submitted to argon gas, cold plasma, and distinct concentrations of oxygen. CONCLUSION: In conclusion, plasma generated by argon gas and its feeding with 2 % and 3 % oxygen gas improved the dentin surface characteristics about wettability, surface energy and total free interaction energy. Such treatments preserved the surface roughness, morphology and chemical composition of dentin. The protocols of groups Ar-6mm-15sec, ArO2-3mm-30sec and ArO3-3mm-15sec are recommended for improvement of dentin surface characteristics.


Asunto(s)
Gases em Plasma , Animales , Argón , Bovinos , Dentina , Microscopía Electrónica de Rastreo , Propiedades de Superficie , Humectabilidad
8.
J Appl Oral Sci ; 28: e20200493, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32997089

RESUMEN

OBJECTIVE: This study aimed to evaluate the effects of different toothpastes on the surface wear of enamel, dentin, composite resin (CR), and resin-modified glass ionomer cement (RMGIC), and to perform a topographic analysis of the surfaces, based on representative images generated by atomic force microscopy (AFM) after erosion-abrasion cycles. METHODOLOGY: One hundred and forty bovine incisors were collected and divided into two groups: 72 enamel and 72 dentin blocks (4×4 mm). Half of the specimens were restored with CR (Filtek Z350 XT) and the other half with RMGIC (Fuji II LC). Then, samples were submitted to a demineralization cycle (5 days, 4×2 min/day, 1% citric acid, pH 3.2) and exposed to three different toothpastes (2×15 s/day): without fluoride (WF, n=12), sodium fluoride-based (NaF, n=12), and stannous fluoride-based (SnF2, n=12). Surface wear, as well as restoration interfaces wear, were investigated by profilometry of the dental substrates and restorative materials. All representative surfaces underwent AFM analysis. Data were analyzed by two-way analysis of variance and Tukey's tests (α=0.05). RESULTS: NaF-based toothpaste caused the greater dentin surface wear (p<0.05). Toothpastes affected only enamel-restoration interfaces. AFM analysis showed precipitate formation in dentinal tubules caused by the use of fluoride toothpastes. CONCLUSIONS: NaF-based toothpastes had no protective effect on enamel adjacent to CR and RMGIC against erosion-abrasion challenges, nor on dentin adjacent to RMGIC material. SnF2-based toothpastes caused more damage to interfaces between enamel and RMGIC.


Asunto(s)
Resinas Compuestas , Cementos de Ionómero Vítreo , Erosión de los Dientes , Pastas de Dientes , Animales , Bovinos , Esmalte Dental , Dentina , Erosión de los Dientes/inducido químicamente , Erosión de los Dientes/prevención & control
9.
Braz Dent J ; 30(2): 106-116, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30970052

RESUMEN

The aim of this study was to evaluate the push-out bond strength and interface permeability of glass-fiber posts in different regions of post space (cervical, middle, and apical) submitted to different irrigation solutions. Ninety single-rooted human teeth were submitted to endodontic treatment and divided into five groups, according to irrigation solutions: distilled water, 5.25% NaOCl, 25% polyacrylic acid, 2% chlorhexidine, and 23 ppm Ag NP dispersion. Each group was divided in 3 subgroups (n=6) according to cementation: SBU: Adper Scotchbond Universal + RelyX ARC; U200: RelyX U200; MCE: MaxCem Elite. Bond strength and sealing ability were measured in different areas of post space. The data was subjected to ANOVA and Fisher's test (a=0,05). The silver nanoparticle solution showed highest bond strength values and lowest interface permeability in all thirds analyzed for SBU group. In the U200 group, the highest bond strength values were found for sodium hypochlorite solution, with significant difference between this solution and polyacrylic acid. A decrease in bond strength values in cervical to apical direction was found for MCE group and the same behavior were found for others groups. Regarding interface permeability, use of silver nanoparticle solution resulted in lower values in cervical and apical thirds. There was a decrease in bond strength in cervical to apical direction. Different irrigation solutions and intraradicular depth influenced the bond strength and interface permeability of adhesive material to dentin substrate. Silver nanoparticle solution can effectively be used as an irrigation agent in post space prior to fiber post cementation process.


Asunto(s)
Recubrimiento Dental Adhesivo , Nanopartículas del Metal , Técnica de Perno Muñón , Dentina , Vidrio , Humanos , Ensayo de Materiales , Cementos de Resina , Plata
10.
Braz Oral Res ; 33: e024, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30970089

RESUMEN

The aim of this study is to evaluate the effect of chitosan or nanodiamond incorporation on the color stability and surface roughness of a bisacrylic resin subjected to artificial aging. Four bisacrylic resins were evaluated, namely, control, chitosan-modified material, nanodiamond-modified material, and chitosan-nanodiamond-modified material. Twenty-four specimens were prepared for each material. The surface roughness was determined using a profilometer with a cut-off of 0.25 mm. The baseline color was measured according to the CIE L*a*b* system using a reflectance spectrophotometer. After these tests, the specimens were individually immersed in cola soft drink, red wine, or distilled water (n = 8) for 28 days. After the aging, the surface roughness and final color were re-evaluated. The color stability was determined using the difference between the coordinates obtained before and after the aging process. The data on roughness and color change were evaluated using ANOVA and the Tukey test (α = 0.05). The results show that the incorporation of nanodiamonds and chitosan into a bisacrylic resin provided a better color stability to the materials (p = 0.007). The storage in red wine resulted in a higher variation in the surface roughness values, especially when only the nanodiamond was incorporated to the material (p < 0.05). The incorporation of both chitosan and nanodiamonds are promising in providing an improvement in the properties of the bisacrylic resin when they are simultaneously incorporated in the product.


Asunto(s)
Resinas Acrílicas/química , Quitosano/química , Color , Resinas Compuestas/química , Nanodiamantes/química , Análisis de Varianza , Bebidas Gaseosas , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Valores de Referencia , Reproducibilidad de los Resultados , Espectrofotometría , Estadísticas no Paramétricas , Propiedades de Superficie , Factores de Tiempo , Agua/química , Vino
11.
J Mech Behav Biomed Mater ; 97: 7-12, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31082715

RESUMEN

The aim of this study was to evaluate the mechanical resistance of dentin and restorative materials submitted to erosive/abrasive challenges with different dentifrices. The dentin was restored using a resin-modified glass-ionomer (RMGIC) or a composite resin (RC). One hemiface of the sample was protected, and the other was subdivided according to the applied dentifrice (n = 10): without fluoride (SF), sodium fluoride (NaF) and stannous fluoride (SnF). The specimens were submitted to erosive/abrasive cycles, the varnish was removed, and the Martens hardness (HMV) and elastic modulus (Eit) were evaluated. The data were analyzed by repeated two-way ANOVA measurements and Tukey tests (alpha = 0.05). When analyzing the HMV on the test side, there was no influence of the dentifrices in the dentin; however, the orders of NaF < SnF = SF in RC and SnF > NaF = SF in RMGIC were observed. Comparing the treated surfaces, there were no differences in the dentin, and only the SF since CR presented an HMV superior to that of RMGIC. Comparing control and test sides, both dentins obtained a decreased HMV after the erosive/abrasive challenge; for the restorative materials, superior values were found only for SnF in the RMGIC. The Eit values were influenced more by the dentifrices on the test side for the dentin adjacent to the RMGIC, with the lowest values shown for the SF, and for both materials, the highest values were shown for the SnF group. No differences were found when comparing each dentin treated with the same dentifrice; however, the RMGIC presented a superior Eit than the CR when brushed with both dentifrices with a fluoride. Comparing the control and test sides, the same results were obtained for the HMV. The dentifrices showed little influence on the dentin substrate, whereas the dentifrice with SnF enhanced the mechanical properties of the restorative materials, which was more evident in the RMGIC.


Asunto(s)
Resinas Acrílicas/química , Dentífricos/farmacología , Dentina/química , Dentina/efectos de los fármacos , Dióxido de Silicio/química , Fluoruro de Sodio/farmacología , Fluoruros de Estaño/farmacología , Animales , Bovinos , Resinas Compuestas/química , Módulo de Elasticidad , Dureza , Técnicas In Vitro , Ensayo de Materiales , Presión , Estrés Mecánico , Propiedades de Superficie
12.
Braz. dent. j ; Braz. dent. j;35: e24, 2024. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO - odontología (Brasil) | ID: biblio-1564090

RESUMEN

Abstract This study aimed to evaluate the bond strength between relined fiberglass posts with different composite resin opacities in different thirds of the intraradicular dentin. Thirty single-rooted premolars were endodontically treated and divided into three groups (n=10): fiberglass posts relined with translucent composite resin, fiberglass posts relined with opaque composite resin, and fiberglass posts without relining. After cementation of the posts, the specimens were cut perpendicular to the long axis of the tooth in slices of approximately 1.3 mm of each third to be analyzed (cervical, middle, and apical) and then subjected to the push-out test. The bond strength (MPa) data were subjected to Shapiro-Wilk normality tests and two-way repeated measures analysis of variance, considering the experimental groups and different regions as study factors. Tukey's post-hoc test (p<.05) was applied for comparisons between the groups. In the cervical third, higher values of bond strength were found for the group relined with translucent resin, with a statistically significant difference for the other groups. In the other regions, both opaque and translucent resins showed similar results, but both showed higher values of bond strength compared to fiberglass posts without relining. The bond strength of fiberglass posts to different thirds of intraradicular dentin is influenced by composite resin relining as well as the opacity of the resin. The use of translucent composite resin is a more effective alternative for fiberglass posts relining.


Resumo Este estudo teve como objetivo avaliar a resistência de união entre pinos de fibra de vidro anatomizados com resinas compostas de diferentes opacidades em diferentes terços da dentina intrarradicular. Trinta pré-molares uniradiculares foram tratados endodonticamente e divididos em três grupos (n=10): pinos de fibra de vidro anatomizados com resina composta translúcida, pinos de fibra de vidro anatomizados com resina composta opaca e pinos de fibra de vidro sem anatomização. Após a cimentação dos pinos, os corpos de prova foram cortados perpendicularmente ao longo eixo do dente em fatias de aproximadamente 1,3 mm de cada terço a ser analisado (cervical, médio e apical) e posteriormente submetidos ao teste de push-out. Os dados de resistência de união (MPa) foram submetidos a testes de normalidade de Shapiro-Wilk e ANOVA dois fatores para análises repetidas, considerando os grupos experimentais e diferentes regiões como fatores de estudo. O teste post-hoc de Tukey (p=0,05) foi aplicado para comparações entre os grupos. No terço cervical foram encontrados maiores valores de resistência de união no grupo com anatomização com resina translúcida, com diferença estatisticamente significativa para os demais grupos. Nas demais regiões, tanto as resinas opacas quanto as translúcidas apresentaram resultados semelhantes, mas ambas apresentaram valores de resistência de união superiores aos pinos de fibra de vidro sem anatomização. A resistência de união dos pinos de fibra de vidro aos diferentes terços da dentina intrarradicular é influenciada pela anatomização da resina composta, bem como pela opacidade da resina. A utilização de resina composta translúcida é uma alternativa mais eficaz para a anatomização de pinos de fibra de vidro.

13.
Eur J Dent ; 12(3): 446-449, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30147415

RESUMEN

This case report presents a minimally invasive diastema treatment using cordless gingival displacement system allowing a very conservative intervention. A 32-year-old female patient who presented with diastema in her upper front teeth opted for a treatment using laminate veneers to ensure achieving adequate tooth proportion and gingival levels. Having a displacement material that exerts excessive pressure during the displacement process can lead to disruption of the junctional epithelium and damage to periodontal tissues. This case report focuses on the effectiveness of the use of a minimally invasive method of gingival management. Two-year follow-up no infiltration, sensitivities, or fractures were detected on teeth, and indirect restorations, the purposed treatment allowed a quick, effective, and durable resolution for diastema.

14.
Eur J Dent ; 12(4): 559-565, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30369803

RESUMEN

OBJECTIVE: This study aims to evaluate the effect of acidic solutions (AS) on surface roughness (Ra) and microhardness of restorative materials (RM). MATERIALS AND METHODS: Eight volunteers wore intraoral palatal devices (IPD) containing samples of RM: Ketac Nano (KN); Ketac Nano + Biscover LV (KN-B); Esthet-X (EX); Esthet-X + Biscover LV (EX-B); Supreme XT (SXT); Supreme XT + Biscover LV (SXT-B); and bovine enamel. The samples were submitted to three phases: (1) immersion in 0.01M hydrochloric acid (HCl) - 10 min, three times/day (14 days); (2) immersion in soft drink (Sprite®) - 10 min, three times/day (14 days); and (3) keeping in saliva (14 days). Changes in Ra/microhardness were measured before/after the three phases. STATISTICAL ANALYSIS: ANOVA (α = 0.05) and Fisher's test. RESULTS: Materials sealed with Biscover LV (B) presented lowest values in all periods. KN glass ionomer cement showed highest Ra values after exposure in AS. Application of B did not reduce the Ra for the composites studied, except for EX after immersion in HCl. AS promoted changes in Ra/microhardness of RM, except for sealed materials. CONCLUSIONS: The acids used were able to change the Ra and microhardness of RM, except of the sealed materials. The resin-modified GIC showed the most significant changes after immersion in AS; and the composites sealed with B, even after immersion in acidic solutions (AS), showed the lowest Ra values and the least degradation in microhardness, especially when subjected to low pH solutions.

15.
J Appl Oral Sci ; 26: e20170284, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29742258

RESUMEN

Objective The objective of this study was to evaluate dental sensitivity using visual analogue scale, a Computerized Visual Analogue Scale (CoVAS) and a neurosensory analyzer (TSA II) during at-home bleaching with 10% carbamide peroxide, with and without potassium oxalate. Materials and Methods Power Bleaching 10% containing potassium oxalate was used on one maxillary hemi-arch of the 25 volunteers, and Opalescence 10% was used on the opposite hemi-arch. Bleaching agents were used daily for 3 weeks. Analysis was performed before treatment, 24 hours later, 7, 14, and 21 days after the start of the treatment, and 7 days after its conclusion. The spontaneous tooth sensitivity was evaluated using the visual analogue scale and the sensitivity caused by a continuous 0°C stimulus was analyzed using CoVAS. The cold sensation threshold was also analyzed using the TSA II. The temperatures obtained were statistically analyzed using ANOVA and Tukey's test (α=5%). Results The data obtained with the other methods were also analyzed. 24 hours, 7 and 14 days before the beginning of the treatment, over 20% of the teeth presented spontaneous sensitivity, the normal condition was restored after the end of the treatment. Regarding the cold sensation temperatures, both products sensitized the teeth (p<0.05) and no differences were detected between the products in each period (p>0.05). In addition, when they were compared using CoVAS, Power Bleaching caused the highest levels of sensitivity in all study periods, with the exception of the 14th day of treatment. Conclusion We concluded that the bleaching treatment sensitized the teeth and the product with potassium oxalate was not able to modulate tooth sensitivity.


Asunto(s)
Sensibilidad de la Dentina/inducido químicamente , Sensibilidad de la Dentina/diagnóstico , Dimensión del Dolor/métodos , Peróxidos/efectos adversos , Blanqueadores Dentales/efectos adversos , Blanqueamiento de Dientes/efectos adversos , Urea/análogos & derivados , Adolescente , Adulto , Análisis de Varianza , Peróxido de Carbamida , Femenino , Humanos , Masculino , Ácido Orótico/uso terapéutico , Umbral del Dolor , Peróxidos/química , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento , Urea/efectos adversos , Urea/química , Escala Visual Analógica , Adulto Joven
16.
J Appl Oral Sci ; 26: e20170043, 2018 Jan 18.
Artículo en Inglés | MEDLINE | ID: mdl-29364338

RESUMEN

This study verified the occurrence of dental sensitivity in patients submitted to a 35% hydrogen peroxide based product (Whiteness HP Maxx 35% - FGM), skin cold sensation threshold (SCST) and its influence on dental sensitivity. Sixty volunteers were divided into 4 groups (n = 15), according to SCST (low: GI and GIII, and high: GII and IV) and bleaching treatment (hydrogen peroxide: GI and GII, and placebo: GIII and GIV). SCST was determined in the inner forearm for 6 different times using a neurosensory analyzer, the TSA II (Medoc Advanced Medical Systems, Ramat Yishai, Northern District, Israel). Dental sensitivity measurements were performed 10 different times using a thermal stimulus and an intraoral device attached to TSA II, positioned in the buccal surface of the upper right central incisor. Spontaneous dental sensitivity was also determined using the Visual Analogue Scale (VAS). Data were submitted to Student's t-test and Pearson's Correlation Test (α=0.05). SCST remained the same during bleaching treatment. Distinct responses of dental sensitivity were found in patients with low and high SCST during the first and third bleaching session (p≤0.05). The teeth submitted to the bleaching treatment became more sensitive to cold than those treated with placebo. Moreover, data obtained with TSA and VAS presented moderate correlation. Bleaching treatment increased dental sensitivity and skin cold sensation threshold might represent a determining factor in this occurrence, since low and high SCST patients had different responses to the thermal stimulus in the teeth.


Asunto(s)
Sensibilidad de la Dentina/inducido químicamente , Peróxido de Hidrógeno/efectos adversos , Temperatura Cutánea/efectos de los fármacos , Blanqueadores Dentales/efectos adversos , Blanqueamiento de Dientes/efectos adversos , Adolescente , Adulto , Frío , Humanos , Masculino , Dimensión del Dolor , Efecto Placebo , Valores de Referencia , Umbral Sensorial , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
17.
Braz. dent. j ; Braz. dent. j;34(6): 67-74, 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO - odontología (Brasil) | ID: biblio-1528033

RESUMEN

Abstract This study aimed to evaluate the influence of dental adhesive color on the chromatic stability and fluorescence intensity of composite resin restorations of different thicknesses. Ninety bovine enamel samples were obtained and restored with resin composite varying thicknesses of restorative material and enamel (1.0 mm enamel and 1.0 mm composite; 1.5 mm enamel and 0.5 mm composite; 0.5 mm enamel and 1.5 mm composite). The restorations were made of composite resin (Opallis E-bleach H) using different types of dental adhesives: Ambar, Ambar APS, and Single Bond Universal (n=10). The samples were subjected to color measurement tests in a spectrophotometer using CIEDE2000 and fluorescence intensity measurements before and after aging in a red wine coloring solution. Data were subjected to analysis of variance (ANOVA) and Tukey's test (α = 0.05). There were no statistically significant changes in color stability or fluorescence intensity for restorations made of different materials or thicknesses (p>0.05). Single Bond Universal showed greater color stability at 0.5 mm thickness (ΔE00 = 4.4 ± 1.6) compared to other thicknesses of the same material (p=0.003), as well as a greater difference in fluorescence intensity after aging at 1.5 mm thickness (-414.9 ± 103.8) compared to other materials (p=0.0002). Overall, it was concluded that the different adhesive systems did not influence the color stability and fluorescence of restorations of different thicknesses.


Resumo O objetivo deste estudo foi avaliar a influência da cor do adesivo dental na estabilidade cromática e intensidade de fluorescência das restaurações de resina composta de diferentes espessuras. Foram obtidos noventa amostras de esmalte bovino que foram restaurados com resina composta, variando a espessura do material restaurador e do esmalte (1,0 mm de esmalte e 1,0 mm de compósito; 1,5 mm de esmalte e 0,5 mm de compósito; 0,5 mm de esmalte e 1,5 mm de compósito). As restaurações foram feitas de resina composta (Opallis E-bleach H) utilizando diferentes tipos de adesivos odontológicos: Ambar, Ambar APS, e Single Bond Universal (n=10). As amostras foram submetidas a testes de medição de cor em um espectrofotômetro usando CIEDE2000 e medições de intensidade de fluorescência antes e depois do envelhecimento em uma solução de coloração de vinho tinto. Os dados foram submetidos à análise de variância (ANOVA) e ao teste de Tukey (α = 0,05). Não houve mudanças estatisticamente significativas na estabilidade da cor ou intensidade de fluorescência para restaurações feitas de diferentes materiais ou espessuras (p>0,05). O Single Bond Universal mostrou maior estabilidade de cor a 0,5 mm de espessura (ΔE00 = 4,4 ± 1,6) em comparação com outras espessuras do mesmo material (p=0,03), bem como uma maior diferença na intensidade de fluorescência após o envelhecimento a 1,5 mm de espessura (-414,9 ± 103,8) em comparação com outros materiais (p=0,0002). Em geral, concluiu-se que os diferentes sistemas adesivos não influenciaram a estabilidade de cor e a intensidade de fluorescência das restaurações de diferentes espessuras.

18.
Braz Dent J ; 27(2): 153-9, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27058377

RESUMEN

The aim of the study was to evaluate the effect of erosive pH cycling with solutions that simulate dental erosion on Martens hardness (HMV) and elastic modulus (Eit) of dentin restored with fluoride-releasing adhesive systems. Twenty-seven bovine dentin slabs were restored with three adhesive systems: Adper Single Bond 2 total-etch adhesive system, One Up Bond F and Clearfil SE Protect fluoride-containing self-etching adhesive systems. The restorations were made with Filtek Z250. The HMV and Eit values at distances of 10, 30, 50 and 70 µm from the interface were evaluated using a dynamic ultra microhardness tester before and after immersion in deionized water, citric acid and hydrochloric acid (n=9). Data were submitted to repeated-measures ANOVA and Fisher's PLSD tests (=0.05). After erosive cycling, HMV values of dentin decreased in all groups. For dentin restored with Adper Single Bond 2, the lowest values were found closer to the hybrid layer, while for One Up Bond F and Clearfil SE Protect, the values remained unaltered at all distances. For dentin restored with fluoride-releasing adhesive systems, a decrease in Eit was found, but after 30 µm this difference was not significant. The acid substances were able to alter HMV and Eit of the underlying dentin. For fluoride-releasing adhesives, the greater the distance from bonded interface, the lower the Eit values. The fluoride in One Up Bond F and Clearfil SE Protect was able to protect the underlying dentin closer to the materials. In this way, the fluoride from adhesive systems could have some positive effect in the early stages of erosive lesions.


Asunto(s)
Adhesivos , Dentina/química , Fluoruros/administración & dosificación , Animales , Bovinos , Elasticidad , Pruebas de Dureza , Concentración de Iones de Hidrógeno
19.
Braz Dent J ; 27(4): 399-403, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27652700

RESUMEN

Abastract This study aimed to evaluate the transenamel and transdentinal penetration of hydrogen peroxide (H202) applied to bovine teeth pigmented with black tea at different intensities. The following groups were formed DW: immersion in distilled water; BT100: immersion in an infusion of 1.6 g of black tea per 100 mL distilled water; BT10: immersion in an infusion of 1.6 g black tea per 10 mL distilled water. All groups were immersed for 6 days. To quantify the penetration of H202, the specimens were placed in artificial pulp chambers (APCs) and subjected to bleaching treatment with 38% H2O2 once per week for 3 weeks. After bleaching treatment, the acetate buffer solution of APCs with peroxidase enzyme was evaluated in a reflection spectrophotometer. The transenamel and transdentinal penetration of H2O2 and the L* values obtained at T1, T2 and T3 were subjected to Kruskal-Wallis and Friedman statistical tests. At T1, the H2O2 diffusion in DW was higher than that in BT100 and BT10. At the other evaluation times, the penetration values in BT100 and BT10 increased and remained similar. The L* values increased significantly in all groups at T1. At T2, the L* values were higher in DW, while the values in BT100 and BT10 were similar to each other. At the end of the experiment, BT10 showed the lowest L* values. The pigmentation level did not affect the penetration of H2O2 through the enamel and dentin and the bleaching agent effectively changed the color of the teeth.


Asunto(s)
Dentina/metabolismo , Peróxido de Hidrógeno/farmacocinética , Pigmentación , Diente , Humanos
20.
Braz Dent J ; 26(2): 135-40, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25831103

RESUMEN

The aim of this study was to evaluate the demineralization and hydrogen peroxide (HP) penetration in teeth with incipient lesions submitted to bleaching treatment. For analysis of HP penetration, sound and demineralized enamel/dentin discs were placed in artificial pulp chambers containing acetate buffer solution. After bleaching treatment, this solution was subjected for analysis of optical density by spectrophotometry and the disc surfaces were analyzed with scanning electron microscopy (SEM) and polarized light microscopy (PLM). The remaining discs were subjected for cross-sectional hardness analysis at different depths. Data were analyzed by repeated measures ANOVA and PLSD Fisher test (a=0.05). It was observed that previously demineralized teeth showed greater HP penetration (p<0.05). The bleaching treatment caused changes to a depth of 20 µm in sound enamel and up to 90 µm in demineralized enamel. SEM and PLM images revealed that the bleaching treatment caused superficial changes that were considerably more accentuated in previously demineralized teeth. It may be concluded that the enamel mineralization level influences HP penetration and the bleaching agent contributed to increase the demineralization depth.


Asunto(s)
Esmalte Dental/efectos de los fármacos , Permeabilidad de la Dentina/efectos de los fármacos , Peróxido de Hidrógeno/química , Blanqueadores Dentales/química , Blanqueamiento de Dientes/métodos , Desmineralización Dental , Animales , Bovinos , Cavidad Pulpar , Dureza , Técnicas In Vitro , Microscopía Electrónica de Rastreo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA