Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Indoor Air ; 32(2): e12988, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-35225390

RESUMEN

Oxygen therapy is an essential treatment for patients with coronavirus disease 2019, although there is a risk of aerosolization of additional viral droplets occurring during this treatment that poses a danger to healthcare professionals. High-flow oxygen through nasal cannula (HFNC) is a vital treatment bridging low-flow oxygen therapy with tracheal intubation. Although many barrier devices (including devices without negative pressure in the barrier) have been reported in the literature, few barrier devices are suitable for HFNC and aerosol infection control procedures during HFNC have not yet been established. Hence, we built a single cough simulator model to examine the effectiveness of three protective measures (a semi-closed barrier device, a personalized exhaust, and surgical masks) administered in isolation as well as in combination using particle counter measurements and laser sheet visualization. We found that the addition of a personalized exhaust to a semi-closed barrier device reduced aerosol leakage during HFNC without negative pressure. This novel combination may thus reduce aerosol exposure during oxygen therapy, enhance the protection of healthcare workers, and likely reduce nosocomial infection risk.


Asunto(s)
Microbiología del Aire , Contaminación del Aire Interior , COVID-19 , Aerosoles y Gotitas Respiratorias , Tos , Humanos , SARS-CoV-2
2.
J Infect Chemother ; 28(1): 116-119, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34580011

RESUMEN

As the first authorized COVID-19 vaccine in Japan, the BNT162b2 mRNA COVID-19 vaccine is utilized for mass vaccination. Although efficacy has been proved, real-world evidence on reactogenicity in Japanese personnel is needed to prepare the public. Healthcare workers in a large academic hospital in Japan received two doses of the Pfizer-BioNTech vaccine from March 17 to May 19, 2021. Online questionnaires were distributed to registered recipients following each dose, from day 0 through day 8. Primary outcomes are the frequency of reactogenicity including local and systemic reactions. Length of absence from work was also analyzed. Most recipients self-reported reactogenicity after the first dose (97.3%; n = 3254; mean age [36.4]) and after the second dose (97.2%; n = 3165; mean age [36.5]). Systemic reactions following the second dose were substantially higher than the first dose, especially for fever (OR, 27.38; 95% CI, [22.00-34.06]; p < 0.001), chills (OR, 16.49; 95% CI, [13.53-20.11]; p < 0.001), joint pain (OR, 8.49; 95% CI, [7.21-9.99]; p < 0.001), fatigue (OR, 7.18; 95% CI, [6.43-8.02]; p < 0.001) and headache (OR, 5.43; 95% CI, [4.80-6.14]; p < 0.001). Reactogenicity was more commonly seen in young, female groups. 19.3% of participants took days off from work after the second dose (2.2% after the first dose), with 4.7% absent for more than two days. Although most participants reported reactogenicity, severe cases were limited. This study provides real-world evidence for the general population and organizations to prepare for BNT162b2 mRNA COVID-19 vaccination in Japan and other countries in the region.


Asunto(s)
Vacunas contra la COVID-19 , COVID-19 , Vacuna BNT162 , Femenino , Personal de Salud , Humanos , Japón , ARN Mensajero/genética , SARS-CoV-2
3.
Artículo en Inglés | MEDLINE | ID: mdl-33318009

RESUMEN

Vancomycin is a synthetic antibiotic effective against Gram-positive pathogens. Although the clinical applicability of vancomycin for infants has been increasing, the pharmacokinetic data for vancomycin in extremely low-birth-weight infants are limited. The aim of this study was to construct a population pharmacokinetics model for vancomycin in extremely-low-birth-weight infants and establish an optimal dosage regimen. We enrolled children aged less than 1 year with a birth weight of less than 1,000 g and body weight at vancomycin prescription of less than 1,500 g. Pharmacokinetic data from 19 patients were analyzed, and a population pharmacokinetics model was developed using nonlinear mixed-effects modeling software. Goodness-of-fit plots, a nonparametric bootstrap analysis, and a prediction-corrected visual predictive check were employed to evaluate the final model. The dosage regimen was optimized based on the final model. The pharmacokinetic data fit a one-compartment model with first-order elimination, and body weight and estimated serum creatinine level were used as significant covariates. In a simulation using the final model, the optimal dosage regimen, especially when the serum creatinine level (>0.6 mg/dl) was high, was 5.0 to 7.5 mg/kg of body weight twice a day every 12 h; this was required to reduce the dosage compared with that in previous studies. The recommended doses based on the current target time course concentration curves may not be appropriate for extremely-low-birth-weight infants.


Asunto(s)
Recien Nacido con Peso al Nacer Extremadamente Bajo , Modelos Biológicos , Antibacterianos/uso terapéutico , Niño , Humanos , Lactante , Recién Nacido , Japón , Vancomicina
4.
Artículo en Inglés | MEDLINE | ID: mdl-28827421

RESUMEN

We previously reported a novel phenotype of vancomycin-intermediate Staphylococcus aureus (VISA), i.e., "slow VISA," whose colonies appear only after 72 h of incubation. Slow-VISA strains can be difficult to detect because prolonged incubation is required and the phenotype is unstable. To develop a method for detection of slow-VISA isolates, we studied 23 slow-VISA isolates derived from the heterogeneous VISA (hVISA) clinical strain Mu3. We identified single nucleotide polymorphisms (SNPs) in genes involved in various pathways which have been implicated in the stringent response, such as purine/pyrimidine synthesis, cell metabolism, and cell wall peptidoglycan synthesis. We found that mupirocin, which also induces the stringent response, caused stable expression of vancomycin resistance. On the basis of these results, we developed a method for detection of slow-VISA strains by use of 0.032 µg/ml mupirocin (Yuki Katayama, 7 March 2017, patent application PCT/JP2017/008975). Using this method, we detected 53 (15.6%) slow-VISA isolates among clinical methicillin-resistant S. aureus (MRSA) isolates. In contrast, the VISA phenotype was detected in fewer than 1% of isolates. Deep-sequencing analysis showed that slow-VISA clones are present in small numbers among hVISA isolates and proliferate in the presence of vancomycin. This slow-VISA subpopulation may account in part for the recurrence and persistence of MRSA infection.


Asunto(s)
Antibacterianos/farmacología , Staphylococcus aureus Resistente a Meticilina/efectos de los fármacos , Staphylococcus aureus Resistente a Meticilina/genética , Mupirocina/farmacología , Resistencia a la Vancomicina/genética , Vancomicina/farmacología , ARN Polimerasas Dirigidas por ADN/genética , Secuenciación de Nucleótidos de Alto Rendimiento , Humanos , Staphylococcus aureus Resistente a Meticilina/crecimiento & desarrollo , Pruebas de Sensibilidad Microbiana , Mutación/genética , Polimorfismo de Nucleótido Simple/genética
5.
J Anesth ; 28(3): 341-6, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24212332

RESUMEN

PURPOSE: Percutaneous transtracheal ventilation (PTV) can be life-saving in a cannot ventilate, cannot intubate situation. The aim of this study was to investigate the efficacy of PTV by measuring tidal volumes (VTs) and airway pressure (Paw) in high-flow oxygen ventilation and manual ventilation using a model lung. METHODS: We examined 14G, 16G, 18G, and 20G intravenous catheters and minitracheotomy catheters. In high-flow oxygen ventilation, the flow was set to 10 L/min, while the inspiratory:expiratory phases (I:E) were 1 s:4 s in the complete upper airway obstruction model and 1 s:1 s in the incomplete obstruction model. In manual ventilation, I:E were 2 s:4 s in the complete obstruction model and 2 s:3 s in the incomplete obstruction model. We ventilated through each catheter for 2 min and measured VT and Paw. RESULTS: In high-flow ventilation, the average VTs were approximately 150 ml and <100 ml with 14G catheters in complete and incomplete upper airway obstruction, respectively. The VTs obtained were reduced when the bore size was decreased. In manual ventilation, the average VTs were over 300 ml and approximately 260 ml with 14G catheters in complete and incomplete upper airway obstruction, respectively. In high-flow ventilation, the airway pressure tended to be higher. The minitracheotomy catheters produced over 800 ml of VT and created almost no positive end-expiratory pressure. CONCLUSIONS: High-flow ventilation tends to result in higher airway pressure despite a smaller VT, which is probably due to a PEEP effect caused by high flow.


Asunto(s)
Obstrucción de las Vías Aéreas/fisiopatología , Obstrucción de las Vías Aéreas/terapia , Pulmón/fisiología , Oxígeno/metabolismo , Respiración Artificial , Diseño de Equipo , Femenino , Humanos , Masculino , Modelos Biológicos , Respiración con Presión Positiva/instrumentación , Respiración Artificial/instrumentación , Volumen de Ventilación Pulmonar , Ventiladores Mecánicos
6.
J Anesth ; 27(1): 124-7, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23011119

RESUMEN

A woman with complex regional pain syndrome (CRPS) in the right lower extremity who wished to discontinue medications to get pregnant underwent implantation of a spinal cord stimulation system (SCS). An electrode lead was placed at Th(10-11) in the epidural space, accessed via the L(2-3) interspace with a paramedian approach, and a pulse generator was implanted in the left buttock. She kept the SCS on 24 h a day. After she had experienced several chemical abortions, finally she got pregnant via artificial insemination. She had an uneventful delivery of a healthy baby by cesarean resection under spinal anesthesia. In a patient with CRPS who has an implanted SCS system and wishes to get pregnant, the electrode lead into the low thoracic epidural space should be accessed via the high lumbar intervertebral space in consideration of a future requirement for spinal or epidural anesthesia for cesarean section. The generator should be placed in the buttock to prevent impairment of the SCS system being caused by the enlarged abdomen during pregnancy. Although we were apprehensive of adverse effects owing to the electromagnetic field force and change of blood flow in the pelvic viscera, our patient had a successful delivery. SCS is a favorable option for patients with CRPS who wish to get pregnant.


Asunto(s)
Síndromes de Dolor Regional Complejo/terapia , Terapia por Estimulación Eléctrica/métodos , Médula Espinal , Adulto , Anestesia Obstétrica , Anestesia Raquidea , Artroscopía , Cesárea , Síndromes de Dolor Regional Complejo/complicaciones , Síndromes de Dolor Regional Complejo/cirugía , Parto Obstétrico , Electrodos Implantados , Espacio Epidural , Femenino , Humanos , Embarazo , Resultado del Embarazo , Radiografía , Médula Espinal/diagnóstico por imagen
7.
Antibiotics (Basel) ; 12(11)2023 Oct 29.
Artículo en Inglés | MEDLINE | ID: mdl-37998779

RESUMEN

PURPOSE: Enterococcal bacteremia is associated with high mortality and long-term hospitalization. Here, we aimed to investigate the clinical outcomes and evaluate the risk factors for mortality in adult patients treated with vancomycin (VCM) for vancomycin-susceptible Enterococcus faecium (E. faecium) bacteremia. METHODS: This is a retrospective, record-based study. The data were collected from inpatients at a single university hospital between January 2009 and December 2020. The area under the curve (AUC) of VCM was calculated using the Bayesian approach. The primary outcome was a 30-day in-hospital mortality. RESULTS: A univariate analysis showed significant differences in the concomitant use of vasopressors, history of the use of no clinically relevant activity antimicrobial agents against E. faecium, VCM plasma trough concentration, and renal dysfunction during VCM administration between the 30-day in-hospital mortality and survival groups. However, the groups' AUC/minimum inhibitory concentration (MIC) were not significantly different. A multivariate analysis suggested that concomitant vasopressors may be an independent risk factor for 30-day in-hospital mortality (odds ratio, 7.81; 95% confidence interval, 1.16-52.9; p = 0.035). The VCM plasma trough concentrations and the AUC/MIC in the mortality group were higher than those in the surviving group. No association between the AUC/MIC and the treatment effect in E. faecium bacteremia was assumed, because the known, target AUC/MIC were sufficiently achieved in the mortality group. CONCLUSIONS: There may be no association between the AUC/MIC and the treatment effect in E. faecium bacteremia. When an immunocompromised host develops E. faecium bacteremia with septic shock, especially when a vasopressor is used in a patient with unstable hemodynamics, it may be difficult to treat it, despite efforts to ensure the appropriate AUC/MIC and therapeutic vancomycin concentration levels.

8.
Case Rep Infect Dis ; 2023: 5574769, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37065978

RESUMEN

An 80-year-old woman underwent pancreatoduodenectomy. Post-operation, she experienced a fever, and a culture of blood revealed metallo-beta-lactamase-producing Raoultella ornithinolytica. For treatments with aminoglycoside antimicrobial agents, a therapeutic drug monitoring-based dosing design can lower the risk of adverse events and enable appropriate treatment. Key Clinical Message. When aminoglycoside antimicrobial agents are administered for MBL-producing bacteremia, prescription suggestions based on TDM by antimicrobial stewardship team can reduce the occurrence of adverse events and enable appropriate treatment.

9.
Acute Med Surg ; 10(1): e832, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36895321

RESUMEN

Background: Hematocolpos due to imperforate hymen is an important differential diagnosis of abdominal pain in early adolescent stage. However, hematocolpos due to lower vaginal agenesis must be considered because the management differs. Case Presentation: A healthy 11-year-old girl presented with a 2-day left lower abdominal pain history. Her breast development had begun, but she had not reached menarche. Computed tomography showed high absorptive value liquid filling the upper vaginal to uterine cavity, a pale highly absorptive fluid component suggestive of hemorrhagic ascites in the abdominal cavity on both sides of the uterus, and normal bilateral ovaries. Magnetic resonance imaging diagnosed hematocolpos due to lower vaginal agenesis. The blood clot was aspirated with a transabdominal ultrasound-guided transvaginal puncture. Conclusion: History-taking, imaging tests, and appropriate collaboration with obstetrician/gynecologist with awareness of secondary sexual characteristics were crucial in this case.

10.
Int J Gen Med ; 16: 3713-3719, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37641628

RESUMEN

Purpose: Whether the coronavirus disease 2019 (COVID-19) pandemic had any effect on the time between blood culture collection and administration of antibiotics in the outpatient Department of Emergency Medicine in a single university hospital in Japan was investigated, and the intervention carried out by the antimicrobial stewardship team (AST) to promote the appropriate use of antibiotics was examined. Patients and Methods: The monthly percentage of patients who visited the outpatient Department of Emergency Medicine between January 2019 and December 2021 and received an intravenous antibiotic within 3 hours of blood culture collection was calculated. The AST calculated a quality indicator (QI) based on the results of the investigation and started QI monitoring and hospital feedback. Results: From January 2020 to March 2021 (the third COVID-19 wave), the implementation rate of antibiotic administration within 3 hours after blood culture collection decreased as the COVID-19 pandemic spread, and the implementation rate tended to increase as the number of COVID-19-positive patients decreased. However, when the AST started monitoring and feedback from April 2021, although there was a temporary decline in the early stages of the fifth wave when the scale of infection was large, the implementation rate rose and was maintained by AST intervention. (the fourth and the fifth COVID-19 waves) (P<0.01). Also, the implementation rate was significantly lower during the COVID-19 pandemic than during the non- pandemic (P<0.05). Conclusion: The early COVID-19 pandemic may have affected the delay in time from blood culture collection to antibiotic administration. Later, in recurring COVID-19 pandemics, AST intervention eliminated this problem. When a bacterial infection such as sepsis is suspected, delayed treatment can be prevented by promptly collecting a blood culture, irrespective of concerns about COVID-19 infection. Calculating the QI may promote AST activities and the appropriate use of antibiotics.

11.
J Microbiol Biol Educ ; 23(3)2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36532224

RESUMEN

Antimicrobial resistance (AMR) is a global threat to human health. Education on antibiotics is essential for AMR prevention, and training should be provided for undergraduate pharmacy students. This study evaluated the knowledge regarding antibiotic use and AMR among fourth-year Japanese pharmacy students and the effect of a lecture on treating infectious diseases with antibiotics had on their knowledge. A questionnaire survey was conducted, and the responses were recorded before and after participants attended the lecture. A small subset of the prelecture survey questions was used for the postlecture survey. From a total of 540 participants, 330 and 234 responses were collected before and after the lecture, respectively. In the prelecture survey, 39.4% of the participants incorrectly answered that antibiotics can effectively treat the common cold, 13.3% had taken leftover antibiotics, and 17.3% had taken antibiotics prescribed for their family members or others. Furthermore, the prelecture survey data showed that the mean number (± standard deviation) of correct answers across the eight questions on treatment and diagnosis of infectious diseases and antibiotics was 2.21 ± 1.64. However, in the postsurvey, this figure increased to 5.00 ± 1.82. Although the lecture improved their knowledge to some extent, the results suggested that fourth-year pharmacy students have inaccurate knowledge regarding the appropriate use of antibiotics and AMR. Therefore, it is necessary to improve early-year undergraduate pharmacy education on antibiotics in Japan.

12.
Medicine (Baltimore) ; 101(8): e28945, 2022 Feb 25.
Artículo en Inglés | MEDLINE | ID: mdl-35212303

RESUMEN

BACKGROUND: Rapid-onset, acute hypernatremia caused by sodium overload is a rare, life-threatening condition. Although experts recommend rapid correction of sodium concentration [Na] based on pathophysiological theories, only a few reports have documented the specific details of sodium correction methods. The objective of this study was to systematically review the reported treatment regimens, achieved [Na] correction rates, and treatment outcomes. METHODS: PubMed, Ichushi-database, and references without language restrictions, from inception to January 2021, were searched for studies that described ≥1 adult (aged ≥18 years) patients with rapid-onset hypernatremia caused by sodium overload, whose treatment was initiated ≤12 hours from the onset. The primary outcome of interest was the [Na] correction rate associated with mortality. RESULTS: Eighteen case reports (18 patients; median [Na], 180.5 mEq/L) were included. The cause of sodium overload was self-ingestion in 8 patients and iatrogenic sodium gain in 10 patients; baseline [Na] and symptoms at presentation were comparable for both groups. Individualized rapid infusion of dextrose-based solutions was the most commonly adopted fluid therapy, whereas hemodialysis was also used for patients already treated with hemodialysis. The correction rates were more rapid in 13 successfully treated patients than in 5 fatal patients. The successfully treated patients typically achieved [Na] ≤160 within 8 hours, [Na] ≤150 within 24 hours, and [Na] ≤145 within 48 hours. Hyperglycemia was a commonly observed treatment-related adverse event. CONCLUSION: The limited empirical evidence derived from case reports appears to endorse the recommended, rapid, and aggressive sodium correction using dextrose-based hypotonic solutions.


Asunto(s)
Fluidoterapia/métodos , Hipernatremia/terapia , Sodio en la Dieta/envenenamiento , Alimentos de Soja/envenenamiento , Adolescente , Adulto , Fluidoterapia/efectos adversos , Glucosa , Humanos , Hipernatremia/inducido químicamente , Infusiones Intravenosas , Concentración Osmolar , Sodio , Resultado del Tratamiento
13.
Case Rep Infect Dis ; 2022: 8725102, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35313466

RESUMEN

A 56-year-old woman with a history of connective tissue disease developed fever, and Bacillus cereus (B. cereus) was detected in blood cultures. Therefore, treatment with vancomycin (VCM) was initiated. Since her blood cultures persistently detected B. cereus despite peripheral intravenous catheter replacement and VCM treatment, concomitant treatment with gentamicin (GM) was started. Blood cultures then became negative. Persistent B. cereus bacteremia responded to combination therapy with VCM and GM. This combination therapy may increase the risk of developing renal dysfunction, but the risk can be mitigated by appropriate therapeutic drug monitoring (TDM) and dose adjustments to achieve successful treatment.

14.
Masui ; 60(9): 1101-3, 2011 Sep.
Artículo en Japonés | MEDLINE | ID: mdl-21950047

RESUMEN

Respiratory management for patients with a giant bulla during anesthesia should avoid positive-pressure ventilation to reduce the risk of barotraumas. We report a case of anesthetic management of a 42-year-old man with a giant bulla who had an elective surgery for biopsy of a tumor on his left elbow. Balanced anesthesia consisting of general anesthesia was given under spontaneous breathing combined with interscalene brachial plexus blockade for intra- and postoperative analgesia for the elbow surgery. The patient was monitored by electrocardiography, non-invasive arterial pressure, SpO2, endtidal CO2 tension and bispectral index. Ultrasound-guided interscalene block was performed with the patient awake. After injection of 0.75% ropivacaine 20 ml and 1% lidocaine 16 ml for brachial plexus block, general anesthesia was induced with a bolus of fentanyl 100 microg to reduce cough reflex and propofol using target control infusion with a 2 microg x ml(-1) plasma concentration. The airway was maintained with a size 4 LMA-Proseal, which was inserted with care under spontaneous breathing. There were no serious complications such as pneumothorax in perioperative period. We performed successful anesthetic management, without any complications, combined with interscalene brachial plexus block and spontaneous breathing in a patient with a giant bulla.


Asunto(s)
Anestesia General/métodos , Vesícula/complicaciones , Plexo Braquial , Enfermedades Pulmonares/complicaciones , Bloqueo Nervioso , Respiración , Adulto , Codo , Humanos , Masculino , Neoplasias de los Tejidos Blandos/cirugía
15.
Acute Med Surg ; 7(1): e611, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33318805

RESUMEN

BACKGROUND: Among the influenza-associated encephalopathies, acute necrotizing encephalopathy (ANE) has a particularly poor prognosis. While it usually progresses within 48 h, we encountered a rapidly evolving case with the patient falling into coma from lucidity within 10 min. CASE PRESENTATION: A 71-year-old man was found unconscious after taking a 10-min bath and brought to the emergency room. The head computed tomography (HCT) was normal, and he was diagnosed with heatstroke as a complication of influenza A. Despite effective therapy to correct his temperature, his consciousness did not improve, and within 24 h he progressed to multiple organ injury. Repeat HCT and subsequent magnetic resonance imaging revealed irreparably progressed ANE. CONCLUSION: To effectively treat ANE, early recognition and diagnosis are critical. Our case suggests that ANE should be considered and added to the differential diagnosis for adult patients with rapid cognitive deterioration.

16.
Anesth Analg ; 109(3): 754-9, 2009 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-19690242

RESUMEN

BACKGROUND: Internal jugular vein (IJV) catheterization in pediatric patients is sometimes difficult because of the small sizes of veins and their collapse during catheterization. To facilitate IJV catheterization, we developed a novel skin-traction method (STM), in which the point of puncture of the skin over the IJV is stretched upward with tape during catheterization. In this study, we examined whether the STM increases the cross-sectional area of the vein and thus facilitates catheterization. METHODS: This was a prospective study conducted from December 2006 to June 2008. We enrolled 28 consecutive infants and neonates weighing <5 kg who underwent surgery for congenital heart disease. The patients were randomly assigned to a group in which STM was performed (STM group) or a group in which it was not performed (non-STM group). The cross-sectional area and diameter of the right IJV in the flat position and 10 degrees Trendelenburg position with and without applying STM were measured. We determined time from first skin puncture to the following: (a) first blood back flow, (b) insertion of guidewire, and (c) insertion of catheter. Number of punctures, success rate, complications, and degree of IJV collapse during advancement of the needle (estimated as decrease of anteroposterior diameter during advancement of the needle compared with the diameter before advancement) were also examined. RESULTS: STM significantly increased the cross-sectional area and the anteroposterior diameter of the IJV in both positions. The time required to insert the catheter was significantly shorter in the STM group, probably mainly due to a shorter guidewire insertion time. The degree of IJV collapse during advancement of the needle was much lower in the STM group. CONCLUSIONS: STM facilitates IJV catheterization in infants and neonates weighing <5 kg by enlarging the IJV and preventing vein collapse.


Asunto(s)
Cateterismo Venoso Central/métodos , Venas Yugulares/anatomía & histología , Tracción/métodos , Ultrasonografía/métodos , Anestesiología/métodos , Femenino , Cardiopatías/congénito , Cardiopatías/cirugía , Humanos , Lactante , Recién Nacido , Venas Yugulares/diagnóstico por imagen , Masculino , Estudios Prospectivos , Piel
17.
J Anesth ; 23(4): 587-90, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-19921372

RESUMEN

A 53-year-old man with mitochondrial disease underwent gastrectomy because of gastric cancer. Three days after the surgery, he developed severe hyponatremia (Na, 106 mmol l(-1)) together with hypovolemic shock and lactic acidosis. Despite the hyponatremia, his urine sodium concentration was high, suggesting renal salt wasting. Although mitochondrial diseases are not common and hyponatremia in patients with these diseases is not well known, clinicians should pay close attention to serum sodium levels and maintain them properly.


Asunto(s)
Hiponatremia/etiología , Hiponatremia/terapia , Síndrome MELAS/complicaciones , Enfermedades Mitocondriales/complicaciones , Complicaciones Posoperatorias/terapia , Acidosis Láctica/complicaciones , Acidosis Láctica/terapia , Anestesia , Gastrectomía , Humanos , Masculino , Persona de Mediana Edad , Choque/complicaciones , Choque/terapia , Neoplasias Gástricas/cirugía , Equilibrio Hidroelectrolítico/fisiología
18.
J Anesth ; 23(1): 93-8, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-19234830

RESUMEN

PURPOSE: We aimed to introduce a simple, lightweight continuous positive airway pressure (CPAP)-delivery device for the nondependent lung during one-lung ventilation, to investigate how the type of three-way stopcocks, and the compliance and resistance of a test lung affect the relationship between the oxygen flow rate and CPAP level produced, and to examine how the device works in a clinical setting. METHODS: In the test lung study, the bronchial blocker of a Univent tube was connected to a test lung. The effects of oxygen-flow rate, types of three-way stopcocks, and compliance and resistance of the test lung on the CPAP levels were studied. In the clinical study, the lightweight device was used to treat hypoxia in seven patients during one-lung ventilation with the bronchial blocker. RESULTS: In the test lung study, the CPAP level produced by the device was proportional to the oxygen-flow rate, dependent on the type of three-way stopcock used, and independent of the compliance or resistance of the test lung. There was no discrepancy between the plateau pressures of the test lung and the monitoring port of an additional stopcock at any degree of compliance or resistance of the test lung at any oxygen-flow rate. Therefore, the relationship between the oxygen-flow rate and CPAP level can be ensured in advance before application to the lung, with an additional three-way stopcock of which the distal end is occluded. In the clinical study, peripheral oxygen sataration Sp(O2) improved while the CPAP level ranged from 2.8 to 5.4 cmH2O. CONCLUSION: The lightweight CPAP delivery-device can provide variable CPAP levels by adjusting the oxygen-flow rate without real-time monitoring of the pressure.


Asunto(s)
Presión de las Vías Aéreas Positiva Contínua/instrumentación , Pulmón/fisiología , Respiración Artificial/instrumentación , Presión del Aire , Resistencia de las Vías Respiratorias/fisiología , Humanos , Rendimiento Pulmonar/fisiología , Oxígeno/administración & dosificación , Oxígeno/sangre
19.
J Anesth ; 23(2): 230-4, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-19444562

RESUMEN

PURPOSE: Owing to recent advances in surgical technology, substantial time is required for preparing surgical equipment before incision. The purpose of this study was to demonstrate the time progression from a patient's operating room entrance to incision and to evaluate the duration of each anesthetic procedure and surgical preparation. METHODS: We marked the following seven points on the anesthetic chart: (1) entrance; (2) i.v. line placement; (3) preoxygenation; (4) intubation; (5) completion of patient positioning (Anesth-Set); (6) applying antiseptic solution; and (7) incision. Afterward, we analyzed the event time periods according to anesthetic procedure, patient position, surgical service, and surgical procedure (such as the utilization of endoscopy, navigation systems, and sentinel lymph node biopsy). RESULTS: On average, it took approximately 3 min to start i.v. placement, 7 min until preoxygenation, 15 min until intubation, and 30 min until Anesth-Set. Epidural, arterial, and central venous catheterization required 15, 9, and 13 min, respectively. It took 20 min from Anesth-Set to incision, on average; 22, 4, and 5 min were required to prepare the navigation system, endoscope, and sentinel lymph node biopsy, respectively. In total, it took an average of 49.8 +/- 17.1 min from entrance to incision, which was significantly longer (30.4 +/- 8.8 min) than it took in 1985-1986. CONCLUSION: The mean time taken from the patient's operating room entrance to incision is now significantly longer than before. This may be attributed, at least in part, to the preparation of equipment associated with new surgical technologies.


Asunto(s)
Anestesia General , Quirófanos/organización & administración , Atención Perioperativa/métodos , Antiinfecciosos Locales/administración & dosificación , Humanos , Infusiones Intravenosas , Intubación Intratraqueal , Postura , Medicación Preanestésica , Estudios Retrospectivos , Procedimientos Quirúrgicos Operativos , Factores de Tiempo
20.
J Anesth ; 23(1): 41-5, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-19234821

RESUMEN

PURPOSE: Real-time ultrasound-assisted guidance for catheterization of the internal jugular vein (IJV) is known to be useful, especially for a small-sized vein, which is difficult to catheterize. However, one of the problems with real-time ultrasound-assisted guidance is that the ultrasound probe itself can collapse the vein. We have developed a novel "skintraction method (STM)", in which the puncture point of the skin over the IJV is stretched upwards with several pieces of surgical tape in the cephalad and caudal directions with the aim being to facilitate catheterization of the IJV. We examined whether this method increased the compressive force required to collapse the IJV. METHODS: In ten volunteers, the compressive force required to collapse the right IJV, and the cross-sectional area and anteroposterior and transverse diameters of the IJV were measured with ultrasound imaging in the supine position (SP) with or without the STM or in the Trendelenburg position of 10 degrees head-down (TP) without the STM. RESULTS: The compressive force to required to collapse the vein was increased significantly with the STM, while the crosssectional area and anteroposterior diameter of the vein in the SP with STM were similar to those in the TP without the STM. CONCLUSION: With the STM, not only the cross-sectional area but also the compressive force required to collapse the IJV increased. Thus, the STM may facilitate real-time ultrasoundassisted guidance for catheterization of the IJV by maintaining the cross-sectional area of the vein during the guidance.


Asunto(s)
Cateterismo Periférico/métodos , Venas Yugulares/diagnóstico por imagen , Venas Yugulares/fisiología , Fenómenos Fisiológicos de la Piel , Ultrasonido/efectos adversos , Adulto , Femenino , Inclinación de Cabeza , Humanos , Venas Yugulares/anatomía & histología , Masculino , Persona de Mediana Edad , Presión , Posición Supina , Ultrasonografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA