Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 360
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Circulation ; 148(18): 1354-1367, 2023 10 31.
Artículo en Inglés | MEDLINE | ID: mdl-37638389

RESUMEN

BACKGROUND: The circuit boundaries for reentrant ventricular tachycardia (VT) have been historically conceptualized within a 2-dimensional (2D) construct, with their fixed or functional nature unresolved. This study aimed to examine the correlation between localized lines of conduction block (LOB) evident during baseline rhythm with lateral isthmus boundaries that 3-dimensionally constrain the VT isthmus as a hyperboloid structure. METHODS: A total of 175 VT activation maps were correlated with isochronal late activation maps during baseline rhythm in 106 patients who underwent catheter ablation for scar-related VT from 3 centers (42% nonischemic cardiomyopathy). An overt LOB was defined by a deceleration zone with split potentials (≥20 ms isoelectric segment) during baseline rhythm. A novel application of pacing within deceleration zone (≥600 ms) was implemented to unmask a concealed LOB not evident during baseline rhythm. LOB identified during baseline rhythm or pacing were correlated with isthmus boundaries during VT. RESULTS: Among 202 deceleration zones analyzed during baseline rhythm, an overt LOB was evident in 47%. When differential pacing was performed in 38 deceleration zones without overt LOB, an underlying concealed LOB was exposed in 84%. In 152 VT activation maps (2D=53, 3-dimensional [3D]=99), 69% of lateral boundaries colocalized with an LOB in 2D activation patterns, and the depth boundary during 3D VT colocalized with an LOB in 79%. In VT circuits with isthmus regions that colocalized with a U-shaped LOB (n=28), the boundary invariably served as both lateral boundaries in 2D and 3D. Overall, 74% of isthmus boundaries were identifiable as fixed LOB during baseline rhythm or differential pacing. CONCLUSIONS: The majority of VT circuit boundaries can be identified as fixed LOB from intrinsic or paced activation during sinus rhythm. Analysis of activation while pacing within the scar substrate is a novel technique that may unmask concealed LOB, previously interpreted to be functional in nature. An LOB from the perspective of a myocardial surface is frequently associated with intramural conduction, supporting the existence of a 3D hyperboloid VT circuit structure. Catheter ablation may be simplified to targeting both sides around an identified LOB during sinus rhythm.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Humanos , Cicatriz , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía , Arritmias Cardíacas , Frecuencia Cardíaca/fisiología , Bloqueo Cardíaco
2.
J Cardiovasc Electrophysiol ; 35(1): 198-205, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38037864

RESUMEN

INTRODUCTION: The major limitation of the current cryoballoon (CB) system is a fixed 28 mm balloon-size. We sought to analyze real-world early experience with novel-sized adjustable CB. METHODS: This multicenter observational study included 140 consecutive atrial fibrillation patients (71 years, 94 men, 86 paroxysmal) who underwent pulmonary vein (PV) isolation using expandable diameter CB capable of ablation at 28 or 31 mm. RESULTS: Out of 544 targeted PVs, 526 (96.7%) were successfully isolated by a size-adjustable CB with a 770 [690-870] second median application dose, while the remaining 18 required touch-up ablation. Among them, 326 (62.0%) PVs were isolated by a 31 mm balloon, and the rate was significantly higher for upper than lower PVs (73.0% vs. 45.7%, p < .0001) and highest for right superior (78.5%) and lowest for right inferior (39.9%) PVs. The biophysical parameters and time to isolation were comparable between the 28 and 31 mm balloons, however, the real-time PV potential monitoring capability was significantly higher for 31 mm than 28 mm balloons for the left superior PV. The esophageal temperature reached 15°C during left inferior PV ablation significantly more often with 31 mm than 28 mm balloons (43.1% vs. 18.2%, p = .008). Right phrenic nerve injury (PNI) occurred in 9 (6.4%) patients during applications (6 right superior, 2 right inferior PVs), and most occurred with a 31 mm balloon. CONCLUSIONS: Our real-world early data demonstrated high acute efficacy and safety of the novel-sized adjustable CB. The biophysical parameters were similar between the 28 and 31 mm balloons. No marked decrease in the incidence of PNI was observed even with 31 mm balloons.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Masculino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/epidemiología , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Criocirugía/efectos adversos , Criocirugía/métodos , Venas Pulmonares/cirugía , Resultado del Tratamiento , Femenino
3.
Artículo en Inglés | MEDLINE | ID: mdl-39324850

RESUMEN

INTRODUCTION: Typical atrial flutter (AFL) is a macroreentrant tachycardia in which intracardiac conduction rotates counterclockwise around the tricuspid annulus. Typical AFL has specific electrocardiographic characteristics, including a negative sawtooth-like wave in the inferior lead and a positive F wave in lead V1. This study aimed to analyze the origin of the positive F wave in lead V1, which has not been completely understood. METHODS: This study enrolled 10 patients who underwent radiofrequency catheter ablation for a typical AFL. Electroanatomical mapping was performed both during typical AFL and entrainment from the right atrial appendage (RAA). The 12-lead electrocardiogram (ECG) and three-dimensional (3D) electroanatomical maps were analyzed. RESULTS: The positive F wave in lead V1 changed during entrainment from the RAA in all the cases. The 3D map during entrainment from the RAA revealed an area of antidromic capture around the RAA, which collided with the orthodromic wave in the anterior right atrium. This area of antidromic capture around the RAA was the only difference from the 3D electroanatomical map of AFL and is considered the cause of the change in the F wave in lead V1 during entrainment. CONCLUSION: The analysis of the differences in the 12-lead ECG and 3D maps between tachycardia and entrainment from the RAA clearly demonstrated that activation around the RAA is responsible for the generation of the positive F wave in lead V1 of typical AFL.

4.
Artículo en Inglés | MEDLINE | ID: mdl-39169533

RESUMEN

INTRODUCTION: The novel cryoballoon with 28 mm or 31 mm adjustable diameters, aims to achieve a wide antral pulmonary vein isolation (PVI). However, the distribution of antral lesions and their variations based on left atrial (LA) remodeling require further clarification. METHODS: We evaluated 22 patients (67 [59.5-74.8] years, 19 males) who underwent PVI of atrial fibrillation (AF) (13 paroxysmal AF [PAF] and 9 non-PAF) using size-adjustable cryoballoons. LA electro-anatomical mapping was performed post-PVI with three-dimensional mapping systems. We assessed the shapes of the LA and pulmonary veins (PVs) and the distribution of isolated areas (IAs), comparing the results between PAF and non-PAF patients. RESULTS: In the left PVs (LPVs), the distance between the PV orifice and IA edge (PVos-IA) was larger on the roof and posterior segments (~15 mm) but relatively smaller on the anterior segment near the PV ridge (<10 mm). For the right PVs (RPVs), it was more extensive in the posterior segment (10-15 mm). Comparing PAF and non-PAF, there were no significant differences in the PVos-IA except for the right posterior-carina segment, antrum IA (LPVs: 5.9 ± 1.6 vs. 5.8 ± 0.8 cm², p = .81; RPVs: 4.8 ± 2.3 vs. 4.8 ± 1.2 cm², p = .81), distances between the right and left IAs on the LA posterior wall (LAPW), and un-isolated LAPW area (9.0 ± 4.9 vs. 9.9 ± 2.5 cm², p = .62). No individual PVIs were observed in either group. Two patients exhibited overlapping IAs on the roof, and one patient who underwent 31 mm balloon applications for all PVs exhibited an LAPW isolation. CONCLUSION: The size-adjustable cryoballoon achieved a wide antral PVI even in non-PAF patients.

5.
J Cardiovasc Electrophysiol ; 35(3): 505-510, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38178380

RESUMEN

INTRODUCTION: Dual atrioventricular nodal non-reentrant tachycardia (DAVNNT) is a rare and challenging-to-diagnose arrhythmia, without previous reports associating it with a leftward inferior extension (LIE). METHODS: Diagnosis was made using adenosine triphosphate (ATP) injection during atrial pacing in a suspected DAVNNT patient. RESULTS: Ablation of the rightward inferior extension was unsuccessful in eliminating DAVNNT; however, subsequent ablation of the LIE successfully eradicated the arrhythmia. CONCLUSION: This unique case, marked by the first instance of DAVNNT caused by LIE, diagnosed through ATP injection, underscores the utility of this diagnostic approach and broadens the spectrum of our understanding and management of this condition.


Asunto(s)
Ablación por Catéter , Polifosfatos , Taquicardia por Reentrada en el Nodo Atrioventricular , Humanos , Adenosina Trifosfato , Nodo Atrioventricular , Ablación por Catéter/efectos adversos , Taquicardia por Reentrada en el Nodo Atrioventricular/diagnóstico , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía , Adenosina , Arritmias Cardíacas , Electrocardiografía
6.
J Cardiovasc Electrophysiol ; 35(6): 1129-1139, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38556747

RESUMEN

INTRODUCTION: Recent studies have reported the efficacy of the cryoballoon (CB)-guided left atrial roof block line (LARB) creation in patients with persistent atrial fibrillation (AF). However, it can be technically challenging to attach the balloon to the left atrial (LA) roof due to its anatomical variations. We designed a new procedure called the "Raise-up Technique," which may facilitate the firm adhesion of the CB to the LA roof during freezing. This study aimed to evaluate the efficacy of the Raise-up technique in LARB creation. METHODS AND RESULTS: In total, 100 consecutive patients with persistent AF who underwent CB-LARB creation were enrolled. Fifty-seven patients underwent LARB creation using the Raise-up technique (Raise-up group), and the remaining 43 did not use it (control group). The Raise-up technique was performed as follows: An Achieve catheter was inserted as deeply as possible into the upper branch of the right superior pulmonary vein to anchor the CB. The balloon was placed below the targeted site on the LA roof and frozen. When the temperature of the CB reached approximately -10°C and the CB was easier to attach to the LA tissue, the CB was raised and pressed against the LA roof immediately by sheath advancement. Then the balloon could be in firm contact with the target site on the roof. If necessary, additional sheath advancement after sufficient freezing (-20°C to -30°C) was allowed the CB to have more firm and broad contact with the target site. LARB creation without touch-up ablation was achieved in 54 of 57 patients (94.7%) in the Raise-up group and 33 of 43 patients (76.7%) in the control group (p < .05). The lesion size of the LARB in the Raise-up group was significantly larger than that in the control group (15.2 cm2 vs. 12.8 cm2, p < .05). Moreover, the width of the LARB lesion in the Raise-up group was wider than that in the control group (32.0 mm vs. 26.6 mm, p < .05). CONCLUSION: The Raise-up technique enabled the creation of seamless and thick LARB lesions with a single stroke. In addition, the CB-LARB lesions created using the Raise-up technique tended to be large, resulting in extensive debulking of the LA posterior wall arrhythmia substrates. In CB ablation for persistent AF, the Raise-up technique can be considered one of the key strategies for LARB creation.


Asunto(s)
Fibrilación Atrial , Criocirugía , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Criocirugía/instrumentación , Femenino , Masculino , Persona de Mediana Edad , Anciano , Resultado del Tratamiento , Atrios Cardíacos/cirugía , Atrios Cardíacos/fisiopatología , Atrios Cardíacos/diagnóstico por imagen , Potenciales de Acción , Frecuencia Cardíaca , Factores de Tiempo , Estudios Retrospectivos , Recurrencia , Venas Pulmonares/cirugía , Venas Pulmonares/fisiopatología
7.
Artículo en Inglés | MEDLINE | ID: mdl-39188036

RESUMEN

BACKGROUND: Safety data of the latest radiofrequency (RF) technologies during atrial fibrillation (AF) ablation in real-world clinical practice are limited. OBJECTIVES: We sought to evaluate the acute procedural safety of the four latest ablation catheters commonly used for AF ablation. METHODS: A total of 3957 AF ablation procedures performed between January 2022 and December 2023 at 20 centers with either the THERMOCOOL SMARTTOUCH SF (STSF), TactiCath (TC), QDOT Micro (QDM), or TactiFlex (TF) were retrospectively analyzed. RESULTS: In total, QDM, STSF, TF, and TC were used in 343 (8.7%), 1793 (45.3%), 1121 (28.4%), and 700(17.7%) procedures. Among 2406 index procedures, electrical pulmonary vein isolations were successfully achieved in 99.5%. Despite similar total procedure times in the four groups, the total fluoroscopic time was significantly shorter for QDM/STSF with CARTO than TF/TC with EnSite (18.7 ± 14 vs. 27.6 ± 20.6 min, p < .001) and longest in the TF group. The incidence of cardiac tamponade was 0.7% (0.5% and 0.9% during index and redo procedures, 0.8% and 0.3% for paroxysmal and non-paroxysmal AF) and was significantly lower for QDM/STSF than TF/TC (0.2% vs. 1.1%, p = .008) and highest in the TF group. The incidence of cardiac tamponade was higher for TF than TC and STSF than QDM. In the multivariate analysis, TF/TC with EnSite was a significant independent predictor of cardiac tamponade during both the index (odds ratio [OR] = 4.8, 95% confidence interval [CI] = 1.3-17.5, p = .02) and all procedures (OR = 3.0, 95% CI = 1.3-7.2, p = .01). CONCLUSIONS: The incidence of cardiac tamponade and the fluoroscopic time during AF ablation significantly differed among the latest RF catheters and mapping systems in real-world clinical practice.

8.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38588039

RESUMEN

AIMS: Phrenic nerve injury (PNI) is the most common complication during cryoballoon ablation. Currently, two cryoballoon systems are available, yet the difference is unclear. We sought to compare the acute procedural efficacy and safety of the two cryoballoons. METHODS: This prospective observational study consisted of 2,555 consecutive atrial fibrillation (AF) patients undergoing pulmonary vein isolation (PVI) using either conventional (Arctic Front Advance) (AFA-CB) or novel cryoballoons (POLARx) (POLARx-CB) at 19 centers between January 2022 and October 2023. RESULTS: Among 2,555 patients (68.8 ± 10.9 years, 1,740 men, paroxysmal AF[PAF] 1,670 patients), PVIs were performed by the AFA-CB and POLARx-CB in 1,358 and 1,197 patients, respectively. Touch-up ablation was required in 299(11.7%) patients. The touch-up rate was significantly lower for POLARx-CB than AFA-CB (9.5% vs. 13.6%, p = 0.002), especially for right inferior PVs (RIPVs). The touch-up rate was significantly lower for PAF than non-PAF (8.8% vs. 17.2%, P < 0.001) and was similar between the two cryoballoons in non-PAF patients. Right PNI occurred in 64(2.5%) patients and 22(0.9%) were symptomatic. It occurred during the right superior PV (RSPV) ablation in 39(1.5%) patients. The incidence was significantly higher for POLARx-CB than AFA-CB (3.8% vs. 1.3%, P < 0.001) as was the incidence of symptomatic PNI (1.7% vs. 0.1%, P < 0.001). The difference was significant during RSPV (2.5% vs. 0.7%, P < 0.001) but not RIPV ablation. The PNI recovered more quickly for the AFA-CB than POLARx-CB. CONCLUSIONS: Our study demonstrated a significantly higher incidence of right PNI and lower touch-up rate for the POLARx-CB than AFA-CB in the real-world clinical practice.


Asunto(s)
Fibrilación Atrial , Criocirugía , Traumatismos de los Nervios Periféricos , Nervio Frénico , Venas Pulmonares , Sistema de Registros , Humanos , Nervio Frénico/lesiones , Masculino , Femenino , Fibrilación Atrial/cirugía , Fibrilación Atrial/epidemiología , Venas Pulmonares/cirugía , Anciano , Criocirugía/efectos adversos , Criocirugía/métodos , Estudios Prospectivos , Incidencia , Traumatismos de los Nervios Periféricos/etiología , Traumatismos de los Nervios Periféricos/epidemiología , Traumatismos de los Nervios Periféricos/prevención & control , Persona de Mediana Edad , Resultado del Tratamiento , Ablación por Catéter/efectos adversos
9.
Circ J ; 2024 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-39358305

RESUMEN

BACKGROUND: Implantable cardioverter defibrillators (ICDs) reduce mortality associated with ventricular arrhythmia in high-risk patients with cardiovascular disease. Machine learning (ML) approaches are promising tools in arrhythmia research; however, their application in predicting ventricular arrhythmias in patients with ICDs remains unexplored. We aimed to predict and stratify ventricular arrhythmias requiring ICD therapy using 12-lead electrocardiograms (ECGs) in patients with an ICD. METHODS AND RESULTS: This retrospective analysis included 200 adult patients who underwent ICD implantation at a single center. Patient demographics, clinical features, and 12-lead ECG data were collected. Unsupervised learning techniques, including K-means and hierarchical clustering, were used to stratify patients based on 12-lead ECG features. Dimensionality reduction methods were also used to optimize clustering accuracy. The silhouette coefficient was used to determine the optimal method and number of clusters. Of the 200 patients, 59 (29.5%) received appropriate therapy. The mean age of patients was 62.3 years, and 81.0% were male. The mean follow-up period was 2,953 days, with no significant intergroup differences. Hierarchical clustering into 3 clusters proved to be the most accurate (silhouette coefficient=0.585). Kaplan-Meier curves for these 3 clusters revealed significant differences (P=0.026). CONCLUSIONS: We highlight the potential of ML-based clustering using 12-lead ECGs to help in the risk stratification of ventricular arrhythmia. Future research in a larger multicenter setting may provide further insights and refine ICD indications.

10.
Circ J ; 88(11): 1842-1852, 2024 Oct 25.
Artículo en Inglés | MEDLINE | ID: mdl-38763754

RESUMEN

BACKGROUND: Myocardial bridge (MB) is a common coronary anomaly characterized by a tunneled course through the myocardium. Coronary computed tomography angiography (CCTA) can identify MB. The impact of MB detected by CCTA on coronary physiological parameters before and after percutaneous coronary intervention (PCI) is unknown. METHODS AND RESULTS: We investigated 141 consecutive patients who underwent pre-PCI CCTA and fractional flow reserve (FFR)-guided elective PCI for de novo single proximal lesions in the left anterior descending artery (LAD). We compared clinical demographics and physiological parameters between patients with and without CCTA-defined MB. MB was identified in 46 (32.6%) patients using pre-PCI CCTA. The prevalence of diabetes was higher among patients with MB. Median post-PCI FFR values were significantly lower among patients with than without MB (0.82 [interquartile range 0.79-0.85] vs. 0.85 [interquartile range 0.82-0.89]; P=0.003), whereas pre-PCI FFR values were similar between the 2 groups. Multivariable linear regression analysis revealed that the presence of MB and greater left ventricular mass volume in the LAD territory were independently associated with lower post-PCI FFR values. Multivariable logistic regression analysis also revealed that the presence of MB and lower pre-PCI FFR values were independent predictors of post-PCI FFR values ≤0.80. CONCLUSIONS: CCTA-defined MB independently predicted both lower post-PCI FFR as a continuous variable and ischemic FFR as a categorical variable in patients undergoing elective PCI for LAD.


Asunto(s)
Reserva del Flujo Fraccional Miocárdico , Puente Miocárdico , Intervención Coronaria Percutánea , Humanos , Masculino , Femenino , Anciano , Persona de Mediana Edad , Puente Miocárdico/fisiopatología , Puente Miocárdico/diagnóstico por imagen , Angiografía Coronaria , Angiografía por Tomografía Computarizada , Estudios Retrospectivos
11.
Circ J ; 88(11): 1788-1797, 2024 Oct 25.
Artículo en Inglés | MEDLINE | ID: mdl-38897975

RESUMEN

BACKGROUND: Abnormal coronary microcirculation is linked to poor patient prognosis, so the aim of the present study was to assess the prognostic relevance of basal microvascular resistance (b-IMR) in patients without functional coronary stenosis. METHODS AND RESULTS: Analyses of 226 patients who underwent intracoronary physiological assessment of the left anterior descending artery included primary endpoints of all-cause death and heart failure, as well as secondary endpoints of cardiovascular death and atherosclerotic vascular events. During a median follow-up of 2 years, there were 12 (5.3%) primary and 21 (9.3 %) secondary endpoints. The optimal b-IMR cutoff for the primary endpoints was 47.1 U. Kaplan-Meier curve analysis demonstrated worse event-free survival of the primary endpoints in patients with a b-IMR below the cutoff (χ2=21.178, P<0.001). b-IMR was not significantly associated with the secondary endpoints (P=0.35). A low coronary flow reserve (CFR; <2.5) had prognostic value for both endpoints (primary endpoints: χ2=11.401, P=0.001; secondary endpoints: (χ2=6.015; P=0.014), and high hyperemic microvascular resistance (≥25) was associated only with the secondary endpoints (χ2=4.420; P=0.036). Incorporating b-IMR into a clinical model that included CFR improved the Net Reclassification Index and Integrated Discrimination Improvement for predicting the primary endpoints (P<0.001 and P=0.034, respectively). CONCLUSIONS: b-IMR may be a specific marker of the risk of death and heart failure in patients without functional coronary stenosis.


Asunto(s)
Insuficiencia Cardíaca , Microcirculación , Resistencia Vascular , Humanos , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Masculino , Femenino , Persona de Mediana Edad , Anciano , Circulación Coronaria , Pronóstico , Estenosis Coronaria/mortalidad , Estenosis Coronaria/fisiopatología , Vasos Coronarios/fisiopatología
12.
Circ J ; 88(11): 1853-1861, 2024 Oct 25.
Artículo en Inglés | MEDLINE | ID: mdl-38925928

RESUMEN

BACKGROUND: Recent studies suggest that the presence of calcified nodules (CN) is associated with worse prognosis in patients with acute coronary syndrome (ACS). We investigated clinical predictors of optical coherence tomography (OCT)-defined CN in ACS patients in a prospective multicenter registry. METHODS AND RESULTS: We investigated 695 patients enrolled in the TACTICS registry who underwent OCT assessment of the culprit lesion during primary percutaneous coronary intervention. OCT-CN was defined as calcific nodules erupting into the lumen with disruption of the fibrous cap and an underlying calcified plate. Compared with patients without OCT-CN, patients with OCT-CN (n=28) were older (mean [±SD] age 75.0±11.3 vs. 65.7±12.7 years; P<0.001), had a higher prevalence of diabetes (50.0% vs. 29.4%; P=0.034), hemodialysis (21.4% vs. 1.6%; P<0.001), and Killip Class III/IV heart failure (21.4% vs. 5.7%; P=0.003), and a higher preprocedural SYNTAX score (median [interquartile range] score 15 [11-25] vs. 11 [7-19]; P=0.003). On multivariable analysis, age (odds ratio [OR] 1.072; P<0.001), hemodialysis (OR 16.571; P<0.001), and Killip Class III/IV (OR 4.466; P=0.004) were significantly associated with the presence of OCT-CN. In non-dialysis patients (n=678), age (OR 1.081; P<0.001), diabetes (OR 3.046; P=0.014), and Killip Class III/IV (OR 4.414; P=0.009) were significantly associated with the presence of OCT-CN. CONCLUSIONS: The TACTICS registry shows that OCT-CN is associated with lesion severity and poor clinical background, which may worsen prognosis.


Asunto(s)
Síndrome Coronario Agudo , Sistema de Registros , Tomografía de Coherencia Óptica , Humanos , Síndrome Coronario Agudo/diagnóstico por imagen , Síndrome Coronario Agudo/terapia , Anciano , Masculino , Femenino , Persona de Mediana Edad , Anciano de 80 o más Años , Estudios Prospectivos , Intervención Coronaria Percutánea , Calcificación Vascular/diagnóstico por imagen , Calcinosis/diagnóstico por imagen , Diabetes Mellitus/epidemiología , Valor Predictivo de las Pruebas
13.
Pacing Clin Electrophysiol ; 47(1): 124-126, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37864811

RESUMEN

Recently, a novel size-adjustable cryoballoon has been introduced in clinical practice, which can be inflated to two different diameters (28 and 31 mm). The 31 mm cryoballoon is specifically designed to achieve better contact with remodeled pulmonary veins (PVs) that have wider ostia while avoiding deep cannulation, thereby potentially reducing the risk of phrenic nerve injury (PNI) associated with deep balloon cannulation. However, we encountered two cases of PNI during cryoballoon ablation using the novel system among our initial 25 consecutive case series. Herein, we present two cases that exhibited PNI during freezing of the right superior PV with a size-adjustable balloon. While larger balloons are expected to create a larger area of isolation, the safety of this novel balloon system needs to be evaluated in a large-scale clinical study.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Traumatismos de los Nervios Periféricos , Venas Pulmonares , Humanos , Fibrilación Atrial/cirugía , Nervio Frénico/lesiones , Traumatismos de los Nervios Periféricos/etiología , Traumatismos de los Nervios Periféricos/prevención & control , Traumatismos de los Nervios Periféricos/cirugía , Venas Pulmonares/cirugía , Resultado del Tratamiento
14.
Artículo en Inglés | MEDLINE | ID: mdl-39161113

RESUMEN

BACKGROUND: QRS morphology can change during ventricular arrhythmias (VAs) with the appearance of bundle branch block (BBB). METHODS: We retrospectively investigated 195 consecutive patients who underwent an initial ablation of VA. The study inclusion criteria were VAs that were successfully ablated in the outflow tract (OT) and in whom right bundle branch block (RBBB) was induced by catheter manipulation close to the His bundle area during sinus rhythm, before any radiofrequency application. We analyzed the QRS morphology of the VAs with and without RBBB during sinus beats. RESULTS: Twenty-four patients (age 59 ± 17 years, female 14) developed RBBB at some point during their procedure. The successful ablation sites of the VAs were the right ventricular outflow tract (RVOT) in 12 patients, pulmonary artery in one, left coronary cusp in five, right coronary cusp in three, right-left cusp junction in two, and great cardiac vein in two. QRS-morphology change was observed in five (20%) cases. The successful ablation sites in that group were the left coronary cusp in three cases, right coronary cusp in one, and RVOT septum in one. The QRS duration of the VAs increased during RBBB. CONCLUSIONS: There are some cases of OT-VAs in which the QRS waveform changes with the appearance of catheter induced RBBB. We need to be aware that when QRS morphology changes during an OT-VA ablation, it does not necessarily mean that the origin or exit of the VA has changed.

15.
J Obstet Gynaecol Res ; 50(1): 128-132, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37857437

RESUMEN

Limited data have been reported on the use of proprotein convertase subtilisin/kexin type 9 (PCSK 9) inhibitors during pregnancy in women with familial hypercholesterolemia (FH). Here, we present the first case of initiating evolocumab (PCSK9 inhibitor) in a compound heterozygous FH mother. The patient was a 34-year-old primipara with severe dyslipidemia and a history of coronary artery bypass surgery. An elevated low-density lipoprotein cholesterol (LDL-C) level of 420 mg/dL was detected in the first trimester and persistently increased throughout pregnancy. Evolocumab was administered at 31 and 35 weeks of gestation, showing a positive effect on stabilizing LDL-C levels. Planned delivery with labor analgesia was performed at 38 + 4 weeks. Both the mother and infant were discharged without any notable complications. Hence, evolocumab, an IgG2 monochromatic antibody with little placental permeability, may be an alternative medication with limited influence on infants. Further studies are needed to assess the safety of evolocumab administration during pregnancy.


Asunto(s)
Enfermedad de la Arteria Coronaria , Hiperlipoproteinemia Tipo II , Embarazo , Femenino , Humanos , Adulto , LDL-Colesterol/uso terapéutico , Inhibidores de PCSK9 , Proproteína Convertasa 9/uso terapéutico , Enfermedad de la Arteria Coronaria/tratamiento farmacológico , Anticuerpos Monoclonales/efectos adversos , Placenta , Hiperlipoproteinemia Tipo II/complicaciones , Hiperlipoproteinemia Tipo II/tratamiento farmacológico
16.
J Clin Ultrasound ; 52(3): 265-273, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38069627

RESUMEN

BACKGROUND: Previous studies showed that unrecognized myocardial infarction (UMI) identified on cardiac magnetic resonance (CMR) was related to worse prognosis. We aimed to investigate the efficacy of preprocedural transthoracic echocardiography (TTE) to detect the presence of UMI in patients undergoing percutaneous coronary intervention (PCI). METHODS: A total of 138 patients with chronic coronary syndrome (CCS) and preserved left ventricular ejection fraction (LVEF) without history of myocardial infarction or revascularization were retrospectively studied. UMI was evaluated with pre-PCI late gadolinium enhancement (LGE)-CMR. TTE and two-dimensional speckle-tracking echocardiography (2D-STE) were performed before PCI. All patients were divided into two groups according to the presence or absence of UMI, and clinical and echocardiographic findings were compared between these two groups. RESULTS: UMI was detected in 43 patients (31.2%). Multivariable logistic regression analysis revealed that higher SYNTAX score, the presence of wall motion abnormalities (WMAs) and lower global longitudinal strain (GLS) were independent predictors of the presence of UMI. Furthermore, GLS provided incremental efficacy for the detection of UMI over abnormal Q waves, SYNTAX score and WMAs. CONCLUSIONS: Preprocedural TTE in combination with 2D-STE could help identify patients with UMI regardless of the presence or absence of ECG findings and WMAs.


Asunto(s)
Infarto del Miocardio , Intervención Coronaria Percutánea , Humanos , Volumen Sistólico , Medios de Contraste , Estudios Retrospectivos , Función Ventricular Izquierda , Gadolinio , Ecocardiografía/métodos , Infarto del Miocardio/diagnóstico por imagen , Infarto del Miocardio/cirugía
17.
Int J Mol Sci ; 25(18)2024 Sep 23.
Artículo en Inglés | MEDLINE | ID: mdl-39337682

RESUMEN

As atrial fibrillation (AF) progresses from initial paroxysmal episodes to the persistent phase, maintaining sinus rhythm for an extended period through pharmacotherapy and catheter ablation becomes difficult. A major cause of the deteriorated treatment outcome is the atrial structural and electrophysiological heterogeneity, which AF itself can exacerbate. This heterogeneity exists or manifests in various dimensions, including anatomically segmental structural features, the distribution of histological fibrosis and the autonomic nervous system, sarcolemmal ion channels, and electrophysiological properties. All these types of heterogeneity are closely related to the development of AF. Recognizing the heterogeneity provides a valuable approach to comprehending the underlying mechanisms in the complex excitatory patterns of AF and the determining factors that govern the seemingly chaotic propagation. Furthermore, substrate modification based on heterogeneity is a potential therapeutic strategy. This review aims to consolidate the current knowledge on structural and electrophysiological atrial heterogeneity and its relation to the pathogenesis of AF, drawing insights from clinical studies, animal and cell experiments, molecular basis, and computer-based approaches, to advance our understanding of the pathophysiology and management of AF.


Asunto(s)
Fibrilación Atrial , Atrios Cardíacos , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/patología , Humanos , Animales , Atrios Cardíacos/fisiopatología , Atrios Cardíacos/patología , Fenómenos Electrofisiológicos , Canales Iónicos/metabolismo
18.
J Cardiovasc Electrophysiol ; 34(9): 1869-1877, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37529869

RESUMEN

BACKGROUND: Since the local impedance (LI) of the ablation catheter reflects tissue characteristics, the efficacy of higher power (HP) compared to lower power (LP) in LI-guided ablation may differ from other index-guided ablations. OBJECTIVE: This study aimed to assess the efficacy of HP ablation in LI-guided ablation of atrial fibrillation (AF). METHODS: A prospective observational study was conducted, enrolling patients undergoing de novo ablation for AF. Pulmonary vein isolation was performed using point-by-point ablation with a RHYTHMIA HDxTM Mapping System and an open-irrigated ablation catheter with mini-electrodes (IntellaNav MIFI OI). Ablation was stopped when the LI drop reached 30 ohms, three seconds after the LI plateaued, or when ablation time reached 30 s. To balance the baseline differences, a unique method was used in which the power was changed between HP (45 W to anterior wall/40 W to posterior wall) and LP (35 W/30 W) alternately for each adjacent point. RESULTS: A total of 551 ablations in 10 patients were analyzed (HP, n = 276; LP, n = 275). The maximum LI drop was significantly larger (HP: 28.3 ± 5.4 vs. LP: 24.8 ± 6.3 ohm), and the time to minimum LI was significantly shorter (HP: 15.0 ± 6.3 vs. LP: 19.3 ± 6.6 s) in the HP setting. The unipolar electrogram analysis of three patients revealed that the electrogram indicating transmural lesion formation was observed more frequently in the HP setting. CONCLUSION: In LI-guided ablation, the HP could achieve a larger LI drop and shorter time to minimum LI, which may result in more transmural lesion formation compared to a LP setting.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Impedancia Eléctrica , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Venas Pulmonares/cirugía , Electrodos , Resultado del Tratamiento
19.
J Cardiovasc Electrophysiol ; 34(2): 478-482, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36579408

RESUMEN

INTRODUCTION: Persistent left superior vena cava (PLSVC) is accompanied by enlarged coronary sinus (CS) and deformation of the triangle of Koch. This makes anatomical evaluation of the atrioventricular (AV) nodal pathways difficult. METHODS: We attempted cryoablation of retrograde fast pathway located in the enlarged CS roof of PLSVC for slow-fast AV nodal reentrant tachycardia (AVNRT) induced by inadvertent antegrade fast pathway elimination during ablation of left atrial tachycardia. RESULTS: Slow-fast AVNRT was successfully eliminated without AV block progression. CONCLUSIONS: This is the first case of successful retrograde fast pathway ablation of the CS ostial roof for slow-fast AVNRT with PLSVC.


Asunto(s)
Ablación por Catéter , Seno Coronario , Criocirugía , Vena Cava Superior Izquierda Persistente , Taquicardia por Reentrada en el Nodo Atrioventricular , Humanos , Taquicardia por Reentrada en el Nodo Atrioventricular/diagnóstico , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía , Seno Coronario/diagnóstico por imagen , Seno Coronario/cirugía , Vena Cava Superior/diagnóstico por imagen , Vena Cava Superior/cirugía
20.
J Cardiovasc Electrophysiol ; 34(4): 888-897, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36852902

RESUMEN

BACKGROUND/OBJECTIVES: The QDOT-MICRO™ catheter allows very high-power and short-duration (vHPSD) ablation. This study aimed to investigate lesion characteristics using different ablation settings. METHODS: Radiofrequency applications (90 W/4 s, temperature-control mode with 55°C or 60°C target) were performed in excised porcine myocardium using three different approaches: single (SA), double nonrepetitive (DNRA), and double repetitive applications (DRA). Applications were performed with an interval of 1 min for DNRA, and without interval for DRA. RESULTS: A total of 480 lesions were analyzed. Lesion depth and volume were largest for DRA followed by DNRA and SA regardless of catheter direction (depth: 3.8 vs. 3.3 vs. 2.6 mm, p < .001 for all comparisons; volume: 176.6 vs. 145.1 vs. 97.0 mm3 , p < .001 for all comparisons). Surface area was significantly larger for DRA than for SA (45.1 vs. 38.3 mm2 , p < .001) and larger for DNRA than for SA (44.5 vs. 38.3 mm2 , p < .001), but was similar between DRA and DNRA (45.1 vs. 44.5 mm2 , p = .54). Steam-pops more frequently occurred for DRA than for SA (15.6% vs. 4.4%, p = .004) and DNRA (15.6% vs. 6.9%, p = .061), but the incidence was similar between SA and DNRA (4.4% vs. 6.9%, p = 1). Although surface area and lesion volume were larger in lesions with steam-pops than without steam-pops (46.5 vs. 38.1 mm2 , p = .018 and 128.3 vs. 96.8 mm3 , p = .068, respectively), lesions were not deeper (pop(+): 2.5 mm vs. pop(-): 2.6 mm, p = .75). CONCLUSIONS: DNRA produces larger lesions than SA without increasing the risk of steam-pops. DRA produces the largest lesions among the three groups, but with an increased risk of steam-pops. Even with steam-pops, lesions do not become deeper in vHPSD ablation.


Asunto(s)
Ablación por Catéter , Vapor , Porcinos , Animales , Ablación por Catéter/efectos adversos , Irrigación Terapéutica/efectos adversos , Diseño de Equipo , Catéteres
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA