Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Eur Radiol ; 34(2): 1388-1398, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37589906

RESUMEN

OBJECTIVES: Digital breast tomosynthesis (DBT) can improve diagnostic accuracy compared to 2D mammography, but DBT reporting is time-consuming and potentially more fatiguing. Changes in diagnostic accuracy and subjective and objective fatigue were evaluated over a DBT reporting session, and the impact of taking a reporting break was assessed. MATERIALS AND METHODS: Forty-five National Health Service (NHS) mammography readers from 6 hospitals read a cancer-enriched set of 40 DBT cases whilst eye tracked in this prospective cohort study, from December 2020 to April 2022. Eye-blink metrics were assessed as objective fatigue measures. Twenty-one readers had a reporting break, 24 did not. Subjective fatigue questionnaires were completed before and after the session. Diagnostic accuracy and subjective and objective fatigue measures were compared between the cohorts using parametric and non-parametric significance testing. RESULTS: Readers had on average 10 years post-training breast screening experience and took just under 2 h (105.8 min) to report all cases. Readers without a break reported greater levels of subjective fatigue (44% vs. 33%, p = 0.04), which related to greater objective fatigue: an increased average blink duration (296 ms vs. 286 ms, p < 0.001) and a reduced eye-opening velocity (76 mm/s vs. 82 mm/s, p < 0.001). Objective fatigue increased as the trial progressed for the no break cohort only (ps < 0.001). No difference was identified in diagnostic accuracy between the groups (accuracy: 87% vs. 87%, p = 0.92). CONCLUSIONS: Implementing a break during a 2-h DBT reporting session resulted in lower levels of subjective and objective fatigue. Breaks did not impact diagnostic accuracy, which may be related to the extensive experience of the readers. CLINICAL RELEVANCE STATEMENT: DBT is being incorporated into many mammography screening programmes. Recognising that reporting breaks are required when reading large volumes of DBT studies ensures this can be factored in when setting up reading sessions. TRIAL REGISTRATION: Clinical trials registration number: NCT03733106 KEY POINTS: • Use of digital breast tomosynthesis (DBT) in breast screening programmes can cause significant reader fatigue. • The effectiveness of incorporating reading breaks into DBT reporting sessions, to reduce mammography reader fatigue, was investigated using eye tracking. • Integrating breaks into DBT reporting sessions reduced reader fatigue; however, diagnostic accuracy was unaffected.


Asunto(s)
Neoplasias de la Mama , Lectura , Humanos , Femenino , Estudios Prospectivos , Medicina Estatal , Mamografía/métodos , Mama/diagnóstico por imagen , Detección Precoz del Cáncer/métodos , Neoplasias de la Mama/diagnóstico por imagen
2.
Rheumatology (Oxford) ; 53(6): 1142-9, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24509405

RESUMEN

OBJECTIVE: DIP joint OA is common but has few cost-effective, evidence-based interventions. Pain and deformity [radial or ulnar deviation of the joint or loss of full extension (extension lag)] frequently lead to functional and cosmetic issues. We investigated whether splinting the DIP joint would improve pain, function and deformity. METHODS: A prospective, radiologist-blinded, non-randomized, internally controlled trial of custom splinting of the DIP joint was carried out. Twenty-six subjects with painful, deforming DIP joint hand OA gave written, informed consent. One intervention joint and one control joint were nominated. A custom gutter splint was worn nightly for 3 months on the intervention joint, with clinical and radiological assessment at baseline, 3 and 6 months. Differences in the change were compared by the Wilcoxon signed rank test. RESULTS: The median average pain at baseline was similar in the intervention (6/10) and control joints (5/10). Average pain (primary outcome measure) and worst pain in the intervention joint were significantly lower at 3 months compared with baseline (P = 0.002, P = 0.02). Differences between intervention and control joint average pain reached significance at 6 months (P = 0.049). Extension lag deformity was significantly improved in intervention joints at 3 months and in splinted joints compared with matched contralateral joints (P = 0.016). CONCLUSION: Short-term night-time DIP joint splinting is a safe, simple treatment modality that reduces DIP joint pain and improves extension of the digit, and does not appear to give rise to non-compliance, increased stiffness or joint restriction. TRIAL REGISTRATION: clinical trials.gov, http://clinicaltrials.gov, NCT01249391.


Asunto(s)
Articulaciones de los Dedos/fisiopatología , Deformidades Adquiridas de la Mano/prevención & control , Inmovilización/métodos , Osteoartritis/terapia , Dolor/prevención & control , Anciano , Femenino , Deformidades Adquiridas de la Mano/etiología , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis/complicaciones , Osteoartritis/fisiopatología , Dolor/etiología , Dimensión del Dolor/métodos , Satisfacción del Paciente , Rango del Movimiento Articular , Índice de Severidad de la Enfermedad , Método Simple Ciego , Férulas (Fijadores) , Resultado del Tratamiento
3.
Acta Orthop ; 85(6): 577-84, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25267500

RESUMEN

BACKGROUND AND PURPOSE: Metal artifact reduction sequence (MARS) MRI is widely advocated for surveillance of metal-on-metal hip arthroplasties (MOM-HAs). However, its use is limited by susceptibility artifact at the prosthesis-bone interface, local availability, patient compliance, and cost (Hayter et al. 2011a). We wanted to determine whether CT is a suitable substitute for MARS MRI in evaluation of the painful MOM-HA. PATIENTS AND METHODS: 50 MOM-HA patients (30 female) with unexplained painful prostheses underwent MARS MRI and CT imaging. 2 observers who were blind regarding the clinical data objectively reported the following outcomes: soft tissue lesions (pseudotumors), muscle atrophy, and acetabular and femoral osteolysis. Diagnostic test characteristics were calculated. RESULTS: Pseudotumor was diagnosed in 25 of 50 hips by MARS MRI and in 11 of 50 by CT. Pseudotumors were classified as type 1 (n=2), type 2A (n=17), type 2B (n=4), and type 3 (n=2) by MARS MRI. CT did not permit pseudotumor classification. The sensitivity of CT for diagnosis of pseudotumor was 44% (95% CI: 25-65). CT had "slight" agreement with MARS MRI for quantification of muscle atrophy (κ=0.23, CI: 0.16-0.29; p<0.01). Osteolysis was identified in 15 of 50 patients by CT. 4 of these lesions were identified by MARS MRI. INTERPRETATION: CT was found to be superior to MRI for detection of osteolysis adjacent to MOM-HA, and should be incorporated into diagnostic algorithms. CT was unable to classify and failed to detect many pseudotumors, and it was unreliable for assessment of muscle atrophy. Where MARS MRI is contraindicated or unavailable, CT would be an unsuitable substitute and other modalities such as ultrasound should be considered.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/instrumentación , Prótesis de Cadera/efectos adversos , Prótesis Articulares de Metal sobre Metal/efectos adversos , Complicaciones Posoperatorias/diagnóstico por imagen , Complicaciones Posoperatorias/patología , Adulto , Algoritmos , Artralgia/diagnóstico por imagen , Artralgia/etiología , Artralgia/patología , Artefactos , Femenino , Estudios de Seguimiento , Granuloma de Células Plasmáticas/diagnóstico por imagen , Granuloma de Células Plasmáticas/etiología , Granuloma de Células Plasmáticas/patología , Humanos , Imagen por Resonancia Magnética/métodos , Imagen por Resonancia Magnética/estadística & datos numéricos , Masculino , Persona de Mediana Edad , Atrofia Muscular/diagnóstico por imagen , Atrofia Muscular/etiología , Atrofia Muscular/patología , Variaciones Dependientes del Observador , Osteólisis/diagnóstico por imagen , Osteólisis/etiología , Osteólisis/patología , Complicaciones Posoperatorias/etiología , Tomografía Computarizada por Rayos X/métodos , Tomografía Computarizada por Rayos X/estadística & datos numéricos
4.
Acta Orthop ; 85(4): 375-82, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24694273

RESUMEN

BACKGROUND AND PURPOSE: Metal artifact reduction sequence (MARS) MRI and ultrasound scanning (USS) can both be used to detect pseudotumors, abductor muscle atrophy, and tendinous pathology in patients with painful metal-on-metal (MOM) hip arthroplasty. We wanted to determine the diagnostic test characteristics of USS using MARS MRI as a reference for detection of pseudotumors and muscle atrophy. PatienTS AND METHODS: We performed a prospective cohort study to compare MARS MRI and USS findings in 19 consecutive patients with unilateral MOM hips. Protocolized USS was performed by consultant musculoskeletal radiologists who were blinded regarding clinical details. Reports were independently compared with MARS MRI, the imaging gold standard, to calculate predictive values. RESULTS: The prevalence of pseudotumors on MARS MRI was 68% (95% CI: 43-87) and on USS it was 53% (CI: 29-76). The sensitivity of USS in detecting pseudotumors was 69% (CI 39-91) and the specificity was 83% (CI: 36-97). The sensitivity of detection of abductor muscle atrophy was 47% (CI: 24-71). In addition, joint effusion was detected in 10 cases by USS and none were seen by MARS MRI. INTERPRETATION: We found a poor agreement between USS and MARS MRI. USS was inferior to MARS MRI for detection of pseudotumors and muscle atrophy, but it was superior for detection of joint effusion and tendinous pathologies. MARS MRI is more advantageous than USS for practical reasons, including preoperative planning and longitudinal comparison.


Asunto(s)
Artralgia/diagnóstico , Artroplastia de Reemplazo de Cadera/efectos adversos , Granuloma de Células Plasmáticas/diagnóstico , Imagen por Resonancia Magnética/normas , Atrofia Muscular/diagnóstico , Complicaciones Posoperatorias/diagnóstico , Ultrasonografía/normas , Anciano , Artralgia/etiología , Artefactos , Femenino , Necrosis de la Cabeza Femoral/cirugía , Granuloma de Células Plasmáticas/etiología , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Metales/efectos adversos , Persona de Mediana Edad , Atrofia Muscular/etiología , Osteoartritis de la Cadera/cirugía , Complicaciones Posoperatorias/etiología , Estudios Prospectivos , Reoperación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Ultrasonografía/métodos
5.
Eur J Radiol ; 177: 111535, 2024 May 29.
Artículo en Inglés | MEDLINE | ID: mdl-38852330

RESUMEN

PURPOSE: To analyse digital breast tomosynthesis (DBT) reading times in the screening setting, compared to 2D full-field digital mammography (FFDM), and investigate the impact of reader experience and professional group on interpretation times. METHOD: Reading time data were recorded in the PROSPECTS Trial, a prospective randomised trial comparing DBT plus FFDM or synthetic 2D mammography (S2D) to FFDM alone, in the National Health Service (NHS) breast screening programme, from January 2019-February 2023. Time to read DBT+FFDM or DBT+S2D and FFDM alone was calculated per case and reading times were compared between modalities using dependent T-tests. Reading times were compared between readers from different professional groups (radiologists and radiographer readers) and experience levels using independent T-tests. The learning curve effect of using DBT in screening on reading time was investigated using a Kruskal-Wallis test. RESULTS: Forty-eight readers interpreted 1,242 FFDM batches (34,210 FFDM cases) and 973 DBT batches (13,983 DBT cases). DBT reading time was doubled compared to FFDM (2.09 ± 0.64 min vs. 0.98 ± 0.30 min; p < 0.001), and DBT+S2D reading was longer than DBT + FFDM (2.24 ± 0.62 min vs. 2.04 ± 0.46 min; p = 0.006). No difference was identified in reading time between radiologists and radiographers (2.06 ± 0.71 min vs. 2.14 ± 0.46 min, respectively; p = 0.71). Readers with five or more years of experience reading DBT were quicker than those with less experience (1.86 ± 0.56 min vs. 2.37 ± 0.65 min; p = 0.008), and DBT reading time decreased after less than 9 months accrued screening experience (p = 0.01). CONCLUSIONS: DBT reading times were double those of FFDM in the screening setting, but there was a short learning curve effect with readers showing significant improvements in reading times within the first nine months of DBT experience. CLINICALTRIALS: gov Identifier: NCT03733106.

6.
AJR Am J Roentgenol ; 200(3): W314-20, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23436877

RESUMEN

OBJECTIVE: Recent reports indicate a lack of survival benefit for axillary lymph node dissection (ALND) versus sentinel lymph node biopsy in early breast cancer. To study this issue further, we assessed the accuracy and effectiveness of ultrasound examination in detecting axillary nodal involvement in breast cancer patients with the aim of refining our current clinical pathways. MATERIALS AND METHODS: Ultrasound data were collected from breast cancer cases over 3 years. Images were reviewed by experienced radiologists and the following characteristics were assessed: size, morphology, hyperechoic hilum, and cortical thickness of the ipsilateral axillary nodes. The findings were correlated with histologic outcomes after ALND. RESULTS: Two hundred twenty-four cases were included in the analysis, 113 (50.4%) of which had evidence of metastatic nodal involvement at final histology. Of these 113 cases, ultrasound findings for 59 (52.2%) were positive. The overall positive predictive value of ultrasound for detecting metastatic nodal involvement measured 0.81. The negative predictive value was 0.60. The sensitivity was 53.7%; specificity, 85.1%; and accuracy, 67.9%. The ultrasound morphologic lymph node features with the greatest correlation with malignancy were the absence of a hyperechoic hilum (p = 0.003) and increased cortical thickness (p = 0.03). Patients with a metastatic nodal burden density of at least 20% were more likely to have abnormal findings on axillary ultrasound examination (p = 0.009). CONCLUSION: Axillary ultrasound has a low negative predictive value and negative ultrasound results do not exclude axillary node metastases with sufficient sensitivity to justify its routine clinical use. Clinical pathways need to consider an evidence-based approach, focusing on the criteria by which we select breast cancer patients for ALND.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Carcinoma/diagnóstico por imagen , Carcinoma/secundario , Ganglios Linfáticos/diagnóstico por imagen , Ultrasonografía Mamaria/estadística & datos numéricos , Adulto , Anciano , Anciano de 80 o más Años , Axila , Neoplasias de la Mama/epidemiología , Carcinoma/epidemiología , Femenino , Humanos , Metástasis Linfática , Persona de Mediana Edad , Prevalencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Reino Unido/epidemiología , Adulto Joven
7.
Br J Radiol ; 96(1143): 20220629, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36633316

RESUMEN

OBJECTIVES: The interpretation of digital breast tomosynthesis (DBT) screening examinations is a complex task for an already overstretched workforce which has the potential to increase pressure on readers leading to fatigue and patient safety issues. Studies in non-medical and medical settings have suggested that changes in blink characteristics can reflect fatigue. The purpose of this study is to investigate the use of blink characteristics as an objective marker of fatigue in readers interpreting DBT breast screening examinations. METHODS: Twenty-six DBT readers involved in the UK PROSPECTS trial interpreted a test set of 40 DBT cases while being observed by an eye tracking device from November 2019 to February 2021. Raw data from the eye tracker were collected and automated processing software was used to produce eye blinking characteristics data which were analysed using multiple linear regression statistical models. RESULTS: Of the 26 DBT readers recruited, eye tracking data from 23 participants were analysed due to missing data rendering 3 participants' data uninterpretable. The mean reading time per DBT case was 2.81 min. There was a statistically significant increase in blinking duration of 0.38 ms/case as the reading session progressed (p < 0.0001). This was the result of a significant decrease in the number of ultra-short blinks lasting ≤50 ms (p = 0.0005) and a significant increase in longer blinks lasting 51-100 ms (p = 0.008). CONCLUSION: Changes in blinking characteristics could serve as objective measures of reader fatigue and may prove useful in the development of DBT reading protocols. ADVANCES IN KNOWLEDGE: Blink characteristics can be used as an objective measure of fatigue; however there is limited evidence of their use in radiological settings. Our study suggests that changes in blink duration and frequency could be used to monitor fatigue in DBT reading sessions.


Asunto(s)
Neoplasias de la Mama , Mamografía , Humanos , Femenino , Mamografía/métodos , Tamizaje Masivo/métodos , Modelos Lineales , Neoplasias de la Mama/diagnóstico por imagen , Estudios Retrospectivos , Mama/diagnóstico por imagen , Detección Precoz del Cáncer/métodos
8.
Lancet Rheumatol ; 3(9): e648-e658, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34476411

RESUMEN

BACKGROUND: Joint injury is a major risk factor for osteoarthritis and provides an opportunity to prospectively examine early processes associated with osteoarthritis. We investigated whether predefined baseline demographic and clinical factors, and protein analytes in knee synovial fluid and in plasma or serum, were associated with clinically relevant outcomes at 2 years after knee injury. METHODS: This longitudinal cohort study recruited individuals aged 16-50 years between Nov 1, 2010, and Nov 28, 2014, across six hospitals and clinics in London, UK. Participants were recruited within 8 weeks of having a clinically significant acute knee injury (effusion and structural injury on MRI), which was typically treated surgically. We measured several predefined clinical variables at baseline (eg, time from injury to sampling, extent and type of joint injury, synovial fluid blood staining, presence of effusion, self-reported sex, age, and BMI), and measured 12 synovial fluid and four plasma or serum biomarkers by immunoassay at baseline and 3 months. The primary outcome was Knee Injury and Osteoarthritis Outcome Score (KOOS4) at 2 years, adjusted for baseline score, assessed in all patients. Linear and logistic regression models adjusting for predefined covariates were used to assess associations between baseline variables and 2-year KOOS4. This study is registered with ClinicalTrials.gov, number NCT02667756. FINDINGS: We enrolled 150 patients at a median of 17 days (range 1-59, IQR 9-26) after knee injury. 123 (82%) were male, with a median age of 25 years (range 16-50, IQR 21-30). 98 (65%) of 150 participants completed a KOOS4 at 2 (or 3) years after enrolment (50 participants were lost to follow-up and two were withdrawn due to adverse events unrelated to study participation); 77 (51%) participants had all necessary variables available and were included in the core variable adjusted analysis. In the 2-year dataset mean KOOS4 improved from 38 (SD 18) at baseline to 79 (18) at 2 years. Baseline KOOS4, medium-to-large knee effusion, and moderate-to-severe synovial blood staining and their interaction significantly predicted 2-year KOOS4 (n=77; coefficient -20·5, 95% CI -34·8 to -6·18; p=0·0060). The only predefined biomarkers that showed independent associations with 2-year KOOS4 were synovial fluid MCP-1 (n=77; -0·015, 0·027 to -0·004 per change in 1 pg/mL units; p=0·011) and IL-6 (n=77; -0·0005, -0·0009 to -0·0001 per change in 1 pg/mL units; p=0·017). These biomarkers, combined with the interaction of effusion and blood staining, accounted for 39% of outcome variability. Two adverse events occurred that were linked to study participation, both at the time of blood sampling (one presyncopal episode, one tenderness and pain at the site of venepuncture). INTERPRETATION: The combination of effusion and haemarthrosis was significantly associated with symptomatic outcomes after acute knee injury. The synovial fluid molecular protein response to acute knee injury (best represented by MCP-1 and IL-6) was independently associated with symptomatic outcomes but not with structural outcomes, with the biomarkers overall playing a minor role relative to clinical predictors. The relationship between symptoms and structure after acute knee injury and their apparent dissociation early in this process need to be better understood to make clinical progress. FUNDING: Versus Arthritis, Kennedy Trust for Rheumatology Research, and NIHR Oxford Biomedical Research Centre.

10.
Br J Radiol ; 93(1116): 20201034, 2020 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-33112652

RESUMEN

The pandemic of COVID-19 presented an enormous challenge to the medical world in terms of diagnosis, treatment and health-care management as well as service organisation and provision. This novel virus and its spread affected every aspect of modern medical practice, ranging from investigating transmission of this new pathogen, antigen testing of symptomatic patients, imaging, assessing different treatment regimens and the production of a new vaccine. Imaging played a crucial role in the diagnosis of COVID-19-related lung disease, with plain radiography and CT being the main diagnostic modalities, with ultrasound a useful bedside imaging tool. The accurate and early diagnosis of the disease was not the only issue faced by Radiology Departments across the world; prevention of nosocomial infection, creating capacity with elective imaging suspension, management and protection of the workforce being few of the numerous challenges. The purpose of this manuscript is to present the steps that the Radiology Department of a large urban tertiary facility with a local vulnerable population, undertook to adapt the imaging service and structure, both initially escalating and then de-escalating a response to the COVID-19 pandemic. A step-by-step management strategy, effective and sustained staff deployment, imaging management are presented and discussed, to provide a guide for managing a major incident in a radiology department.


Asunto(s)
Infecciones por Coronavirus/diagnóstico por imagen , Diagnóstico por Imagen/métodos , Pulmón/diagnóstico por imagen , Neumonía Viral/diagnóstico por imagen , Servicio de Radiología en Hospital , Betacoronavirus , COVID-19 , Humanos , Londres , Pandemias , SARS-CoV-2 , Centros de Atención Terciaria
11.
Breast ; 51: 114-119, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32298962

RESUMEN

INTRODUCTION: This multicentre, retrospective study aimed to establish correlation between estimated tumour volume doubling times (TVDT) from a series of interval breast cancers with their clinicopathological features. The potential impact of delayed diagnosis on prognosis was also explored. MATERIALS AND METHODS: Interval cancers, where screening mammograms demonstrated changes that were retrospectively classified as either uncertain or suspicious, were reviewed from five screening units within the UK NHS Breast Screening Programme (NHSBSP). Data collected included the time interval between screening mammogram and cancer diagnosis, the size of the initial mammographic abnormality and of the subsequent cancer, demographics, mammographic density and tumour biology. We estimated volume doubling times and the estimated change in size and node status, which would have followed if these cancers had been detected at the previous screen. RESULTS: 306 interval cancers meeting the inclusion criteria were identified. Average time from screening to diagnosis was 644 days (SD 276 days). 19% were diagnosed in the first twelve months, 42% in the subsequent twelve months and 39% thereafter. Overall average estimated TVDT was 167 days (95% CI 151-186). Significant differences were noted with age (p = 0.01), grade (p < 0.001) and ER status (p < 0.001) with women under 60, grade 3 cancers and ER negative cancers having shorter TVDTs. HER2 positive tumours had shorter doubling times than HER2 negative, but this difference was not statistically significant. It was estimated that diagnosing these cancers at the previous screen would have increased ten-year survival from 82% to 86%. CONCLUSION: High grade, ER negativity and younger age were associated with shorter durations of TVDT. The role of HER2 status on interval cancer growth rate requires further assessment. It is likely that the delayed diagnosis of interval cancers confers a 4% reduction in ten-year survival.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/diagnóstico , Neoplasias de la Mama/patología , Carga Tumoral , Anciano , Anciano de 80 o más Años , Densidad de la Mama , Detección Precoz del Cáncer , Femenino , Humanos , Mamografía , Persona de Mediana Edad , Clasificación del Tumor , Estudios Retrospectivos , Medicina Estatal , Factores de Tiempo , Reino Unido/epidemiología
12.
Br J Radiol ; 91(1082): 20170626, 2018 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-29125333

RESUMEN

OBJECTIVE: To compare the experience of four UK Centres in the use of intradermal microbubbles and contrast enhanced ultrasound (CEUS) to pre-operatively identify and biopsy sentinel lymph nodes (SLN) in patients with breast cancer. METHODS: In all centres, breast cancer patients had a microbubble/CEUS SLN core biopsy prior to axillary surgery and patients in Centres 1 and 2 had a normal greyscale axillary ultrasound. Data were collected between 2010 and 2016; 1361 from Centre 1 (prospective, sequential), 376 from Centre 2 (retrospective, sequential), 121 from Centre 3 (retrospective, selected) and 48 from Centre 4 (prospective, selected). RESULTS: SLN were successfully core biopsied in 80% (Centre 1), 79.6% (Centre 2), 77.5% (Centre 3) and 88% (Centre 4). The sensitivities to identify all SLN metastases were 46.9% [95% confidence intervals (CI) (39.4-55.1)], 52.5% [95% CI (39.1-65.7)], 46.4% [95% CI (27.5-66.1)] and 45.5% [95% CI (16.7-76.6)], respectively. The specificities were 99.7% [95% CI (I98.9-100)], 98.1% [95% CI (94.5-99.6)], 100% [95% CI (93.2-100%)] and 96.3% [95% CI (81-99.9)], respectively.The negative predictive values were 87.0% [95% CI (84.3-89.3)], 84.5% [95% CI (78.4-89.5)], 86.9% [95% CI (82.4-90.3)] and 86.2% [95% CI (78.4-91.5)], respectively. At Centres 1 and 2, 12/730 (1.6%) and 7/181 (4%), respectively, of patients with a benign microbubble/CEUS SLN core biopsy had two or more lymph node (LN) macrometastases found at the end of primary surgical treatment. CONCLUSION: The identification and biopsy of SLN using CEUS is a reproducible technique. Advances in knowledge: In the era of axillary conservation, microbubble/CEUS SLN core biopsy has the potential to succeed surgical staging of the axilla.


Asunto(s)
Axila/patología , Neoplasias de la Mama/patología , Metástasis Linfática/diagnóstico por imagen , Microburbujas , Biopsia del Ganglio Linfático Centinela/métodos , Ultrasonografía Mamaria , Adulto , Anciano , Anciano de 80 o más Años , Axila/diagnóstico por imagen , Neoplasias de la Mama/diagnóstico por imagen , Medios de Contraste , Femenino , Humanos , Persona de Mediana Edad , Cuidados Preoperatorios , Estudios Prospectivos , Estudios Retrospectivos , Sensibilidad y Especificidad , Ganglio Linfático Centinela
13.
Curr Probl Diagn Radiol ; 35(2): 55-64, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-16517289

RESUMEN

The following learning objectives will be covered in this article: (1) To briefly review the range of surgical options for patellofemoral joint disorders; and (2) to recognize the expected appearances and complications of the postoperative patellofemoral joint on conventional radiography and cross sectional imaging.


Asunto(s)
Cartílago Articular/diagnóstico por imagen , Fracturas Óseas/cirugía , Articulación de la Rodilla/diagnóstico por imagen , Rótula/cirugía , Adulto , Enfermedades de los Cartílagos/cirugía , Cartílago Articular/trasplante , Femenino , Fémur/cirugía , Humanos , Articulación de la Rodilla/cirugía , Masculino , Persona de Mediana Edad , Osteoartritis de la Rodilla/cirugía , Rótula/anomalías , Rótula/lesiones , Periodo Posoperatorio , Prótesis e Implantes , Radiografía
14.
J Orthop Res ; 34(6): 1077-83, 2016 06.
Artículo en Inglés | MEDLINE | ID: mdl-26630078

RESUMEN

Failure to place an artificial hip in the optimal center of rotation results in poor hip function and costly complications. The aim of this study was to develop robust methodology to estimate hip center of rotation (hCoR) from preoperative computed tomography (CT) scans, using contralateral anatomy, in patients with unilateral diseased hips. Ten patients (five male, five female) with normal pelvic anatomy, and one patient with a unilateral dysplastic acetabulum were recruited from the London Implant Retrieval center image bank. 3D models of each pelvis were generated using commercial software. Two methods for estimation of hCoR were compared. Method 1 used a mirroring technique alone. Method 2 utilized mirroring and automatic alignment. Predicted versus actual hCoR co-ordinates were compared using intraclass correlation coefficients and paired T-tests. Both methods predicted hCoR with excellent agreement to original co-ordinates (>0.9) in all axes. Both techniques allowed prediction of the hCoR within ± 5 mm in all axes. Both techniques provided useful clinical information for planning acetabular reconstruction in patients with unilateral defects. Method 1 was less complex and is suitable for patients with developmental and degenerative pathologies. Method 2 may provide greater accuracy in a discrete group of patients with normal development prior to pathology (e.g., acetabular fractures). © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:1077-1083, 2016.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Articulación de la Cadera/diagnóstico por imagen , Imagenología Tridimensional , Tomografía Computarizada por Rayos X , Femenino , Humanos , Masculino
15.
Arthritis ; 2015: 852989, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25785197

RESUMEN

Objectives. Early change in rheumatoid arthritis (RA) is characterised by periarticular osteopenia. We investigated the relationship of early metacarpal digital X-ray radiogrammetry bone mineral density (DXR-BMD) change rate (RC-BMD, mg/cm(2)/month) to longitudinal changes in hand and feet radiographic and wrist MRI scores over 1 year. Materials and Methods. 10 RA patients completed the study and had wrist 3T-MRI and hand and feet X-rays at various time points over 1 year. MRI was scored by RAMRIS, X-ray was done by van der Heijde modified Sharp scoring, and RC-BMD was analysed using dxr-online. Results. There was good correlation amongst the two scorers for MRI measures and ICC for erosions: 0.984, BME: 0.943, and synovitis: 0.657. Strong relationships were observed between RC-BMD at 12-week and 1-year change in wrist marrow oedema (BME) (r = 0.78, P = 0.035) but not with erosion, synovitis, or radiographic scores. Conclusion. Early RC-BMD correlates with 1-year wrist BME change, which is a known predictor of future erosion and joint damage. However, in our pilot study, early RC-BMD did not show relationships to MRI erosion or radiographic changes over 1 year. This may reflect a slower kinetic in the appearance of MRI/radiographic erosions, generating the hypothesis that RC-BMD may be a more sensitive and early structural prognostic marker in RA follow-up.

16.
Eur J Radiol ; 82(8): 1286-91, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23562303

RESUMEN

RATIONAL AND OBJECTIVE: Dynamic contrast enhanced (DCE)-MRI has great potential to provide quantitative measure of inflammatory activity in rheumatoid arthritis. There is no current benchmark to establish the stability of signal in the joints of healthy subjects when imaged with DCE-MRI longitudinally, which is crucial so as to differentiate changes induced by treatment from the inherent variability of perfusion measures. The objective of this study was to test a pixel-by-pixel parametric map based approach for analysis of DCE-MRI (Dynamika) and to investigate the variability in signal characteristics over time in healthy controls using longitudinally acquired images. MATERIALS AND METHODS: 10 healthy volunteers enrolled, dominant wrists were imaged with contrast enhanced 3T MRI at baseline, week 12, 24 and 52 and scored with RAMRIS, DCE-MRI was analysed using a novel quantification parametric map based approach. Radiographs were obtained at baseline and week 52 and scored using modified Sharp van der Heidje method. RAMRIS scores and dynamic MRI measures were correlated. RESULTS: No erosions were seen on radiographs, whereas MRI showed erosion-like changes, low grade bone marrow oedema and low-moderate synovial enhancement. The DCE-MRI parameters were stable (baseline scores, variability) (mean±st.dev); in whole wrist analysis, MEmean (1.3±0.07, -0.08±0.1 at week 24) and IREmean (0.008±0.004, -0.002±0.005 at week 12 and 24). In the rough wrist ROI, MEmean (1.2±0.07, 0.04±0.02 at week 52) and IREmean (0.001±0.0008, 0.0006±0.0009 at week 52) and precise wrist ROI, MEmean (1.2±0.09, 0.04±0.04 at week 52) and IREmean (0.001±0.0008, 0.0008±0.001 at week 24 and 52). The Dynamic parameters obtained using fully automated analysis demonstrated strong, statistically significant correlations with RAMRIS synovitis scores. CONCLUSION: The study demonstrated that contrast enhancement does occur in healthy volunteers but the inherent variability of perfusion measures obtained with quantitative DCE-MRI method is low and stable, suggesting its suitability for longitudinal studies of inflammatory arthritis. These results also provide important information regarding potential cut-off levels for imaging remission goals in patients with RA using both RAMRIS and DCE-MRI extracted parametric parameters.


Asunto(s)
Algoritmos , Gadolinio DTPA , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Reconocimiento de Normas Patrones Automatizadas/métodos , Articulación de la Muñeca/anatomía & histología , Adulto , Medios de Contraste , Femenino , Voluntarios Sanos , Humanos , Aumento de la Imagen/métodos , Estudios Longitudinales , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Adulto Joven
17.
J Bone Joint Surg Am ; 94(4): 317-25, 2012 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-22336970

RESUMEN

INTRODUCTION: Many papers have been published recently on the subject of pseudotumors surrounding metal-on-metal hip resurfacing and replacement prostheses. These pseudotumors are sterile, inflammatory lesions within the periprosthetic tissues and have been variously termed masses, cysts, bursae, collections, or aseptic lymphocyte-dominated vasculitis-associated lesions (ALVAL). The prevalence of pseudotumors in patients with a well-functioning metal-on-metal hip prosthesis is not well known. The purpose of this study was to quantify the prevalence of pseudotumors adjacent to well-functioning and painful metal-on-metal hip prostheses, to characterize these lesions with use of magnetic resonance imaging, and to assess the relationship between their presence and acetabular cup position with use of three-dimensional computed tomography. METHODS: We performed a case-control study to compare the magnetic resonance imaging findings of patients with a well-functioning unilateral metal-on-metal hip prosthesis and patients with a painful prosthesis (defined by either revision arthroplasty performed because of unexplained pain or an Oxford hip score of <30 of 48 possible points). Thirty patients with a painful hip prosthesis and twenty-eight controls with a well-functioning prosthesis were recruited consecutively. All patients also underwent computed tomography to assess the position of the acetabular component. RESULTS: Thirty-four patients were diagnosed with a pseudotumor. However, the prevalence of pseudotumors in patients with a painful hip (seventeen of thirty, 57%) was not significantly different from the prevalence in the control group (seventeen of twenty-eight, 61%). No objective differences in pseudotumor characteristics between the groups were identified. No clear association between the presence of a pseudotumor and acetabular component position was identified. The Oxford hip score in the group with a painful hip (mean, 20.2; 95% confidence interval [CI], 12.7 to 45.8) was poorer than that in the control group (mean, 41.2; 95% CI, 18.5 to 45.8; p ≤ 0.0001). CONCLUSIONS: A periprosthetic cystic pseudotumor was diagnosed commonly (in thirty-four [59%] of the entire study cohort) with use of metal artifact reduction sequence (MARS) magnetic resonance imaging in this series of patients with a metal-on-metal hip prosthesis. The prevalence of pseudotumors was similar in patients with a well-functioning hip prosthesis and patients with a painful hip. Pseudotumors were also diagnosed commonly in patients with a well-positioned acetabular component. Although magnetic resonance imaging is useful for surgical planning, the presence of a cystic pseudotumor may not necessarily indicate the need for revision arthroplasty. Further correlation of clinical and imaging data is needed to determine the natural history of pseudotumors to guide clinical practice.


Asunto(s)
Quistes/diagnóstico , Quistes/etiología , Prótesis de Cadera/efectos adversos , Imagenología Tridimensional , Imagen por Resonancia Magnética , Tomografía Computarizada por Rayos X , Adulto , Estudios de Casos y Controles , Quistes/epidemiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Prevalencia , Estudios Prospectivos , Diseño de Prótesis
18.
J Ultrasound Med ; 24(7): 905-9, 2005 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-15972704

RESUMEN

OBJECTIVE: The purpose of this study was to determine the normal range of Doppler ultrasonographic measurements of spermatic cord arteries in a cohort of healthy men. METHODS: The spermatic cord arteries of 51 men were interrogated with color Doppler ultrasonography. The resistive index (RI) of each artery was measured for the entire cohort; peak systolic and end-diastolic velocity values were obtained in a smaller subgroup (n = 31). The artery with the lowest RI was labeled A; the other 2 arteries were identified as B and C. RESULTS: Three separate arteries were identified within the spermatic cord in all individuals. The median RI values for arteries A, B, and C were 0.70 (range, 0.48-0.82), 0.84 (0.67-0.90), and 0.84 (0.72-0.92), respectively. One-way analysis of variance showed a significant difference between the mean RIs of arteries A and B (P < .0001) and arteries A and artery C (P < .0001) but not between B and C (P = .49). Peak systolic and end-diastolic velocity values differed significantly between arteries A and B (P < .0001) and arteries A and C (P < .0001) but not between B and C (P = .31). No age effect was shown for the RI measurements of the cohort. CONCLUSIONS: Color Doppler ultrasonography enables the objective quantification of Doppler measurements of arteries within the spermatic cord. Knowledge of the normal range of Doppler measurements for spermatic cord arteries that supply the testes may be a useful adjunct to the assessment of the testes.


Asunto(s)
Cordón Espermático/irrigación sanguínea , Cordón Espermático/diagnóstico por imagen , Ultrasonografía Doppler en Color/métodos , Resistencia Vascular/fisiología , Adolescente , Adulto , Estudios de Cohortes , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Valores de Referencia
19.
Breast J ; 11(6): 398-402, 2005.
Artículo en Inglés | MEDLINE | ID: mdl-16297083

RESUMEN

A prospective audit of 221 breast biopsies was carried out to assess the pain/discomfort experienced during image-guided breast biopsies. The only significant factor in pain scores was the size of the needle used. Fine-needle aspiration cytology using a 21-gauge needle was found to cause the most discomfort.


Asunto(s)
Biopsia con Aguja Fina/efectos adversos , Neoplasias de la Mama/patología , Dolor/etiología , Femenino , Humanos , Auditoría Médica , Satisfacción del Paciente , Estudios Prospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA