1.
Circulation ; 150(15): 1174-1186, 2024 Oct 08.
Artículo en Inglés | MEDLINE | ID: mdl-39258362

RESUMEN

BACKGROUND: Evidence from clinical trials of early pulsed field ablation (PFA) systems in treating atrial fibrillation has demonstrated their promising potential to reduce complications associated with conventional thermal modalities while maintaining efficacy. However, the lack of a fully integrated mapping system, a staple technology of most modern electrophysiology procedures, poses limitations in lesion creation and workflow options. A novel variable-loop PFA catheter integrated with an electroanatomic mapping system has been developed that allows for real-time nonfluoroscopic procedural guidance and lesion indexing as well as feedback of tissue-to-catheter proximity. AdmIRE (Assessment of Safety and Effectiveness in Treatment Management of Atrial Fibrillation With the Bosense-Webster Irreversible Electroporation Ablation System), a multicenter, single-arm, Food and Drug Administration investigational device exemption study, evaluated the long-term safety and effectiveness of this integrated PFA system in a large United States-based drug-refractory symptomatic paroxysmal atrial fibrillation patient population. METHODS: Using the PFA catheter with a compatible electroanatomic mapping system, patients with drug-refractory symptomatic paroxysmal atrial fibrillation underwent pulmonary vein isolation. The primary safety end point was primary adverse event within 7 days of ablation. The primary effectiveness end point was a composite end point that included 12-month freedom from documented atrial tachyarrhythmia (ie, atrial fibrillation, atrial tachycardia, atrial flutter) episodes, failure to achieve pulmonary vein isolation, use of a nonstudy catheter for pulmonary vein isolation, repeat procedure (except for one redo during blanking), taking a new or previously failed class I or III antiarrhythmic drug at higher dose after blanking, or direct current cardioversion after blanking. RESULTS: At 30 centers, 277 patients with paroxysmal atrial fibrillation (61.5±10.3 years of age; 64.3% male) in the pivotal cohort underwent PFA. More than 25% of the procedures were performed without fluoroscopy. Median (Q1, Q3) pulmonary vein isolation procedure, fluoroscopy, and transpired PFA application times were 81.0 (61.0, 112.0), 7.1 (0.00, 14.3), and 31.0 (24.8, 40.9) minutes, respectively. The primary adverse event rate was 2.9% (8 of 272), with the most common complication being pericardial tamponade. The 12-month primary effectiveness end point was 74.6%. The 1-year freedom from atrial fibrillation, atrial tachycardia, or atrial flutter recurrence rate after blanking was 75.4%. Substantial improvements in quality of life were observed as early as 3 months after the procedure, concurrent with a reduction in multiple health care use measures. CONCLUSIONS: AdmIRE confirmed the safety and effectiveness of the variable-loop PFA catheter, with short procedure and PFA application times and low fluoroscopy exposure. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT05293639.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Fibrilación Atrial/cirugía , Fibrilación Atrial/terapia , Humanos , Masculino , Femenino , Persona de Mediana Edad , Ablación por Catéter/métodos , Ablación por Catéter/efectos adversos , Ablación por Catéter/instrumentación , Anciano , Resultado del Tratamiento , Venas Pulmonares/cirugía
2.
Artículo en Inglés | MEDLINE | ID: mdl-39363431

RESUMEN

INTRODUCTION: Pulsed field ablation (PFA) has emerged as an innovative therapy for cardiac arrhythmias. Drawing parallels with PFA's application in solid tumors, calcium chloride (CaCl2) as an adjuvant therapy, known as calcium electroporation, may amplify PFA's apoptotic effects. We propose that PFA in the atrium could enhance calcium uptake through PFA-created pores, thereby increasing ablation efficacy even at reduced power levels by exploiting PFA's permeabilization effects. METHODS: We conducted in vivo ablations on the atria of seven pigs using low PFA power (250 V, 20 µs for 50 pulses at 200 ms intervals). Post-PFA, we randomly administered an infusion of either 200 mg/2 ml CaCl2 (calcium group) or saline (control) directly to the ablation site via the catheter tip. We evaluated reduction in electrogram voltage amplitude, electrocardiography (ECG) parameters, ablation lesion parameters, and histology after PFA. RESULTS: Nineteen lesions from control and calcium groups were examined. Control lesions showed no voltage decrease post-PFA, whereas calcium-treated lesions exhibited a significant voltage reduction. Gross pathology indicated marked differences in maximum lesion surface diameter, depth, and volume between the lesion groups. Histologically, calcium group lesions were characterized by a more severe acute PFA response with contraction band necrosis, myocytolysis and nuclear pyknosis in adjacent myocardium, in addition to microhemorrhages. CONCLUSION: Infusing calcium chloride locally after PFA markedly improves the immediate efficacy of electroporation in porcine atria. This study suggests that calcium electroporation could bolster PFA outcomes without higher energy levels, potentially diminishing associated risks. These preliminary findings warrant further research into the long-term efficacy and potential clinical application of calcium electroporation in PFA.

3.
J Cardiovasc Electrophysiol ; 35(1): 44-57, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37927196

RESUMEN

BACKGROUND: Intracardiac echocardiography (ICE) is increasingly used during left atrial appendage occlusion (LAAO) as an alternative to transesophageal echocardiography (TEE). The objective of this study is to evaluate the impact of ICE versus TEE guidance during LAAO on procedural characteristics and acute outcomes, as well the presence of peri-device leaks and residual septal defects during follow-up. METHODS: All studies comparing ICE-guided versus TEE-guided LAAO were identified. The primary outcomes were procedural efficacy and occurrence of procedure-related complications. Secondary outcomes included lab efficiency (defined as a reduction in in-room time), procedural time, fluoroscopy time, and presence of peri-device leaks and residual interatrial septal defects (IASD) during follow-up. RESULTS: Twelve studies (n = 5637) were included. There were no differences in procedural success (98.3% vs. 97.8%; OR 0.73, 95% CI 0.42-1.27, p = .27; I2 = 0%) or adverse events (4.5% vs. 4.4%; OR 0.81 95% CI 0.56-1.16, p = .25; I2 = 0%) between the ICE-guided and TEE-guided groups. ICE guidance reduced in in-room time (mean-weighted 28.6-min reduction in in-room time) without differences in procedural time or fluoroscopy time. There were no differences in peri-device leak (OR 0.93, 95% CI 0.68-1.27, p = 0.64); however, an increased prevalence of residual IASD was observed with ICE-guided versus TEE-guided LAAO (46.3% vs. 34.2%; OR 2.23, 95% CI 1.05-4.75, p = 0.04). CONCLUSION: ICE guidance is associated with similar procedural efficacy and safety, but could result in improved lab efficiency (as established by a significant reduction in in-room time). No differences in the rate of periprocedural leaks were found. A higher prevalence of residual interatrial septal defects was observed with ICE guidance.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Humanos , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Fibrilación Atrial/complicaciones , Ecocardiografía Transesofágica , Resultado del Tratamiento
4.
Artículo en Inglés | MEDLINE | ID: mdl-38994680

RESUMEN

INTRODUCTION: Scar substrate in nonischemic cardiomyopathy (NICM) patients is often difficult to identify. Advances in cardiac imaging, especially using late iodine-enhanced computed tomography (LIE-CT), allow better characterization of scars giving rise to ventricular tachycardia (VT). Currently, there are limited data on clinical correlates of CT-derived scar substrates in NICM. We sought assess the relationship between scar location on LIE-CT and outcomes after radiofrequency catheter ablation (RFCA) in NICM patients with VT. METHODS: From 2020 to 2022, consecutive patients with NICM undergoing VT RFCA with integration of cardiac CT scar modeling (inHeart, Pessac, France) were included at two US tertiary care centers. The CT protocol included both arterial-enhanced imaging for anatomical modeling and LIE-CT for scar assessment. The distribution of substrate on CT was analyzed in relation to patient outcomes, with primary endpoints being VT recurrence and the need for repeat ablation procedure. RESULTS: Sixty patients were included (age 64 ± 12 years, 90% men). Over a median follow-up of 120 days (interquartile range [IQR]: 41-365), repeat ablation procedures were required in 32 (53%). VT recurrence occurred in 46 (77%), with a median time to recurrence of 40 days (IQR: 8-65). CT-derived total scar volume positively correlated with intrinsic QRS duration (r = .34, p = 0.008). Septal scar was found on CT in 34 (57%), and lateral scar in 40 (7%). On univariate logistic regression, septal scar was associated with increased odds of repeat ablation (odds ratio [OR]: 2.9 [1.0-8.4]; p = 0.046), while lateral scar was not (OR: 0.9 [0.3-2.7]; p = 0.855). Septal scar better predicted VT recurrence when compared to lateral scar, but neither were statistically significant (septal scar OR: 3.0 [0.9-10.7]; p = 0.078; lateral scar OR: 1.7 [0.5-5.9]; p = 0.391). CONCLUSION: In this tertiary care referral population, patients with NICM undergoing VT catheter ablation with septal LIE-CT have nearly threefold increased risk of need for repeat ablation.

5.
J Cardiovasc Electrophysiol ; 35(8): 1645-1655, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38924224

RESUMEN

INTRODUCTION: Training in clinical cardiac electrophysiology (CCEP) involves the development of catheter handling skills to safely deliver effective treatment. Objective data from analysis of ablation data for evaluating trainee of CCEP procedures has not previously been possible. Using the artificial intelligence cloud-based system (CARTONET), we assessed the impact of trainee progress through ablation procedural quality. METHODS: Lesion- and procedure-level data from all de novo atrial fibrillation (AF) and cavotricuspid isthmus (CTI) ablations involving first-year (Y1) or second-year (Y2) fellows across a full year of fellowship was curated within Cartonet. Lesions were automatically assigned to anatomic locations. RESULTS: Lesion characteristics, including contact force, catheter stability, impedance drop, ablation index value, and interlesion time/distance were similar over each training year. Anatomic location and supervising operator significantly affected catheter stability. The proportion of lesion sets delivered independently and of lesions delivered by the trainee increased steadily from the first quartile of Y1 to the last quartile of Y2. Trainee perception of difficult regions did not correspond to objective measures. CONCLUSION: Objective ablation data from Cartonet showed that the progression of trainees through CCEP training does not impact lesion-level measures of treatment efficacy (i.e., catheter stability, impedance drop). Data demonstrates increasing independence over a training fellowship. Analyses like these could be useful to inform individualized training programs and to track trainee's progress. It may also be a useful quality assurance tool for ensuring ongoing consistency of treatment delivered within training institutions.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Competencia Clínica , Educación de Postgrado en Medicina , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Curva de Aprendizaje , Técnicas Electrofisiológicas Cardíacas , Inteligencia Artificial , Factores de Tiempo , Resultado del Tratamiento , Becas , Cardiólogos/educación , Electrofisiología Cardíaca/educación , Catéteres Cardíacos
6.
J Cardiovasc Electrophysiol ; 35(10): 1962-1971, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39113311

RESUMEN

INTRODUCTION: High-frequency low-tidal-volume (HFLTV) ventilation during radiofrequency catheter ablation (RFCA) for paroxysmal atrial fibrillation (PAF) has been shown to be superior to standard ventilation (SV) in terms of procedural efficiency, acute and long-term clinical outcomes. Our study aimed to compare ablation lesions characteristics utilizing HFLTV ventilation versus SV during RFCA of PAF. METHODS: A retrospective analysis was conducted on patients who underwent pulmonary vein isolation (PVI) for PAF between August 2022 and March 2023, using high-power short-duration ablation. Thirty-five patients underwent RFCA with HFLTV ventilation and were matched with another cohort of 35 patients who underwent RFCA with SV. Parameters including ablation duration, contact force (CF), impedance drop, and ablation index were extracted from the CARTONET database for each ablation lesion. RESULTS: A total of 70 patients were included (HFLTV = 35/2484 lesions, SV = 35/2830 lesions) in the analysis. There were no differences in baseline characteristics between the groups. While targeting the same ablation index, the HFLTV ventilation group demonstrated shorter average ablation duration per lesion (12.3 ± 5.0 vs. 15.4 ± 8.4 s, p < .001), higher average CF (17.0 ± 8.5 vs. 10.5 ± 4.6 g, p < .001), and greater impedance reduction (9.5 ± 4.6 vs. 7.7 ± 4.1 ohms, p < .001). HFLTV ventilation group also demonstrated shorter total procedural time (61.3 ± 25.5 vs. 90.8 ± 22.8 min, p < .001), ablation time (40.5 ± 18.6 vs. 65.8 ± 22.5 min, p < .001), and RF time (15.3 ± 4.8 vs. 22.9 ± 9.7 min, p < .001). CONCLUSION: HFLTV ventilation during PVI for PAF was associated with improved ablation lesion parameters and procedural efficiency compared to SV.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Frecuencia Cardíaca , Venas Pulmonares , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Femenino , Masculino , Ablación por Catéter/efectos adversos , Estudios Retrospectivos , Persona de Mediana Edad , Resultado del Tratamiento , Anciano , Venas Pulmonares/cirugía , Venas Pulmonares/fisiopatología , Factores de Tiempo , Potenciales de Acción , Bases de Datos Factuales
7.
Rev Cardiovasc Med ; 25(1): 19, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-39077641

RESUMEN

Cardiac implantable electronic device (CIED) infections represent one of the most threatening complications associated with device implantation, due to an increase in morbidity and mortality rates, as well as healthcare costs. Besides, it is important to highlight that when compared to the initial implantation of a device, the risks associated with procedures like generator changes, lead and pocket revisions, or device upgrades double. Consequently, to address this issue, various scoring systems, like the PADIT (Prior Procedures, Age, Depressed Renal Function, Immunocompromised Status, Type of Procedure), the RI-AIAC (Ricerca Sulle Infezioni Associate a ImpiAnto o Sostituzione di CIED), and the Shariff score, along with predictive models, have been developed to identify patients at a greater risk of infection. Moreover, several interventions have been assessed to evaluate their role in infection prevention ranging from improving skin preparation and surgical techniques to considering alternative strategies such as the subcutaneous Implantable Cardioverter-Defibrillator (ICD). Methods like antimicrobial prophylaxis, pocket irrigation, chlorhexidine gluconate pocket lavage, capsulectomy, and the use of antibacterial envelopes have been also explored as preventive measures. In this review, we provide a comprehensive assessment of CIED infections in patients undergoing repeat procedures and the strategies designed to reduce the risk of these infections.

8.
Br J Anaesth ; 132(4): 779-788, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38087741

RESUMEN

BACKGROUND: We investigated the effects of ketamine on desaturation and the risk of nursing home discharge in patients undergoing procedural sedation by anaesthetists. METHODS: We included adult patients who underwent procedures under monitored anaesthetic care between 2005 and 2021 at two academic healthcare networks in the USA. The primary outcome was intraprocedural oxygen desaturation, defined as oxygen saturation <90% for ≥2 consecutive minutes. The co-primary outcome was a nursing home discharge. RESULTS: Among 234,170 included patients undergoing procedural sedation, intraprocedural desaturation occurred in 5.6% of patients who received ketamine vs 5.2% of patients who did not receive ketamine (adjusted odds ratio [ORadj] 1.22, 95% confidence interval [CI] 1.15-1.29, P<0.001; adjusted absolute risk difference [ARDadj] 1%, 95% CI 0.7-1.3%, P<0.001). The effect was magnified by age >65 yr, smoking, or preprocedural ICU admission (P-for-interaction <0.001, ORadj 1.35, 95% CI 1.25-1.45, P<0.001; ARDadj 2%, 95% CI 1.56-2.49%, P<0.001), procedural risk factors (upper endoscopy of longer than 2 h; P-for-interaction <0.001, ORadj 2.91, 95% CI 1.85-4.58, P<0.001; ARDadj 16.2%, 95% CI 9.8-22.5%, P<0.001), and high ketamine dose (P-for-trend <0.001, ORadj 1.61, 95% CI, 1.43-1.81 for ketamine >0.5 mg kg-1). Concomitant opioid administration mitigated the risk (P-for-interaction <0.001). Ketamine was associated with higher odds of nursing home discharge (ORadj 1.11, 95% CI 1.02-1.21, P=0.012; ARDadj 0.25%, 95% CI 0.05-0.46%, P=0.014). CONCLUSIONS: Ketamine use for procedural sedation was associated with an increased risk of oxygen desaturation and discharge to a nursing home. The effect was dose-dependent and magnified in subgroups of vulnerable patients.


Asunto(s)
Ketamina , Adulto , Humanos , Ketamina/efectos adversos , Estudios Retrospectivos , Hospitales , Sistema de Registros , Servicio de Urgencia en Hospital , Oxígeno , Atención a la Salud , Aceptación de la Atención de Salud , Sedación Consciente/métodos , Hipnóticos y Sedantes
9.
Am Heart J ; 261: 95-103, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37019195

RESUMEN

BACKGROUND: Atrial fibrillation (AF) is the most common arrhythmia encountered in clinical practice and is associated with significant morbidity, mortality, and financial burden. Obstructive sleep apnea (OSA) is more common in individuals with AF and may impair the efficacy of rhythm control strategies including catheter ablation. However, the prevalence of undiagnosed OSA in all-comers with AF is unknown. DESIGN: This pragmatic, phase IV prospective cohort study will test 250-300 consecutive ambulatory AF patients with all patterns of atrial fibrillation (paroxysmal, persistent, and long-term persistent) and no prior sleep testing for OSA using the WatchPAT system, a disposable home sleep test (HST). The primary outcome of the study is the prevalence of undiagnosed OSA in all-comers with atrial fibrillation. RESULTS: Preliminary results from the initial pilot enrollment of approximately 15% (N = 38) of the planned sample size demonstrate a 79.0% prevalence of at least mild (AHI≥5) OSA or greater in consecutively enrolled patient with all patterns of AF. CONCLUSIONS: We report the design, methodology, and preliminary results of our study to define the prevalence of OSA in AF patients. This study will help inform approaches to OSA screening in patients with AF for which there is currently little practical guidance. CLINICAL TRIAL REGISTRATION: NCT05155813.


Asunto(s)
Fibrilación Atrial , Apnea Obstructiva del Sueño , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/complicaciones , Estudios Prospectivos , Factores de Riesgo , Sueño , Apnea Obstructiva del Sueño/diagnóstico , Apnea Obstructiva del Sueño/epidemiología , Apnea Obstructiva del Sueño/complicaciones
10.
J Cardiovasc Electrophysiol ; 34(4): 918-927, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36852908

RESUMEN

INTRODUCTION: The association between ambient circulating environments (CEs) and ablation lesions has been largely underexplored. METHODS: Viable bovine myocardium was placed in a saline bath in an ex vivo endocardial model. Radiofrequency (RF) ablation was performed using three different ablation catheters: 3.5 mm open irrigated (OI), 4, and 8 mm. Variable flow rates of surrounding bath fluids were applied to simulate standard flow, high flow, and no flow. For in vivo epicardial ablation, 24 rats underwent a single OI ablation and performed with circulating saline (30 ml/min; n = 12), versus those immersed in saline without circulation (n = 12). RESULTS: High flow reduced ablation lesion volumes for all three catheters. In no-flow endocardial CE, both 4 mm and OI catheters produced smaller lesions compared with standard flow. However, the 8 mm catheter produced the largest lesions in a no-flow CE. Ablation performed in an in vivo model with CE resulted in smaller lesions compared with ablation performed in a no-flow environment. No statistically significant differences in steam pops were found among the groups. CONCLUSION: A higher endocardial CE flow can decrease RF effectiveness. Cardiac tissue subjected to no endocardial CE flow may also limit RF for 4 mm catheters, but not for OI catheters; these findings may have implications for RF ablation safety and efficacy, especially in the epicardial space without circulating fluid or in the endocardium under varying flow conditions.


Asunto(s)
Corazón , Miocardio , Animales , Bovinos , Ratas , Diseño de Equipo , Miocardio/patología , Endocardio/cirugía , Catéteres
11.
J Cardiovasc Electrophysiol ; 34(4): 880-887, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36682068

RESUMEN

INTRODUCTION: Esophageal injury is a well-known complication associated with catheter ablation. Though novel methods to mitigate esophageal injury have been developed, few studies have evaluated temperature gradients with catheter ablation across the posterior wall of the left atrium, interstitium, and esophagus. METHODS: To investigate temperature gradients across the tissue, we developed a porcine heart-esophageal model to perform ex vivo catheter ablation on the posterior wall of the left atrium (LA), with juxtaposed interstitial tissue and esophagus. Circulating saline (5 L/min) was used to mimic blood flow along the LA and alteration of ionic content to modulate impedance. Thermistors along the region of interest were used to analyze temperature gradients. Varying time and power, radiofrequency (RF) ablation lesions were applied with an externally irrigated ablation catheter. Ablation strategies were divided into standard approaches (SAs, 10-15 g, 25-35 W, 30 s) or high-power short duration (HPSD, 10-15 g, 40-50 W, 10 s). Temperature gradients, time to the maximum measured temperature, and the relationship between measured temperature as a function of distance from the site of ablation was analyzed. RESULTS: In total, five experiments were conducted each utilizing new porcine posterior LA wall-esophageal specimens for RF ablation (n = 60 lesions each for SA and HPSD). For both SA and HPSD, maximum temperature rise from baseline was markedly higher at the anterior wall (AW) of the esophagus compared to the esophageal lumen (SA: 4.29°C vs. 0.41°C, p < .0001 and HPSD: 3.13°C vs. 0.28°C, p < .0001). Across ablation strategies, the average temperature rise at the AW of the esophagus was significantly higher with SA relative to HPSD ablation (4.29°C vs. 3.13°C, p = .01). From the start of ablation, the average time to reach a maximum temperature as measured at the AW of the esophagus with SA was 36.49 ± 12.12 s, compared to 16.57 ± 4.54 s with HPSD ablation, p < .0001. Fit to a linear scale, a 0.37°C drop in temperature was seen for every 1 cm increase in distance from the site of ablation and thermistor location at the AW of the esophagus. CONCLUSION: Both SA and HPSD ablation strategies resulted in markedly higher temperatures measured at the AW of the esophagus compared to the esophageal lumen, raising concern about the value of clinical intraluminal temperature monitoring. The temperature rise at the AW was lower with HPSD. A significant time delay was seen to reach the maximum measured temperature and a modest increase in distance between the site of ablation and thermistor location impacted the accuracy of monitored temperatures.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Animales , Porcinos , Temperatura , Fibrilación Atrial/cirugía , Atrios Cardíacos , Esófago/lesiones , Ablación por Catéter/métodos
12.
J Cardiovasc Electrophysiol ; 33(4): 690-695, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35133050

RESUMEN

INTRODUCTION: Ablation of papillary muscles (PMs) for refractory ventricular arrhythmias can often be challenging. The catheter approach and orientation during ablation may affect optimal radiofrequency (RF) delivery. Yet, no previous study investigated the association between catheter orientation and PM lesion size. We evaluated ablation lesion characteristics with various catheter orientations relative to the PM tissue during open irrigated ablation, using a standardized, experimental setting. METHODS: Viable bovine PM was positioned on a load cell in a circulating saline bath. RF ablation was performed over PM tissue at 50 W, with the open irrigated catheter positioned either perpendicular or parallel to the PM surface. Applied force was 10 g. Ablation lesions were sectioned and underwent quantitative morphometric analysis. RESULTS: A catheter position oriented directly perpendicular to the PM tissue resulted in the largest ablation lesion volumes and depths compared with ablation with the catheter parallel to PM tissue (75.26 ± 8.40 mm3 vs. 34.04 ± 2.91 mm3 , p < .001) and (3.33 ± 0.18 mm vs. 2.24 ± 0.10 mm, p < .001), respectively. There were no significant differences in initial impedance, peak voltage, peak current, or overall decrease in impedance among groups. Parallel catheter orientation resulted in higher peak temperature (41.33 ± 0.28°C vs. 40.28 ± 0.24°C, p = .003), yet, there were no steam pops in either group. CONCLUSION: For PM ablation, catheter orientation perpendicular to the PM tissue achieves more effective and larger ablation lesions, with greater lesion depth. This may have implications for the chosen ventricular access approach, the type of catheter used, consideration for remote navigation, and steerable sheaths.


Asunto(s)
Ablación por Catéter , Músculos Papilares , Animales , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Catéteres , Bovinos , Ventrículos Cardíacos/cirugía , Músculos Papilares/diagnóstico por imagen , Músculos Papilares/cirugía , Irrigación Terapéutica/efectos adversos , Irrigación Terapéutica/métodos
13.
Rheumatol Int ; 42(10): 1767-1774, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35430712

RESUMEN

COVID-19 raised concern regarding cardiotoxicity and QTc prolongation of hydroxychloroquine (HCQ) and chloroquine (CQ). We examined the frequency and patient factors associated with ECG testing and the detection of prolonged QTc among new HCQ/CQ users in a large academic medical system. 10,248 subjects with a first HCQ/CQ prescription (1/2015-3/2020) were included. We assessed baseline (1 year prior to and including day of initiation of HCQ/CQ through 2 months after initial HCQ/CQ prescription) and follow-up (10 months after the baseline period) patient characteristics and ECGs obtained from electronic health records. Among 8384 female HCQ/CQ new users, ECGs were obtained for 22.3%, 14.3%, and 7.6%, at baseline, follow, and both periods, respectively. Among 1864 male HCQ/CQ new users, ECGs were obtained more frequently at baseline (29.7%), follow-up (18.0%), and both periods (11.3%). Female HCQ/CQ users with a normal QTc at baseline but prolonged QTc (> 470 ms) at follow-up (13.1%) were older at HCQ/CQ initiation [mean 64.7 (SD 16.5) vs. 58.7 (SD 16.9) years, p = 0.004] and more likely to have history of myocardial infarction (41.0% vs. 21.6%, p = 0.0003) compared to those who had normal baseline and follow-up QTc. The frequency of prolonged QTc development was similar (12.4%) among male HCQ/CQ new users (> 450 ms). Prior to COVID-19, ECG testing before and after HCQ/CQ prescription was infrequent, particularly for females who are disproportionately affected by rheumatic diseases and were just as likely to develop prolonged QTc (> 1/10 new users). Prospective studies are needed to guide future management of HCQ/CQ therapy in rheumatic populations.


Asunto(s)
Tratamiento Farmacológico de COVID-19 , COVID-19 , Hidroxicloroquina , COVID-19/epidemiología , Cloroquina/efectos adversos , Electrocardiografía , Femenino , Humanos , Hidroxicloroquina/efectos adversos , Masculino , Prevalencia , SARS-CoV-2 , Centros de Atención Terciaria
15.
J Cardiovasc Electrophysiol ; 32(2): 409-416, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33355965

RESUMEN

INTRODUCTION: Patients with prior cardiac surgery may represent a subgroup of patients with ventricular tachycardia (VT) that may be more difficult to control with catheter ablation. METHODS: We evaluated 1901 patients with ischemic and nonischemic cardiomyopathy who underwent VT ablation at 12 centers. Clinical characteristics and VT radiofrequency ablation procedural outcomes were assessed and compared between those with and without prior cardiac surgery. Kaplan-Meier analysis was used to estimate freedom from recurrent VT and survival. RESULTS: There were 578 subjects (30.4%) with prior cardiac surgery identified in the cohort. Those with prior cardiac surgery were older (66.4 ± 11.0 years vs. 60.5 ± 13.9 years, p < .01), with lower left ventricular ejection fraction (30.2 ± 11.5% vs. 34.8 ± 13.6%, p < .01) and more ischemic heart disease (82.5% vs. 39.3%, p < .01) but less likely to undergo epicardial mapping or ablation (9.0% vs. 38.1%, p<.01) compared to those without prior surgery. When epicardial mapping was performed, a significantly greater proportion required surgical intervention for access (19/52 [36.5%] vs. 14/504 [2.8%]; p < .01). Procedural complications, including epicardial access-related complications, were lower (5.7% vs. 7.0%, p < .01) in patients with versus without prior cardiac surgery. VT-free survival (75.1% vs. 74.1%, p = .805) and survival (86.5% vs. 87.9%, p = .397) were not different between those with and without prior heart surgery, regardless of etiology of cardiomyopathy. VT recurrence was associated with increased mortality in patients with and without prior cardiac surgery. CONCLUSION: Despite different clinical characteristics and fewer epicardial procedures, the safety and efficacy of VT ablation in patients with prior cardiac surgery is similar to others in this cohort. The incremental yield of epicardial mapping in predominant ischemic cardiomyopathy population prior heart surgery may be low but appears safe in experienced centers.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Ablación por Catéter , Taquicardia Ventricular , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Ablación por Catéter/efectos adversos , Humanos , Pericardio/cirugía , Recurrencia , Volumen Sistólico , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía , Resultado del Tratamiento , Función Ventricular Izquierda
16.
Pacing Clin Electrophysiol ; 44(1): 185-188, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-32794265

RESUMEN

A 40-year-old man presented to our emergency department 2 hours after onset of shortness of breath, palpitations, and presyncope secondary to an adenosine-responsive wide complex tachycardia. Electrophysiology study was diagnostic for antidromic atrioventricular (AV) reentrant tachycardia utilizing a muscular connection from the anterior interventricular vein to the left ventricle with Mahaim-like properties, successfully treated with ablation in the distal coronary sinus (CS) system. This case highlights accessory pathways (a) with unique features (i.e., Mahaim-like characteristics) and (b) involving musculature from the distal CS system, thereby limiting the value of endocardial ablation for durable treatment. Importantly, the coronary venous system is an accessible vascular network for evaluation and catheter ablation of such arrhythmias.


Asunto(s)
Ablación por Catéter/métodos , Seno Coronario/cirugía , Taquicardia por Reentrada en el Nodo Atrioventricular/diagnóstico , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía , Fascículo Atrioventricular Accesorio/fisiopatología , Adulto , Diagnóstico Diferencial , Electrocardiografía , Humanos , Masculino , Taquicardia por Reentrada en el Nodo Atrioventricular/fisiopatología
19.
J Cardiovasc Electrophysiol ; 31(7): 1687-1693, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32323395

RESUMEN

BACKGROUND: Interrupted ablation is increasingly proposed as part of high-power short-duration radiofrequency ablation (RFA) strategies and may also result from loss of contact from respiratory patterns or cardiac motion. To study the extent that ablation interruption affects lesions. METHODS: In ex vivo and in vivo experiments, lesion characteristics and tissue temperatures were compared between continuous (group 1) and interrupted (groups 2 and 3) RFA with equal total ablation duration and contact force. Extended duration ablation lesions were also characterized from 1 to 5 minutes. RESULTS: In the ex vivo study, continuous RFA (group 1) produced larger total lesion volumes compared with each interrupted ablation lesion group (273.8 ± 36.5 vs 205.1 ± 34.2 vs 174.3 ± 32.3 mm3 , all P < .001). Peak temperatures for group 1 were higher at 3 and 5 mm than groups 2 and 3. In vivo, continuous ablation resulted in larger lesions, greater lesion depths, and higher tissue temperatures. Longer ablation durations created larger lesion volumes and increased lesion depths. However, after 3 minutes of ablation, the rate of lesion volume, and depth formation decreased. CONCLUSIONS: Continuous RFA delivery resulted in larger and deeper lesions with higher tissue temperatures compared with interrupted ablation. This study may have implications for high-power short duration ablation strategies, motivates strategies to reduce variations in ablation delivery, and provides an upper limit for ablation duration beyond which power delivery has diminishing returns.


Asunto(s)
Ablación por Catéter , Ablación por Radiofrecuencia , Ablación por Catéter/efectos adversos , Calor , Humanos , Ablación por Radiofrecuencia/efectos adversos , Temperatura , Factores de Tiempo
20.
J Cardiovasc Electrophysiol ; 31(5): 1114-1124, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-32031304

RESUMEN

BACKGROUND: Epicardial adipose (EA) tissue may limit effective radiofrequency ablation (RFA). OBJECTIVES: We sought to evaluate the lesion formation of different ablation strategies on ventricular myocardium with overlying EA. METHODS: Bovine myocardium with EA was placed in a circulating saline bath in an ex vivo model. Open-irrigated (OI) RFA was performed, parallel to the myocardium, over fat at 50 W for variable RF durations, variable contact force, catheter configurations (unipolar RF vs bipolar RF), and catheter irrigants (normal saline vs half-normal saline). Ablation was also performed with a needle-tipped ablation catheter (NTAC), perpendicular to the myocardium. RESULTS: Increasingly thick EA attenuated lesion size regardless of ablation strategy. RF applied with longer durations and increasing CF produced larger lesion volumes and deeper lesions with ablation over EA more than 3 mm but was unable to produce measurable lesions when EA less than 3 mm. Similarly, ablation with half normal saline irrigant created slightly deeper lesions than bipolar RF and unipolar RF with normal saline as EA thickness increased, but was unable to produce measurable lesions when EA more than 3 mm. Of all ablation strategies, only NTAC produced effective lesion volumes when ablating over thick (>3 mm) EA. CONCLUSIONS: While EA attenuates lesion depth and size, relatively larger, and deeper lesions can be achieved with longer RFA duration, higher CF, half normal saline irrigant, and, to a greater extent, by utilizing bipolar RF or NTAC, but only over thin adipose (<3 mm). Of those catheters/strategies tested, only NTAC was able to effectively deliver RF over thick (>3 mm) EA with this model.


Asunto(s)
Tejido Adiposo/patología , Adiposidad , Ablación por Catéter , Ventrículos Cardíacos/cirugía , Miocardio/patología , Pericardio/cirugía , Irrigación Terapéutica , Animales , Catéteres Cardíacos , Ablación por Catéter/efectos adversos , Ablación por Catéter/instrumentación , Bovinos , Diseño de Equipo , Ventrículos Cardíacos/patología , Técnicas In Vitro , Tempo Operativo , Pericardio/patología , Irrigación Terapéutica/efectos adversos , Irrigación Terapéutica/instrumentación , Factores de Tiempo
SELECCIÓN DE REFERENCIAS