Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Eur Heart J ; 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38747246

RESUMEN

BACKGROUND AND AIMS: Transcatheter aortic valve implantation (TAVI) has become the first choice to treat older patients with severe symptomatic aortic stenosis (AS). This study aimed to compare TAVI with surgery in low-risk patients ≤ 75 years of age, including both tricuspid and bicuspid AS. METHODS: The NOTION-2 trial enrolled and 1:1 randomized low-risk patients aged ≤ 75 years with severe symptomatic AS to TAVI or surgery. The primary endpoint was a composite of all-cause mortality, stroke or rehospitalization (related to the procedure, valve or heart failure) at 12 months. RESULTS: A total of 370 patients were enrolled with a mean age of 71.1 years and a median Society of Thoracic Surgeons risk score of 1.1%. A total of 100 patients had bicuspid AS. The 1-year incidence of the primary endpoint was 10.2% in the TAVI group and 7.1% in the surgery group (absolute risk difference 3.1%; 95% confidence interval [CI], -2.7% to 8.8%; hazard ratio (HR) 1.4, 95% CI: 0.7 to 2.9; p=0.3). Patients with TAVI, when compared to surgery, had lower risk of major bleeding and new-onset atrial fibrillation and higher risk of non-disabling stroke, permanent pacemaker implantation and moderate-or-greater paravalvular regurgitation. The risk of the primary composite endpoint was 8.7% and 8.3% in patients with tricuspid AS (HR 1.0, 95% CI: 0.5 to 2.3) and 14.3% and 3.9% in patients with bicuspid AS (HR 3.8, 95% CI: 0.8 to 18.5) treated with TAVI or surgery, respectively (P for interaction=0.1). CONCLUSIONS: Among low-risk patients aged ≤ 75 years with severe symptomatic AS, the rate of the composite of death, stroke, or rehospitalization at one year was similar between TAVI and surgery. TAVI outcomes in young bicuspid AS patients warrant caution and should be further investigated. (NOTION-2, ClinicalTrials.gov, NCT02825134).

2.
Am Heart J ; 255: 39-51, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36220354

RESUMEN

BACKGROUND: Coronary artery disease (CAD) frequently coexists with severe aortic valve stenosis (AS) in patients planned for transcatheter aortic valve implantation (TAVI). How to manage CAD in this patient population is still an unresolved question. In particular, it is still not known whether fractional flow reserve (FFR) guided revascularization with percutaneous coronary intervention (PCI) is superior to medical treatment for CAD in terms of clinical outcomes. STUDY DESIGN: The third Nordic Aortic Valve Intervention (NOTION-3) Trial is an open-label investigator-initiated, multicenter multinational trial planned to randomize 452 patients with severe AS and significant CAD to either FFR-guided PCI or medical treatment, in addition to TAVI. Patients are eligible for the study in the presence of at least 1 significant PCI-eligible coronary stenosis. A significant stenosis is defined as either FFR ≤0.80 and/or diameter stenosis >90%. The primary end point is a composite of first occurring all-cause mortality, myocardial infarction, or urgent revascularization (PCI or coronary artery bypass graft performed during unplanned hospital admission) until the last included patient have been followed for 1 year after the TAVI. SUMMARY: NOTION-3 is a multicenter, multinational randomized trial aiming at comparing FFR-guided revascularization vs medical treatment of CAD in patients with severe AS planned for TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Arteria Coronaria , Reserva del Flujo Fraccional Miocárdico , Intervención Coronaria Percutánea , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Intervención Coronaria Percutánea/efectos adversos , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/cirugía , Válvula Aórtica/cirugía , Constricción Patológica , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Angiografía Coronaria
3.
Catheter Cardiovasc Interv ; 97(4): E560-E568, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-32767643

RESUMEN

BACKGROUND: Conduction defects requiring permanent pacemaker (PPM) implantation are frequent complications occurring after surgical (SAVR) and transcatheter aortic valve replacement (TAVR). METHODS: Patients who underwent TAVR or SAVR with a bioprosthesis from the nationwide FinnValve registry were the subjects of this study. Patients with prior PPM, who received a sutureless prosthesis, or required cardiac resynchronization therapy or implantable cardioverter defibrillator were excluded from this analysis. RESULTS: Four thousand and ten patients underwent SAVR and 1,897 underwent TAVR. TAVR had an increased risk of PPM implantation at 30-day (10.1% vs. 3.5%, unadjusted OR 3.11, 95%CI 2.56-3.87) and 5-year (15.7% vs. 8.6%, unadjusted SHR, 2.12, 95%CI 1.81-2.48) compared to SAVR. PPM implantation within 30 days from the index procedure did not increase the risk of 5-year mortality after either SAVR or TAVR. Among 1,042 propensity score matched pairs, TAVR had an increased risk of PPM implantation at 30-day (9.9% vs. 4.7%, p < .0001) and 5-year (14.7% vs. 11.4%, p = .001), but late (>30 days) PPM implantation at 5-year (4.7% vs. 6.9% SHR 0.72, 95%CI 0.47-1.10) was comparable to SAVR. The types of prosthesis had an impact on 30-day PPM implantation after TAVR, but not on late (>30 days) PPM implantation. CONCLUSIONS: Although the risk of 30-day PPM implantation is higher after TAVR compared to SAVR, late (>30 days) PPM implantation was comparable with these treatment methods. PPM implantation within 30 days did not affect late survival.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
4.
Catheter Cardiovasc Interv ; 97(6): 1270-1278, 2021 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-33347739

RESUMEN

OBJECTIVES: To study safety and performance of the MANTA Vascular closure device (VCD) under real world conditions in 10 centers. BACKGROUND: The MANTA is a novel plug-based device for large bore arteriotomy closure. METHODS: We included all eligible patients who underwent transfemoral large bore percutaneous procedures. Exclusion criteria were per operator's discretion and included severe calcification or marked tortuosity of the access vessel, presence of marked obesity/cachexia or a systolic blood pressure above 180 mmHg. The primary performance endpoint was time to hemostasis. Primary and secondary safety endpoints were major and minor access site related vascular complications up to 30 days, respectively. Vascular complications were adjudicated by an independent clinical event committee according to VARC-2 criteria. We performed multivariable logistic regression to estimate the effect of baseline and procedural characteristics on any and major vascular complications. RESULTS: Between February 2018 and July 2019 500 patients were enrolled undergoing Transcatheter aortic valve replacement (TAVR, N = 496), Balloon aortic valvuloplasty (BAV, N = 2), Mechanical circulatory support (MCS, N = 1) or Endovascular aneurysm repair (EVAR, N = 1). Mean age was 80.8 ± 6.6 years with a median STS-score of 2.7 [IQR 2.0-4.3] %. MANTA access site complications were major in 20 (4%) and minor in 28 patients (5.6%). Median time to hemostasis was 50 [IQR 20-120] sec. Severe femoral artery calcification, scar presence in groin, longer procedure duration, female gender and history of hypertension were independent predictors for vascular complications. CONCLUSION: In this study, MANTA appeared to be a safe and effective device for large bore access closure under real-world conditions.


Asunto(s)
Aneurisma de la Aorta Abdominal , Estenosis de la Válvula Aórtica , Implantación de Prótesis Vascular , Cateterismo Periférico , Procedimientos Endovasculares , Reemplazo de la Válvula Aórtica Transcatéter , Dispositivos de Cierre Vascular , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/cirugía , Cateterismo Periférico/efectos adversos , Femenino , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/cirugía , Hemorragia/etiología , Técnicas Hemostáticas/efectos adversos , Humanos , Sistema de Registros , Resultado del Tratamiento
5.
J Cardiothorac Vasc Anesth ; 33(11): 2949-2959, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31350150

RESUMEN

OBJECTIVE: To investigate the prognostic impact of red blood cell (RBC) transfusion on the outcome after transfemoral transcatheter aortic valve replacement (TAVR). DESIGN: Nationwide, retrospective multicenter study. SETTING: Five University Hospitals. PARTICIPANTS: The nationwide FinnValve registry included data from 2,130 patients who underwent TAVR for aortic stenosis from 2008 to 2017. After excluding patients who underwent TAVR through nontransfemoral accesses, 1,818 patients were selected for this analysis. INTERVENTION: TAVR with or without coronary revascularization. MEASUREMENTS AND MAIN RESULTS: RBCs were transfused in 293 patients (16.1%). Time-trend analysis showed that the rates of RBC transfusion decreased significantly from 27.5% in 2012 to 10.0% in 2017 (p < 0.0001). Among 281 propensity score matched pairs, RBC transfusion was associated with higher 30-day mortality (7.1% v 0%, p < 0.0001), late mortality (at 5-year, 59.1% v 43.3%, p = 0.008), as well as increased risk of acute kidney injury (17.0% v 4.4%, p < 0.0001), renal replacement therapy (3.6% v 0.4, p < 0.0001) and prolonged hospital stay (mean, 8.5 v 4.7 days, p < 0.0001) compared with patients who did not receive blood transfusion. In the overall series, the risk of adverse events increased significantly with the increasing amount of transfused RBC units and when operation for excessive bleeding was necessary. Consistently with these findings, postoperative hemoglobin drop and nadir level were associated with higher early and late mortality. CONCLUSIONS: Patients who received blood transfusion after TAVR had an increased risk of early and late adverse events. These adverse effects were particularly evident with increasing amount of RBC transfusion and operations for excessive bleeding.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Transfusión de Eritrocitos/métodos , Hemorragia Posoperatoria/terapia , Puntaje de Propensión , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/mortalidad , Femenino , Finlandia/epidemiología , Estudios de Seguimiento , Mortalidad Hospitalaria/tendencias , Humanos , Masculino , Hemorragia Posoperatoria/mortalidad , Estudios Retrospectivos , Factores de Riesgo , Tasa de Supervivencia/tendencias , Factores de Tiempo
6.
J Gene Med ; 18(7): 124-33, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27203155

RESUMEN

BACKGROUND: Doxorubicin is an effective anticancer drug. The major limitation to its use is the induction of dose-dependent cardiomyopathy. No specific treatment exists for doxorubicin-induced cardiomyopathy and treatments used for other forms of heart failure have only limited beneficial effects. The contraction-relaxation cycle of the heart is controlled by cytosolic calcium concentrations, which, in turn, are critically regulated by the activity of the sarcoplasmic reticulum Ca(2) (+) ATPase (SERCA2a) pump. We hypothesized that SERCA2a gene transfer would ameliorate doxorubicin-induced cardiomyopathy. METHODS: Lentiviral vectors LV-SERCA2a-GFP and LV-GFP were constructed and in vitro gene transfer of LV-SERCA2a-GFP confirmed SERCA2a expression by western blot analysis. Heart failure was induced by giving a single intraperitoneal injection of doxorubicin. LV-SERCA2a-GFP, LV-GFP vectors and phosphate-buffered saline (PBS) were injected under echocardiographic control to the anterior wall of the left ventricle. RESULTS: Echocardiography analyses were performed on the injection day and 28 days postinjection. On the injection day, there were no significant differences in the average ejection fractions (EFs) among SERCA2a (40.0%), GFP (41.1%) and PBS (39.4%) injected animals. On day 28, EF in the SERCA2a group had increased by 16.6 ± 6.7% to 46.4 ± 2.1%. By contrast, EFs in the GFP (40.2 ± 1.3%) and PBS (40.6 ± 1.4%) groups remained at pre-injection levels. In addition, end systolic and end diastolic left ventricle volumes were significantly smaller in the SERCA2a group compared to controls. CONCLUSIONS: SERCA2a gene transfer significantly improves left ventricle function and dimensions in doxorubicin-induced cardiomyopathy, thus making LV-SERCA2a gene transfer an attractive treatment modality for doxorubicin-induced heart failure. Copyright © 2016 John Wiley & Sons, Ltd.


Asunto(s)
Terapia Genética/métodos , Insuficiencia Cardíaca/terapia , Miocardio/metabolismo , ATPasas Transportadoras de Calcio del Retículo Sarcoplásmico/metabolismo , Animales , Doxorrubicina , Ecocardiografía , Técnicas de Transferencia de Gen , Vectores Genéticos/administración & dosificación , Vectores Genéticos/genética , Células HEK293 , Corazón/fisiopatología , Insuficiencia Cardíaca/inducido químicamente , Insuficiencia Cardíaca/genética , Humanos , Lentivirus/genética , Masculino , Ratones Endogámicos C57BL , Miocardio/patología , ATPasas Transportadoras de Calcio del Retículo Sarcoplásmico/genética
7.
Echocardiography ; 33(2): 193-206, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26234651

RESUMEN

BACKGROUND: Population and sex-specific reference limits produced with modern ultrasound equipment are needed for accurate clinical echocardiography diagnostics. We report a comprehensive set of reference limits of cardiac function and dimensions in a group of young and middle-aged Finnish men and women produced by the recommendations of European Society of Echocardiography and American Society of Cardiology. METHODS AND RESULTS: Cardiac structure and function was studied in a standardized comprehensive echocardiographic examination in 1,079 healthy volunteers without cardiovascular diseases or major known risk factors participating in the population-based Young Finns study (444 men and 635 women, age range 34 and 49 years). We present sex-specific reference values for echocardiographic parameters reflecting cardiac structure (ventricular and atrial dimensions and volumes, left ventricular wall thickness and mass, aortic root) and function. From the 86 measured parameters, only 7 were not statistically significantly different between sexes. CONCLUSION: The Young Finns study provides echocardiographic reference ranges for cardiac structure and function quantification that can be utilized to enhance the accuracy or echocardiography diagnostics. The results emphasize the need for sex-specific assessment for most echocardiographic parameters.


Asunto(s)
Enfermedades Cardiovasculares/diagnóstico por imagen , Adulto , Factores de Edad , Enfermedades Cardiovasculares/fisiopatología , Femenino , Finlandia , Humanos , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Valores de Referencia , Reproducibilidad de los Resultados , Factores de Riesgo , Factores Sexuales , Volumen Sistólico
8.
Clin Res Cardiol ; 113(1): 48-57, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37138103

RESUMEN

BACKGROUND: Transaxillary (TAx) transcatheter aortic valve implantation (TAVI) is a preferred alternative access in patients ineligible for transfemoral TAVI. AIMS: This study used the Trans-AXillary Intervention (TAXI) registry to compare procedural success according to different types of transcatheter heart valves (THV). METHODS: For the TAXI registry anonymized data of patients treated with TAx-TAVI were collected from 18 centers. Acute procedural, early and 1-month clinical outcomes were adjudicated in accordance with standardized VARC-3 definitions. RESULTS: From 432 patients, 368 patients (85.3%, SE group) received self-expanding (SE) THV and 64 patients (14.8%, BE group) received balloon-expandable (BE) THV. Imaging revealed lower axillary artery diameters in the SE group (max/min diameter in mm: 8.4/6.6 vs 9.4/6.8 mm; p < 0.001/p = 0.04) but a higher proportion of axillary tortuosity in BE group (62/368, 23.6% vs 26/64, 42.6%; p = 0.004) with steeper aorta-left ventricle (LV) inflow (55° vs 51°; p = 0.002) and left ventricular outflow tract (LVOT)-LV inflow angles (40.0° vs 24.5°; 0.002). TAx-TAVI was more often conducted by right sided axillary artery in the BE group (33/368, 9.0% vs 17/64, 26.6%; p < 0.001). Device success was higher in the SE group (317/368, 86.1% vs 44/64, 68.8%, p = 0.0015). In logistic regression analysis, BE THV were a risk factor for vascular complications and axillary stent implantation. CONCLUSIONS: Both, SE and BE THV can be safely used in TAx-TAVI. However, SE THV were more often used and were associated with a higher rate of device success. While SE THV were associated with lower rates of vascular complications, BE THV were more often used in cases with challenging anatomical circumstances.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Válvula Aórtica/cirugía , Sistema de Registros , Diseño de Prótesis
9.
J Clin Med ; 13(12)2024 Jun 14.
Artículo en Inglés | MEDLINE | ID: mdl-38930026

RESUMEN

Background/Objectives: To date, data regarding the characteristics and management of obstructive, stable coronary artery disease (CAD) encountered in patients undergoing transcatheter aortic valve implantation (TAVI) are sparse. The aim of the study was to analyze granular details, treatment, and outcomes of patients undergoing TAVI with obstructive, stable CAD from real-world practice. Methods: REVASC-TAVI (Management of myocardial REVASCularization in patients undergoing Transcatheter Aortic Valve Implantation with coronary artery disease) is an investigator-initiated, multicenter registry, which collected data from patients undergoing TAVI with obstructive stable CAD found during the pre-TAVI work-up. Results: A total of 2025 patients from 30 centers worldwide with complete follow-up were included in the registry. Most patients had single-vessel CAD (56.1%). An involvement of proximal coronary tracts was detected in 62.5% of cases, with 12.0% of patients having CAD in left main (LM). Most patients received percutaneous coronary intervention (PCI) (n = 1617, 79.9%), especially those with proximal CAD (90.4%). At 2 years, the rates of all-cause death [Kaplan-Meier (KM) estimates 20.1% vs. 18.8%, plog-rank = 0.86] and of the composite of all-cause death, stroke, myocardial infarction, and rehospitalization for heart failure (KM estimates 29.7% vs. 27.5%, plog-rank = 0.82) did not differ between patients undergoing PCI and those who were not. Conclusions: Patients undergoing TAVI with obstructive CAD more commonly had a single-vessel disease and an involvement of proximal coronary tracts. They were commonly treated with PCI, with similar outcomes compared to those treated conservatively.

10.
JACC Cardiovasc Interv ; 17(3): 374-387, 2024 Feb 12.
Artículo en Inglés | MEDLINE | ID: mdl-38180419

RESUMEN

BACKGROUND: The COVID-19 pandemic adversely affected health care systems. Patients in need of transcatheter aortic valve replacement (TAVR) are especially susceptible to treatment delays. OBJECTIVES: This study sought to evaluate the impact of the COVID-19 pandemic on global TAVR activity. METHODS: This international registry reported monthly TAVR case volume in participating institutions prior to and during the COVID-19 pandemic (January 2018 to December 2021). Hospital-level information on public vs private, urban vs rural, and TAVR volume was collected, as was country-level information on socioeconomic status, COVID-19 incidence, and governmental public health responses. RESULTS: We included 130 centers from 61 countries, including 65,980 TAVR procedures. The first and second pandemic waves were associated with a significant reduction of 15% (P < 0.001) and 7% (P < 0.001) in monthly TAVR case volume, respectively, compared with the prepandemic period. The third pandemic wave was not associated with reduced TAVR activity. A greater reduction in TAVR activity was observed in Africa (-52%; P = 0.001), Central-South America (-33%; P < 0.001), and Asia (-29%; P < 0.001). Private hospitals (P = 0.005), urban areas (P = 0.011), low-volume centers (P = 0.002), countries with lower development (P < 0.001) and economic status (P < 0.001), higher COVID-19 incidence (P < 0.001), and more stringent public health restrictions (P < 0.001) experienced a greater reduction in TAVR activity. CONCLUSIONS: TAVR procedural volume declined substantially during the first and second waves of the COVID-19 pandemic, especially in Africa, Central-South America, and Asia. National socioeconomic status, COVID-19 incidence, and public health responses were associated with treatment delays. This information should inform public health policy in case of future global health crises.


Asunto(s)
Estenosis de la Válvula Aórtica , COVID-19 , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Pandemias , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/epidemiología , Resultado del Tratamiento , COVID-19/epidemiología , Sistema de Registros , Factores de Riesgo
11.
Histochem Cell Biol ; 139(1): 161-71, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23007289

RESUMEN

The small extracellular matrix proteoglycan decorin which possesses a potent antitumor activity has been shown to be present in various amounts in the stroma of several tumors including those of the breast. Regarding decorin in breast malignancies the published data are conflicting, i.e., whether breast cancer cells express it or not. Here, we first compared decorin gene expression levels between healthy human breast tissue and selected types of human breast cancer using GeneSapiens databank. Next, we localized decorin mRNA in tissue specimen of normal human breast, intraductal breast papillomas and various histologic types of human breast cancer using in situ hybridization (ISH) with digoxigenin-labeled RNA probes for decorin. We also examined the effect of decorin transduction on the behavior of cultured human breast cancer MCF7 cells. Analysis of GeneSapiens databank revealed that in various human breast cancers decorin expression is significant. However, ISH results clearly demonstrated that human breast cancer cells independently of the type of the cancer do not express decorin mRNA. This was also true for papilloma-forming cells of the human breast. Indeed, decorin gene expression in healthy human breast tissue as well as in benign and malignant tumors of human breast was shown to take place solely in cells of the original stroma. Decorin transduction using decorin adenoviral vector in decorin-negative MCF7 cells resulted in a significant decrease in the proliferation of these cells and changed cell cohesion. Decorin-transduced MCF7 cells also exhibited increased apoptosis. In conclusion, our study shows that in human breast tissue only cells of the original stroma are capable of decorin gene expression. Our study also shows that transduction of decorin in decorin-negative human breast cancer cells markedly modulates the growth pattern of these cells.


Asunto(s)
Neoplasias de la Mama/metabolismo , Carcinoma/metabolismo , Decorina/metabolismo , Adulto , Anciano , Anciano de 80 o más Años , Apoptosis , Neoplasias de la Mama/genética , Neoplasias de la Mama/patología , Carcinoma/genética , Carcinoma/patología , Adhesión Celular , Proliferación Celular , Decorina/genética , Femenino , Perfilación de la Expresión Génica , Regulación Neoplásica de la Expresión Génica , Humanos , Hibridación in Situ , Células MCF-7 , Persona de Mediana Edad , ARN Mensajero/metabolismo , Células del Estroma/metabolismo , Células del Estroma/patología , Transducción Genética , Transfección
12.
Cardiol Ther ; 12(2): 361-369, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36899283

RESUMEN

INTRODUCTION: During the transcatheter aortic valve replacement (TAVR) procedure, hemodynamic measurements can be used to evaluate transcatheter heart valve (THV) performance. We hypothesized that the occurrence of a significant decrease in invasive aortic pressure immediately after annular contact by a self-expanding THV indicates effective annular sealing. This phenomenon could thus be used as a marker for the occurrence of paravalvular leak (PVL). METHODS: Thirty-eight patients undergoing TAVR procedure with a self-expandable Evolut R or Evolut Pro (Medtronic) valve prosthesis were included in the study. Drop in aortic pressure during valve expansion was defined as a decrease in systolic pressure of 30 mmHg immediately after annular contact. The primary endpoint was the occurrence of more than mild PVL immediately after valve implantation. RESULTS: A pressure drop was seen in 60.5% (23/38) of patients. More than mild PVL requiring balloon post-dilatation (BPD) was significantly more frequent in patients who did not have a systolic pressure decrease > 30 mmHg during valve implantation (46.7% [7/15] vs. 13.0% [3/23], respectively; p = 0.03). Patients without a systolic pressure decrease > 30 mmHg also had a lower mean cover index on computed tomography analysis (16.2% vs. 13.3%; p = 0.016). The 30-day outcomes were similar between the two groups, and echocardiography at 30 days demonstrated more than none/trace PVL in 21.1% (8/38) of patients, with no difference between the two groups. CONCLUSION: A decrease in aortic pressure after annular contact is associated with an increased probability of good hemodynamic outcome after self-expanding TAVR implantation. In addition to other methods, this parameter could be used as an additional marker for optimal valve positioning and hemodynamic outcome during the implantation procedure.

13.
EuroIntervention ; 19(7): 589-599, 2023 Sep 18.
Artículo en Inglés | MEDLINE | ID: mdl-37436190

RESUMEN

BACKGROUND: The optimal timing to perform percutaneous coronary interventions (PCI) in transcatheter aortic valve implantation (TAVI) patients remains unknown. AIMS: We sought to compare different PCI timing strategies in TAVI patients. METHODS: The REVASC-TAVI registry is an international registry including patients undergoing TAVI with significant, stable coronary artery disease (CAD) at preprocedural workup. In this analysis, patients scheduled to undergo PCI before, after or concomitantly with TAVI were included. The main endpoints were all-cause death and a composite of all-cause death, stroke, myocardial infarction (MI) or rehospitalisation for congestive heart failure (CHF) at 2 years. Outcomes were adjusted using the inverse probability treatment weighting (IPTW) method. RESULTS: A total of 1,603 patients were included. PCI was performed before, after or concomitantly with TAVI in 65.6% (n=1,052), 9.8% (n=157) or 24.6% (n=394), respectively. At 2 years, all-cause death was significantly lower in patients undergoing PCI after TAVI as compared with PCI before or concomitantly with TAVI (6.8% vs 20.1% vs 20.6%; p<0.001). Likewise, the composite endpoint was significantly lower in patients undergoing PCI after TAVI as compared with PCI before or concomitantly with TAVI (17.4% vs 30.4% vs 30.0%; p=0.003). Results were confirmed at landmark analyses considering events from 0 to 30 days and from 31 to 720 days. CONCLUSIONS: In patients with severe aortic stenosis and stable coronary artery disease scheduled for TAVI, performance of PCI after TAVI seems to be associated with improved 2-year clinical outcomes compared with other revascularisation timing strategies. These results need to be confirmed in randomised clinical trials.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Arteria Coronaria , Infarto del Miocardio , Intervención Coronaria Percutánea , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Enfermedad de la Arteria Coronaria/cirugía , Enfermedad de la Arteria Coronaria/complicaciones , Intervención Coronaria Percutánea/métodos , Estenosis de la Válvula Aórtica/terapia , Infarto del Miocardio/complicaciones , Resultado del Tratamiento , Válvula Aórtica/cirugía , Factores de Riesgo
14.
Virol J ; 9: 296, 2012 Nov 29.
Artículo en Inglés | MEDLINE | ID: mdl-23190872

RESUMEN

BACKGROUND: Clinical gene therapy trials for cardiovascular diseases have demonstrated the crucial role of efficient gene delivery and transfection technologies in achieving clinically relevant results. We hypothesized that the use of tropism-modified adenoviruses would improve transduction efficacy and to this end we analyzed the transduction efficiency and toxicity of standard Ad5 and tropism-modified Ad5/35 in combination with ultrasound-guided intramyocardial gene delivery. METHODS: Ultrasound-guided intracardiac injections were used to deliver 1 × 10(10) pfu/ml Ad5-lacZ and Ad5/35-lacZ vectors into mouse left ventricle wall. Since Ad5/35 uses human CD46 as its primary receptor, we used transgenic hCD46Ge mice expressing human CD46 at levels comparable to man. Mice were sacrificed 6 or 14 days post-injection and immunohistochemistry and X-gal staining were used to detect transgene and viral receptor expression. Virus-induced cardiac toxicity was evaluated by a pathologist. RESULTS: The intramyocardial injection was well tolerated and both Ad5-lacZ and Ad5/35-lacZ were able to give robust transgene expression after a single injection. Interestingly, while Ad5-lacZ was able to generate greater transgene expression than Ad5/35-lacZ, it also evoked more severe tissue damage with large areas of interstitial inflammatory cell infiltration and myocyte necrosis. CONCLUSIONS: Ultrasound-guided intramyocardial injection is an effective and safe way to deliver vectors to the heart. The observed severe tissue damage of Ad5-lacZ greatly undermines the efficient transgene expression and suggests that Ad5/35 capsid modification can result in safer adenoviral vectors for cardiovascular gene therapy, although at the cost of some vector transduction efficacy.


Asunto(s)
Adenoviridae/genética , Proteínas de la Cápside/genética , Vectores Genéticos/administración & dosificación , Vectores Genéticos/toxicidad , Adenoviridae/clasificación , Adenoviridae/inmunología , Animales , Proteínas de la Cápside/inmunología , Citocinas/sangre , Citocinas/inmunología , Expresión Génica , Técnicas de Transferencia de Gen , Humanos , Inflamación/inmunología , Inflamación/metabolismo , Inflamación/virología , Inyecciones , Proteína Cofactora de Membrana/genética , Proteína Cofactora de Membrana/metabolismo , Ratones , Ratones Transgénicos , Miocardio/inmunología , Miocardio/metabolismo , Miocardio/patología , Transgenes
15.
J Cardiothorac Surg ; 17(1): 322, 2022 Dec 18.
Artículo en Inglés | MEDLINE | ID: mdl-36529781

RESUMEN

BACKGROUND: Patients with severe aortic stenosis and left ventricular systolic dysfunction have a poor prognosis, and this may result in inferior survival also after aortic valve replacement. The outcomes of transcatheter and surgical aortic valve replacement were investigated in this comparative analysis. METHODS: The retrospective nationwide FinnValve registry included data on patients who underwent transcatheter or surgical aortic valve replacement with a bioprosthesis for severe aortic stenosis. Propensity score matching was performed to adjust the outcomes for baseline covariates of patients with reduced (≤ 50%) left ventricular ejection fraction. RESULTS: Within the unselected, consecutive 6463 patients included in the registry, the prevalence of reduced ejection fraction was 20.8% (876 patients) in the surgical cohort and 27.7% (452 patients) in the transcatheter cohort. Reduced left ventricular ejection fraction was associated with decreased survival (adjusted hazards ratio 1.215, 95%CI 1.067-1.385) after a mean follow-up of 3.6 years. Among 255 propensity score matched pairs, 30-day mortality was 3.1% after transcatheter and 7.8% after surgical intervention (p = 0.038). One-year and 4-year survival were 87.5% and 65.9% after transcatheter intervention and 83.9% and 69.6% after surgical intervention (restricted mean survival time ratio, 1.002, 95%CI 0.929-1.080, p = 0.964), respectively. CONCLUSIONS: Reduced left ventricular ejection fraction was associated with increased morbidity and mortality after surgical and transcatheter aortic valve replacement. Thirty-day mortality was higher after surgery, but intermediate-term survival was comparable to transcatheter intervention. Trial registration The FinnValve registry ClinicalTrials.gov Identifier: NCT03385915.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Disfunción Ventricular Izquierda , Humanos , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Estudios Retrospectivos , Factores de Riesgo , Volumen Sistólico , Resultado del Tratamiento , Disfunción Ventricular Izquierda/complicaciones , Función Ventricular Izquierda
16.
Panminerva Med ; 64(4): 427-437, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35638242

RESUMEN

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is an established management strategy for severe aortic valve stenosis. Percutaneous axillary approach for TAVI holds the promise of improving safety without jeopardizing effectiveness in comparison to surgical access. We aimed at appraising the comparative effectiveness of percutaneous vs. surgical axillary approaches for TAVI. METHODS: We performed an international retrospective observational study using de-identified details on baseline, procedural, and 1-month follow-up features. Valve Academic Research Consortium (VARC)-3 criteria were applied throughout. Outcomes of interest were clinical events up to 1 month of follow-up, compared with unadjusted and propensity score-adjusted analyses. RESULTS: A total of 432 patients were included, 189 (43.8%) receiving surgical access, and 243 (56.2%) undergoing percutaneous access. Primary hemostasis failure was more common in the percutaneous group (13.2% vs. 4.2%, P<0.001), leading to more common use of covered stent implantation (13.2% vs. 3.7%, P<0.001). Irrespectively, percutaneous access was associated with shorter hospital stay (-2.6 days [95% confidence interval: -5.0; -0.1], P=0.038), a lower risk of major adverse events (a composite of death, myocardial infarction, stroke, type 3 bleeding, and major access-site related complication; odds ratio=0.44 [0.21; 0.95], P=0.036), major access-site non-vascular complications (odds ratio=0.21 [0.06; 0.77], P=0.018), and brachial plexus impairment (odds ratio=0.16 [0.03; 0.76], P=0.021), and shorter hospital stay (-2.6 days [-5.0; -0.1], P=0.038). CONCLUSIONS: Percutaneous axillary access provides similar or better results than surgical access in patients undergoing TAVI with absolute or relative contraindications to femoral access.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Sistema de Registros , Estudios Retrospectivos , Válvula Aórtica/cirugía , Factores de Riesgo
17.
Circ Cardiovasc Interv ; 15(12): e012417, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36538579

RESUMEN

BACKGROUND: The best management of stable coronary artery disease (CAD) in patients undergoing transcatheter aortic valve implantation (TAVI) is still unclear due to the marked inconsistency of the available evidence. METHODS: The REVASC-TAVI registry (Management of Myocardial Revascularization in Patients Undergoing Transcatheter Aortic Valve Implantation With Coronary Artery Disease) collected data from 30 centers worldwide on patients undergoing TAVI who had significant, stable CAD at preprocedural work-up. For the purposes of this analysis, patients with either complete or incomplete myocardial revascularization were compared in a propensity score matched analysis, to take into account of baseline confounders. The primary and co-primary outcomes were all-cause death and the composite of all-cause death, stroke, myocardial infarction, and rehospitalization for heart failure, respectively, at 2 years. RESULTS: Among 2407 patients enrolled, 675 pairs of patients achieving complete or incomplete myocardial revascularization were matched. The primary (21.6% versus 18.2%, hazard ratio' 0.88 [95% CI, 0.66-1.18]; P=0.38) and co-primary composite (29.0% versus 27.1%, hazard ratio' 0.97 [95% CI, 0.76-1.24]; P=0.83) outcome did not differ between patients achieving complete or incomplete myocardial revascularization, respectively. These results were consistent across different prespecified subgroups of patients (< or >75 years of age, Society of Thoracic Surgeons score > or <4%, angina at baseline, diabetes, left ventricular ejection fraction > or <40%, New York Heart Association class I/II or III/IV, renal failure, proximal CAD, multivessel CAD, and left main/proximal anterior descending artery CAD; all P values for interaction >0.10). CONCLUSIONS: The present analysis of the REVASC-TAVI registry showed that, among TAVI patients with significant stable CAD found during the TAVI work-up, completeness of myocardial revascularization achieved either staged or concomitantly with TAVI was similar to a strategy of incomplete revascularization in reducing the risk of all cause death, as well as the risk of death, stroke, myocardial infarction, and rehospitalization for heart failure at 2 years, regardless of the clinical and anatomical situations.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Arteria Coronaria , Infarto del Miocardio , Intervención Coronaria Percutánea , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/complicaciones , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Volumen Sistólico , Factores de Riesgo , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Resultado del Tratamiento , Función Ventricular Izquierda , Revascularización Miocárdica/efectos adversos , Infarto del Miocardio/complicaciones , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Intervención Coronaria Percutánea/efectos adversos
18.
Clin Res Cardiol ; 110(3): 429-439, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33099681

RESUMEN

OBJECTIVES: To compare the outcomes after surgical (SAVR) and transcatheter aortic valve replacement (TAVR) for severe stenosis of bicuspid aortic valve (BAV). METHODS: We evaluated the early and mid-term outcome of patients with stenotic BAV who underwent SAVR or TAVR for aortic stenosis from the nationwide FinnValve registry. RESULTS: The FinnValve registry included 6463 AS patients and 1023 (15.8%) of them had BAV. SAVR was performed in 920 patients and TAVR in 103 patients with BAV. In the overall series, device success after TAVR was comparable to SAVR (94.2% vs. 97.1%, p = 0.115). TAVR was associated with increased rate of mild-to-severe paravalvular regurgitation (PVR) (19.4% vs. 7.9%, p < 0.0001) and of moderate-to-severe PVR (2.9% vs. 0.7%, p = 0.053). When newer-generation TAVR devices were evaluated, mild-to-severe PVR (11.9% vs. 7.9%, p = 0.223) and moderate-to-severe PVR (0% vs. 0.7%, p = 1.000) were comparable to SAVR. Type 1 N-L and type 2 L-R/R-N were the BAV morphologies with higher incidence of mild-to-severe PVR (37.5% and 100%, adjusted for new-generation prostheses p = 0.025) compared to other types of BAVs. Among 75 propensity score-matched cohorts, 30-day mortality was 1.3% after TAVR and 5.3% after SAVR (p = 0.375), and 2-year mortality was 9.7% after TAVR and 18.7% after SAVR (p = 0.268) CONCLUSIONS: In patients with stenotic BAV, TAVR seems to achieve early and mid-term results comparable to SAVR. Type 1 N-L and type 2 L-R/R-N BAV morphologies had higher incidence of PVR. Larger studies evaluating different phenotypes of BAV are needed to confirm these findings. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT03385915.


Asunto(s)
Válvula Aórtica/cirugía , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Prótesis Valvulares Cardíacas , Puntaje de Propensión , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Válvula Aórtica/diagnóstico por imagen , Enfermedad de la Válvula Aórtica Bicúspide/diagnóstico , Femenino , Estudios de Seguimiento , Humanos , Masculino , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
19.
Can J Cardiol ; 37(1): 37-46, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-32535038

RESUMEN

BACKGROUND: The data on acute kidney injury (AKI) in patients without chronic kidney disease (CKD) after transcatheter aortic valve replacement (TAVR) are limited. The study sought to compare the incidence of AKI and its impact on 5-year mortality after TAVR and surgical aortic valve replacement (SAVR) in patients without CKD. METHODS: This registry included data from 6463 consecutive patients who underwent TAVR or SAVR. CKD was defined as estimated glomerular filtration rate <60 mL/min/1.73 m2. AKI was defined according to the Kidney Disease Improving Global Outcomes criteria. For sensitivity analysis, propensity-score matching between TAVR and SAVR was performed. RESULTS: The study included 4555 consecutive patients (TAVR, n = 1215 and SAVR, n = 3340) without CKD. Propensity-score matching identified 542 pairs. Patients who underwent TAVR had a significantly lower incidence of AKI in comparison to those who underwent SAVR (unmatched 4.7% vs 16.4%, P < 0.001, multivariable analysis: odds ratio, 0.29, 95% confidence interval [CI], 0.20-0.41; matched 5.9% vs 19.0%, P < 0.001). Patients with AKI had significantly increased 5-year mortality compared with those without AKI (unmatched 36.0% vs 19.1%, log-rank P < 0.001; matched 36.3% vs 24.0%, log-rank P < 0.001). The adjusted hazard ratios for 5-year mortality were 1.58 (95% CI, 1.20-2.08) for AKI grade 1, 3.27 (95% CI, 2.09-5.06) for grade 2, and 4.82 (95% CI, 2.93-8.04) for grade 3. CONCLUSIONS: TAVR in patients without CKD was associated with a significantly less frequent incidence of AKI compared with SAVR. AKI significantly increased the risk of 5-year mortality after either TAVR or SAVR, and increasing severity of AKI was incrementally associated with 5-year mortality.


Asunto(s)
Lesión Renal Aguda/etiología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Lesión Renal Aguda/mortalidad , Anciano , Anciano de 80 o más Años , Femenino , Finlandia/epidemiología , Tasa de Filtración Glomerular , Humanos , Masculino , Análisis por Apareamiento , Análisis Multivariante , Complicaciones Posoperatorias , Sistema de Registros , Estudios Retrospectivos , Índice de Severidad de la Enfermedad
20.
Histochem Cell Biol ; 133(3): 349-57, 2010 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-19957088

RESUMEN

Gene therapy trials for heart failure have demonstrated the key role of efficient gene transfer in achieving therapeutic efficacy. An attractive approach to improve adenoviral gene transfer is to use alternative virus serotypes with modified tropism. We performed a detailed analysis of cardiac expression of receptors for several adenovirus serotypes with a focus on differential expression of CAR and CD46, as adenoviruses targeting these receptors have been used in various applications. Explanted hearts from patients with DCM and healthy donors were analyzed using Q-RT-PCR, western blot and immunohistochemistry. Q-RT-PCR and Western analyses revealed robust expression of all receptors except CD80 in normal hearts with lower expression levels in DCM. Immunohistochemical analyses demonstrated that CD46 expression was somewhat higher than CAR both in normal and DCM hearts with highest levels of expression in intramyocardial coronary vessels. Total CAR expression was upregulated in DCM. Triple staining on these vessels demonstrated that both CAR and CD46 were confined to the subendothelial layer in normal hearts. The situation was clearly different in DCM, where both CAR and CD46 were expressed by endothelial cells. The induction of expression of CAR and CD46 by endothelial cells in DCM suggests that viruses targeting these receptors could more easily gain entry to heart cells after intravascular administration. This finding thus has potential implications for the development of targeted gene therapy for heart failure.


Asunto(s)
Cardiomiopatía Dilatada/genética , Cardiomiopatía Dilatada/metabolismo , Proteína Cofactora de Membrana/genética , Proteína Cofactora de Membrana/metabolismo , Miocardio/metabolismo , Receptores Virales/genética , Receptores Virales/metabolismo , Adolescente , Adulto , Western Blotting , Proteína de la Membrana Similar al Receptor de Coxsackie y Adenovirus , Femenino , Perfilación de la Expresión Génica , Humanos , Inmunohistoquímica , Masculino , Persona de Mediana Edad , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA