Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Am J Cardiol ; 139: 97-104, 2021 01 15.
Artículo en Inglés | MEDLINE | ID: mdl-33002463

RESUMEN

The role of central sleep apnea (CSA) in pacing-induced cardiomyopathy (PICM) remains speculative. In a prospective trial entitled UPGRADE, the presence of CSA was assessed by single-night polysomnography (PSG) in 54 PICM patients within 1 month after left ventricular lead implantation (with biventricular stimulation still not activated). CSA was diagnosed in half of patients (n = 27). Patients with moderate or severe CSA were randomized to cardiac resynchronization therapy (CRT) versus right ventricular pacing (RVP) in a double-blinded cross-over design and re-scheduled for a follow-up PSG within 3 to 5 months. After crossing-over of stimulation mode another PSG was conducted 3 to 5 months later. CRT led to a significant increase in left ventricular ejection fraction and significant reduction in left ventricular end systolic volumes and N-terminal pro brain natriuretic peptide plasma levels, whereas no significant effects were observed with ongoing RVP. CSA was significantly improved after 3.9 (3.2 to 4.4) months of CRT: apnea-hypopnea index decreased from 39.1 (32.1 to 54.0) events per hour at baseline to 22.2/h (10.9 to 36.7) by CRT (p <0.001). Central apnea index decreased from 27.1/h (17.7 to 36.1) at baseline to 6.8/h (1.1 to 14.4) after CRT activation (p <0.001). Ongoing RVP yielded only a minor improvement in apnea-hypopnea index and central apnea index. Pre-existent CSA did not affect structural response rate and had no impact on mid-term follow-up (median 2.8 years). In conclusion, CSA is highly prevalent in patients with PICM. CRT upgrading significantly improves CSA leading to a similar outcome in PICM patients without pre-existent CSA.


Asunto(s)
Estimulación Cardíaca Artificial/efectos adversos , Cardiomiopatías/etiología , Insuficiencia Cardíaca/terapia , Apnea Central del Sueño/complicaciones , Volumen Sistólico/fisiología , Función Ventricular Izquierda/fisiología , Anciano , Cardiomiopatías/diagnóstico , Cardiomiopatías/fisiopatología , Ecocardiografía , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Polisomnografía , Estudios Prospectivos , Apnea Central del Sueño/fisiopatología
2.
Data Brief ; 33: 106461, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33294502

RESUMEN

This article contains supplemental data to the publication "Central Sleep Apnea and Pacing-Induced Cardiomyopathy" [1], which was the most recent publication of the "UPGRADE" study. It provides in-depth analysis of the effects of cardiac resynchronisation therapy (CRT) in patients suffering from pacing-induced cardiomyopathy (PICM) on cardiac remodeling as well as functional cardiac parameters in comparison to continuous right ventricular pacing (RVP). Furthermore, it also covers additional data on several sleep parameters, which were not presented in the main article including the index for obstructive sleep apnea (OSA), the index for mixed sleep apnea and the oxygen saturation measurements during polysomnography. Further, Kaplan-Meier curves are presented for major adverse cardiac events (MACE) and overall mortality by severity of sleep apnea. Generally, the "UGRADE" study was a single-center prospective double-blinded randomized controlled trial lasting from 2014 to 2020. The methodology included a cross-over design giving the possibility to detect differences while CRT was activated and while continuous RVP was applied. The presented data should aid clinicians in daily practice as upgrading to CRT is not limited to improvement in cardiac parameters, but also modifies sleep apnea in patients with PICM, a generally sparsely studied entity of heart failure.

3.
PLoS One ; 14(9): e0222269, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31498840

RESUMEN

OBJECTIVES: To evaluate the long-term performance of the SonRtip atrial lead. BACKGROUND: To optimize atrioventricular and interventricular timing and thereby potentially improving cardiac resynchronization therapy (CRT) responder rates, a lead integrated technology and a cardioverter/defibrillator-based algorithm measuring peak endocardial acceleration have been introduced. Long-term performance of the atrial lead (SonRtip PS55D, Sorin/MicroPort CRM, Italy) embedded with such a sensor has not been reported so far. METHODS: Between 2012 and 2018, 143 patients underwent implantation of the SonRtip atrial lead in four Austrian medical centers. Conventional bipolar atrial leads implanted during the same period in 526 patients receiving CRT were used as control cohort. RESULTS: Among 669 patients included in the study, 10 (1.5%) showed increased atrial pacing thresholds and/or decreased atrial sensing amplitudes and/or sudden increase in atrial lead impedance (above 3000 Ω) after an uneventful early postoperative period. Seven (70%) of the malfunctioning leads were SonRtip leads (p <0.001). Lead replacement was needed in 4.2% of SonRtip leads (six out of 143) and in 0.38% of all other conventional atrial leads (two out of 526) (p <0.001). Because of unaltered atrial sensing properties, a wait and see strategy was chosen in two patients-one of them with a SonRtip lead. The implanted atrial lead in the latter person experienced a sudden increase in pacing threshold (4V/0.35ms). CONCLUSIONS: While short-term safety and stable technical performance of the SonRtip atrial lead could be confirmed, our study found an unexpectedly high malfunction rate over a longer follow-up period.


Asunto(s)
Fibrilación Atrial/terapia , Dispositivos de Terapia de Resincronización Cardíaca , Terapia de Resincronización Cardíaca , Contracción Miocárdica , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/fisiopatología , Falla de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad
4.
PLoS One ; 13(4): e0195573, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29624601

RESUMEN

BACKGROUND: Sleep disordered breathing is a common but often undiagnosed comorbidity in heart failure patients. Cardiac implantable electronic devices used for cardiac resynchronization therapy (CRT) may detect sleep apnea by use of a transthoracic impedance sensor. Validation of the AP scan® algorithm (Boston Scientific®) was performed by using the diagnostic gold standard polysomnography (PSG). METHODS: Forty-one patients with impaired left ventricular ejection fraction, frequent right ventricular pacing due to atrioventricular block and heart failure symptoms despite optimal medical therapy underwent upgrading to biventricular pacing. Within one month after left ventricular lead implantation, sleep apnea was assessed by single-night PSG and AP scan® measurements. RESULTS: AP scan® measurements were valid in only 21 of 41 (51.2%) patients in the index night of the PSG. The PSG determined apnea-hypopnea index did not correlate statistically significant with the AP scan® measurements (r = 0.41, 95% confidence interval -0.05-0.72, p = 0.07). The degree of overestimation is displayed by using the Bland-Altman method: mean difference -12.4, standard deviation ± 15.8, 95% confidence interval -43.3-18.6. CONCLUSIONS: In heart failure patients receiving CRT upgrading, the AP scan® algorithm may need further improvement before it can be recommended for sleep apnea detection.


Asunto(s)
Dispositivos de Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca/complicaciones , Polisomnografía , Síndromes de la Apnea del Sueño/complicaciones , Síndromes de la Apnea del Sueño/diagnóstico , Anciano , Algoritmos , Terapia de Resincronización Cardíaca , Dispositivos de Terapia de Resincronización Cardíaca/estadística & datos numéricos , Cardiografía de Impedancia , Estudios Cruzados , Método Doble Ciego , Femenino , Insuficiencia Cardíaca/terapia , Humanos , Masculino , Polisomnografía/estadística & datos numéricos , Disfunción Ventricular Izquierda/complicaciones , Disfunción Ventricular Izquierda/terapia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA