RESUMEN
PURPOSE: Free water in cortical bone is either contained in nearly cylindrical structures (mainly Haversian canals oriented parallel to the bone axis) or in more spherically shaped pores (lacunae). Those cavities have been reported to crucially influence bone quality and mechanical stability. Susceptibility differences between bone and water can lead to water frequency shifts dependent on the geometric characteristics. The purpose of this study is to calculate and measure the frequency distribution of the water signal in MRI in dependence of the microscopic bone geometry. METHODS: Finite element modeling and analytical approaches were performed to characterize the free water components of bone. The previously introduced UTE-FID technique providing spatially resolved FID-spectra was used to measure the frequency distribution pixel-wise for different orientations of the bone axis. RESULTS: The frequency difference between free water in spherical pores and in canals parallel to B0 amounts up to approximately 100 Hz at 3T. Simulated resonance frequencies showed good agreement with the findings in UTE-FID spectra. The intensity ratio of the two signal components (parallel canals and spherical pores) was found to vary between periosteal and endosteal regions. CONCLUSION: Spatially resolved UTE-FID examinations allow the determination of the frequency distribution of signals from free water in cortical bone. This frequency distribution indicates the composition of the signal contributions from nearly spherical cavities and cylindrical canals which allows for further characterization of bone structure and status.
Asunto(s)
Agua Corporal , Simulación por Computador , Imagen por Resonancia Magnética , Humanos , Imagen por Resonancia Magnética/métodos , Agua Corporal/diagnóstico por imagen , Algoritmos , Reproducibilidad de los Resultados , Modelos Biológicos , Sensibilidad y Especificidad , Interpretación de Imagen Asistida por Computador/métodos , Agua/química , Huesos/diagnóstico por imagen , Aumento de la Imagen/métodos , Análisis de Elementos FinitosRESUMEN
OBJECTIVE: To prepare and analyze soy-lecithin-agar gels for non-toxic relaxometry phantoms with tissue-like relaxation times at 3T. METHODS: Phantoms mimicking the relaxation times of various tissues (gray and white matter, kidney cortex and medulla, spleen, muscle, liver) were built and tested with a clinical 3T whole-body MR scanner. Simple equations were derived to calculate the appropriate concentrations of soy lecithin and agar in aqueous solutions to achieve the desired relaxation times. Phantoms were tested for correspondence between measurements and calculated T1 and T2 values, reproducibility, spatial homogeneity, and temporal stability. T1 and T2 mapping techniques and a 3D T1-weighted sequence with high spatial resolution were applied. RESULTS: Except for the liver relaxation phantom, all phantoms were successfully and reproducibly produced. Good agreement was found between the targeted and measured relaxation times. The percentage deviations from the targeted relaxation times were less than 3% for T1 and less than 6.5% for T2. In addition, the phantoms were homogeneous and had little to no air bubbles. However, the phantoms were unstable over time: after a storage period of 4 weeks, mold growth and also changes in relaxation times were detected in almost all phantoms. CONCLUSION: Soy-lecithin-agar gels are a non-toxic material for the construction of relaxometry phantoms with tissue-like relaxation times. They are easy to prepare, inexpensive and allow independent adjustment of T1 and T2. However, there is still work to be done to improve the long-term stability of the phantoms.
Asunto(s)
Agar , Lecitinas , Hígado , Imagen por Resonancia Magnética , Fantasmas de Imagen , Imagen por Resonancia Magnética/métodos , Humanos , Agar/química , Reproducibilidad de los Resultados , Hígado/diagnóstico por imagen , Lecitinas/química , Geles/química , Riñón/diagnóstico por imagen , Glycine max , Bazo/diagnóstico por imagen , Sustancia Gris/diagnóstico por imagen , Imagenología Tridimensional/métodos , Imagen de Cuerpo Entero/métodos , Procesamiento de Imagen Asistido por Computador/métodosRESUMEN
PURPOSE: To test soy lecithin as a substance added to water for the construction of MRI phantoms with tissue-like diffusion coefficients. The performance of soy lecithin was assessed for the useable range of adjustable ADC values, the degree of non-Gaussian diffusion, simultaneous effects on relaxation times, and spectral signal properties. METHODS: Aqueous soy lecithin solutions of different concentrations (0%, 0.5%, 1%, 2%, 3% , 10%) and soy lecithin-agar gels were prepared and examined on a 3 Tesla clinical scanner at 18.5° ± 0.5°C. Echoplanar sequences (b values: 0-1000/3000 s/mm2 ) were applied for ADC measurements. Quantitative relaxometry and MRS were performed for assessment of T1 , T2 , and detectable spectral components. RESULTS: The presence of soy lecithin significantly restricts the diffusion of water molecules and mimics the nearly Gaussian nature of diffusion observed in tissue (for b values <1000 s/mm2 ). ADC values ranged from 2.02 × 10-3 mm2 /s to 0.48 × 10-3 mm2 /s and cover the entire physiological range reported on biological tissue. Measured T1 /T2 values of pure lecithin solutions varied from 2685/2013 to 668/133 ms with increasing concentration. No characteristic signals of soy lecithin were observed in the MR spectrum. The addition of agar to the soy lecithin solutions allowed T2 values to be well adjusted to typical values found in parenchymal tissue without affecting the soy lecithin-controlled ADC value. CONCLUSION: Soy lecithin is a promising substance for the construction of diffusion phantoms with tissue-like ADC values. It provides several advantages over previously proposed substances, in particular a wide range of adjustable ADC values, the lack of additional 1 H-signals, and the possibility to adjust ADC and T2 values (by adding agar) almost independently of each other.
Asunto(s)
Lecitinas , Imagen por Resonancia Magnética , Agar , Imagen de Difusión por Resonancia Magnética , Fantasmas de ImagenRESUMEN
In this work, we propose a processing pipeline for the extraction and identification of meaningful radiomics biomarkers in skeletal muscle tissue as displayed using Dixon-weighted MRI. Diverse and robust radiomics features can be identified that may be of aid in the accurate quantification e.g. varying degrees of sarcopenia in respective muscles of large cohorts. As such, the approach comprises the texture feature extraction from raw data based on well established approaches, such as a nnU-Net neural network and the Pyradiomics toolbox, a subsequent selection according to adequate conditions for the muscle tissue of the general population, and an importance-based ranking to further narrow the amount of meaningful features with respect to auxiliary targets. The performance was investigated with respect to the included auxiliary targets, namely age, body mass index (BMI), and fat fraction (FF). Four skeletal muscles with different fiber architecture were included: the mm. glutaei, m. psoas, as well as the extensors and adductors of the thigh. The selection allowed for a reduction from 1015 available texture features to 65 for age, 53 for BMI, and 36 for FF from the available fat/water contrast images considering all muscles jointly. Further, the dependence of the importance rankings calculated for the auxiliary targets on validation sets (in a cross-validation scheme) was investigated by boxplots. In addition, significant differences between subgroups of respective auxiliary targets as well as between both sexes were shown to be present within the ten lowest ranked features by means of Kruskal-Wallis H-tests and Mann-Whitney U-tests. The prediction performance for the selected features and the ranking scheme were verified on validation sets by a random forest based multi-class classification, with strong area under the curve (AUC) values of the receiver operator characteristic (ROC) of 73.03 ± 0.70 % and 73.63 ± 0.70 % for the water and fat images in age, 80.68 ± 0.30 % and 88.03 ± 0.89 % in BMI, as well as 98.36 ± 0.03 % and 98.52 ± 0.09 % in FF.
Asunto(s)
Imagen por Resonancia Magnética , Sarcopenia , Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano de 80 o más Años , Imagen por Resonancia Magnética/métodos , Músculo Esquelético/diagnóstico por imagen , Sarcopenia/diagnóstico por imagen , Biomarcadores , Estudios RetrospectivosRESUMEN
PURPOSE: Biologically interesting signals can exhibit fast transverse relaxation and frequency shifts compared to free water. For spectral assignment, a ultra-short echo time (UTE) imaging sequence was modified to provide pixel-wise free-induction decay (FID) acquisition. METHODS: The UTE-FID approach presented relies on a multi-echo 3D spiral UTE sequence with six echoes per radiofrequency (RF) excitation (TEmin 0.05 ms, echo spacing 3 ms). A complex pixel-wise raw data set for FID spectroscopy is obtained by several multi-echo UTE measurements with systematic shifting of the readout by 0.25 or 0.5 ms, until the time domain is filled for 18 or 45 ms. B0 drifts are compensated by mapping and according phase correction. Autoregressive extrapolation of the signal is performed before Gaussian filtering. This method was applied to a phantom containing collagen-water solutions of different concentrations. To calculate the collagen content, a 19-peak collagen model was extracted from a non-selective FID spectrum (50% collagen solution). Proton-density-collagen-fraction (PDCF) was calculated for 10 collagen solutions (2%-50%). Furthermore, an in vivo UTE-FID spectrum of adipose tissue was recorded. RESULTS: UTE-FID signal patterns agreed well with the non-spatially selective pulse-acquire FID spectrum from a sphere filled with 50% collagen. Differentiation of collagen solution from distilled water in the PDCF map was possible from 4% collagen concentration for a UTE-FID sequence with 128 × 128 × 64 matrix (voxel size 1 × 1 × 2.85 mm3 ). The mean values of the PDCF correlate linearly with collagen concentration. CONCLUSION: The presented UTE-FID approach allows pixel-wise raw data acquisition similar to non-spatially selective pulse-acquire spectroscopy. Spatially resolved applications for assessment of spectra of rapidly decaying signals seem feasible.
Asunto(s)
Imagenología Tridimensional , Imagen por Resonancia Magnética , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen , Protones , Análisis EspectralRESUMEN
BACKGROUND: Quantification of pancreatic fat (PF) and intrahepatic lipids (IHL) is of increasing interest in subjects at risk for metabolic diseases. There is limited data available on short- and medium-term variability of PF/IHL and on their dependence on nutritional status. PURPOSE: To assess short-term intraday variations of PF/IHL after a high-fat meal as well as medium-term changes after 5 days of high-caloric diet. STUDY TYPE: Prospective cohort study. SUBJECTS: A total of 12 subjects (six males) for intraday variations study, 15 male subjects for medium-term high-caloric diet study and 11 age- and body mass index (BMI)-matched controls. FIELD STRENGTH/SEQUENCE: A 3 T; chemical-shift encoded multiecho gradient echo sequence. ASSESSMENT: For the intraday study, subjects were scanned after overnight fasting and after a high fat meal on the same day. For the medium-term study, 26 subjects were scanned after overnight fasting with 15/11 rescanned after 5 days of high-calorie diet/isocaloric diet. Proton density fat fraction (PDFF) maps were generated inline on the scanner. Regions of interest were manually drawn in head, body, and tail of pancreas and in the liver by a medical physicist and a doctoral student (26/4 years of experience). PF was calculated as the average of the head, body, and tail measurements. STATISTICAL TESTS: Repeated measurements ANOVA for assessing changes in PF/IHL, linear correlation analyses for assessing relationships of PF/IHL with BMI. Significance level P < 0.05 for all. RESULTS: Nonsignificant changes in PF (2.6 ± 1.0 vs. 2.7 ± 0.9% after high-fat meal, 1.4 ± 0.8 vs. 1.5 ± 0.6% [high-caloric diet] and 1.5 ± 0.8 vs. 1.8 ± 1.0% [isocaloric control group]), nonsignificant changes in IHL after high-fat meal (2.6 ± 1.3 vs. 2.5 ± 0.9%) and in the control group (1.1 ± 0.6 vs. 1.2 ± 1.1%), significantly increased IHL after high-caloric diet (1.7 ± 2.2% vs. 2.7 ± 3.6%). Nonsignificant changes in PF (2.6 ± 1.0 vs. 2.7 ± 0.9% after high-fat meal, 1.4 ± 0.8 vs. 1.5 ± 0.6% [high-caloric diet] and 1.5 ± 0.8 vs. 1.8 ± 1.0% [isocaloric control group]), nonsignificant changes in IHL after high-fat meal (2.6 ± 1.3 vs. 2.5 ± 0.9%) and in the control group (1.1 ± 0.6 vs. 1.2 ± 1.1%), significantly increased IHL after 5-days of high-caloric diet (1.7 ± 2.2% vs. 2.7 ± 3.6%). DATA CONCLUSION: Time of day and nutritional status have no significant influence on PF/IHL and are therefore not likely to be major confounders in epidemiologic or clinical studies. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 1.
Asunto(s)
Hígado , Protones , Tejido Adiposo/diagnóstico por imagen , Femenino , Humanos , Hígado/diagnóstico por imagen , Hígado/metabolismo , Imagen por Resonancia Magnética , Masculino , Páncreas/diagnóstico por imagen , Embarazo , Estudios ProspectivosRESUMEN
OBJECTIVE: To provide a basis for the selection of suitable emulsifiers in oil-in-water emulsions used as tissue analogs for MRI experiments. Three different emulsifiers were investigated with regard to their ability to stabilize tissue-like oil-in-water emulsions. Furthermore, MR signal properties of the emulsifiers themselves and influences on relaxation times and ADC values of the aqueous phase were investigated. MATERIALS AND METHODS: Polysorbate 60, sodium dodecyl sulfate (SDS) and soy lecithin were used as emulsifiers. MR characteristics of emulsifiers were assessed in aqueous solutions and their function as a stabilizer was examined in oil-in-water emulsions of varying fat content (10, 20, 30, 40, 50%). Stability and homogeneity of the oil-in-water emulsions were evaluated with a delay of 3 h and 9 h after preparation using T1 mapping and visual control. Signal properties of the emulsifiers were investigated by 1H-MRS in aqueous emulsifier solutions. Relaxometry and diffusion weighted MRI (DWI) were performed to investigate the effect of various emulsifier concentrations on relaxation times (T1 and T2) and ADC values of aqueous solutions. RESULTS: Emulsions stabilized by polysorbate 60 or soy lecithin were stable and homogeneous across all tested fat fractions. In contrast, emulsions with SDS showed a significantly lower stability and homogeneity. Recorded T1 maps revealed marked creaming of oil droplets in almost all of the emulsions with SDS. The spectral analysis showed several additional signals for polysorbate and SDS. However, lecithin remained invisible in 1H-MRS. Relaxometry and DWI revealed different influences of the emulsifiers on water: Polysorbate and SDS showed only minor effects on relaxation times and ADC values of aqueous solutions, whereas lecithin showed a strong decrease in both relaxation times (r1,lecithin = 0.11 wt.%-1 s-1, r2,lecithin = 0.57 wt.%-1 s-1) and ADC value (Δ(ADC)lecithin = - 0.18 × 10-3 mm2/sâ wt.%) with increasing concentration. CONCLUSION: Lecithin is suggested as the preferred emulsifier of oil-in-water emulsions in MRI as it shows a high stabilizing ability and remains invisible in MRI experiments. In addition, lecithin is suitable as an alternative means of adjusting relaxation times and ADC values of water.
Asunto(s)
Lecitinas , Polisorbatos , Emulsionantes , Emulsiones , Imagen por Resonancia Magnética , Tamaño de la Partícula , AguaRESUMEN
PURPOSE: The intravoxel distribution of the magnetic field strongly influences signal dephasing after RF excitation and the resulting signal decay in gradient echo-based MRI. In this work, several different field distribution models were applied and tested for analysis of microscopic field characteristics within pixels. THEORY: A flexible model for improved pixel-wise characterization of the underlying field distribution is introduced. The proposed symmetric alpha-stable (SαS) distribution covers Lorentzian, Gaussian, and intermediate field distributions in a continuous way using a two-parametric (width and shape) function. METHODS: The new model was applied on human brain, potatoes (homogeneous isotropic tissue), and stems of pineapple (anisotropic fibrous tissue). Effects of microscopic structure and background gradients on the shape and the widths of the microscopic field distribution were analyzed using gradient echo sampling of the spin echo and multigradient-echo sequences. Effects of non-Lorentzian shapes of microscopic field distributions on the results of common T2∗ measurements with mono-exponential fitting of signal values were tested. RESULTS: Many pixels of the examined objects showed field characteristics in between Lorentzian and Gaussian shapes. Microscopic field inhomogeneities caused by microscopic susceptibility effects and background gradients sometimes led to rather Gaussian than Lorentzian field distribution. In cases with nearly Gaussian field distribution, mono-exponential fitting of the signal decay resulted in different T2∗ values, depending on the sampling points. CONCLUSIONS: Using the concept of more flexible distributions for characterization of microscopic susceptibility effects in tissue provides better fitting of data and nearly sampling point-independent results than common T2∗ measurements with mono-exponential fitting.
Asunto(s)
Encéfalo , Imagen por Resonancia Magnética , Anisotropía , Encéfalo/diagnóstico por imagen , Humanos , Campos Magnéticos , Distribución NormalRESUMEN
1 H-MR spectroscopy of skeletal muscle provides insight into metabolism that is not available noninvasively by other methods. The recommendations given in this article are intended to guide those who have basic experience in general MRS to the special application of 1 H-MRS in skeletal muscle. The highly organized structure of skeletal muscle leads to effects that change spectral features far beyond simple peak heights, depending on the type and orientation of the muscle. Specific recommendations are given for the acquisition of three particular metabolites (intramyocellular lipids, carnosine and acetylcarnitine) and for preconditioning of experiments and instructions to study volunteers.
Asunto(s)
Consenso , Músculo Esquelético/diagnóstico por imagen , Espectroscopía de Protones por Resonancia Magnética , Testimonio de Experto , Humanos , Redes y Vías Metabólicas , Metaboloma , Músculo Esquelético/anatomía & histología , Músculo Esquelético/metabolismoRESUMEN
The standard procedure for blood glucose measurements is enzymatic testing. This method is cheap, but requires small samples of open blood with direct contact to the test medium. In principle, NMR provides non-contact analysis of body fluids, but high-field spectrometers are expensive and cannot be easily utilized under clinical conditions. Low-field NMR systems with permanent magnets are becoming increasingly smaller and more affordable. The studies presented here aim at exploring the capabilities of low-field NMR for measuring glucose concentrations in whole blood. For this purpose, a modern 1 T benchtop NMR spectrometer was used. Challenges arise from broad spectral lines, the glucose peak locations close to the water signal, low SNR and the interference with signals from other blood components. Whole blood as a sample comprises even more boundary conditions: crucial for reliable results are avoiding the separation of plasma and cells by gravitation and reliable reference values. First, the accuracy of glucose levels measured by NMR was tested using aqueous glucose solutions and commercially available bovine plasma. Then, 117 blood samples from oral glucose tolerance testing were measured with minimal preparation by simple pulse-acquire NMR experiments. The analysis itself is the key to achieve high precision, so several approaches were investigated: peak integration, orthogonal projection to latent structure analysis and support vector machine regression. Correlations between results from the NMR spectra and the routine laboratory automated analyzer revealed an RMSE of 7.90 mg/dL for the best model. 91.5% of the model output lies within the limits of the German Medical Association guidelines, which require the glucose measurement to be within 11% of the reference method. It is concluded that spectral quantification of glucose in whole blood samples by high-quality NMR spectrometers operating at 1 T is feasible with sufficient accuracy.
Asunto(s)
Glucemia/análisis , Espectroscopía de Resonancia Magnética , Animales , Bovinos , Estudios de Factibilidad , Prueba de Tolerancia a la Glucosa , Humanos , Análisis de los Mínimos Cuadrados , Sistemas de Atención de Punto , Valores de Referencia , Procesamiento de Señales Asistido por Computador , Soluciones , Máquina de Vectores de SoporteRESUMEN
BACKGROUND: Quantitative assessment of pulmonary blood flow and visualization of its temporal and spatial distribution without contrast media is of clinical significance. PURPOSE: To assess the potential of electrocardiogram (ECG)-triggered pseudocontinuous arterial spin labeling (PCASL) imaging with balanced steady-state free-precession (bSSFP) readout to measure lung perfusion under free-breathing (FB) conditions and to study temporal and spatial characteristics of pulmonary blood flow. STUDY TYPE: Prospective, observational. SUBJECTS: Fourteen volunteers; three patients with pulmonary embolism. FIELD STRENGTH/SEQUENCES: 1.5T, PCASL-bSSFP. ASSESSMENT: The pulmonary trunk was labeled during systole. The following examinations were performed: 1) FB and timed breath-hold (TBH) examinations with a postlabeling delay (PLD) of 1000 msec, and 2) TBH examinations with multiple PLDs (100-1500 msec). Scan-rescan measurements were performed in four volunteers and one patient. Images were registered and the perfusion was evaluated in large vessels, small vessels, and parenchyma. Mean structural similarity indices (MSSIM) was computed and time-to-peak (TTP) of parenchymal perfusion in multiple PLDs was evaluated. Image quality reading was performed with three independent blinded readers. STATISTICAL TESTS: Wilcoxon test to compare MSSIM, perfusion, and Likert scores. Spearman's correlation to correlate TTP and cardiac cycle duration. The repeatability coefficient (RC) and within-subject coefficient of variation (wCV) for scan-rescan measurements. Intraclass correlation coefficient (ICC) for interreader agreement. RESULTS: Image registration resulted in a significant (P < 0.05) increase of MSSIM. FB perfusion values were 6% higher than TBH (3.28 ± 1.09 vs. 3.10 ± 0.99 mL/min/mL). TTP was highly correlated with individuals' cardiac cycle duration (Spearman = 0.89, P < 0.001). RC and wCV were better for TBH than FB (0.13-0.19 vs. 0.47-1.54 mL/min/mL; 6-7 vs. 19-60%). Image quality was rated very good, with ICCs 0.71-0.89. DATA CONCLUSION: ECG-triggered PCASL-bSSFP imaging of the lung at 1.5T can provide very good image quality and quantitative perfusion maps even under FB. The course of labeled blood through the lung shows a strong dependence on the individuals' cardiac cycle duration. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY STAGE: 2 J. MAGN. RESON. IMAGING 2020;52:1767-1782.
Asunto(s)
Imagen por Resonancia Magnética , Circulación Pulmonar , Arterias , Humanos , Estudios Prospectivos , Reproducibilidad de los Resultados , Marcadores de SpinRESUMEN
PURPOSE: Motion is 1 extrinsic source for imaging artifacts in MRI that can strongly deteriorate image quality and, thus, impair diagnostic accuracy. In addition to involuntary physiological motion such as respiration and cardiac motion, intended and accidental patient movements can occur. Any impairment by motion artifacts can reduce the reliability and precision of the diagnosis and a motion-free reacquisition can become time- and cost-intensive. Numerous motion correction strategies have been proposed to reduce or prevent motion artifacts. These methods have in common that they need to be applied during the actual measurement procedure with a-priori knowledge about the expected motion type and appearance. For retrospective motion correction and without the existence of any a-priori knowledge, this problem is still challenging. METHODS: We propose the use of deep learning frameworks to perform retrospective motion correction in a reference-free setting by learning from pairs of motion-free and motion-affected images. For this image-to-image translation problem, we propose and compare a variational auto encoder and generative adversarial network. Feasibility and influences of motion type and optimal architecture are investigated by blinded subjective image quality assessment and by quantitative image similarity metrics. RESULTS: We observed that generative adversarial network-based motion correction is feasible producing near-realistic motion-free images as confirmed by blinded subjective image quality assessment. Generative adversarial network-based motion correction accordingly resulted in images with high evaluation metrics (normalized root mean squared error <0.08, structural similarity index >0.8, normalized mutual information >0.9). CONCLUSION: Deep learning-based retrospective restoration of motion artifacts is feasible resulting in near-realistic motion-free images. However, the image translation task can alter or hide anatomical features and, therefore, the clinical applicability of this technique has to be evaluated in future studies.
Asunto(s)
Aprendizaje Profundo , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Adulto , Femenino , Cabeza/diagnóstico por imagen , Movimientos de la Cabeza/fisiología , Humanos , Masculino , Adulto JovenRESUMEN
The liver is a central regulator of whole body glucose, and lipid homeostasis and hepatokines, like fetuin-A, have been identified as markers and mediators of fatty liver-induced cardiometabolic risk. The closely related protein fetuin-B was shown to be upregulated in the fatty liver and to impact on glucose homeostasis in mice. In the present study we aimed to test the relevance of these findings in humans. In 55 subjects, hepatic mRNA expression of both hepatokines, fetuin-A and fetuin-B, associated positively with liver triglyceride content, whereas only fetuin-A expression associated with the homeostatic model assessment of insulin resistance. In 220 subjects who underwent precise metabolic phenotyping, circulating fetuin-A, but not fetuin-B, associated positively with liver fat content, and negatively with insulin sensitivity, measured during the oral glucose tolerance test (OGTT) and during the euglycemic, hyperinsulinemic clamp. Both circulating fetuin-A and fetuin-B correlated positively with the glucose area under the curve during the OGTT, but after additional adjustment for insulin sensitivity this relationship remained significant only for fetuin-B. In conclusion, despite the fact that the two hepatokines, fetuin-A and fetuin-B, are upregulated in the state of hepatic steatosis in humans, it appears that they differently impact on glucose homeostasis. Our data are in agreement with observations that fetuin-A can alter insulin signaling and that fetuin-B may regulate glucose homeostasis via so far unknown effects, possibly on glucose effectiveness.
Asunto(s)
Hígado Graso/sangre , Hígado Graso/genética , Fetuína-B , alfa-2-Glicoproteína-HS , Anciano , Estudios de Cohortes , Hígado Graso/metabolismo , Hígado Graso/patología , Femenino , Fetuína-B/análisis , Fetuína-B/genética , Fetuína-B/metabolismo , Prueba de Tolerancia a la Glucosa , Humanos , Resistencia a la Insulina/fisiología , Hígado/metabolismo , Hígado/patología , Masculino , Persona de Mediana Edad , Enfermedad del Hígado Graso no Alcohólico/sangre , Enfermedad del Hígado Graso no Alcohólico/genética , Enfermedad del Hígado Graso no Alcohólico/patología , ARN Mensajero/análisis , ARN Mensajero/metabolismo , Regulación hacia Arriba/genética , alfa-2-Glicoproteína-HS/análisis , alfa-2-Glicoproteína-HS/genética , alfa-2-Glicoproteína-HS/metabolismoRESUMEN
PURPOSE: Assessment of temporal and spatial relations between spontaneous mechanical activities in musculature (SMAM) at rest as revealed by diffusion-weighted imaging (DWI) and electrical muscular activities in surface EMG (sEMG). Potential influences of static and radiofrequency magnetic fields on muscular activity on sEMG measurements at rest were examined systematically. METHODS: Series of diffusion-weighted stimulated echo planar imaging were recorded with concurrent sEMG measurements. Electrical activities in sEMG were analyzed by non-parametric Friedman and two-sample Kolmogorov-Smirnov test. Direct correlation of both modalities was investigated by temporal mapping of electrical activity in sEMG to DWI repetition interval. RESULTS: Electrical activities in sEMG and number of visible SMAMs in DWI showed a strong correlation (ρ = 0.9718). High accordance between sEMG activities and visible SMAMs in DWI in a near-surface region around sEMG electrodes was achieved. Characteristics of sEMG activities were almost similar under varying magnetic field conditions. CONCLUSION: Visible SMAMs in DWI have shown a close and direct relation to concurrent signals recorded by sEMG. MR-related magnetic fields had no significant effects on findings in sEMG. Hence, appearance of SMAMs in DWI should not be considered as imaging artifact or as effects originating from the special conditions of MR examinations. Spatial and temporal distributions of SMAMs indicate characteristics of spontaneous (microscopic) mechanical muscular action at rest. Therefore, DWI techniques should be considered as non-invasive tools for studying physiology and pathophysiology of spontaneous activities in resting muscle. Magn Reson Med 79:2784-2794, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Asunto(s)
Electromiografía/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Músculo Esquelético/diagnóstico por imagen , Procesamiento de Señales Asistido por Computador , Adulto , Femenino , Humanos , Pierna/diagnóstico por imagen , Pierna/fisiología , Masculino , Persona de Mediana Edad , Músculo Esquelético/fisiología , Adulto JovenRESUMEN
The purpose of this work was assessment of volumetric characteristics of spontaneous mechanical activities in musculature (SMAMs) by diffusion-weighted simultaneous multi-slice (DW-SMS) imaging and spatial correlation to anatomical structure, as revealed by fusion to fiber tractographic information derived from diffusion-tensor imaging (DTI). The feasibility of using DW-SMS to image spontaneous events in human musculature was assessed by phantom measurements. Series of DW-SMS images and DTI datasets were recorded from the resting calf of three human subjects. Simultaneously recorded SMAMs in multiple slices were analyzed regarding spatial extension by the Kolmogorov-Smirnov test. Direct correlation of spatial distribution of SMAMs and fiber orientation was investigated by mapping of muscle fibers to multi-slice SMAM datasets. The DW-SMS strategy allows simultaneous assessment of SMAMs in several slices of resting skeletal musculature, since 73.9% of SMAM-affected volumes have shown SMAMs in multiple DW-SMS slices. Spatial extension of SMAMs was highly correlated over different simultaneously recorded DW-SMS slices, and affected areas followed the orientation of muscle fibers with a connectivity ratio up to 57.18 ± 14.80% based on event count and connectivity count maps. In 89.2% of all SMAM-affected datasets muscle fiber connectivity was shown in at least two adjacent slices. Direct correlation between SMAMs in human lower leg musculature and underlying anatomical structure was revealed by high muscle fiber connectivity (89.2%). SMAMs have shown a wide distribution along the longitudinal muscle direction (73.9% in multiple DW-SMS slices) with direct involvement of muscle fibers. Correlation between SMAMs in multiple DW-SMS slices and crossing muscular fiber tracts provides evidence that SMAMs result from physiological processes in musculature. Fusion of DW-SMS with DTI facilitates non-invasive studies of muscle fiber involvement in SMAMs in resting muscle.
Asunto(s)
Imagen por Resonancia Magnética , Fibras Musculares Esqueléticas/fisiología , Adulto , Imagen de Difusión Tensora , Humanos , Persona de Mediana Edad , Fantasmas de ImagenRESUMEN
We performed the largest randomized, placebo-controlled clinical trial to date (N = 112, 12-week intervention) to investigate the effects and safety of resveratrol supplementation on liver fat content and cardiometabolic risk parameters in overweight and obese and insulin-resistant subjects. At baseline the variability in liver fat content was very large, ranging from 0.09% to 37.55% (median, 7.12%; interquartile range, 3.85%-12.94%). Mean (SD) liver fat content was 9.22 (6.85) % in the placebo group and 9.91 (7.76) % in the resveratrol group. During the study liver fat content decreased in the placebo group (-0.7%) but not in the resveratrol group (-0.03%) (differences between groups: P = .018 for the intention-to-treat [ITT] population; N = 54, resveratrol, N = 54, placebo and P = .0077 for the per protocol [PP] population). No effects of resveratrol supplementation on cardiometabolic risk parameters were observed. Resveratrol supplementation was well tolerated and safe. In conclusion, these data suggest that resveratrol supplementation is safe and that it does not considerably impact liver fat content or cardiometabolic risk parameters in humans.
Asunto(s)
Antioxidantes/uso terapéutico , Suplementos Dietéticos , Resistencia a la Insulina , Grasa Intraabdominal/diagnóstico por imagen , Hígado/diagnóstico por imagen , Enfermedad del Hígado Graso no Alcohólico/diagnóstico por imagen , Sobrepeso/metabolismo , Resveratrol/uso terapéutico , Adulto , Anciano , Método Doble Ciego , Femenino , Hemoglobina Glucada/metabolismo , Humanos , Hígado/metabolismo , Masculino , Persona de Mediana Edad , Enfermedad del Hígado Graso no Alcohólico/metabolismo , Espectroscopía de Protones por Resonancia MagnéticaRESUMEN
OBJECTIVES: Our objectives were to provide an automated method for spatially resolved detection and quantification of motion artifacts in MR images of the head and abdomen as well as a quality control of the trained architecture. MATERIALS AND METHODS: T1-weighted MR images of the head and the upper abdomen were acquired in 16 healthy volunteers under rest and under motion. Images were divided into overlapping patches of different sizes achieving spatial separation. Using these patches as input data, a convolutional neural network (CNN) was trained to derive probability maps for the presence of motion artifacts. A deep visualization offers a human-interpretable quality control of the trained CNN. Results were visually assessed on probability maps and as classification accuracy on a per-patch, per-slice and per-volunteer basis. RESULTS: On visual assessment, a clear difference of probability maps was observed between data sets with and without motion. The overall accuracy of motion detection on a per-patch/per-volunteer basis reached 97%/100% in the head and 75%/100% in the abdomen, respectively. CONCLUSION: Automated detection of motion artifacts in MRI is feasible with good accuracy in the head and abdomen. The proposed method provides quantification and localization of artifacts as well as a visualization of the learned content. It may be extended to other anatomic areas and used for quality assurance of MR images.
Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética , Abdomen/diagnóstico por imagen , Algoritmos , Artefactos , Automatización , Procesamiento Automatizado de Datos , Cabeza/diagnóstico por imagen , Humanos , Imagenología Tridimensional , Aprendizaje Automático , Movimiento (Física) , Redes Neurales de la Computación , Probabilidad , Garantía de la Calidad de Atención de Salud , Reproducibilidad de los Resultados , Procesamiento de Señales Asistido por ComputadorRESUMEN
PURPOSE: To enable fast and flexible high-resolution four-dimensional (4D) MRI of periodic thoracic/abdominal motion for motion visualization or motion-corrected imaging. METHODS: We proposed a Cartesian three-dimensional k-space sampling scheme that acquires a random combination of k-space lines in the ky/kz plane. A partial Fourier-like constraint compacts the sampling space to one half of k-space. The central k-space line is periodically acquired to allow an extraction of a self-navigated respiration signal used to populate a k-space of multiple breathing positions. The randomness of the acquisition (induced by periodic breathing pattern) yields a subsampled k-space that is reconstructed using compressed sensing. Local image evaluations (coefficient of variation and slope steepness through organs) reveal information about motion resolvability. Image quality is inspected by a blinded reading. Sequence and reconstruction method are made publicly available. RESULTS: The method is able to capture and reconstruct 4D images with high image quality and motion resolution within a short scan time of less than 2 min. These findings are supported by restricted-isometry-property analysis, local image evaluation, and blinded reading. CONCLUSION: The proposed method provides a clinical feasible setup to capture periodic respiratory motion with a fast acquisition protocol and can be extended by further surrogate signals to capture additional periodic motions. Retrospective parametrization allows for flexible tuning toward the targeted applications. Magn Reson Med 78:632-644, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
Asunto(s)
Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Movimiento/fisiología , Torso/diagnóstico por imagen , Algoritmos , Humanos , Respiración , Estudios RetrospectivosRESUMEN
It is generally accepted that the amount and distribution of adipose tissue (AT) in the human body play an important role in the pathogenesis of metabolic diseases. In addition, metabolic effects of released saturated fatty acids (FAs) in blood are known to be more critical than those of unsaturated FAs. However, little is known about the variability in unsaturation of FAs in various AT compartments. The aim of this prospective study was the assessment of mono- and polyunsaturated FAs in various AT compartments by localized 1 H-MRS in order to obtain insight into the intra- and interindividual variability. Associations of FA unsaturation with intrahepatic lipids (IHLs), insulin sensitivity and related AT volumes were analyzed. Fifty healthy Caucasians (36 male, 14 female) participated in this study. Spectroscopic examinations were performed in subcutaneous adipose tissue in the neck (SCATneck ), abdominal deep subcutaneous adipose tissue (DSCAT), abdominal superficial subcutaneous adipose tissue (SSCAT), visceral adipose tissue (VAT), tibial bone marrow (BM) and subcutaneous adipose tissue of the lower leg (SCATcalf ) at 3 T. Unsaturated index (UI) was calculated by the ratio of olefinic and methyl resonances, polyunsaturated index (PUI) by the ratio of diallylic and methyl resonances. Volumes of AT compartments (by T1 -weighted MRI) and IHL (single-voxel STEAM) were assessed at 1.5 T, insulin sensitivity by an oral glucose tolerance test. UI was highest for SCATcalf (0.622) and lowest for BM (0.527). Highest PUI was observed for SSCAT (0.108), lowest for BM (0.093). Significant intraindividual differences between UIs-but not PUIs-are present for most compartments. There is a non-significant trend for higher UI in males but otherwise no correlation to anthropometric data (age, BMI). A significant negative correlation between UI and AT volume was observed for VAT but for none of the other compartments. Neither UIs nor PUIs show a relation with IHL; insulin sensitivity is significantly correlated to UI in BM (p < 0.01). Unsaturation indices in several distinct AT compartments are location dependent. Our cohort showed only moderate gender-related differences, with a trend towards less unsaturated FAs (mainly PUI) in females. In BM, insulin resistant subjects are characterized by a higher UI compared with the insulin sensitive ones. Further studies in larger cohorts are necessary to gain further insight into unsaturation of AT.