1.
BMC Musculoskelet Disord ; 24(1): 790, 2023 Oct 05.
Artículo en Inglés | MEDLINE | ID: mdl-37798626

RESUMEN

BACKGROUND: Glenoid bone loss is among the most important risk factors for recurrent anterior shoulder instability, and a bony reconstruction is recommended in cases of critical bone loss (> 15%). The commonly used surgical techniques, including coracoid transfer, are associated with considerable complications. The aim of this study was to assess the motion at the glenoid-bone-block interface after coracoid and spina-scapula bone-block reconstruction of the anterior glenoid. METHODS: Twelve cadaveric shoulders were tested. A 20% bone defect of the anterior glenoid was created, and the specimens were randomly assigned for glenoid augmentation using a coracoid bone block (n = 6) or a scapular spine bone block (n = 6). The glenoid-bone interface was cyclically loaded for 5000 cycles with a force of 170 N. The micromotion was tracked using an optical measurement system (GOM ARMIS) and was evaluated with the GOM Correlate Pro software. RESULTS: The most dominant motion component was medial irreversible displacement for the spina-scapula (1.87 mm; SD: 1.11 mm) and coracoid bone blocks (0.91 mm; SD: 0.29 mm) (n.s.). The most medial irreversible displacement took place during the first nine cycles. The inferior reversible displacement was significantly greater for spina-scapula bone blocks (0.28 mm, SD: 0.16 mm) compared to coracoid bone blocks (0.06 mm, SD: 0.10 mm) (p = 0.02). CONCLUSIONS: The medial irreversible displacement is the dominant motion component in a bone-block reconstruction after a critical bone loss of the anterior glenoid. The spina-scapula and coracoid bone blocks are comparable in terms of primary stability and extent of motion. Thus, spina-scapula bone blocks may serve as alternatives in bony glenoid reconstruction from a biomechanical point of view.


Asunto(s)
Inestabilidad de la Articulación , Articulación del Hombro , Humanos , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía , Inestabilidad de la Articulación/etiología , Inestabilidad de la Articulación/cirugía , Trasplante Óseo/métodos , Escápula/diagnóstico por imagen , Escápula/cirugía , Cadáver
2.
BMC Musculoskelet Disord ; 24(1): 395, 2023 May 18.
Artículo en Inglés | MEDLINE | ID: mdl-37198565

RESUMEN

INTRODUCTION: In lumbar spinal stabilization pedicle screws are used as standard. However, especially in osteoporosis, screw anchorage is a problem. Cortical bone trajectory (CBT) is an alternative technique designed to increase stability without the use of cement. In this regard, comparative studies showed biomechanical superiority of the MC (midline cortical bone trajectory) technique with longer cortical progression over the CBT technique. The aim of this biomechanical study was to comparatively investigate the MC technique against the not cemented pedicle screws (TT) in terms of their pullout forces and anchorage properties during sagittal cyclic loading according to the ASTM F1717 test. METHODS: Five cadavers (L1 to L5), whose mean age was 83.3 ± 9.9 years and mean T Score of -3.92 ± 0.38, were dissected and the vertebral bodies embedded in polyurethane casting resin. Then, one screw was randomly inserted into each vertebra using a template according to the MC technique and a second one was inserted by freehand technique with traditional trajectory (TT). The screws were quasi-static extracted from vertebrae L1 and L3, while for L2, L4 and L5 they were first tested dynamically according to ASTM standard F1717 (10,000 cycles at 1 Hz between 10 and 110 N) and then quasi-static extracted. In order to determine possible screw loosening, there movements were recorded during the dynamic tests using an optical measurement system. RESULTS: The pull-out tests show a higher pull-out strength for the MC technique of 555.4 ± 237.0 N compared to the TT technique 448.8 ± 303.2 N. During the dynamic tests (L2, L4, L5), 8 out of the 15 TT screws became loose before completing 10,000 cycles. In contrast, all 15 MC screws did not exceed the termination criterion and were thus able to complete the full test procedure. For the runners, the optical measurement showed greater relative movement of the TT variant compared to the MC variant. The pull-out tests also revealed that the MC variant had a higher pull-out strength, measuring at766.7 ± 385.4 N, while the TT variant measured 637.4 ± 435.6 N. CONCLUSION: The highest pullout forces were achieved by the MC technique. The main difference between the techniques was observed in the dynamic measurements, where the MC technique exhibited superior primary stability compared to the conventional technique in terms of primary stability. Overall, the MC technique in combination with template-guided insertion represents the best alternative for anchoring screws in osteoporotic bone without cement.


Asunto(s)
Osteoporosis , Tornillos Pediculares , Fusión Vertebral , Humanos , Anciano , Anciano de 80 o más Años , Vértebras Lumbares/cirugía , Huesos , Osteoporosis/cirugía , Hueso Cortical/cirugía , Cementos para Huesos , Fenómenos Biomecánicos , Fusión Vertebral/métodos
3.
Biomed Eng Online ; 21(1): 80, 2022 Nov 23.
Artículo en Inglés | MEDLINE | ID: mdl-36419171

RESUMEN

BACKGROUND: Accurate evaluation of the mechanical properties of trabecular bone is important, in which the internal bone marrow plays an important role. The aim of this systematic review is to investigate the roles of bone marrow on the mechanical properties of trabecular bone to better support clinical work and laboratory research. METHODS: A systematic review of the literature published up to June 2022 regarding the role of bone marrow on the mechanical properties of trabecular bone was performed, using PubMed and Web of Science databases. The journal language was limited to English. A total of 431 articles were selected from PubMed (n = 186), Web of Science (n = 244) databases, and other sources (n = 1). RESULTS: After checking, 38 articles were finally included in this study. Among them, 27 articles discussed the subject regarding the hydraulic stiffening of trabecular bone due to the presence of bone marrow. Nine of them investigated the effects of bone marrow on compression tests with different settings, i.e., in vitro experiments under unconfined and confined conditions, and computer model simulations. Relatively few controlled studies reported the influence of bone marrow on the shear properties of trabecular bone. CONCLUSION: Bone marrow plays a non-neglectable role in the mechanical properties of trabecular bone, its contribution varies depending on the different loading types and test settings. To obtain the mechanical properties of trabecular bone comprehensively and accurately, the solid matrix (trabeculae) and fluid-like component (bone marrow) should be considered in parallel rather than tested separately.


Asunto(s)
Médula Ósea , Hueso Esponjoso , Simulación por Computador , Bases de Datos Factuales , Lenguaje
4.
Biomed Eng Online ; 21(1): 3, 2022 Jan 11.
Artículo en Inglés | MEDLINE | ID: mdl-35012556

RESUMEN

BACKGROUND: Demographic change is leading to an increase in the number of osteoporotic patients, so a rethink is required in implantology in order to be able to guarantee adequate anchoring stability in the bone. The functional modification of conventional standard screw implants using superelastic, structured Ti6Al4V anchoring elements promises great potential for increasing anchoring stability. METHODS: For this purpose, conventional screw implants were mechanically machined and extended so that structured-superelastic-positionable-Ti6Al4V anchoring elements could be used. The novel implants were investigated with three tests. The setup of the anchoring elements was investigated in CT studies in an artificial bone. In a subsequent simplified handling test, the handling of the functional samples was evaluated under surgical conditions. The anchorage stability compared to standard screw implants was investigated in a final pullout test according to ASTM F543-the international for the standard specification and test methods for metallic medical bone screws. RESULTS: The functionalization of conventional screw implants with structured superelastic Ti6Al4V anchoring elements is technically realizable. It was demonstrated that the anchoring elements can be set up in the artificial bone without any problems. The anchorage mechanism is easy to handle under operating conditions. The first simplified handling test showed that at the current point of the investigations, the anchoring elements have no negative influence on the surgical procedure (especially under the focus of screw implantation). Compared to conventional standard screws, more mechanical work is required to remove the functional patterns completely from the bone. CONCLUSION: In summary, it was shown that conventional standard screw implants can be functionalized with Ti6Al4V-structured NiTi anchoring elements and the new type of screws are suitable for orthopedic and neurosurgical use. A first biomechanical test showed that the anchoring stability could be increased by the anchoring elements.


Asunto(s)
Tornillos Óseos , Huesos , Aleaciones , Fenómenos Biomecánicos , Humanos , Ensayo de Materiales
5.
Cell Tissue Bank ; 23(3): 499-510, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34714441

RESUMEN

Our study aimed to asses the defatting efficiency of different methods, which are commonly used and easily available in the laboratory in order to find a method that is effective, convenient, safe, and economical. Cylindrical cancellous bone specimens were obtained from fresh-frozen human cadaver femoral condyles, cut into multiple small specimens (Ø8 × 2 mm), and assigned to two groups that were treated with either chemical solvent soaking (Solvent group) or ultrasonic cleaning (Ultrasound group). Each group was divided into several subgroups based on different treatments. Digital photographs were taken of each specimen. The difference of material density (Δρb), apparent density (Δρapp), and porosity (ΔP) before and after treatment were used as evaluation indicators. For the solvent group, in Δρb, only the combination of 99% ethanol and detergent solution showed a significant difference before and after treatment (P = 0.00). There was no significant difference in ΔP among acetone, the mixture of 99% ethanol and acetone, and the combination of 99% ethanol and detergent solution (P = 0.93). For the ultrasound group, the median of all subgroups in Δρapp and ΔP were all lower than the solvent group. The combination of 99% ethanol and detergent solution (v/v = 1:20), as well as the mixture of 99% ethanol and acetone (v/v = 1:1), seem to be the optimal defatting methods for 2 mm thick cancellous bone slices due to their effectiveness, availability, low-cost and safety. Chemical soaking for 24 h is more effective than ultrasonic cleaning with 99% ethanol or acetone for 20 or 40 min.


Asunto(s)
Hueso Esponjoso , Ultrasonido , Acetona , Densidad Ósea , Detergentes/farmacología , Etanol/farmacología , Humanos , Solventes
6.
Arch Orthop Trauma Surg ; 142(4): 641-648, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33884453

RESUMEN

PURPOSE: Horizontal instability is a common problem after acromioclavicular joint injuries. The aim of this study was to evaluate if there is a difference regarding horizontal stability between an anatomical and a non-anatomical configuration of the double tunnel coraco-clavicular ligament reconstruction of the acromioclavicular joint. METHODS: Thirteen acromioclavicular joints of human cadaveric shoulders in ethanol-glycerin fixation were included in the study and underwent cyclic anterior and posterior translational testing at a load of 70 N using an electromechanical uniaxial testing machine. The shoulders were randomly assigned to the following groups: double coraco-clavicular tunnel technique in an anatomical configuration (DCTa) and double coraco-clavicular tunnel technique in an inverse configuration of the anatomical position (DCTb). The dislocation was recorded with a 3D optical measuring system. RESULTS: The total horizontal displacement (p10 = 0.0221; p5000 = 0.082) was significantly higher for the non-anatomical reconstruction (DCTb) compared to the anatomical reconstruction (DCTa) after every measured amount of cycles. The increase in displacement for DCTb group was overall higher than the increase in displacement for DCTa group but without significance. CONCLUSION: Reconstruction of the CC ligaments in an anatomical configuration with two suture devices results in a significantly higher stability of the AC joint in the horizontal plane than reconstruction of the CC ligaments in a non-anatomical configuration. Based on the results of this biomechanical in vitro study, the use of a double coraco-clavicular reconstruction should focus on an anatomically correct position of the suture devices.


Asunto(s)
Articulación Acromioclavicular , Artroplastia de Reemplazo , Luxaciones Articulares , Articulación Acromioclavicular/lesiones , Articulación Acromioclavicular/cirugía , Fenómenos Biomecánicos , Cadáver , Clavícula/lesiones , Humanos , Luxaciones Articulares/cirugía , Ligamentos Articulares/cirugía
7.
Arch Orthop Trauma Surg ; 142(11): 3093-3099, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33970320

RESUMEN

INTRODUCTION: Atraumatic necrosis of the femoral head (AFHN) is a common disease with an incidence of 5000-7000 middle-aged adults in Germany. There is no uniform consensus in the literature regarding the configuration of the bone in AFHN. The clinical picture of our patients varies from very hard bone, especially in idiopathic findings, and rather soft bone in cortisone-induced necrosis. A better understanding of the underlying process could be decisive for establishing a morphology-dependent approach. The aim of this study is the closer examination of the condition of the bone in the AFHN compared to the primary hip osteo arthritis (PHOA). MATERIALS AND METHODS: The preparations were obtained as part of elective endoprosthetic treatment of the hip joint. Immediately after sample collection, thin-slice CT of the preserved femoral heads was performed to determine the exact density of the bone in the necrosis zone. Reconstruction was done in 0.8-1 mm layers in two directions, coronary and axial, starting from the femoral neck axis. Density of the femoral heads was determined by grey value analysis. The value in Hounsfield units per sample head was averaged from three individual measurements to minimize fluctuations. For biomechanical and histomorphological evaluation, the samples were extracted in the load bearing zone perpendicular to the surface of the femoral head. Group-dependent statistical evaluation was performed using single factor variance analysis (ANOVA). RESULTS: A total of 41 patients with a mean age of 64.44 years were included. The mean bone density of the AFHN samples, at 1.432 g/cm3, was about 7% higher than in the PHOA group with a mean value of 1.350 g/cm3 (p = 0.040). The biomechanical testing in the AFHN group showed a 22% higher-but not significant-mean compressive strength (20.397 MPa) than in the PHOA group (16.733 MPa). On the basis of histological analysis, no differentiation between AFHN and PHOA samples was possible. CONCLUSIONS: The present study (NCT, evidence level II) shows that AFHN has a very well detectable higher bone density compared to PHOA. However, neither biomechanical stress tests nor histomorphological evaluation did show any significant difference between the groups. The results allow the conclusion that there is no "soft" necrosis at all in the AFHN group.


Asunto(s)
Cortisona , Necrosis de la Cabeza Femoral , Osteoartritis de la Cadera , Adulto , Fenómenos Biomecánicos , Cabeza Femoral/diagnóstico por imagen , Cabeza Femoral/cirugía , Necrosis de la Cabeza Femoral/cirugía , Articulación de la Cadera/cirugía , Humanos , Persona de Mediana Edad , Osteoartritis de la Cadera/diagnóstico por imagen , Osteoartritis de la Cadera/cirugía
8.
Orthopade ; 50(8): 608-613, 2021 Aug.
Artículo en Alemán | MEDLINE | ID: mdl-34228159

RESUMEN

Deformity due to neuromuscular disease is often progressive and associated with reduced vital capacity. In general, all treatment should be performed in specialized centers, since invasive measures are associated with an increased morbidity compared to adolescent scoliosis. Derived from the etiology and the resulting biomechanical basis (characteristics), important aspects and considerations arise for all healthcare institutions from the examination interval to the duration of conservative therapy and initiation of surgical therapy. Proper monitoring and assessment are key components to identify curve progression and to achieve preservation or improvement of basic functions.


Asunto(s)
Enfermedades Neuromusculares , Escoliosis , Adolescente , Humanos , Enfermedades Neuromusculares/epidemiología , Pronóstico , Escoliosis/diagnóstico , Escoliosis/epidemiología
9.
BMC Musculoskelet Disord ; 21(1): 597, 2020 Sep 07.
Artículo en Inglés | MEDLINE | ID: mdl-32894106

RESUMEN

BACKGROUND: The presence of muscular deficiency seems to be a major cause of back pain that requires counteractions. Considering that the autochthonous back muscles, responsible for straightening and stabilizing the spine, cannot be activated voluntarily, they can be strengthened only through specific training. The computer-supported test and training system (CTT) Centaur (BfMC GmbH, Leipzig, SN, Germany) seems well suited for this purpose. To show its potential as a reliable diagnostic and training tool, this study aimed to evaluate the test-retest reliability of this 3D spatial rotation device. METHODS: A prospective pilot study was conducted in 20 healthy volunteers of both sexes. For test-retest reliability analysis, three measurements were performed with a two-day interval between each measurement. Each measurement consisted of a one-minute endurance test performed in eight different positions (transverse plane). During the test, the subject was tilted by 90° in the sagittal plane from a neutral, upright position. Meanwhile, the subject's level of upper body stabilization along the body axis was assessed. All trunk movements (momentum values) were quantified by a multicomponent force sensor and standardized relative to the subject's upper body mass. The range of motion was assessed by 95% confidence ellipse analysis. Here, all position-specific confidence ellipses for each measurement were merged to a summarized quantity. Finally, ICC analysis using a single-rating, absolute agreement, two-way mixed-effects model and a Bland-Altman plot was performed to determine the reliability. RESULTS: Considering all measurements (t1, t2, t3), the ICC for reliability evaluation was 0.805, and the corresponding 95% confidence interval (CI) was [0.643, 0.910]. Moreover, the Bland-Altman plots for all three pairs of time points did not show significant differences. CONCLUSION: This study concludes that the CTT Centaur shows good test-retest reliability, indicating it can be used in clinical practice in the future.


Asunto(s)
Computadores , Músculos , Femenino , Alemania , Humanos , Masculino , Proyectos Piloto , Estudios Prospectivos , Reproducibilidad de los Resultados
10.
Arch Orthop Trauma Surg ; 140(4): 511-516, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31980876

RESUMEN

PURPOSE: Numerous techniques have been described for the tibial-sided graft preparation in anterior cruciate ligament (ACL) reconstruction. The use of less suture material for graft preparation is thought to improve ingrowth and to reduce the risk for infection. At the same time, the suture construct should be strong enough to resist the surgeon's pull during tensioning of the transplant. METHODS: In total, 39 fresh-frozen procine deep flexor tendons were used and prepared as four-strand grafts. In the three-suture group (n = 19), graft preparation was performed using three tibial-sided sutures, with each tendon end sutured separately. In the one-suture group (n = 20), a modified graft preparation using only one tibial-sided suture was applied. Each sample underwent load-to-failure testing (Nmax) after cyclic pre-loading. To estimate intraoperative tension forces acting on the tibial-sided suture constructs, the maximal tension force of 26 volunteers on such a construct was measured using a load cell. RESULTS: The biomechanical testing of the two different suture constructs showed a significantly higher load-to-failure for the three-suture group (711 N ± 91 N) compared to the one-suture group (347 N ± 24 N) (p = 0.0001). In both groups, the mode of failure was a tear of the suture in all samples. A failure of the suture-tendon interface was not observed in any case. The median maximal tension force on the construct applied by the 26 volunteers was 134 N (range 73-182 N). CONCLUSION: The presented single-suture tendon graft preparation resisted to smaller failure loads than the conventional three-suture technique. However, no failures in the suture-tendon interface were seen and the failure loads observed were far beyond the tension forces that can be expected intraoperatively. Hence, the single-suture graft preparation technique may be a valuable alternative to the conventional technique.


Asunto(s)
Reconstrucción del Ligamento Cruzado Anterior/métodos , Ligamento Cruzado Anterior/cirugía , Técnicas de Sutura , Tendones/trasplante , Tibia/cirugía , Animales , Porcinos
11.
J Anat ; 234(3): 346-358, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30536830

RESUMEN

The sacroiliac joint (SIJ) is a well-known source of low back and pelvic pain, of increasing interest for both conservative and surgical treatment. Alterations in the kinematics of the pelvis have been hypothesized as a major cause of SIJ-related pain. However, definitions of both the range and the extent of physiological movement are controversial, and there are no clear baseline data for pathological alterations. The present study combined a novel biomechanical setup allowing for physiological motion of the lumbosacral transition and pelvis without restricting the SIJ movement in vitro, combined with optical image correlation. Six fresh human pelvises (81 ± 10 years, three females, three males) were tested, with bodyweight-adapted loading applied to the fifth lumbar vertebra and both acetabula. Deformation at the lumbopelvises was determined computationally from three-dimensional image correlation data. Sacroiliac joint motion under the loading of 100% bodyweight primarily consisted of a z-axis rotation (0.16°) and an inferior translation of the sacrum relative to the ilium (0.32 mm). Sacroiliac joint flexion-extension rotations were minute (< 0.02°). Corresponding movements of the SIJ were found at the lumbosacral transition, with an anterior translation of L5 relative to the sacrum of -0.97 mm and an inferior translation of 0.11 mm, respectively. Moreover, a flexion of 1.82° was observed at the lumbosacral transition. Within the innominate bone and at the pubic symphysis, small complementary rotations were seen around a vertical axis, accounting for -0.10° and 0.11°, respectively. Other motions were minute and accompanied by large interindividual variation. The present study provides evidence of different SIJ motions than reported previously when exerted by physiological loading. Sacroiliac joint kinematics were in the sub-degree and sub-millimeter range, in line with previous in vivo and in vitro findings, largely limited to the sagittal rotation and an inferior translation of the sacrum relative to the ilium. This given physiological loading scenario underlines the relevance of the lumbosacral transition when considering the overall motion of the lumbopelvis, and how relatively little the other segments contribute to overall motion.


Asunto(s)
Rango del Movimiento Articular , Articulación Sacroiliaca , Anciano , Anciano de 80 o más Años , Fenómenos Biomecánicos , Femenino , Humanos , Ilion/anatomía & histología , Imagenología Tridimensional , Dolor de la Región Lumbar , Masculino , Movimiento/fisiología , Pelvis/anatomía & histología , Rango del Movimiento Articular/fisiología , Articulación Sacroiliaca/anatomía & histología , Articulación Sacroiliaca/fisiología , Sacro/anatomía & histología
12.
Knee Surg Sports Traumatol Arthrosc ; 27(12): 3827-3834, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31420689

RESUMEN

PURPOSE: Horizontal instability-especially in the posterior plane-is a common problem after acromioclavicular joint injuries. The purpose was to compare the stability of a single coraco-clavicular tunnel technique and a double coraco-clavicular tunnel technique for coraco-clavicular ligament reconstruction and to examine the influence of an additional acromioclavicular cerclage on the horizontal stability in the acromioclavicular joint. METHODS: 21 acromioclavicular joints of human cadaveric shoulders were randomly assigned to the following groups: single coraco-clavicular tunnel technique with horizontal augmented acromioclavicular cerclage (SCT + AC); double coraco-clavicular tunnel technique (DCT); double coraco-clavicular tunnel technique and acromioclavicular cerclage (DCT + AC). The specimens underwent cyclic horizontal testing and were recorded using a 3D optical measuring system. RESULTS: The displacement and the increase in displacement in relation to the displacement after precondition for SCT + AC were significantly higher after every measured amount of cycles than for DCT (p10 = 0.0023; p5000 = 0.0012) and DCT + AC (p10 = 0.0006; p5000 = 0.0012). There was no significant difference in the total displacement, or in the increase in total displacement between double coraco-clavicular tunnel reconstructed groups with and without additional acromioclavicular cerclage. CONCLUSION: Double coraco-clavicular tunnel technique with and without additional acromioclavicular cerclage results in a significant higher stability regarding the horizontal plane in comparison to single coraco-clavicular tunnel technique with acromioclavicular cerclage. Based on the results of this biomechanical in vitro study, the use of an additional acromioclavicular cerclage with single coraco-clavicular tunnel technique may not be indicated in most cases. The effect of an additional acromioclavicular cerclage seems to be negligible, at least in presence of a double-coraco-clavicular tunnel technique reconstruction. Techniques of AC joint reconstruction should focus on the use of double coraco-clavicular tunnel devices.


Asunto(s)
Articulación Acromioclavicular/cirugía , Artroscopía/métodos , Inestabilidad de la Articulación/cirugía , Anciano de 80 o más Años , Cadáver , Humanos
13.
BMC Musculoskelet Disord ; 19(1): 314, 2018 Aug 31.
Artículo en Inglés | MEDLINE | ID: mdl-30170580

RESUMEN

BACKGROUND: Dislocation following total hip arthroplasty has to date not been resolved satisfactorily. Previous work has shown that using a less-invasive adaption of Bauer's lateral transgluteal approach with capsular repair significantly reduces dislocation rates in primary total hip arthroplasty. The aim of this retrospective cohort study was to assess whether this approach also helps to reduce the dislocation rate in revision total hip arthroplasty. METHODS: We analyzed revision total hip arthroplasty cases performed between 10/2005 and 12/2013 in our department, classifying capsular repair cases as study group and capsular resection cases as control group. The WOMAC score, the dislocations and the revisions were observed. RESULTS: A total of 259 cases were included, 100 in the study group and 159 in the control group. In the 12-month follow-up, dislocation rates were significantly lower in the study group (3%, n = 3) compared to the control group (21.4%, n = 34; p = 0.001). Overall follow-up periods were 49 and 79 months, revision frequencies were 10 and 29%, pain improvements were 5.5 compared to 4.4 and the WOMAC global scores averaged 2.0 ± 2.1 and 2.9 ± 2.6 for the study group and the control group, respectively. CONCLUSION: The modified, less-invasive, lateral transgluteal approach with capsular repair was accompanied by an 86% reduction in dislocation rates when compared to the conventional technique with capsular resection via the anterolateral Watson-Jones-approach. Capsular repair is possible in about 60% of the revision total hip arthroplasty cases, may be considered as beneficial to avoid dislocation and can therefore be recommended.


Asunto(s)
Artroplastia de Reemplazo de Cadera/tendencias , Luxación de la Cadera/diagnóstico por imagen , Liberación de la Cápsula Articular/tendencias , Reoperación/tendencias , Artroplastia de Reemplazo de Cadera/efectos adversos , Estudios de Cohortes , Femenino , Estudios de Seguimiento , Luxación de la Cadera/etiología , Humanos , Liberación de la Cápsula Articular/efectos adversos , Masculino , Reoperación/efectos adversos , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento
15.
BMC Musculoskelet Disord ; 17: 149, 2016 Apr 06.
Artículo en Inglés | MEDLINE | ID: mdl-27048598

RESUMEN

BACKGROUND: To ensure adequate function after orthopedic tumor reconstruction, it is important to reattach the remaining soft tissue to the implant. This study aimed at obtaining mechanical properties of textile muscle-implant and muscle-bone connections in a preliminary test. METHODS: Two groups of soft-tissue attachment were mechanically tested and compared: Native bone-muscle samples obtained from human femora and muscles attached to a prosthetic implant by means of Trevira® attachment tubes. Additionally, muscle samples were tested with muscle fibers aligned parallel and perpendicular to the tension load. A uniaxial load was exerted upon all samples. RESULTS: Failure loads of 26.7 ± 8.8 N were observed for the native bone-muscle group and of 18.1 ± 9.9 N for the Trevira® group. Elongations of 94.8 ± 36.2 % were observed for the native bone-muscle group and 79.3 ± 51.8 % for the Trevira® group. The location of failure was mainly observed in the central area of the muscle fibers. Muscle fibers with parallel fiber orientation (47.6 ± 11.5 N) yielded higher tensile strength than those with perpendicular fiber orientation (14.8 ± 4.1 N). CONCLUSIONS: Our experiments showed that higher forces were transmitted in the origin and insertion areas than in areas of flat soft tissue reconstruction using attachment tubes. The data indicate that the tested material allows reattaching muscles, but without reinforcing the insertion site. Therefore, attachment tubes with region-dependent and potentially anisotropic material behavior might be advantageous to optimize muscle-bone load transmission after surgery, which may allow lower complication rates and shorter physical recovery.


Asunto(s)
Fémur/cirugía , Procedimientos Ortopédicos/instrumentación , Implantación de Prótesis/instrumentación , Músculo Cuádriceps/cirugía , Anciano , Anciano de 80 o más Años , Fenómenos Biomecánicos , Cadáver , Fémur/fisiopatología , Humanos , Masculino , Procedimientos Ortopédicos/efectos adversos , Diseño de Prótesis , Implantación de Prótesis/efectos adversos , Músculo Cuádriceps/fisiopatología , Resistencia a la Tracción , Soporte de Peso
16.
Arch Orthop Trauma Surg ; 135(6): 795-803, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25896822

RESUMEN

BACKGROUND: Decreasing numbers of students are interested in starting a surgical career, posing substantial challenges to patient care in the next years. The anatomy course is one of the key subjects in medical training, especially in surgical disciplines. Innovative teaching concepts that integrate surgically relevant anatomy and manual dexterity might help boost student interest in surgery. METHODS: A preclinical workshop entitled "Surgical exposures" was developed. A team of anatomists and surgeons introduced the surgical exposures, demonstrating the procedures on Thiel-fixed body donors. Following this introduction, students practiced the exposures in an operating room-like manner. A six-point Likert scale was used to evaluate the workshop and to compare it to the first-year dissection course. RESULTS: The overall evaluation result for the surgical exposures was excellent, proving to be a significantly better result when compared to the first-year dissection course. The students were more satisfied with the teaching time invested by the peers and regarded the workshop as clinically highly relevant. Furthermore, they felt that questions were addressed better and that the overall atmosphere was better than in the gross anatomy course. Subject to criticism was the course size and practicing time in both cases. DISCUSSION: The surgical exposures workshop provides preclinical students with clinically relevant anatomy and manual dexterity. It may positively influence the decision to follow a surgical career. This course, however, requires extensive teaching resources. The given concept may help implement practical medical skills in the preclinical curriculum, strengthening the professional identity of surgeons and anatomists.


Asunto(s)
Anatomía Regional/educación , Curriculum , Educación de Pregrado en Medicina/métodos , Cirugía General/educación , Estudiantes de Medicina , Enseñanza/métodos , Anciano de 80 o más Años , Cadáver , Evaluación Educacional , Femenino , Humanos , Masculino
17.
GMS Hyg Infect Control ; 19: Doc06, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38505094

RESUMEN

Errors in laboratory diagnostics of viral infections primarily occur during the preanalytical phase, which is especially observed in sample collection. Hitherto, no efforts have been made to optimize oropharyngeal smears. An accurate method to analyze the necessary conditions for a valid oropharyngeal smear test is required, especially to avoid false negative results, which can lead to promotion of the spread of viruses such as SARS-CoV-2. In this study, a maximum-force failure analysis was performed on a swab, and the highest tolerable force was then measured on 20 healthy volunteers to obtain the dimensions of the possible force to be applied on a swab. Subsequently, a device which can validate and reproducibly indicate this force during swab collection was developed. The study demonstrated that swabs generally fail at a maximum force of 5 N. Furthermore, an average force of 2.4±1.0 N was observed for the 20 volunteers. Lastly, this study described the development of a device which presents the selected force with a mean accuracy of 0.05 N (Force applied by Device 1: 0.46±0.05 N, Device 2: 1.55±0.11 N, Device 3: 2.57±0.18 N) and provides feedback via haptic and acoustic clicks as well as with a visual indicator. In the future, the swab will be analyzed for the presence of viral pathogens to determine its diagnostic performance corresponding to the force (German Clinical Trials Register Number 00024455).

18.
Clin Biomech (Bristol, Avon) ; 114: 106235, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38552372

RESUMEN

BACKGROUND: Stability is regarded as an important factor for proper healing and avoiding secondary dislocation in osteoporotic fractures of the proximal humerus. Several surgical techniques have been proposed for treatment, including intramedullary nail osteosynthesis and locking plate fixation. This study introduces a novel approach that combines both techniques and compares its primary stability with conventional methods. METHODS: The study involved 25 osteoporotic humeri with two-part fracture models, which were randomly assigned to locking-plate fixation, intramedullary nailing, or a combination of both techniques. The specimens were subjected to sinusoidal loading at 250 N in 20° abduction for 5000 cycles and then to quasi-static loading until failure. Fracture movement, failure mode, and failure load were measured and compared among the groups. FINDINGS: The groups fixated with intramedullary nailing and the groups fixated with intramedullary nailing and locking plate fixation showed significantly lower fracture motion than the group using locking plate fixation only (p < 0.005) and significantly higher load to failure (p = 0.007 and p = 0.0062, respectively). There was no significant difference between the group using intramedullary nailing and the group using locking-plate fixation and intramedullary nailing in fracture movement or load-to-failure (p > 0.005). INTERPRETATION: The results indicate that locking plate fixation provides less primary stability than intramedullary nailing or the combined of both techniques. This combined approach may offer advantages as a treatment for complex proximal humeral fractures in osteoporotic bone, and specific implants should be developed to ensure optimal treatment.


Asunto(s)
Fijación Intramedular de Fracturas , Fracturas del Húmero , Fracturas Osteoporóticas , Fracturas del Hombro , Humanos , Fijación Interna de Fracturas/métodos , Fijación Intramedular de Fracturas/métodos , Fracturas Osteoporóticas/cirugía , Húmero/cirugía , Fracturas del Hombro/cirugía , Placas Óseas , Fenómenos Biomecánicos , Clavos Ortopédicos , Fracturas del Húmero/cirugía
19.
J Spine Surg ; 10(2): 232-243, 2024 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-38974498

RESUMEN

Background: Gold standard for determining bone density as a surrogate parameter of bone quality is measurement of bone mineral density (BMD) by dual energy X-ray absorptiometry (DXA), most commonly performed on the lumbar spine (L1-L4). Computed tomography (CT) data are often available for surgical planning prior to spine procedures, but currently this information is not standardized for bone quality assessment. Besides, measuring the Hounsfield-Units (HU) is also of great importance in the context of biomechanical studies. This in vitro study aims in comparing BMD from DXA and HU based on diagnostic CT scans. In addition, methods are presented to quantify local density variations within bones. Methods: One hundred and seventy-six vertebrae (L1-L4) from 44 body donors (age 84.0±8.7 years) were studied. DXA measurements were obtained on the complete vertebrae to determine BMD, as well as axial CT scans with a slice thickness of 1 mm. Using Mimics Innovation Suite image processing software (Materialise NV, Leuven, Belgium), two volumes (whole vertebra vs. spongious bone) were formed for each vertebra, which in turn were divided in their left and right sides. From these total of six volumes, the respective mean HU was determined. HU of the whole vertebra and just spongious HU were compared with the BMD of the corresponding vertebrae. Side specific differences were calculated as relative values. Results: Whole bone and spongious HU correlated significantly (P>0.001; α=0.01) with BMD. A positive linear correlation was found, which was more pronounced for whole bone HU (R=0.72) than for spongious HU (R=0.62). When comparing the left and right sides within each vertebra, the HU was found to be 10% larger on average on one side compared to the opposite side. In some cases, the difference of left and right spongious bone can be up to 170%. There is a tendency for the side comparison to be larger for the spongious HU than for the whole vertebra. Conclusions: Determination of HU from clinical CT scans is an important tool for assessing bone quality, primarily by including the cortical portion in the calculation of HU. Unlike BMD, HU can be used to distinguish precisely between individual regions. Some of the very large side-specific gradients of the HU indicate an enormous application potential for preoperative patient-specific planning.

20.
Orthopadie (Heidelb) ; 53(7): 519-526, 2024 Jul.
Artículo en Alemán | MEDLINE | ID: mdl-38829401

RESUMEN

Aseptic implant loosening is the primary cause of revisions in arthroplasty. Various in vitro and in vivo methods are available for assessing implant fixation and stability. The aim of the Musculoskeletal Biomechanics Research Network (MSB-NET) is to continuously improve or develop these methods. In vitro analyses are often conducted using static and dynamic ISO and ASTM standards, while RSA, DXA, and EBRA analyses are established in vivo methods for evaluating implant fixation. Primary stability analyses, as well as acoustical methods, provide additional opportunities to detect loosening early and precisely evaluate implant stability. The cluster serves as a link between basic research, clinical practice, and end users to promote in vitro and in vivo methods to improve implant safety.


Asunto(s)
Falla de Prótesis , Humanos , Prótesis Anclada al Hueso , Análisis de Falla de Equipo/métodos